SEALEDGASCOOKTOPS
Models:MGC5430& MGC5536 I,o
IMPORTANT: Dimensions Shown in Both Inches and Centimeters.
IMPORTANT: Be sure the appliance being installed is equipped for the gas to
underside of burner box for this information. Do not attempt to convert this appliance specified.
E
be supplied. Refer to serial plate on for use with a gas other than the type
inches cm
A 28 1/2 + 1/16 72.4 + 0.2
B 19 15/16 + 1/16 50.6 + 0.2 C 21/8 + 1/16 5.4 + 0.2
D 5 1/4 + 1/16 13.3 + 0.2 E 29 1/2 + 1/16 74.9 + 0.2
F 21 1/2 + 1/16 54.6 + 0.2 G 313/16 + 1/16 9.7 + 0.2
H 12 1/4 + 1/16 31.1 + 0.2
A 34 1/2 + 1/16 87.6 + 0.2
B 19 15/16 + 1/16 50.6 + 0.2 C 21/8 + 1/16 5.4 + 0.2
D 5 1/4 + 1/16 13.3 + 0.2 E 36 + 1/16 91.4 + 0.2 F 21 + 1/16 53.3 + 0.2
G 313/16 + 1/16 9.7 + 0.2 H 15 1/4 + 1/16 38.7 + 0.2
m
DIMENSIONS ..................
inches cm
CUTOUT DIMENSIONS
C
G H I-
ARE CRITICAL
SPECIAL WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE.
NOTICE TO INSTALLER: Leave these instructions with the appliance.
NOTICE TO CONSUMER: Retain these instructions for future reference.
8101 P582-60
(04-04-00)
Location Of Your Maytag Appliance
Locate this appliance away from combustible materials such as window curtains and combustible wall
decorations. Minimum horizontal clearance between the edge of the
appliance and combustible construction extending from the cooking surface to 18" (45.72 cm) above the cooking
surface is:
1.0" (2.54 cm) at rear 6" (15.24 cm) at sides
(Dimensions apply to both 30" and 36" wide models).
2.54 cm
FIGUREI
Installing Cabinetry
Over Your
Maytag Cooktop
A = 30" (76.2 cm) minimum
vertical clearance between cooking surface
and construction above the appliance. This
clearance may be reduced to not less than
24 inches (60.96 cm) by protecting the underside
of the combustible material or metal cabinet
above the cooking surface with not less than
1/4 inch (.635 cm)
insulating millboard covered with sheet metal
not less than 0.0122 inch thick.
B = 13" (33.02 cm) maximum depth of cabinets installed
above cooktop.
Avoid use of cabinets above cooktop for storage space to
eliminate associated potential hazards such as reaching over open flames.
A
f
U
2--B
FIGURE2
Preparation Of Countertop
The countertop cutout must be prepared according to the illustration on page 1 of these instructions.
CAUTION: Cutout dimensions are critical. Dimensions
must be measured and cut accurately to within + 1/16" (.159 cm) to ensure proper fit.
Important Preparation Suggestions
1. Chamfer all exposed edges of decorative laminate to prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking. Recommend
1/4" or 3/8" diameter drill in each corner.
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking of
the countertop laminate.
4. Countertop must be supported within 3" (7.62 cm) of cutout.
_ ERSONALINJURYANDMAY
ART # 9215-252
NOTE:THEFIGUREMAYNOTACCURATELYREPRESENT YOURRANGEORCOOKTOP;HOWEVER,THISWARNING
APPLIESTOALL GASCOOKINGPRODUCTS.
WARNING
THISPRODUCTSHOULDNOT BE INSTALLEDBELOWA
VENTILATIONTYPEHOOD SYSTEMTHATDIRECTSAIR
INA DOWNWARDDIRECTION.
(SEEFIGURE)
THESESYSTEMSMAYCAUSE
IGNITIONANDCOMBUSTION PROBLEMSWITHTHE GAS
BURNERSRESULTINGIN
AFFECTTHECOOKING
PERFORMANCEOFTHE UNIT.
Required Adjustments At Time Of Installation
The installation of this appliance must conform with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.t USA or current CAN/CGA-B149 INSTALLATION CODE.
