Front-Loading Automatic Washer
27"
(686 mm)
50¼"
(1276 mm)
36"
(914 mm)
30½"
(775 mm)
1"
(25 mm)
1"
(25 mm)
37" min.
(939 mm)
27"
(686 mm)
DC
30" min.
(762 mm)
28" min.
(710 mm)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
4"
(102 mm)
30½"
(775 mm)
48 in.
2
*
(310 cm
2
)
24 in.
2
*
(155 cm
2
)
14"* max.
(356 mm)
48 in.2 *
(310 cm
2
)
3" (76 mm)
12" (305 mm)
72"
(1829 mm)
27"
(686 mm)
3" (76 mm)
1" (25 mm)
5¼"**
(133 mm)
1"***
(25 mm)
1"***
(25 mm)
24 in.
2
*
(155 cm
2
)
7" (178 mm)
9"
(229 mm)
7" (178 mm)
4"
(102 mm)
31½"
(800 mm)
27"
(686 mm)
1"
(25 mm)1"(25 mm)
1"
(25 mm)
1"
(25 mm)
30½"
(775 mm)
1"
(25 mm)
1"
(25 mm)
27"
(686 mm)
4"
(102 mm)
14"* max.
(356 mm)
PRODUCT MODEL NUMBERS
MHWZ400T, MHWZ600T
Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical supply is required. A time-delay fuse
or circuit breaker is recommended. It is recommended
that a separate circuit serving only this washer be
provided.
Drain System Options
Standpipe drain system - wall or oor (views A & B)
The standpipe drain requires a minimum diameter
standpipe of 2" (50 mm). The minimum carry-away
capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (762 mm)
high and no higher than 96" (2.4 m) from the bottom
of the washer.
OVERALL DIMENSIONS
Washer dimensions
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
Custom undercounter installation-washer only
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L)
capacity. The top of the laundry tub must be
at least 30" (762 mm) above the oor.
Floor drain system (view D)
The oor drain system requires a siphon break that
may be purchased separately. See “Tools and Parts.”
The siphon break must be a minimum of 28" (710 mm)
from the bottom of the washer. Additional hoses might
be needed.
*** Min. top and bottom air openings for closet door.
*** External exhaust elbow requires additional space.
*** Wall, door and oor molding may require additional spacing.
For cabinet installation, with a door, the minimum ventilation openings in the top
are required.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Ref. W10285612
12/2009