INSTALLATION
INSTRUCTIONS
Built-In 27" & 30"
Electric Wall Ovens
403 WEST FOURTH STREET, NORTH · NEWTON IA 50208
27" SINGLE WALL OVEN
1 1/4" Dia Conduit Access Hole*
1
2 5/8" Plywood Floor (Must Support 142 lbs)
DIMENSIONS
in cm
A
27MIN 68.58
B
24 MIN 60.96
C
27 7/16
D
E
F
G
H
I
1
2
A
B
C
D
E
F
G
H
I
±1/16 69.69
23 1/2 MIN 59.69
±1/16 64.77
25 1/2
27 3/4 70.49
26 3/4 67.95
24 7/16 62.07
4 to 33 10.2 to 83.8
27" DOUBLE WALL OVEN
1 1/4" Dia Conduit Access Hole*
5/8" Plywood Floor (Must Support 250 lbs)
DIMENSIONS
in cm
27 MIN 68.58
24 MIN 60.96
49 5/8
±1/16 126.05
23 1/2 MIN 59.69
25 1/2
±1/16 64.77
49 15/16 126.84
26 3/4 67.95
24 7/16 62.07
4 to 12 10.2 to 30.5
30" SINGLE WALL OVEN
1 1 1/4" Dia Conduit Access Hole*
2
5/8" Plywood Floor (Must Support 142 lbs)
DIMENSIONS
A
B
C
D
E
F
G
H
I
1
2
A
B
C
D
E
F
G
H
I
in cm
30 MIN 76.20
24 MIN 60.96
±1/16 69.69
27 7/16
23 1/2 MIN 59.69
±1/16 71.60
28 3/16
27 3/4 70.49
29 3/4 75.57
24 7/16 62.07
4 to 33 10.2 to 83.8
30" DOUBLE WALL OVEN
1 1/4" Dia Conduit Access Hole*
5/8" Plywood Floor (Must Support 250 lbs)
DIMENSIONS
in cm
30 MIN 76.20
24 MIN 60.96
49 5/8
±1/16 126.05
23 1/2 MIN 59.69
±1/16 71.60
28 3/16
49 15/16 126.84
29 3/4 75.57
24 7/16 62.07
4 to 12 10.2 to 30.5
SINGLE WALL OVEN
DOUBLE WALL OVEN
30" WALL OVEN UNDER COUNTER27" WALL OVEN UNDER COUNTER
1
1 1/4" Dia Conduit Access Hole*
2
5/8" Plywood Floor (Must Support 142 lbs)
DIMENSIONS
in cm
A
B
C
D
E
F
G
H
I
J
25 63.50
24 MIN 60.96
27 7/16 ±1/16 69.69
23 1/2 MIN 59.69
25 1/2 ±1/16 64.77
27 3/4 70.49
26 3/4 67.95
24 7/16 62.07
36 91.44
1 1/2 3.81
27" WALL OVEN 30" WALL OVEN
* * COOKTOPS
K 4 Burner Gas 2 1/8 MIN 5.4 MIN 2 1/8 MIN 5.4 MIN
K Electric 3 1/8 MIN 7.9 MIN 3 1/8 MIN 7.9 MIN
K Induction 3 1/8 MIN 7.9 MIN 3 1/8 MIN 7.9 MIN
in cm in cm
1
1 1/4" Dia Conduit Access Hole*
2
5/8" Plywood Floor (Must Support 142 lbs)
DIMENSIONS
in cm
A
B
C
D
E
F
G
H
I
J
25 63.50
24 MIN 60.96
27 7/16 ±1/16 69.69
23 1/2 MIN 59.69
28 3/16 71.60
27 3/4 70.49
29 3/4 75.57
24 7/16 62.07
36 91.44
1 1/2 3.81
NOTE: * Hole must be cut as close to corner of cabinet as possible.
** See Dealer for approved cooktops.
NOTES
Z Do not block air intake slots along bottom of oven
Y Gas or electric cooktops may be installed over ovens. See
cooktop installation instructions for cutout size.
W Electrical connection for electric cooktop must be in adjacent ac
cessible location. Cooktop and wall oven must be on separate
120/240 or 120\208 volt 60 Hz AC circuits.
8101P306-60
(04-99-01)
-
When installing a 27" walloven under a 30" cooktop some
interference may occur. The following cutout notching of
the side trims will eliminate the interference of the side trim
to the burner box. After cutting, file the side trim edges to
eliminate burrs.
Installing Bottom Trim Piece
Electrical Connections
Unit to be properly circuit protected and wired according to
local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
CAUTION
For European style cabinets (flush front) the required
clearance for operation of the oven door is minimum
spacing of 7/8" between the cutout and the door,
hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough,
due to their construction, to allow this installation.
1. Cut hole in cabinet to mount oven. Cutout in cabinet
should be level and straight.
Note: There are no provisions to level the unit after it
is installed. An oven that is not level could
cause poor baking results.
2. Install plywood floor as shown.
3. Attach unit to the cabinet with four No. 8x1" screws
supplied with unit inside of envelope containing these
instructions. Pre-drill holes in cabinet for attachment
screws using 1/8" drill. Oven mounting holes are
provided in side trim.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
front of unit for power requirements.
The neutral of this unit is grounded to the frame through the
green or solid grounding wire. (The green and the white
wires are twisted together at the termination of the conduit.)
If local conditions do not permit grounding of the neutral,
untwist the green wire and connect the green wire to
ground in accordance with local codes. Connect the white
neutral to the service neutral.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit on
the circuit.
RECOMMENDED MINIMUM
K.W. RATING CIRCUIT PROTECTION WIRE SIZE
ON SERIAL PLATE IN AMPERS (AWG)
15,0 -14.8 20 12
14.9 -16.9 30 10
17.0 -19.9 40 18
10.0 - 11.9 50 18
12.0 - 14.9 60 16
Service
4. See instructions at right for electrical hook-up.
5. See Use and Care Manual for operating instructions.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE
Interrupt the source of electricity to the unit when attempting
to repair or service the oven. Failure to do this could result
in a dangerous or even fatal shock.