Gas Dryer
PRODUCT MODEL NUMBERS
MGDB800V
Gas supply: This dryer is equipped for use with Natural gas.
Dryer can be converted to L.P. gas. When rigid pipe is used
it should be 1/2" IPS. When acceptable to the gas supplier
and local codes, 3/8" approved tubing may be used for
lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1
m), larger tubing should be used. Pipe-joint compounds
resistant to the action of L.P. gas must be used. An
individual manual shutoff valve must be installed within 6
ft (1.8 m) of the dryer in accordance with the National Fuel
Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused
electrical supply is required. A time-delay fuse or circuit
breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be connected
to the cold water faucet using new inlet hoses. Do not use
old hoses. Do not overtighten. Damage to the coupling can
result.
Exhaust venting: Exhaust your dryer to the outside. 4"
(102 mm) diameter vent is required. Rigid or exible metal
exhaust vent must be used. Do not use plastic or metal
foil vet. Exhaust hood must be at least 12" (305 mm) from
the ground or any object that may be in the path of the
exhaust.
Recommended Styles:
Acceptable Style:
OVERALL DIMENSIONS
Dryer dimensions
Dryer with extended back:
30"
(762 mm)
43
1
/2"
(565 mm)
(783 mm)
NOTE: Most installations require a minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with elbow. See “Venting Requirements.”
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with
tested spacing of 0" (0 mm) clearance on sides and rear.
18"*
(457 mm)
Dryer with at back:
221/4"
14" max.*
(356 mm)
28"
(711 mm)
Louvered Hood Angled HoodBox Hood
The Vent system chart provides venting requirements
that will help achieve best drying performance.
NOTE: Bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length,
1"
(25 mm)
29"
(737 mm)
Recessed area Side view - closet or conned area
1"
(25 mm)
1"
(25 mm)
30"
(762 mm)
(Dryer with extended back)
5"
(127 mm)
add one 90° turn to the chart.
14" max.*
Vent system chart
Number of
90° elbows
0
1
2
3
4
Do not use vent runs longer than specied in vent
length chart.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
1"
(25 mm)
Side view - closet or conned area
(Dryer with at back)
* Required spacing
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
(356 mm)
28"
(711 mm)
5"
(127 mm)
48" 2*
(310 cm2)
2
24"
*
(155 cm2)
Closet door with vents
3"*
(76 mm)
3"*
(76 mm)
W10347751B
9/2011