Maytag MLG52PDAWS, MLG52PDAWW Installation Instructions

Page 1
MLG52 Installation Manual
RETAIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 113284-1
Page 2
Dryer Safety
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
!
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
!
DANGER
You can be killed or seriously injured if you don’t immediately follow instructions.
!
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer smells gas. This information should be obtained from your gas supplier.
Post the following warning in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; Do not
use any phone in your building.
Clear the room, building or area of all
occupants.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
You can be killed or seriously injured if you don’t follow instructions.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
– Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur; Ne pas
vous servir des téléphones se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
– L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
2 Maytag Co. 113284-1
Page 3
WARNING: Gas leaks cannot always be detected by smell. Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer. WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
Read all instructions before using the dryer.
Do not place items exposed to cooking oils in your
dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable, or explosive substances as they give off vapors that could ignite or explode.
Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving.
Do not install or store the dryer where it will be
exposed to the weather.
Do not tamper with controls.
Do not repair or replace any part of the dryer or
attempt any servicing unless specifically recommended in this installation manual or in published user-repair instructions that you understand and have the skills to carry out.
Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
Clean lint screen every third load to fourth.
Keep area around the exhaust opening and
adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
See installation instructions for grounding requirements.
SAVE THESE INSTRUCTIONS
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
113284-1 Maytag Co. 3
Page 4
Important Information ________________
IMPORTANT: A means of restraint must be used to avoid straining of the gas supply when the dryer is moved.
An external means of power removal (disconnect device) must be provided by the installer.
“Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation.”
«Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de câblage peuvent entraîner un fonctionnement inadéquat et dangereux.»
The wiring diagram for the dryer is located behind the front control panel.
List of Acronyms _____________________________
HVAC Heating, Ventilating, and Air-Conditioning
in WC Inches of Water Column
L.C.D. Liquid Crystal Display
L.P. Liquid Propane
Table of Contents _______________
Specifications .......................................................... 5
Installation Procedures .......................................... 7
Location Requirements ......................................... 7
Dryer Enclosure Requirements ............................. 8
Fresh Air Supply Requirements............................. 8
Exhaust Requirements .......................................... 8
Electrical Information........................................... 10
Gas Information................................................... 12
Preparation for Operation / Start-Up.................... 14
Preoperational Test ............................................. 14
Operating Instructions ......................................... 14
Shutdown Instructions ......................................... 14
Service / Parts Information................................... 14
Service ................................................................ 14
Parts .................................................................... 14
Routine Maintenance ............................................ 15
Cleaning .............................................................. 15
Adjustments ........................................................ 15
UL Underwriters Laboratory
NOTES __________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
Data Label Information ......................................... 16
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
4 Maytag Co. 113284-1
Page 5
Specifications _____________________________________________________________________
MAXIMUM CAPACITY
(DRY WEIGHT) PER POCKET
50 lb TUMBLER DIAMETER 32-3/4 TUMBLER DEPTH 32-3/4 TUMBLER VOLUME
PER POCKET
TUMBLER / DRIVE MOTOR BLOWER / FAN MOTOR DOOR OPENING
(DIAMETER)
DOOR SILL HEIGHT
PER POCKET
TOP POCKET / BOTTOM POCKET
PER POCKET
16 cu ft
1/3 hp 1/4 hp
23-3/4
52-1/2 / 11-7/8
133.35 cm / 29.97 cm
22.68 kg
83.19 cm
83.19 cm
453.0 L
0.25 kW
0.186 kW
60.3 cm
DRYERS PER 20’/40’ CONTAINER 8 / 16 DRYERS PER 48’/53’ TRUCK 25 / 27
VOLTAGE AVAILABLE 120 1ø 2w 60 Hz APPROXIMATE NET WEIGHT 910 lb APPROXIMATE SHIPPING WEIGHT 960 lb AIRFLOW HEAT INPUT EXHAUST CONNECTION
GAS
PER POCKET
PER POCKET
540 cfm
110,000 Btu/hr
(DIAMETER) PER POCKET
(1) 10
(2) 8
412.77 kg
435.45 kg
15.20 cmm
27,720 kcal/hr
20.32 cm
25.4 cm
COMPRESSED AIR CONNECTION N / A COMPRESSED AIR VOLUME N / A INLET PIPE CONNECTION
Shaded areas are stated in metric equivalents 10/30/12
PER POCKET
1/2 M.N.P.T.
NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
113284-1 Maytag Co. 5
Page 6
Specifications _____________________________________________________________________
NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
6 Maytag Co. 113284-1
Page 7
Installation Procedures ______________
Location Requirements ______________
!
