PRODUCT MODEL NUMBERS
MEDB765F MGDB765F
Electric and Gas Dryers
53"
(1341 mm)
(762 mm)
(685 mm)
30"
27"
401/2"
(1027 mm)
11/4"
(32 mm)
431/4"
(1096 mm)
30"
(762 mm)
Spacing for recessed area or closet installation
The dimensions shown are for the recommended spacing allowed.
■ Additional spacing should be considered for ease of installation
and servicing.
■ Additional clearances might be required for wall, door,
and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the
dryer is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings
are acceptable.
■ Companion appliance spacing should also be considered.
14" max
(356 mm)
3"/3"
18"/18"*
(457 mm)
(76 mm)
3"/3"
(76 mm)
2
/48"
48"
(310 cm2)
2/
24"
24"
(155 cm2)
2
2
A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 6" (152 mm) clearance
behind the dryer for the exhaust vent with elbow. See
“Venting Requirements.”
6"/0"
(152 mm/0 mm)
1"/0"
(25 mm/0 mm)
Recommended/Minimum spacing
1"/1"
(25 mm)
W10904260
01/2017
ELECTRICAL REQUIREMENTS VENTING REQUIREMENTS
■ To supply the required 3- or 4-wire, single phase, 120/240
volt, 60 Hz, AC only electrical supply (or 3- or 4-wire,
120/208 volt electrical supply, if specied on the serial/rating
plate) on a separate 30-amp circuit, fused on both sides of
the line. Connect to an individual branch circuit. Do not have
a fuse in the neutral or grounding circuit.
■ Do not use an extension cord.
■ 120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in
the Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of
90° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn
to the chart.