Maytag MGDX5SPAW0 Installation Guide

GAS DRYER
iNSTALLATiON iNSTRUCTiONS
27" Wide Models
INSTRUCCIONES
DE INSTALACION DE LA SECADORA
Modelos
DRYER SAFETY ................................................................ 2
iNSTALLATiON REQUIREMENTS .................................... 4
Tools and Parts .................................................................... 4
Location Requirements ...................................................... 5
Install Leveling Legs ........................................................... 6
GAS DRYER POWER HOOKUP ................................................. 6
Gas Supply Requirements .................................................. 6
Electrical Requirements ..................................................... 8
VENTING ...................................................................................... 8
Venting Requirements ......................................................... 8
Plan Vent System ................................................................. 9
Venting Kits ........................................................................ 10
install Vent System ............................................................ 11
Make Gas Connection ...................................................... 11
Connect Vent ..................................................................... 11
LEVEL DRYER ........................................................................... 12
COMPLETE iNSTALLATiON CHECKLIST ............................... 12
REVERSE DOOR SWING (OPTIONAL} .................................... 13
TROUBLESHOOTING ............................................................... 18
de 27"
SEGURIDAD DE LA SECADORA .................................. 19
REQUISITOS DE INSTALACION ................................... 21
CONEXION DE ENERGIA DE LA SECADORA A GAS ........... 24
VENTILACION .......................................................................... 26
NIVELACION DE LA SECADORA ............................................ 30
LISTA DE CONTROL DE LA INSTALACION TERMINADA .... 31
CAMBIO DEL SENTIDO DE ABERTURA DE LA PUERTA .... 31
SOLUCION DE PROBLEMAS .................................................. 36
a gas
Herramientas y piezas ..................................................... 21
Requisitos de ubicaci6n .................................................. 22
Instaiaci6n de las patas niveladoras .............................. 23
Requisitos del suministro de gas ................................... 24
Requisitos el_ctricos ....................................................... 25
Requisitos de ventiiaci6n ................................................ 26
Planificaci6n del sistema de ventilaci6n ........................ 27
Juegos de ventilaci6n ...................................................... 28
Instalaci6n del sistema de ventilaci6n ........................... 29
Cone×ibn del suministro de gas ..................................... 29
Conexi6n del ducto de escape ....................................... 30
iNSTALLATiON NOTES Date of purchase:
Date of installation: Installer:
Model number: Serial number:
W10486878A
NOTAS SOBRE LA INSTALACION Fecha de compra:
Fecha de instalaci6n:
Instalador:
N_mero de modelo: N_mero de serie:
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be kifled or seriously injured if you don't immediately follow instructions,
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING - ...i.kofFi, "
- Clothes dryer installation must be performed by a qualified installer.
- Install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with fle×ible plastic venting materials or flexible metal (foil type) duct. if flexible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire,
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
® Do not try to light any appliance. e Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants. ® Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier. If a gas leak is detected, follow the "What to do if you smell gas" instructions.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry= cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment. [] Do not reach into the dryer if the drum is moving. [] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
SAVE THESE iNSTRUCTiONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user=repair instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber=like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See "Electrical Requirements" located inthe installation
instructionsfor grounding instructions.
3
in the State of Massachusetts, the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE INSTRUCTIONS
iNSTALLATiON
Toomsand Parts
Gather the required tools and parts before starting installation.
Tools needed:
@
Flat-blade screwdriver
1/4" nut driver or socket wrench (recommended)
#2 Phillips screwdriver
Tin snips (new vent
installations)
REQUIREMENTS
Adjustable wrench that opens to 1" (25 mm) or
hex-head socket wrench
Utility knife Putty knife
Caulking gun and compound (for installing new exhaust vent)
Tape measure
Level Pliers
4
Vent clamps
db
8" or 10" pipe wrench
Pipe-joint compound resistant to LP gas
8" or 10" adjustable wrench (for gas connections)
Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts are included.