WARNING
Excessive Weight Hazard
Use two or more people and mechanical equipment to lift, move and install dryer.
Failure to do so can result in back or other injury.
Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1­LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).
Leveling Dryer
The dryer is equipped with 4 leveling legs, 1 at each corner of the base. For optimum performance the dryer should be level front-to-back and side-to-side.
Tools Required
Utility Knife to remove packaging
9/16 Box wrench or 9/16 socket to remove pallet bolts
#2 Phillips screwdriver to open front toe panel
Pipe wrench for gas connections
7/8 open end wrench or adjustable wrench
to install coin box lock
®
TORX
1/4 socket or 1/4 open end wrench to make the
A pair of slip-joint pliers
®
TORX is a registered trademark of Textron Innovations, Inc.
T20 TORX® T25 to open rear bottom guard
to get foot adjustment ends
leg adjustment
Installing Door Handle
1. Remove handle from dryer tumbler.
2. Unwrap door handle from bubble wrap.
3. Locate handle standoff in the handle slots.
4. Insert 1/4-20 x 2-1/4 stainless Truss Head Phillips screws through preexisting door holes.
5. Having handle flushed against door, tighten the two stainless Phillips screws.
!
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Do not install in a garage. Failure to do so can result in death, explosion, or
fire.
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).
The operation of this dryer may affect the operation of other types of gas dryers, which take their air for safe combustion from the same room. If in doubt, consult the dryer manufacturer(s).
The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements section).
Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements section).
Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual (refer to Exhaust Requirements section).
The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements section).
IMPORTANT: The dryer should be located where a minimum amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air openings into the combustion chamber.
IMPORTANT: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
113284-1 Maytag Co. 7
Page 8
Dryer Enclosure Requirements ______
Bulkheads and partitions should be made of non-combustible material.
NOTE: Allowances must be made for opening the control door.
A The requirement to allow the door to open completely is
35-inches (88.9 cm).
B A minimum overhead clearance of 6-inches (15.24 cm)
is required.
C Dryer should be positioned a minimum of 16-inches
(40.64 cm) away from the nearest obstruction. 30-inches (76.2 cm) is recommended for ease of installation,
maintenance, and service. D 1/16” (1.5875 mm) minimum is required. E Flooring should be level or below dryer cabinet for ease
of removing panels during maintenance. F Dryers may be positioned sidewall to sidewall, however
a 1/16” (1.5875 mm) minimum allowance must be made
for the opening and closing of the control door, along
with the removal of panels during maintenance.
A = 22-inches (55.88 cm) B = 20-inches (50.8 cm)
EXAMPLE: For a bank of four 60 Hz dryers, 2 unrestricted openings measuring 22-inches by 20-inches (55.88 cm by
50.8 cm) are acceptable. To compensate for the use of registers or louvers used over
the openings, this area must be increased by approximately 33%. Make-up air openings should not be located in an area directly near where exhaust vents exit the building.
Allowances must be made for remote or constricting passageways or where dryers are located at high altitudes or predominantly low pressure areas.
IMPORTANT: Make-up air must be free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components.
Fresh Air Supply Requirements ______
When the dryer is operating, it draws in room air, heats it, passes this air through the tumbler, and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. The dryer must be installed with provisions for adequate combustion and make-up air supply.
Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer. Fresh air ventilation openings shall not be blocked and/or sealed. As a general rule, an unrestricted air entrance from the outdoors of 220 inch (Based on 1 inch
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to all the dryers.
2
(1419.35 cm2) is required for each 60 Hz dryer.
2
[6.5 cm2] per 1,000 Btu [252 kcal].)
NOTE: Component failure due to dry cleaning solvent fumes will void the warranty.
Exhaust Requirements _______________
Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure, which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limits, or lint chamber hi-limit protector thermostat. The dryer must be installed with a proper exhaust duct connection to the outside.
As per the National Fuel Gas Code, “Exhaust ducts for type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge (0.0195­inches [0.50 mm]) thick.”
8 Maytag Co. 113284-1
Page 9
!
WARNING
Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in
death or fire.
The ductwork should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible. There should be a minimum 6-inch (15.24 cm) clearance between the dryer top and the first bend in the ductwork for ease of servicing. Single or independent dryer venting is recommended. It is suggested that the use of 90° turns be avoided; use 30° and/or 45° bends instead. The radius of the elbows should preferably be 1-1/2 times the diameter of the duct. All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. When adding ducts, overlap the duct being connected. All ductwork joints must be taped to prevent moisture and lint from escaping into the building. Back draft dampers must be installed in all commonly ducted systems. Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork.