[] This appliance was manufactured for use with Natural Gas. If LP gas is the fuel of choice, follow the conversion to
LP procedure found in the installation instructions. [] Test all external connections for gas leaks. Never test for gas leaks with an open flame. [] Test all electrical connections.
Checkthecooktopserialplatetoseeifthecooktopis approvedforinstallationinmobilehomesand/or
recreationalparktrailers.Serialplateislocatedonthe bottomoftheunit.
All supply piping, except as noted, should use common National Pipe Thread (N.P.T.). For all pipe connections
use an approved pipe joint compound resistant to the action of LP gas.
Ifapproved,thefollowingitemsareapplicable:
Mobile Homes
The installation of a range designed for mobile home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24 HUD, (Part 280)] or, when such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A, or with local codes.
In Canada the range must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical
Code Part 1 and Section Z240.4.1 - Installation Requirements for Gas Burning Appliances in Mobile
Homes (CSA Standard CAN/CSA - Z240MH).
Recreational Park Trailers
The installation of a range designed for recreational park trailers must conform with state or other codes or, in the
absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5-latest edition.
In Canada the range must be installed in accordance with CAN/CSA - Z240.6.2 - Electrical Requirements for R.V.'s
(CSA Standard CAN/CSA - Z240 RV Series) and Section Z240.4.2 - Installation Requirements for Propane
Appliances and Equipment in R.V.'s (CSA Standard CAN/CSA - Z240 RV Series).
Installation Of Appliance
The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition, or, in
Canada, CAN/CGA-B149 Installation Code, Latest Edition.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code ANSI/NFPA No. 70-Latest Edition, or, in Canada, current
CSA Standard C22.1 Canadian Electrical Code, Part 1.
In The Commonwealth Of Massachusetts
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of
Massachusetts.
A "T" handle type manual gas valve must be installed in the gas supply line to this appliance.
CAUTION: Warranty is void on Maytag equipment installed other than as recommended by manufacturer.
This appliance is designed for use with the appliance gas pressure regulator supplied with this appliance. It must be
installed in the gas line ahead of the gas manifold entrance. It is preset for use with natural gas and must be
converted, as described on pages 8 and 9, for use with LP gas. (See figures 7 - 12).
This appliance is designed to operate at a pressure of 5 inches of water column (36" models), 4 inches of water column (30" models) on natural gas or, if converted for
use with LP gas (propane or butane), 10 inches water column. Make sure this appliance is supplied with and
adjusted for the type of gas for which it is designed. This appliance was adjusted at the factory for use with
natural gas. If, at any time, this appliance is to be used with a different type of gas, all of the conversion
adjustments described on pages 8 and 9 must be made by a qualified service technician before attempting to
operate the cooktop on that gas. Natural gas should be supplied to the appliance pressure regulator at a line pressure between 6 and 14 inches of water column or, if
converted for LP gas, between 11 and 14 inches.
WARNING
If the line pressure supplying the appliance pressure regulator exceeds 14" water column (any gas), an
external regulator must be installed in the gas line ahead of the appliance regulator to reduce the pressure to no
more than 14" water column. Failure to do this can result in malfunction and damage to the appliance.
Insure this appliance is adjusted for the type of gas supplied to it and that the gas supply pressure to the
appliance regulator is within the proper pressure range.
If no other appliance is to be installed in the cabinetry below this unit, proceed as instructed under paragraph 1, page 4.
If this unit is to be installed over a Maytag Model MEW6500 or MEW5500 Series Electric Wall Oven
proceed as instructed under paragraph 2, page 5.
NOTE: In Canada, gas utilization codes prohibit use of street elbows. Use standard pipe elbows and make
modifications to these instructions as necessary.
A flexible gas connector, when used. must not exceed a
length of three (3) feet / 36 inches.
Connecting Appliance To Gas Supply
A QUALIFIED SERVICE TECHNICIAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS
SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer
according to the instructions given. Gas supply piping MUST conform to all local,
municipal and state building codes and local utility regulations.
