29" Wide Models Dryer Dimensions
(737 mm)
(737 mm)
Gas Dryer
27" Wide Models Dryer Dimensions
27"
(686 mm)
433/8"
(1102 mm)
1
/2"
(13 mm)
433/8"
(1102 mm)
11/2"
(38 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of
3.8 cu. ft. capacity washer).
133/4"
223/4"
(578 mm)
273/4"
(705 mm)
273/4"
(705 mm)
A. Wide opening side-swing door B. Wide opening hamper door
Installation Spacing
3"* (76 mm)
3"* (76 mm)
18"* (457 mm)
1" (25 mm)
29"
(737 mm)
A
1"*
1"
(25 mm)
(25 mm)
14" max.* (356 mm)
27¾"
(705 mm)
B
2
48 in. (310 cm )
24 in.
(155 cm )
*
2
2
*
2
C
223/4"
(578 mm)
291/2"
(749 mm)
A. Wide opening side-swing door B. Wide opening hamper door
Installation Spacing
18"* (457 mm)
27"
(686 mm)
1" (25 mm)
A. Recessed area B. Side view – closet or conned area C. Closet door with vents
1" (25 mm)
*Required spacing
1"* (25 mm)
(749 mm)
(1092 mm)
14" max.* (356 mm)
29
½
"
B
43"
11/2"
(38 mm)
133/4"
(349 mm)
48 in.
(310 cm )
5½"*
(140 mm)
2
*
2
24 in.
(155 cm )
(749 mm)
2
*
2
291/2"
(76 mm)
3"*
(76 mm)
*Required spacing
A. Recessed area B. Side view – closet or conned area C. Closet door with vents
W10562360A
12/2014
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of installation
and servicing.
■ Additional clearances might be required for wall, door, and oor
moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.