Single Dryer Venting
IMPORTANT: For extended ductwork runs, the cross­sectional area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional HVAC firm should be consulted for proper venting information.
IMPORTANT: It is recommended that exhaust or booster fans not be used in the exhaust ductwork system.
Exhaust back pressure measured by a manometer/ magnehelic in the exhaust duct must be no less than 0 and must not exceed 0.6 in WC (1.48 mb).
NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening.
The ductwork for this appliance must be suitable for the appliance category in accordance with national installation regulations of the country of destination.
Outside Venting Protection
To shelter the outside end of the horizontal ductwork from the weather, a 90° elbow bent downward should be installed where the exhaust exits the building. If the ductwork travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction (refer to the diagram).
IMPORTANT: Do not use screens, louvers, or caps on the outside opening of the exhaust ductwork.
113284-1 Maytag Co. 9
Page 10
The illustration below shows the minimum cross-sectional area for multiple dryer round or square venting. These figures must be increased if the main duct run from the last dryer to where it exhausts to the outdoors is longer than 12 feet (3.66 meters) or has more than 1 elbow in it.
Multiple Dryer Venting with 10-Inch (25.4 cm) Diameter
1080 cfm (30.58 cmm) Exhaust Connections at Common Duct
NUMBER OF DRYERS 4 3 2 1
MINIMUM CROSS­SECTIONAL AREA
MINIMUM ROUND DUCT DIAMETER
A = 10-inches (25.4 cm) B = 12 feet (3.66 meters)
SQ IN 314 254 153 79
SQ CM 2025.8 1638.71 987.09 509.67
IN 20 18 14 10
CM 50.8 45.72 35.56 25.4
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
NOTE 2 Distance should be 2 times the diameter of the duct to the nearest
obstruction.
Multiple Dryer (Common) Venting
IMPORTANT: For extended ductwork runs, the cross­sectional area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional HVAC firm should be consulted for proper venting information.
If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be channeled into a common main duct. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45º in the direction of airflow. The main duct should be tapered, with the diameter increasing before each individual duct is added. The minimum diameter of the individual ductwork must be at least 10-inches (25.4 cm).
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
NOTE 2 Distance should be 2 times the diameter of the duct to the nearest
obstruction.
Electrical Information ________________
Electrical Requirements
All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and national regulations or codes of the country of destination. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will void the warranty.
Each pocket should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections.
IMPORTANT: No more than four dryers should be connected to one main common duct.
10 Maytag Co. 113284-1
Page 11
NOTE: The use of aluminum wire will void the warranty. An individual ground circuit must be provided to each
pocket, do not daisy chain. Component failure due to improper voltage application will
void the warranty. The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.
IMPORTANT: A separate protected circuit must be provided to each pocket.
It is necessary to have a power disconnect for each dryer. These disconnects must be located within 30 feet (9 meters) of the dryer.
The dryer must be connected to the electric supply shown on the data label.
Electrical Service Specifications
Gas Models Only
ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)
NOTES: A.
B.
SERVICE
VOLTAGE
120 1ø 2 14.6 15
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
60 Hz 50 Hz
CIRCUIT
BREAKER
10/26/12
Grounding
A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or codes of the country of destination. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.
Electrical Connections
A wiring diagram is located behind the control panel with connection data.
If local codes permit, power to the dryer can be made by the use of a flexible UL listed power cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
!
WARNING
Fire Hazard Use 12 gauge solid copper wire. Use a UL listed strain relief. Connect the white wire to the white wire from the
electric service; Connect the black wire to the black wire from the electric service; Connect the green wire to the green wire from the ground connection.
Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
Single-Phase (1ø) Wiring Connections / Hookup
The electrical input connections are made into the service box located on the top toward the back of the dryer. The ground connection is made to the copper lug, also provided in this box. To gain access, the service box cover must be removed.
Insert incoming white wire (neutral) for the top pocket into the far right hand connection.
Insert incoming black wire (L1) for the top pocket into the second from the right connection.
Insert incoming white wire (neutral) for the bottom pocket into the third from the right connection.
Insert incoming black wire (L1) for the bottom pocket into the far left hand connection.
Insert both incoming green wires (ground) into the copper lug.
Tighten strain relief screws assuring to leave a 1/2 of slack in the box.
Replace electrical box plate by inserting 3 screws previously removed.
120 Application with Neutral
113284-1 Maytag Co. 11
Page 12
Gas Information _______________________
!
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shutoff valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure
gas pressure does not exceed 13 water column. Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Type of Gas
This dryer is equipped for use with natural gas. It is design­certified by CSA International for L.P. (propane and butane) gases with appropriate conversion (see below). No attempt shall be made to convert the dryer from the gas specified on the serial/rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician.