1. IF NO OTHER APPLIANCE IS TO BE INSTALLED BELOW THIS COOKTOP
Join the appliance pressure regulator supplied with this
appliance to the entrance threads of the Gas Manifold.
The appliance regulator is marked with a directional
arrow indicating correct direction of gas flow. Ensure
the appliance regulator is installed with the arrow
pointing toward the gas manifold entrance. Tighten the appliance regulator to 20 to 30 ft-lbs of torque.
Never tighten to more than 35 ft-lbs of torque. Always use an approved pipe joint compound resistant to the
action of LP gas.
Apply a non-corrosive leak detection fluid to alljoints and fittings in the gas connection between the supply line
shut-off valve and the cooktop. Include gas fittings and
joints in the cooktop if connections were disturbed
during installation. Check for leaks! Bubbles appearing around fittings and connections will indicate a leak. If a
leak appears, turn off supply line gas shut-off valve,
tighten connections, turn on the supply line gas shut off valve, and retest for leaks. Never test for gas leaks with
an open flame.
ILLUSTRATIVE GAS SUPPLY PIPING
(NOOTHER APPLIANCEBELOWCOOKTOP)
BURNER BOX
(REAR OF APPLIANCE)
U MANIFOLD
"_'_ENTRANCE
I
(3/8"N.P.T.)
Install the appliance in its counter cutout. Make the gas connection to the inlet of the appliance
pressure regulator with 112" NPT male pipe threads. Install a manual shut-off valve in an accessible location in
the gas line ahead of the appliance pressure regulator and external to this appliance for the purpose of turning
on or shutting off gas to the appliance. Make additional pipe connections as necessary ahead of
the shut-off valve to the gas supply source. Assure all pipe joint connections are gas tight.
APPLIANCE_ PRESSURE
, REGULATOR
I
!
ALL SUPPLY SIDE
PIPE JOINTS
1/2" N.P.T.
3-
MANUAL
SHUTOFF
VALVE
-Ili 11111---[
ELBOW
FIGURE3
WARNING
Gas leaks may occur in your system and result in a dangerous situation. Gas leaks may not be detected by
smell alone. Gas suppliers recommend you purchase and
install an UL approved gas detector. Install and use in
accordance with the manufacturer's instructions.
TO GAS
INLET
2. IF THIS UNIT WILL HAVE A MAYTAG MODEL MEW6500 or MEW5500 SERIES ELECTRIC WALL OVEN INSTALLED BELOW THIS COOKTOP.
NOTE 1: This appliance and its gas and electrical supply
sources must be installed before the wall oven is installed. See illustration (Electrical Wiring Information - page 7;
figure 6) for recommended electrical supply source locations.
NOTE 2" It may be necessary to extend gas supply piping for this appliance into adjacent under-counter cabinetry
when a wall oven is installed below this appliance.
ILLUSTRATIVE GAS SUPPLY PIPING
(WALL OVEN INSTALLED BELOW 30" COOKTOP)
_,j. "_'--_ (REAR OF APPLIANCE)
i":'iiiiiiiii:_i___:iiiii.'.:iii::::_: ' ' MANIFOLD ,,
ii _i::: _=_/-_{--_ELBOW
Join a 3/8" NPT pipe elbow (locally available) to the male threads at the manifold entrance. When joined, ensure
open threads of the elbow face toward the right side of the appliance. Install the appliance in its counter cutout.
Join a 3/8" NPT pipe nipple to the elbow using a pipe section of sufficient length to extend, horizontally, beyond
the right side of the wall oven. (To accomplish this it may be necessary to extend the pipe section into adjacent
cabinetry.) Join additional 3/8" NPT elbow(s) and pipe nipples, as necessary, to accomplish the following:
Join the outlet of the appliance pressure regulator supplied with this appliance to the male threads of the
newly installed gas supply piping. Install the appliance regulator in a location which will be accessible beside or
below the wall oven. Insure the appliance regulator is installed with its directional arrow pointing in the direction
of gas flow. Tighten the appliance regulator to 20 to 30 ft-lbs of torque.
Never tighten to more than 35 ft-lbs of torque. Always use an approved pipe joint compound resistant to the
action of LP gas.