Parts needed: Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please
reference the "Assistance or Service" section of the Use and Care Guide.
Optional Equipment: (Not supplied with dryer) Refer to your Use and Care Guide for information about
accessories available for your dryer.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector. NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
installation clearances: The location must be large enough to allow the dryer door to
open fully. Most installations require a minimum 51/2"(140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Dryer Dimensions
43" (1092 mm)
11092 turn}
29,?; .29v2,_,
(749 ram} \(749 mm) X "X_'_"_ 27,, _\ _ _\
133A,,
mm)
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (460 mm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need: [] A location allowing for proper exhaust installation.
See "Venting Requirements."
[] A separate 15- or 20-amp circuit for gas dryers. [] If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements."
[] A sturdy floor to support dryer and a total weight (dryer
and load) of 200 Ibs. (90.7 kg). The combined weight of a companion appliance should also be considered.
[] Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
A B
A. Large opening side-swing door B. Wide opening hamper door
installation Spacing
.._ 3I1.
.H_ 1_"i11BX,^ __
I_ II_mm_ ' 48in'_
(310crn)_
... _ _._ (155cml
1"-'_ _- 27"-_ _ 1" -_I"*F 29_/4"H5Y2"*_-
(25rnrn) (686mm) (25mm)_5mm}(74,1mm}(140rnrn)
A B
A. Recessed area
B. Side view - closet or confined area C. Closet door with vents
24i_*,
(76mm)
-T
4f 3II,
(76ram}
*Required spacing
installation spacing for recessed area or closet Thedimensions shown arefor the minimum spacing allowed.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are
acceptable.
[] Companion appliance spacing should also be considered.
5
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
[] Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance or Service" section of the Use and Care Guide.
[] Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
mnstaH Leve in 9 Legs
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
2, Screw in leveling legs
diamond
marking
Examine leveling legs and find diamond marking. Screw legs
into leg holes by hand. Use a wrench to finish turning legs
until diamond marking is no longer visible. Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room to connect the exhaust vent.
For mobile home use Gas dryers must be securely fastened to the floor.
To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
Mobile home installations require a Mobile Home Installation
Hold-down Kit. For ordering information please reference
the Use and Care Guide.
GAS DRYER POWER
HOOKUP
Gas SuppMy Requirements
Explosion Hazard
Use a new CSA International approved gas supply line, Install a shut-off valve.
Securely tighten all gas connections. If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire,
Gas type
Natural gas: This dryer is equipped for use with Natural Gas. It is design-
certified by CSA International for LP (propane or butane) gases with appropriate conversion.
[]
Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, please reference the
"Assistance or Service" section of the Use and Care Guide.
LP gas conversion: Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier.
iMPORTANT: The gas installation must conform with local codes, or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Gas supply line
[] 1/2" NPT pipe is recommended. [] 3/8" approved tubing is acceptable for lengths under
20 ft. (6.1 m) if local codes and gas supplier permit.
[] Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).
[] Must include a shut-off valve:
in the U.S.A.:
An individual manual shut-off valve must be installed
within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.
Option 1 (Recommended Method} Flexible stainless steel gas connector:
[] If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method} Approved aluminum or copper tubing:
[] Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit). [] If you are using Natural Gas, do not use copper tubing. [] 3/8" flare x 3/8" NPT adapter fitting between dryer pipe and
3/8" approved tubing. [] Lengths over 20 ft. (6.1 m) should use larger tubing and a
different size adapter fitting. [] If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON ®t tape.
Dryer gas pipe
[] The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
*53/4" A
(159 rnrn)
The shut-off valve location should be easy to reach for opening and closing.
E
A i
B
A. 3/8" flexible gas connector B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be connected to the gas supply. Listed here are some guidelines
for two different methods of connection. This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard for
connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
1 1/2"
(38 turn)
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m}:
[] The design of this dryer is certified by CSA international for
use at altitudes up to 10,000 ft. (3,048 m), above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation. Elevations above 10,000 ft. (3,048 m):
[] When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation. Gas supply pressure testing
[] The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
?®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
7
EMectrica Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
[]
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
VENTING
Venting Requirements
Fire Hazard
Use a heavy metal vent, Do not use a plastic vent.