MLG52 L.P. Conversion Kit: 887297
It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination. In the absence of such codes, all plumbing connections, materials, and workmanship must conform to the applicable local requirements. In the USA this is the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGAB149.2-M91 (L.P. Gas) or LATEST EDITION.
It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of all the appliance Btu being supplied.
For ease of service, the individual gas supply line of each pocket must have its own manual shutoff valve.
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve, voiding the warranty.
The input ratings shown on the data label are for elevations up to 2,000 feet (610 meters), unless elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (610 meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller who sold the dryer or contact the manufacturer.
IMPORTANT: If connection to this appliance is made with a flexible hose, it must be suitable for the appliance category in accordance with national installation regulations of the country of destination, and if in doubt the installer must contact the supplier. The manufacturer of this appliance does not recommend the use of flexible gas supply line/hose.
In the U.S.A.: An individual manual shutoff valve must be installed within 6 feet (1.8 meters) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.
In Canada: An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within 6 feet (1.8 meters) of the dryer.
Gas Connections
Inlet connection .....1/2 N.P.T.
Inlet supply size .....1/2 Diameter Pipe (minimum)
Piping / Connections
The dryer is provided with two 1/2 N.P.T. inlet pipe connections (1 for each tumbler) at the rear of the dryer. If a separate feed is provided for each tumbler from the main supply line (header), then a 1/2 (12.7 mm) line connection is sufficient. However, if the top and bottom tumbler connections are connected together, the supply from the header must be increased to 3/4 (19.05 mm). There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing. It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servicing.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy.
12 Maytag Co. 113284-1
Page 13
NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.
TYPICAL NATURAL GAS INSTALLATION
TYPICAL L.P. GAS INSTALLATION
Consistent gas pressure is essential at all gas connections. It is recommended that a 3/4 (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 13.0 in WC (32.34 mb) pressure.
A plugged tap, accessible for a pressure gauge connection, must be installed in the main gas supply line immediately upstream of the dryers.
IMPORTANT: Pipe joint compounds that resist the action of natural, L.P., and butane gases must be used.
Test all connections for leaks by brushing on a soapy water solution (liquid detergent works well).
Gas Pressure Test Procedure
!
WARNING
Electric Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. Failure to do so can result in death or electric
shock.
1. Disconnect power to the dryer.
2. Turn off gas supply using the shutoff valve that supplies the dryer.
3. Remove the access panel from the dryer.
4. Turn gas cock in gas supply line to “OFF” position.
5. Install pressure tap and attach manometer.
6. Turn gas cock to “ON” position.
7. Turn on gas supply using the shutoff valve that supplies the dryer and reconnect the power.
8. Start the dryer in Heat Mode and wait for ignition.
9. Record the manometer reading.
10. Once test is complete, disconnect power to the dryer, turn gas cock to OFF position. Remove manometer. Tighten screw inside the pressure tap or install plug.
11. Turn gas cock to ON position and check for leaks with soap solution.
12. Reinstall the access panel.
13. Repeat for other pocket.
14. Reconnect the power.
Heat Input / Gas Consumption / Orifice (Injector) Data
GAS SPECIFICATIONS FOR CSA APPROVED 60 HZ DRYERS
Gas Type and
Nominal Heating Value
Btu/ft
Natural 1,000 7.0-13.0 110,000 *Liquid Propane 2,500 11.0 110,000
Shaded areas are stated in metric equivalents
* Gas valves internal regulator disabled. ** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
113284-1 Maytag Co. 13
Supply
Pressure
3
in WC Btu/hr kW DMS mm in WC
Gross Heat Input
per Pocket / Tumbler
32.23
32.23
**Orifice Size
22 44
3.988
2.184
Orifice
(Injector) Qty.
per Pocket/
Tumbler
23.0 210
Burner
Pressure
Page 14
Preparation for Operation / Start-Up _
The following items should be checked before attempting to operate the dryer:
Read all WARNING and DIRECTION labels attached to the dryer.
Check incoming supply voltage to ensure that it is the same as indicated on the data label.
Ensure that all gas shutoff valves are in the open position.
Ensure all back panels (guards) and electric box covers are in place.
Ensure the service doors are closed and securely in place.
Ensure the lint door/drawer is securely in place.
Rotate the tumbler (drum) by hand to ensure it moves
freely.
Check bolts, nuts, screws, terminals, and fittings for tightness and security.
Check that the vent is connected to the dryer and is exhausted to the outdoors.
Preoperational Test __________________
All dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
Turn on electric power to the dryer. Refer to the operating instructions below for starting your
particular model dryer. Open all shutoff valves. When a gas dryer is first started (during initial start-up), it
has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.