PIPING PASSES THROUGH DIVIDING
WALL BE-I'WEEN ADJACENT CAB NETS
_"f to suit)
APPLIANCE MANUAL
PRESSURE SHUTOFF
REGULATOR VALVE
L INLET
ALLUNITSIDE APPROXIMATECROSSSECTIONALLSUPPLYSIDE
PIPEJOINTS PROFILEOFWALLOVEN PIPEJOINTS
3/8"N.RT. 1/2"N.RT.
FIGURE4
Note, regarding Figure 4, above:
For convenience in service a union (not shown: locally available) should be included in the piping illustrated in figure 4, in a location most practical for the installation.
Generally, a practical location is in the cabinet below this appliance, near the manifold entrance, rather than
in an adjoining cabinet.
Locate and join a manual shut-off valve in an accessible location in the gas line ahead of the appliance regulator
and external to the appliance for the purpose of turning on or shutting off gas to the appliance.
Make additional pipe connections as necessary ahead of the shut-off valve to the gas supply source. Assure all
pipe joint connections are gas tight.
Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the supply line
shut-off valve and the cooktop. Include gas fittings and
joints in the cooktop if connections were disturbed during
installation. Check for leaks! Bubbles appearing around
fittings and connections will indicate a leak. If a leak
appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas shut off valve, and retest for leaks. Never test for gas leaks with an open
flame.
If the alternative piping method shown in figure 5 is selected for the installation, no union is required. (The flexible appliance connector illustrated provides the
union joints necessary for servicing.) When a dividing wall is present and a flexible connector is used it is
recommended for convenience, in both installation and service, the flexible connector, itself, pass through the
dividing wall. Any flexible connector used with this appliance must satisfy all requirements stated in
the text accompanying figure 5.
Alternative Piping Methods To Connect Appliance To Gas Supply
A TRAINED SERVICE TECHNICIAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS
SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer
according to the instructions given.
Unless prohibited by local codes or ordinances, a new A.G.A. - Certified, flexible metal appliance connector may be used to connect this appliance to its gas supply. The connector must be no more than 5 feet in length. Per figure 5, use appropriate flare union adapter at each end
of the flexible connector. If a flexible connector is used assure that both the appliance pressure regulator and
manual shut-off valve are joined solidly to other permanent hard piping (either gas supply or the appliance manifold) so as to be physically stationary. See
illustrations below.
Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the supply line
shut-off valve and the range. Include gas fittings and
joints in the range if connections were disturbed during
installation. Check for leaks! Bubbles appearing around
fittings and connections will indicate a leak. If a leak
appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas shut off valve,
and retest for leaks. Never test for gas leaks with an open
flame.
Pressure Testing
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pounds
per square inch (3.5 kPa). This appliance, as well as its individual shut-off valve,
must be disconnected from the gas supply piping system during any pressure testing of the system at test
pressures in excess of 1/2 pounds per square inch (3.5 kPa).
When checking appliance regulator function, make certain pressure of natural gas supply is between 6 and 14
inches of water column or, if converted for LP gas, between 11 and 14 inches of water column.
ILLUSTRATIVE ALTERNATIVE PIPING
Entrance
I I
_ "ql'--- Appliance Pressure /_
Regulator, Supplied ,,,,_ _"'_1111 J/ (Observe directionality .._li_,,,,_:_)
ofGasFlow) _ - -I, '_
u'_"-'_- Flare UnionAdaptor _ Adaptor
_[_ "_f!-_ _1.- 318"N.P.T.Flexible
1/2" N.P.T.Flexible _,_ _ ApplianceConnector
_ A5pfptiance.)Connector ._ (5ft. max.)
