Maytag MGDE500VF, MGDE500VS, MGDE500VP, MGDE500VE Dimension Guide

BA
1"
(2.5 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
5"**
(12.7 cm)
27"
(68.6 cm)
31½"
(80 cm)
18" min.* (45.72 cm)
14" max.* (35.6 cm)
A. Recessed area B. Side view – closet or confined area
* Required spacing
** Side or bottom venting – 0" (0 cm) spacing is allowed
A
B
14" max.* (35.6 cm)
18" min.* (45.72 cm)
1"*
5"**
(12.7 cm)
31½"
(80 cm)
48 in.
2*
(310 cm2)
24 in.
2*
(155 cm2)
3"*
(7.6 cm)
3"*
(7.6 cm)
(2.5 cm)
A. Side view – closet or confined area B. Closet door with vents
* Required spacing
** Side or bottom venting – 0" (0 cm) spacing is allowed
38"
(96.52 cm
)
*31½" (80 cm)
27"
(68.6 cm)
51½"
(130.81 cm)
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
MGDE500V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10057352
07-28-08
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
Dryer only
Dryer on pedestal
Electrical: 120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
Exhaust venting: Exhaust your dryer to the outside. 4" (10.16 cm) diameter vent is required. Rigid or flexible heavy metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.
Gas supply: This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.
Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer.
1/2" IPS pipe is recommended. 3/8" approved aluminum or copper tubing is acceptable
for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.
If you are using Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting. If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
®
tape.*
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.
This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
An individual manual shutoff valve must be installed within six (6) feet (1.8m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
*®TEFLON is a registered trademark of E.I. Dupont De
Nemours and Company
Dryer gas pipe: The gas pipe that comes out through the rear of your dryer has a 3/8" male thread.
NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (25.4 cm) or 15.5" (39.4 cm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (46 cm) from the floor.
For cabinet installation, with a door, the minimum ventilation openings in the top of the cabinet are required.
Gas Dryer
* Most installations require a minimum 5”
(12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See Use and Care Guide, “Venting Requirements.”
Page 1 of 2
7"* (17.8 cm)
9"* (22.9 cm)
7"* (17.8 cm)
5"**
(12.7 cm)
31
"
(80.0 cm)
27"
(68.6 cm)
1"* (2.5 cm)
1" 1"
(2.5 cm)
(2.5 cm)
* Required spacing
** Side or bottom venting – 0" (0 cm) spacing is allowed
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLATION
A. ½" NPT gas supply line
B.
3
/8 NPT dryer pipe
A
B
*6¼" (15.9 cm)
1½" (3.8 cm)
PRODUCT MODEL NUMBERS
EXHAUST VENTING
MGDE500V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10057352
07-28-08
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER AND DRYER
UNDERCOUNTER INSTALLATION
Dimensions shown are for recommended spacing.
0"
(0 cm)
1"* (2.5 cm)
1"* (2.5 cm)
38" min. (96.52 cm)
27" (68.6 cm)
A . Louvered hood style
B . Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
4"
(10.2 cm)
2-1/2"
(6.4 cm)
Dimensions shown are for minimum spacing.
Recommended hood styles
Angled hood style is
acceptable.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Gas Dryer
Page 2 of 2
48 in.2 *
(310 cm
2
)
3"* (7.6 cm)
3"* (7.6 cm)
1"* (2.5 cm)
24 in.
2
*
(155 cm
2
)
* Required spacing
6"* (15.2 cm)
76"
(193 cm)
27"
(68.6 cm)
5"*
(12.7 cm)
1"
(2.5 cm)
1"
(2.5 cm)
* Required spacing
Number of 90° turns or elbows
NOTE:
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Type of vent
0Rigid metal
Flexible metal
1Rigid metal
Flexible metal
2Rigid metal
Flexible metal
3Rigid metal
Flexible metal
4Rigid metal
Flexible metal
Side and bottom exhaust installations have a 90° turn
Box or Louvered hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)