NOTE: During the purging period, check to be sure that all gas shutoff valves are open.
Tumbler Coating
The tumbler is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating.
Microprocessor Programs / Selections
Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used parameter (program) selections. If computer program changes are required, refer to the computer programming manual which was shipped with the dryer.
Operating Instructions _______________
IMPORTANT: For more detailed information regarding the microprocessor controller (computer), refer to the microprocessor user’s manual included with the dryer.
Microprocessor Controller (Computer)
When the microprocessor controller (computer) is in the ready state, the L.C.D. screen will display To Start Insert $XX.XX”.
Insert coin(s). Once the correct Amount to Start has been inserted, the L.C.D. will display Select Cycle”.
Select temperature by pressing HEAVY DUTY, NORMAL, or DELICATE. The cycle will start and the L.C.D. will display the Dry Cycle selected and the remaining time.
The dryer will continue through the drying and cooling cycles, until the vended time has expired.
NOTE: To stop the dryer, open main door. Continuation of the cycle will resume only after the door has been closed and any one of the three temperature selections is pressed.
Shutdown Instructions _______________
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
Discontinue the fuel supply: close external gas shutoff valve. Also close internal gas shutoff valves.
Service / Parts Information __________

Service

Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the Maytag distributor from whom the equipment was purchased. If the distributor cannot be contacted or is unknown, contact the Maytag Co. for a distributor in your area.
NOTE: When contacting the Maytag Co., be sure to give them the correct model number and serial number so that your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the distributor from whom the Maytag equipment was purchased. If the distributor cannot be contacted or is unknown, contact the Maytag Co. for a distributor in your area.
NOTE: When ordering replacement parts from the Maytag distributor or the Maytag Co. be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner.
14 Maytag Co. 113284-1
Page 15
Routine Maintenance _________________

Cleaning

A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper airflow. The accumulation of lint can restrict this airflow.
NOTE: Suggested time intervals shown are for average usage, which is considered 6 to 8 operational (running) hours per day.
Suggested Cleaning Schedule
Every Third or Fourth Load
Clean the lint screen every third or fourth load. A clogged lint screen will cause poor dryer performance. The lint door/ drawer is located just below the loading door of the dryer. Open the lint door/drawer, brush the lint off the lint screen, and remove the lint. Inspect lint screen and replace if torn.
NOTE: To remove the lint drawer from the dryer, pull the drawer out loosen the TORX rails. This allows the metal clips to rotate and allow the drawer to be fully removed. Reverse the above process for installation.
®
screws on the sides of the
Every 6 Months
Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryers internal exhaust ducting.
NOTE: Do not obstruct the flow of combustion and ventilation air. Check back draft dampers in the exhaust ductwork. Inspect and remove any lint accumulation, which can cause the damper to bind or stick.
A back draft damper that is sticking partially closed can result in slow drying and shutdown of heat circuit safety switches or thermostats.
When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the cleaning of appliances is recommended.

Adjustments

7 Days After Installation and Every 12 Months Thereafter
Inspect bolts, nuts, screws, setscrews, grounding connections and nonpermanent gas connections (unions, shutoff valves, and orifices). Belts should be examined. Cracked or seriously frayed belts should be replaced. Complete an operational check of controls and valves. Complete an operational check of all safety devices (lint door/drawer switch, door switches, sail switch, and hi-limit thermostats).
IMPORTANT: The frequency of cleaning the lint screen can best be determined from experience at each location.
Weekly
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor area.
90 Days
!
WARNING
Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical
shock.
NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.
Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.
Clean any lint accumulation in and around the motor(s) casing opening.
NOTES _____________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
113284-1 Maytag Co. 15
Page 16
Data Label Information _______________
Standard Label
NOTES _____________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the upper left rear of the dryer behind the back guard.
1. Model Number – This describes the style of dryer and
type of heat (gas, electric, or steam).
2. Serial Number – Allows the manufacturer to gather
information on your particular dryer.
3. Type of Heat – This describes the type of heat for your
particular dryer, gas (either natural gas or L.P. gas), electric, or steam.
4. Heat Input (For Gas Dryers) – This describes the heat
input in British thermal units per hour (Btu/hr) or kilowatts (kW).
5. Orifice Size (For Gas Dryers) – Gives the number drill
size used.
6. Electric Service – This describes the voltage and current
rating for a particular model.
7. Gas Manifold Pressure (For Gas Dryers) – This
describes the manifold pressure taken at the gas valve tap.
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
Part No. 113284 1 - 12/11/12
____________________________________________________________
Loading...