GAS DRYER INSTALLATION INSTRUCTIONS
CANADIAN ELECTRIC DRYER INSTRUCTIQNS
INSTRUCTIONS POUR L'INSTALLATION DE LA SECHEUSE
GAZ (I_.-U. ET CANADA)
ET I_LECTRIQUE (CANADA UNIQUEMENT)
Table of Contents
DRYER SAFETY ................................................................ 2
iNSTALLATiON REQUIREMENTS .................................... 4
Tools and Parts .................................................................... 4
Location Requirements ...................................................... 5
Electric Dryer Power Hookup-Canada Only ..................... 7
Gas Dryer Power Hookup ................................................... 8
iNSTALLATiON iNSTRUCTiONS .............................................. 10
Venting Requirements ....................................................... 10
Plan Vent System ............................................................... 11
install Vent System ............................................................ 12
install Leveling Legs ......................................................... 12
Make Gas Connection ...................................................... 13
Connect inlet Hose ............................................................ 13
Connect Vent ..................................................................... 15
Level Dryer ......................................................................... 15
Complete installation Checklist ....................................... 16
Door Reversal .................................................................... 16
Troubleshooting ................................................................. 16
iNSTALLATiON NOTES
Date of purchase:
Date of installation:
installer:
Model number:
Serial number:
Table des mati_res
S¢:CURIT¢: DE LA S¢:CNEUSE ....................................... 17
EXIGENCES D'INSTALLATION ...................................... 19
Outillage et pi_ces ............................................................ 19
Exigences d'emplacement ............................................... 20
Raccordement a I'alimentation _lectrique de
la s_cheuse Nectrique - Canada seulement ................. 22
Raccordement d'une s_cheuse _ gaz ............................. 23
iNSTRUCTiONS POUR L'INSTALLATION ............................... 25
Exigences concernant I'_vacuation ................................ 25
Planification du syst_me d'6vacuation ........................... 26
installation du circuit d'6vacuation ................................. 27
installation des pieds de nivellement .............................. 28
Raccordement au gaz ....................................................... 28
Raccordement du tuyau d'arriv6e d'eau ......................... 29
Raccordement du conduit d'6vacuation ......................... 30
R6glage de I'aplomb de la s6cheuse ............................... 31
Achever I'installation - liste de v6rification ..................... 31
inversion de la porte ......................................................... 32
D6pannage ......................................................................... 32
NOTES CONCERNANT L'INSTALLATION
Date d'achat :
Date d'installation :
Installateur :
Num6ro de module :
Num_ro de s6rie :
W10240584B
W10240585B=SP
DRYER S_ETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen ifthe instructions are not followed.
WARNING - "Risk of Fire"
- Clothes dryer installation must be performed by a qualified installer.
- Install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with flexible plastic venting materials, if flexible metal
(foil type} duct is installed, it must be of a specific type identified by the appliance
manufacturer as suitable for use with clothes dryers. Flexible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct
clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
2
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
= Do not try to light any appliance.
= Do not touch any electrical switch; do not use any phone in your building.
= Clear the room, building, or area of all occupants.
= Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
[] installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be aT-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
INS LATION REQUIREMENTS
TOOLS P TS
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
8" or 10" pipe wrench 8" or 10" adjustable wrench
(for gas connections)
Flat-blade screwdriver
Wire stripper (direct wire
installations)
1/4" nut driver
recommended)
#2 Phillips screwdriver
Tin snips (new vent
installations)
@
Vent clamps
Pipe-joint compound
resistant to LP gas
Parts supplied {all models):
Leveling legs (4)
Parts supplied {steam models):
&
Tape measure Pliers
Level
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
4
Caulking gun and compound
(forinstalling new exhaustvent)
Utility knife
G
"Y" connector Short inlet hose
Long inlet hose
Parts package is located in dryer drum. Check that all parts
are included.
NOTE: If installing dryer on pedestal, do not use leveling legs.
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about
accessories available for your dryer.
Rubber washer
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation.
See "Venting Requirements."
[] If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
[] Floor must support dryer weight of 200 Ibs. (90.7 kg).
Also consider weight of companion appliance.
[] Cold water faucets located within 4 ft. (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (137.9-689.6 kPa).
You may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
[] 20-100 psi (138-690 kPa) for best performance.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
[] For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
For each arrangement, consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or Iouvered door is installed, top and bottom air openings
in door are required.
DRYER DiMENSiONS
Front view:
353/8"
(899 mm}
3/4"
(18ram}
Side view:
29"
(736 rnrn}
27"
(686rnm)
_'lD-
ooo
3 1/2""
(89ram}
o
o
Optional side ."
exhaust vent
/
location ".