I
I
_" t 3/8"N,P,T, _ FlareUnion Elbow
I
1;_1- Flare Union Adaptor
I
1-Gas Shut-Off Valve
I
"91--1/2" N.P.T. Pipe
(Stationary Supply Pipe)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
FIGURE5
_1_ _1- FlareUnion
I
Regulator,Supplied
-,ql-- ppliance Pressure
(Observe
directionality of Gas
I Flow)
1_1/2" N.P.T. Pipe
Nipple
I
Gas Shut-Off Valve
I
-112" N.P.T.Pipe (StationarySupply
Pipe)
Adaptor
Electrical Wiring Information
This appliance is equipped with a grounded type power cord. A grounded outlet must be provided. It is
recommended, for convenience, the outlet be located (with reference to figure 6) as in A or B, below:
A. If no other appliance is to be installed below this
appliance: within either the shaded area or the cross hatched area shown in figure 6.
B. If a Model MEW6500 or MEW5500 Series Electric Wall
Oven is to be installed below this appliance, either:
1. within the cross hatched area of figure 6, or,
2. within an adjacent cabinet.
If a wall oven is to be installed below this appliance and the counter units outlet is to be mounted within the cross
hatched area of figure 6:
1. The cabinet's lower front panel, below the oven, must be made removable for access to the outlet.
2. A clearance hole for the power cord's plug (1-1/4" (3.18 cm) dia is recommended) must be provided through the
oven's floor support shelf and, if necessary, through the
slats supporting the shelf. The clearance hole should be located as near as practical to the rear of the shelf.
can be located as is convenient in this left wall or in the corresponding right wall.
In planning any installation, note that the free length of this appliance's power cord, extending beyond a point 3-3/4" (9.53 cm) left of the nominal center of the rear wall
of the burner box, when viewed from the front of the unit, is approximately 46" (117 cm).
User may experience occasional circuit tripping if Ground Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a (three-prong) grounding plug for your protection against shock
hazard and should be plugged directly into a properly grounded receptacle. Do not cut or
remove the grounding prong from this plug.
WARNING
If the outlet is to be mounted in either a left or right adjacent cabinet, a clearance hole, as described above, must be provided in the dividing wall between the
cabinets. Figure 4; page 5, illustrates a typical (left side) dividing wall. The clearance hole (not shown in figure 4)
_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii _i!i!iii!!!!!iiiii!_i_i_i_!!!!i_i_!!!!!i!!iii!ii!!iii!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!!!!_
Ii!!!!!!!!!i!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!iii!!!!i!iii!iiiiiiiiiiiii!!!i!i!!iiiiii
_i_iiiiiiiiiiiiiiiiiiiiiiiiiii!iii!!iiiiiiiiiiiiiiiii_iiiiiiiiiiiiiiiiiii_iiii_i_i_iiii_iiiiiiiiiiiiiii_
!iiiIii_!_!iii_iiiiiiiiii_iiiiii_i;iiii_iii_i_i;iiiiiiiiiiiiIiii_iii_iii_;!!_!_!_!_!_iii;_iii
E!!!!!!!!!!!!!_;_iiIiiiiiii;iii;;iiiii;i;!iiiiiii;iiiiiii_;i;i_;_;_;;_;_;;_;i;;i..
_!!!!iiiiiiiiiii_iiiiiiiiii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_iiii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!!!!!!_ _!!!!!i!!iiiiii_iiiiiiiiiiiiiii!!!ii!_!!!i!!i!iiiiiiiiii_iiii_i!_i!iii!!iii_iiii!iiiiiiiiii_i_!i!i_i!]!_!!!!_!!:.
i_i_iiiiiiiiiiiiiiiiiiiii!iiiiii!!_iiiiiiiiiiii!!_!!!i!!i!!!!!!i!!!!!!i!!!i!i!_iii!!!!!!!!!!!!!!!!!i!!ii_! i______iiiiiiiii!ii_!_!!!!!!!!!!!!!!!!!!!!!H!!_!!!!!_i_!!!!!!!i!!i!!!i!!!!iii_!_!!!!!!__iiiiiii_!iii_ii___i_iii:
!!!!!!i!!i___i__i_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii;iiiiiiiiiiiiiiiiiiiiiiiiiiii_iiiii;iii;iiiiiiiiiii___!!!!_!
!_ii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_ii_ii_i
!!!_!!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_ii_iiiiii;i_i_ii_;_;_i_ii_i_!_i_i_iii_iii_ii.
