30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
MGR5605W
TYPE OF GAS
Natural gas:
This range is design-certified by CSA International for use with Natural gas or,
after proper conversion, for use with LP gas.
• This range is factory set for use with Natural gas. See “Gas Conversions”
section. The model/serial rating plate located on the oven frame behind the left
side of the broiler door has information on the types of gas that can be used. If
the types of gas listed do not include the type of gas available, check with the
local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be
made to convert the appliance from the gas specified on the model/serial rating
plate for use with a different gas without consulting the serving gas supplier. See
“Gas Conversions” section.
GAS SUPPLY LINE
• Provide a gas supply line of
3
⁄4" (1.9 cm) rigid pipe to the range location. A
smaller size pipe on longer runs may result in insufficient gas supply. With LP
gas, piping or tubing size can be
1
⁄2" minimum. Usually, LP gas suppliers
determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do
not use TEFLON
®†
tape.
Flexible metal appliance connector:
• If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm)
long,
1
⁄2" (1.3 cm) or 3⁄4" (1.9 cm) I.D., flexible metal appliance connector maybe
used for connecting range to the gas supply line.
•A
1
⁄2" (1.3 cm) male pipe thread is needed for connection to the female pipe
threads of the inlet to the appliance pressure regulator.
• Do not kink or damage the flexible metal tubing when moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an inline connection to the range. The rigid pipe must be level with the range
connection. All strains must be removed from the supply and fuel lines so range
will be level and in line.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10477535A
9/17/13
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp fused, electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit serving
only this range be provided.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Page 1 of 2
B
A
C
A. Gas supply line
B. Shutoff valve “open” position
C. To range
26 3/4"
(67.9 cm)
1
/4"
24
(61.6 cm)
7
/8"
29
(75.9 cm)
36"
(91.4 cm)
1
46
/4"
(117.5 cm)
CABINET OPENING DIMENSIONS
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10477535A
9/17/13
Cabinet opening dimensions shown are for 25"
(64.0 cm) countertop depth, 24" (61.0 cm) base
cabinet depth and 36" (91.4 cm) countertop
height.
*NOTE: 24" (61.0 cm) minimum when bottom of
wood or metal cabinet is protected by not less
than
1
⁄4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet
steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top
of the cooking platform and the bottom of an
unprotected wood or metal cabinet.
IMPORTANT: If installing a range hood or
microwave hood combination above the range,
follow the range hood or microwave hood
combination installation instructions for
dimensional clearances above the cooktop
surface.
B
D
C
A
E
M
L
I
H
F
G
G
J
K
K
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*.
E. 30¹⁄₈" (76.5 cm) min. opening width
F. This shaded area recommended for installation of rigid gas
pipe.
G. 8" (20.3 cm)
H. Grounded outlet
I. 17" (43.2 cm)
J. 4¹⁄₂" (11.4 cm)
K. 2" (5.1 cm)
L. 2" (5.1 cm) min. clearance from both sides of range to side
wall or other combustible material.