Maytag MGT8800FZ User Manual

30" (76.2 cm) Freestanding Gas Range
A
C
B*
PRODUCT MODEL NUMBERS
MGT8720D
MGT8800F
MGT8820D
GAS SUPPLY REQUIREMENTS
Gas supply line:
■ Provide a gas supply line of
location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.
Flexible metal appliance connector:
■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122
to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
1
■ A
/2" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the
range.
■ Must include a shut-off valve:
The supply line must be equipped with a manual shut-off valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shut-off valve. The valve is for turning on or shutting off gas to the range.
3
/4" (1.9 cm) rigid pipe to the range
B
A. Gas supply line B. Shut-off valve “open” position C. To range
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
PRODUCT DIMENSIONS
C**
A
D
F
A. 353/4" ± 1/8" (90.8 ± 0.3 cm)
cooktop height (minimum) with leveling legs screwed all the way in
B. Model/serial/rating plates
(located behind the control panel)*
* Model/serial/rating plates may be rotated up from behind the control
panel for viewing from the front of the range.
** Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
*** Excludes handle. Dimension given is from wall to front of oven door
and will vary based on electrical outlet receptacle installation.
C. 471/8" ± 1/8" (119.7 ± 0.3 cm)
overall height (minimum) with leveling legs screwed all the way in**
D. 281/2" ± 1/4" (72.4 ± 0.6 cm)
depth with handle
E. 261/8" to 271/4" ± 1/8"
(66.4 ± 0.3 cm)***
F. 2915/16" ± 1/16" (76.0 ± 0.2 cm)
width
E***
Type of Gas
Natural gas:
This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
†®TEFLON is a registered trademark of Chemours
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
Ref. W10526071B
09/26/2016
ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in accordance
with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop.
A. 18" (45.7 cm) upper cabinet to countertop B. 13" (33.0 cm) upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to the top of the cooktop, see NOTE. E. 30" (76.2 cm) min. opening width F. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material. G. Cabinet door or hinges should not extend into the cutout. H. 3" (7.6 cm) distance from wall I. 11/2" (3.8 cm) min. from right side cabinet J. 8" (20.3 cm) width K. 7" (17.8 cm) min. from floor L. 2" (5.1 cm) min. from floor
* Drill on centerline 11/4" (3.1 cm) from rear wall for gas supply line.
** Gas lines must be installed within the shaded area to ensure proper
alignment of this oven with cabinets.
*** Electrical plugs must be installed within the shaded area to ensure
proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
■ A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
■ Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
B
D
C
A
E
F
J
I
K
L
G
H
8½"
(21.6 cm)
14"
(35.6 cm)
***
1½"
(3.8 cm)
1¼"*
(3.2 cm)
8½" (21.6 cm)**
gas line location
2¼" (5.7 cm)
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 2 of 2
Ref. W10526071B
09/26/2016