Maytag MGDB800V User Manual

Gas Dryer
PRODUCT MODEL NUMBERS
MGDB800V
Gas supply: This dryer is equipped for use with Natural gas.
Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Recommended Styles:
Acceptable Style:
OVERALL DIMENSIONS
Dryer dimensions
Dryer with extended back:
30"
(762 mm)
43
1
/2"
(565 mm)
(783 mm)
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear.
18"*
(457 mm)
Dryer with at back:
221/4"
14" max.* (356 mm)
28"
(711 mm)
Louvered Hood Angled HoodBox Hood
The Vent system chart provides venting requirements that will help achieve best drying performance.
NOTE: Bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length,
1"
(25 mm)
29"
(737 mm)
Recessed area Side view - closet or conned area
1"
(25 mm)
1"
(25 mm)
30"
(762 mm)
(Dryer with extended back)
5"
(127 mm)
add one 90° turn to the chart.
14" max.*
Vent system chart
Number of 90° elbows
0
1
2
3
4
Do not use vent runs longer than specied in vent length chart.
Select the route that will provide the straightest and most direct path outdoors.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
1"
(25 mm)
Side view - closet or conned area
(Dryer with at back)
* Required spacing
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
(356 mm)
28"
(711 mm)
5"
(127 mm)
48" 2*
(310 cm2)
2
24"
*
(155 cm2)
Closet door with vents
3"*
(76 mm)
3"*
(76 mm)
W10347751B
9/2011