Gas and Electric Dryer
PRODUCT MODEL NUMBERS
MEDB835D, MEDB855D,
MGDB835D, MGDB855D
Side view
(1428 mm)
1
/2"
(13 mm)
Bottom view
56
1
/4"
3213/16"
(821 mm)
(218 mm)
3
11
/8"
(289 mm)
81/2"
Door Opened
Door Closed
4213/16"
(1987 mm)
5
3
/8"
(93 mm)
Back view
29"
(737 mm)
57/8"
(150 mm)
1
4
/2"
(115 mm)
3"
(77 mm)
13/8"
(35 mm)
1
/2"
14
(370 mm)
1
3
/2"
(93 mm)
NOTE: Leveling legs 1/2" (13 mm) (3.6 washer capacity) or
1½" (38 mm) (3.8 washer capacity) depending model.
Minimum Required Spacing
14" max
(356 mm)
3"/3"
18"/18"*
(457 mm)
(76 mm)
48"
(310 cm2)
2
/48"
2
3
14
/8"
(365 mm)
NOTE: Most installations require a minimum
of 6" (152 mm) clearance behind dryer for
exhaust vent with elbow. See
“Venting Requirements.”
Spacing for recessed area or closet installation
The dimensions shown are for the recommended spacing
allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
■ Companion appliance spacing should also be considered.
6"/0"*
(152 mm)
1"/0"*
(25 mm)
2/
24"
(155 cm2)
1"/1"*
(25 mm)
3"/3"
(76 mm)
*Recommended/Minimum spacing
W10725269A
2
24"
01/2015
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS - Gas models only
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
ELECTRICAL REQUIREMENTS - Electric models only
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied
on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent System Charts provide venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
90° elbows
0
1
2
Type of vent Angled
Rigid metal
Rigid metal
Rigid metal
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and
turns.
■ When using elbows or making turns, allow as much
room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
3
4
NOTE: Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn
to the charts.
Rigid metal
Rigid metal
35 ft. (10.7 m)
27 ft. (8.2 m)