_!!!!!!!i!ii!iiiiii_i_iii_iii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_iii_iii_iiii_i_!!!!!!! _!!!!!!!!!i_!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_ii_!_!!!!_!_!!!_!!_!_
i.._iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!iiiiiiiiiii!!!i_ !iiiiiiii_:[Ii_ii_i_!_:___;_;i_ii;;iiiiii_iii
3 1/2" (8.89 cm) WIDE __ii
SLATS WHENA WALL
OVEN IS INSTALLED
BELOW30" MODEL CABINET BOTTOM
THIS APPLIANCE MUST BE DISCON-
NECTED FROM ITS ELECTRICAL SUPPLY AT THE WALL RECEPTACLE BEFORE SERVICING THE APPLIANCE.
3 13116"
9.7cm
29 318"
74.61 cm 37 3/16"
94.46 cm
i
4" MAX.
10.16 cm
FIGURE 6
Converting Appliance For Use With LP Gas
WARNING
Propane conversion is to be performed by a MAYTAG
AUTHORIZED SERVICER (or other qualified agency) in
accordance with the manufacturer's instructions and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency performing this work assumes responsibility for this
conversion.
WARNING
Electrical power and gas must be turned off prior to conversion.
This appliance was adjusted at the factory for use with natural gas. To convert it for use with LP gas (propane or
butane), each of the following modifications must be performed: (A, B, and C)
A. REPLACE ALL ORIFICE SPUDS
Step 1: Remove the grates and burner caps. Step 2: Remove burner base by removing 2 screws.
(See figure 7).
Step 3: Firmly press 9/32" (or 7ram) nut driver over the
orifice spud (figures 7 and 8) and loosen spud by turning counter- clockwise. Carefully lift nut
driver out of burner throat. Orifice spud should be captured in the nut driver. Repeat steps 2 &
3 for each burner.
REMOVAL OF ORIFICE SPUD
0.91_
Step 4:
Step 5:
Step 6:
Installation
Locate the LP orifice spud packet included in the literature packet. The spuds have small numbers stamped on the side. This number
codes the orifice diameter and its correct burner location. Figure 9 and 10 show the
correct LP orifice spud location. Carefully install the orifice spud in the
appropriate burner throat by turning clockwise to tighten. Tighten to a torque of 15 to 20
inch-lbs.
Replace burner base, caps, and grates. Tighten screws (do not cross thread) to 25-30
in Ibs.
Of
LP Orifice Spud
0.64
FIGURE9
0.91_
0.97
Burner
Cap,
Head
Orifice Holder
Locating
Ring
FIGURE7
Orifice-_ Holder 6 '"
Electrode
ART#9215-156-0
FIGURE8
Step 7:
0,64
Save the orifices removed from the appliance
for future use.
_] 0,91
@ @
©
_._ ARTI 921s-lgs-o
0.97
FIGURE10
B. INVERT CAP IN APPLIANCE PRESSURE
REGULATOR (See figure 11)
With the appliance installed, the appliance regulator
should be located as shown in figure 3, 4 or 5.
CONVERSION OF APPLIANCE
PRESSURE REGULATOR
CONVERTE APPLYSIDEWARD
R_r_Lp REPLACEPININCAP.
APPLYDOWNWARD
FINGERPRESSURE
ATDISCEDGESTO
_., CAP I _ FINGERPRESSURE
_"= AND PIN J TOREMOVEPIN
NAT i /'_ NAT I I LP
L+_ -- _
./" (_ FROMCAP
I I
FIGURE11
C. LOW FLAME ADJUSTMENT (See figure 12)
This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:
After adjusting the screw the burner should produce a stable, steady blue flame of minimum size. The setting
should be checked by turning knob from high to low several times without extinguishing the flame.
This operation will automatically provide the proper flame size at medium setting.
After Conversion Steps A, B and C have been completed, check the appearance of each burner flame at the Hi and
Lo settings against figure 13. If the flames appear too large or too small, review each step to make sure it was
completed correctly.