Do not use a metal foil vent, Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
1
_ 4"
4" (102 mm) heavy metal exhaust vent
[] Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used. [] Do not use plastic or metal foil vent.
Rigid metal vent: [] Recommended for best drying performance and to avoid
crushing and kinking. Flexible metal vent: (Acceptable only ifaccessible to clean)
[] Must be fully extended and supported in final dryer location. [] Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance. [] Do not install in enclosed walls, ceilings, or floors. [] The total length should not exceed 73/4ft. (2.4 m). NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review "Vent System Chart" and, if necessary, modify existing vent system to achieve best drying
performance.
(102 ram)
Exhausthoods:
[] Must be at least 12" (305 ram) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended St_vies:
P(an Vent System
Recommended exhaust installations
_HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH_
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
Louveredhood
Box hood
Acceptable Style:
Angled hood
Elbows: [] 45° elbows provide better airflow than 90° elbows.
............. Bet
A. Dryer B. Elbow
C, Wall D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows
H.Exhaust outlet
L Optional side exhaust outlet
Optional exhaust installations:
27" Wide Models can be converted to exhaust out the right side,
left side, or through the bottom (4-way vent kit). Each kit includes
step-by-step instructions. For ordering information, see "Venting
Kits."
?
Clamps: [] Use clamps to seal all joints.
[] Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
Improper venting can cause moisture and lint to collect indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
See "Venting Kits" for more information.
Fire Hazard
Cover unused exhaust holes with a manufacturer's exhaust cover kit.
Contact your local dealer. Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
B C
A. Standard rear offset exhaust installation B. Left- or right-side exhaust instaflation
C. Bottom exhaust instaflation
9
A(ternate installations for close clearances Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1-800-901-2042, or visit us at www.applianceaccessories.com.
Part Number Description
8171587RP 0-5" Metal vent periscope 4396037RP 0"-18" Metal vent periscope 4396011 RP 18"-29" Metal vent periscope
4396014 29"-50" Metal vent periscope 4392892 In-Wall metal DuraVent TM Periscope
W10470674 4-way vent kit - universal grey 4396028 Sure Connect TM venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, flexible dryer venting 4396010RP 6' SecureConnect TM vent, flexible dryer venting
4396013RB Dryer vent installer's kit 4396033RP 5' flexible dryer venting with clamps
4396727RP 8' flexible dryer venting with clamps 4396004 Dryer offset elbow
4396005 Wall offset elbow 4396006RW DuraSafe TM close elbow
4396007RW Through-the-wall vent cap 4396008RP 4" steel dryer venting clamps - 2 pack
8212662 Flush mounting Iouvered vent hood 4"
10
Special provisions for mobile home installations: The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
[] Select route that will provide straightest and most direct path
outdoors.
[] Plan installation to use fewest number of elbows and turns. [] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking. [] Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
[] Use following "Vent System Chart" to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in "Vent System Chart." Exhaust systems longer than those specified will:
[] Shorten life of dryer. [] Reduce performance, resulting in longer drying times and
increased energy usage.
The "Vent System Chart" provides venting requirements that will help achieve best drying performance.
Vent System Chart
Number of Type Box/Iouvered Angled 90 ° turns or of vent hoods hoods
elbows
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
:2. Plan pipe fitting connection
A
12" rain.
(305 ram)
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.
A. 3/8" flexible gas connector C. 3/8" to 3/8" pipe elbow
B
B. 3/8" dryerpipe D. 3/8" pipe-to-flare adapter fitting
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
f
C
3. Open shut=off valve
c,o
pen valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
Make Gas Connection
1, Connect gas supply to dryer
Flared Non-flared
male fitting male fitting
Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks. NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON ®ttape.
1®TEFLON is aregistered trademark of E.I. Dupont De Nemours and Company. 1 1
Using a4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.