6 7/8"
(175 mm)
\
z
Backview: Closet installation {dryer only):
61/4"
(159 ram)
m
f
Electric
T
281/8 '"
(715 ram)
J
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See "Venting
Requirements."
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45° F (7° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
31/2 ""
(89 ram)
+
+
34" recommended
(864 ram}
I
18" rain.
(25 ram) _
Cabinet installation (dryer only):
3 mm
(76ram)
48 in.2
(310 cm2}
24 in.2
(155cm2)
Installation spacing for recessed area or closet
installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
[]
Additional spacing should be considered for ease of
installation and servicing.
[]
Additional clearances might be required for wall, door, and
floor moldings.
[]
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
[] Companion appliance spacing should also be considered.
6
ClosetInstallation (stacked washer and dryer):
6 mn
ram)
For gas dryers mobile home installations:
[] Mobile Home Installation Hold-down Kit Part Number
346764 is available to order. For further information, see
"Assistance or Service" section in your Use and Care Guide.
3 In
(76ram}
76 "n
48 in?
(310 cm 2)
(1930 mm}
51/2 H
(140 ram%)
(25 mm)
Custom under counter installation (dryer only):
39" rain.
(990 ram}
(25 mm)
(25 mm)
NOTE: Some models not recommended for undercounter
installation.
Mobile home =Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
[] Metal exhaust system hardware, available for purchase
from your dealer. For further information, see "Assistance
or Service" section in your Use and Care Guide.
[]
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as
dryer exhaust opening.
ELECTRIC DR R
FOWER HOOHUF- ONLY
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
it is your responsibility:
[]
Tocontact a qualified electrical installer.
[]
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
[]
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
[]
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall
receptacle is within reach of dryer's final location.
4-wire receptacle (14-30R)
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
Forfurtherinformation,pleasereferenceservicenumberslocated
in"AssistanceorService"sectionofyourUseandCareGuide.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS DR R POWER HOOKUP
ELECTRICAL REQUIREMENTS
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
[]
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram} water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
8
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, contact your dealer
or call the phone numbers referenced in the "Assistance or
Service" section of your Use and Care Guide.
LP Gas Conversion:
iMPORTANT: Conversion must be made by a qualified
technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
GAS SUPPLY LINE
[] Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer.
E
GAS SUPPLY CONNECTION REQUIREMENTS
[] Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe,
as needed to avoid kinking.
[]
Use only pipe-joint compound. Do not use TEFLON _'*_ttape.
[]
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSi Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 10,000 ft. (3,048 m}:
[] When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner Btu rating shown on the model/serial number
plate is required for each 1,000 ft. (305 m) increase in
elevation.
Gas supply pressure testing
[] The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
B
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPTminimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve.
[] 1/2" IPS pipe is recommended.
[] 3/8"approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
[] If you are using Natural gas, do not use copper tubing.
[] Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
[] If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON_'*_ttape.
[] Must include shut-off valve
in the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSi Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) ft. (1.8 m) of
the dryer. The location should be easy to reach for opening
and closing.
DRYER GAS PIPE
[] The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
A
"6¼"
(159 ram)
11/2"
(38 ram}
A. 3/8" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (254 mm) or 15.5" (394 mm) from the
floor, depending on the pedestal model. For a garage installation,
the gas pipe height must be an additional 18" (460 mm) from
the floor.
1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
XNS LATXON XNSTRUCTXON$
NTXNG NEQUXNEMENT$
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
Exhaust hoods:
[] Must be at least 12" (305 ram) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
4" C
(102 m m_"_C_
_4 _ (1°22m)
(102 ram)
Recommended styles:
A, Louvered hood
B. Box hood
Acceptable styles:
C. Angled hood
Elbows:
[] 45° elbows provide better airflow than 90° elbows.
Only a 4" (102 mm) heavy metal exhaust
vent and clamps may be used.
[]
Do not use plastic or metal foil vent.
Rigid metal vent:
[]
Recommended for best drying performance and to prevent
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
[]
Must be fully extended and supported in final dryer location.
[]
Remove excess to avoid sagging and kinking that may
result in reduced airflow and poor performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 7 3/4ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal or
flexible metal vents. Review Vent system chart and if necessary,
modify existing vent system to achieve best drying performance.
Good
Clamps:
[]
Use clamps to seal all joints.
[]
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
Better
10
Vent products can be purchased from your dealer. For more
information, see "Assistance or Service" section in your Use and
Care Guide.