Maytag MGD9800TB, MGD9800TK, MGD9800TQ Dimension Guide

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
EXHAUST VENTING
MGD9800T
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10139630
10-15-07
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
A . Louvered hood style
B . Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
Recommended hood styles
Dryer only
Dryer on pedestal
Custom undercounter installation - Dryer only
Angled hood style is
acceptable.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
* Most installations require a minimum 5”
(12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See Installations Instructions, “Venting Requirements.”
®
Gas supply: Dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved aluminum or copper tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: 120 volt, 60 Hz, AC only, electrical supply is required on a separate 15- or 20-amp circuit, fused on both sides of the line. A time­delay fuse or circuit breaker and a separate circuit are recommended.
Exhaust venting: Exhaust your dryer to the outside. 4" (10.2 cm) heavy metal exhaust vent and clamps are required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.
EPIC z™Gas Dryer
A. Side view - closet or confined area B. Closet door with vents
*Required spacing.
**For side or bottom venting, 0" (0 cm)
spacing is allowed.
*Required spacing
A
B
A. Recessed area B. Side view - closet or confined area
*Required spacing.
**For side or bottom venting, 0" (0 cm)
spacing is allowed.
*Required spacing.
**For side or bottom venting, 0" (0 cm) spacing is allowed.
A
B
38"
(96.52 cm
)
*31½" (80 cm)
27"
(68.6 cm)
51½"
0"
(0 cm)
38" min. (96.52 cm)
1"* (2.5 cm)
27" (68.6 cm)
14" max.* (35.6 cm)
18" min.* (45.72 cm)
48 in.
(310 cm
3"*
2*
2
)
(7.6 cm)
1"* (2.5 cm)
14" max.* (35.6 cm)
18" min.* (45.72 cm)
4"
(10.2 cm)
2.
½"
(6.4 cm)
Number of 90° turns or elbows
NOTE:
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Type of vent
0Rigid metal
Flexible metal
1Rigid metal
Flexible metal
2Rigid metal
Flexible metal
3Rigid metal
Flexible metal
4Rigid metal
Flexible metal
Side and bottom exhaust installations have a 90° turn
Box or Louvered hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
2*
24 in.
(155 cm2)
1"*
(2.5 cm)
31½"
(80 cm)
5"**
(12.7 cm)
3"*
(7.6 cm)
1"
(2.5 cm)
27"
(68.6 cm)
7"* (17.8 cm)
7"* (17.8 cm)
5"**
(80.0 cm)
(12.7 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
31½"
(80 cm)
5"**
(12.7 cm)
9"* (22.9 cm)
1"*
31
"
(2.5 cm)
1" 1"
(68.6 cm)
(2.5 cm)
27"
(2.5 cm)
Loading...