Maytag MGR4451ADB, MGR4451ADQ Installation Guide

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE
INSTALLATION MANUAL
'Gas 30-inch Wide Free-standingRange
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE.
CLEARANCE DIMENSIONS
Range may be installed with zero inches clearance
Only qualified personnel should install or service this range.
Read "Safety Instructions" in the
Improper installation, adjustment, alteration, service, maintenance or
use of range can result in serious injury or property damage.
adjacent to (against) combustible construction at the rear and on the sides below the cooktop. For complete
information in regard to the installation of wall cabinets above the range and clearances to combustible wall
above the cooking top see the installation drawings. For SAFETY CONSIDERATIONS do not install a range in any
combustible cabinetry which is not in accord with the installation drawings.
* NOTE: 30 inch (76.2 cm) dimension between cooking top and wall cabinet shown on illustration does not apply
to ranges with an elevated oven. The 36 inch (76.2 cm) dimension may be reduced to not less than 24 inches (61
cm) when the wall cabinets in a domestic home are protected with fireproof materials in accordance with
American National Standards - National Fuel Gas Code or in mobile homes when they are protected with fireproof
materials in accordance with the Federal Standard for Mobile Home Construction and Safety.
WARNING
ALL RANGES CAN TIP AND CAUSE INJURIESTO PERSONS.
INSTALL ANTI-TIP DEVICES PACKED WITH RANGE.
FOLLOW ALL INSTALLATION INSTRUCTIONS.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a minimum of 5 inches (13 cm) beyond the bottom of the
cabinets.
CAUTION: This range has been designed in
accordance with the requirements of various safety agencies and complies with the maximum allowable
wood cabinet temperatures of 194°F. If this range is installed with cabinets that have a lower working
temperature than 194°F, discoloration, delamination or melting may occur.
8101 P624-60
(12-03-00)
INSTALLATION DRAWINGS
GAS LINE
LOCATION NON-SELF
CLEANING MODELS.
-PROVIDE FOR 120 VOLT GROUNDED ELECTRICAL
OUTLET IN THIS AREA. OUTLET MUST BE FLUSH.
AREA IS 13"W X 9"H,
(33 CM L X 22.9 CM H)
LOCATED 9 3/8" (23.8 CM) ABOVE FLOOR, AND 1 1/2 °
(3.8 CM) FROM RIGHT
WALL.
36" (91.4 CM)
HEIGHT OF CABINET
///_30" (76_2 CM)
| / CABINET
RECOMMENDED GAS LINE
LOCATION SELF-CLEAN
25"(63.5 CM)
NORMAL CABINET
TOP DEPTH
OPENING
MODELS.
ALLOWED 18°(45.7 CM)
FOR NON-CONVECT MODELS.
-2-
ANY COMBUSTIBLE
/
/
(76.2 CM)| |j
30" (76.2 CM). LI
j MIN. "e_4_
_(SEE NOTE ON FRONT PAGE) I _ _
(45.7 cM) [ / {
o col,
iI '
SURFACE
P
MAX. DEPTH OF CABINETS ABOVE COOK TOP
0"(0 CM) CLEARANCE
_BETWEEN ADJACENT /_---.,. COMBUSTIBLE
CONSTRUCTION AND THE BACK AND SIDES OF THE RANGE
BELOW THE COOKING SURFACE.
36"
(91 .4 CM)
ART _9215-143-0
DIMENSION "A" SIDE CLEARANCE ABOVE COOKING SURFACE
TOP BURNER RATE FOR
NATURAL GAS (SEE RATING PLATE) CONVENTIONAL OVEN SELF-CLEAN OVEN
9,200 BTU/HR OR LESS 0 INCHES 3 INCHES (7.6 CM)
MORE THAN 9,200 BTU/HR 1 INCH (2.5 CM) 3 INCHES (7.6 CM)
Check the range model number plate to see if the range is approved for installation in mobile homes and/or
recreational park trailers. If approved the following items are applicable.
RECREATIONAL PARK TRAILERS
The installation of a range designed for recreational park trailers must conform with state or other codes or, in the
absence of such codes, with the Standard for
Recreational Park Trailers, ANSI A119.5-latest edition.
MOBILE HOMES
The installation of a range designed for mobile home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24 HUD, (Part 280)] or, when such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA
501A, or with local codes.
In Canada the range must be installed in accordance with
the current CSA Standard C22.1 - Canadian Electrical Code Part 1 and Section Z240.4.1 - Installation
Requirements for Gas Burning Appliances in Mobile Homes (CSA Standard CAN/CSA - Z240MH).
In Canada the range must be installed in accordance with
CAN/CSA - Z240.6.2 - Electrical Requirements for R.V.'s (CSA Standard CAN/CSA - Z240 RV Series) and Section
Z240.4.2 - Installation Requirements for Propane Appliances and Equipment in R.V.'s (CSA Standard
CAN/CSA - Z240 RV Sedes).
LOCATING THE RANGE
Do not set range over holes in the floor or other locations
where it may be subject to strong drafts. Any opening in the wall behind the range and in the floor under the range
should be sealed. Make sure the flow of cooling/ ventilation air is not obstructed below the range.
NOTE: A range should NOT be installed over kitchen carpeting.