FLAME APPEARANCE AT HI AND LO
1. Remove control knob from valve stem.
2. Carefully remove rubber grommet.
3. Locate the valve adjustment screw. See figure 12.
4. Insert a slender, thin-blade screwdriver into knob hole and engage blade with slot in adjusting screw.
5. Turn the adjusting screw clockwise until tight (5-7 in-lbs max.). Do not over tighten.
6. Replace rubber grommet and control knob.
7. Repeat for remaining burners.
KNOB
ADJUSTI_
IIO0 OO0$
FIGURE13
, SCIEW I]
(KNOB AND GROMMET REMOVED)
FIGURE12
High Altitude Notice
The specified gas burner ratings typically apply to elevations up to 2000 feet. For higher altitudes, the rates may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a reduction is necessary.
To Convert Appliance For Use With Natural Gas
WARNING
4 BURNER MODEL (30" WIDE)
1,10I_ _ 1,55
Electrical power and gas must be turned off prior to conversion.
If this appliance has been converted for use with LP gas, each of the following modifications must be performed to
convert the unit back to natural gas.
A. REPLACE ALL ORIFICE SPUDS.
1. Perform Steps 1 and 2 on page 8.
2. Perform Step 3 on page 8.
3. For Step 4: Locate the brass natural gas orifice spuds that were originally installed in this appliance before its conversion for use with LP gas. Observe the number on each of the spuds and note the correct burner location for each spud as shown in figures 14 and 15.
Installation Of Natural Gas Orifice Spuds
5 BURNER MODEL (36" WIDE)
1.42
1.55_-_
1.07
© ©
© @
1,55 _]
1,85
FIGURE15
4. Complete Steps 5, 6 and 7 on page 8 to complete the installation of natural gas main spuds in their
correct locations.
5. Save the orifices removed from the appliance for future use. They will be needed if this appliance is again converted for use with LP gas.
B. INVERT CAP IN APPLIANCE PRESSURE
REGULATOR. (See figure 11).
With the appliance installed the appliance regulator
should be located as shown in either figure 3, 4 or 5 (pages 4, 5 & 6). Identify the type of appliance
regulator and follow the instructions in the appropriate illustration.
Z
_1.42 1.61
FIGURE14
C,
RESET THE VALVES FOR NATURAL GAS
1.
Light one burner, and set on low.
2.
Remove the knob.
3.
Remove the rubber grommets.
4.
Locate the valve adjustment screw. See figure 12.
5.
Insert a slender, thin-blade screwdriver into knob
hole and engage blade with slot in adjusting screw.
,
Starting from the LP position (see #5 on page 9, under C. LOW FLAME ADJUSTMENT), turn the screw counter clockwise until the flame stabilizes
and matches the pictured "low" setting on figure 13. Proper adjustment will produce a stable, steady blue flame of minimum size. The final adjustment should
be checked by turning the knob from high to low several times without extinguishing the flame.
After Steps A, B and C have been completed, check the appearance of each burner's flame at the Hi and Lo
settings against figure 13. If the flames appear too large or too small, make sure all steps were completed
correctly.
10
Burner Performance
CAUTION: Never cover control knobs or surrounding
control surface with utensils, towels, or other objects. Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is normal.
Specified input rates are as shown in figures 16 and 17 below.
5 BURNERMODEL(36"Wide)
o-.--
FIGURE16
°
MAYTAG36"
INPUT RATES- NATURALGAS / LP GAS (BTU/HR)
BURNERLOCATION Hi Lo
RightFront RightRear
LeftFront LeftRear Center
12,500/ 10,500
9,200 / 9,100 9,200 / 9,100
10,500/ 9,100
5,000 / 4,000
1300/ 1300 1300/ 1300 1300/ 1300 1300/ 1300
650/ 65O
4 BURNERMODEL(30"Wide)
*°*" "" *" *" -!
FIGURE17
ARTI921 S- _01 "0
MAYTAG30"
INPUT RATES- NATURALGAS/ LP GAS (BTU/HR)
BURNERLOCATION Hi Lo
RightFront RightRear
Left Front Left Rear Center
12,500 / 10,500
9,200 / 9,100 9,200 / 9,100
5OOO/ 4OOO
1300/ 1300 1300/ 1300 1300/ 1300
65O/ 65O
11