INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE
GAS INSTALLATION MANUAL
30" And 36" Built-in Cooktop
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE.
SPECIAL WARNING
ONLYQUALIFIED PERSONNELSHOULDINSTALL OR SERVICETHIS COOKTOR
READ "SAFETY INSTRUCTIONS"IN USE & CARE BOOK BEFORE USING COOKTOP.
IMPROPER INSTALLATION,ADJUSTMENT,ALTERATION,SERVICE, MAINTENANCE OR USE
OF COOKTOP CAN RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE.
IMPORTANT
Remove all packing material and literature from cooktop before connecting gas and electrical supply.
* NOTE: 30 inch dimension between cooking top and wall cabinet shown on illustration may be reduced to not less than
24 inches when the wall cabinets in a domestic home are protected with fireproof materials in accordance with American
National Standards - National Fuel Gas Code or in mobile homes when they are protected with fireproof materials in
accordance with the Federal Standard for Mobile Home Construction and Safety.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets.
A WIRING DIAGRAM IS ENCLOSED IN THE ENVELOPE WITH THIS BOOKLET; ALSO THERE IS A DIAGRAM GLUED
TO THE UNIT.
MODEL AND SERIAL NUMBER LOCATION
The serial plate for your cooktop is located on the extreme bottom of unit, visible from inside cabinet when installed. In addition
to the model and serial number, it tells you the ratings of the burners and type of fuel and pressure for which the cooktop was
adjusted when it left the factory.
CAUTION: SOME CABINETS AND BUILDING MATERIALS ARE NOT DESIGNED TO WITHSTAND THE HEAT
PRODUCED BY THE NORMAL SAFE OPERATION OF A LISTED APPLIANCE. DISCOLORATION OR DAMAGE, SUCH
AS DELAMINATION, MAY OCCUR.
YOUR COOKTOP MAY NOT BE EQUIPPED WITH SOME OF THE FEATURES REFERRED
TO IN THIS MANUAL.
8101 P121-60
(05-99-03)
INSTALLATION DRAWINGS
FOR SEALED BURNER MODELS
Clearances To Combustible Construction
These units can be installed in a cabinet made of wood or
other combustible material.
Maximum depth of cabinets installed above cooktop to be 13
inches.
*30" min. See NOTE on front page.
3 inches minimum to any combustible side wall.
30" AND 36" SEALED BURNER WITH PORCELAIN TOP
25" NORMAL
CABINET
TOP DEPTH. _-
IN
6 inches minimum spacing between individual top sections
in a dual installation.
DIM "C"
MIN
COMBUST I BLE
WALL
PROVIDE FOR 120 ELECTRI
GROUNDED) OUTLET IN CENTER
F CABINET BELOW COOKTOP
OVERALL WIDTH
OF UNIT A B C
30" 2" MIN. 1" MtN. 30" MIN.
36" 1 112" MIN. 1 112" MIN. 36" MIN.
DIM "B"
36"
HE I GHT OF
CAB I NET
"-4
-2-
30" SEALED BURNER WITH GLASS TOP
13 _ MAX.
COMBUSTIBL_
WALL
25" NORMAL
CABINET TOP DEPTH
f
3G _ HEIGHT
OF CABINET
MIN.
.,L
I
MIN. [
COMBUSTIBLE
WALL
IB a MIN,
jl _ _
PROVIDE FOR I_O VAC
ELECTRIC OUTLET \
(GROUNDED) IN _
CENTER OF CABINET
BELOW COOKTDP. OF CABINET \ \
36" SEALED BURNER WITH GLASS TOP
COMBUSTIBLE
WALL
25" NORMAL
CABINET TOP DEPTH
36" HEIGHT I" NIN.
OF CABINET
COMBUSTIBLE
WALL
IB" NIN,
PROVIDE FOR 120 VAC
ELECTRIC OUTLET
(GROUNDED) IN
CENTER OF CABINET
BELOW COOKTOP,
OF CABINET
-3-
Cutout Dimensions
30" SEALED BURNER WITH PORCELAIN TOP
NOTE= WHEN INSTALLED OVER A
30" WALL OVEN, ATTACH 90" ELBOW
TO SURFACE UNIT PIPING AND LOCATE
REGULATOR & SHUTOFF VALVE IN
ADJACENT (ACCESSIBLE) CABINET.
REGULATOR SUPPLIED WITH
UNIT AND SHUTOFF VALVE
MUST BE INSTALLED IN AN
ACCESSIBLE LOCATION.
3/8" DEPTH
REGULATOR INLET IS
FEMALE 1/2" NPT.
1 5/8" MIN.
*MINIMUM TO ANY
COMBUSTIBLE WALL
ABOVE COOKTOP.
FRONT OF UNIT
28 5/16"
3 7/8"
MIN,
36" SEALED BURNER WITH PORCELAIN TOP
*MINIMUM TO ANY COMBUSTIBLE
WALL ABOVE COOKTOP.
*2 1/8" MIN.--
193
35/16" DEPTH
REGULATOR SUPPLIED WITH
UNIT AND SHUTOFF VALVE
MUST BE INSTALLED IN AN
ACCESSIBLE LOCATION.
REGULATOR INLET IS
FEMALE 1/2" NPT.
34 7/8" MIN.
7/8"
-4-
36" SEALED BURNER WITH GLASS TOP
21 "
36"
I
i
• 2 5IS"
MIN.
* MINIMUM TO ANY
COMBUSTIBLE WALL
ABOVE COOKTOP
19
-_' MIN,
NOTE: ADD CLEARANCE INSIDE FOR
* 3 7/8" MIN.
GAS & ELECTRICAL CONNECTIONS.
30" SEALED BURNER WITH GLASS TOP
3 3/B"
DEPTH
21" 30" NOTE: WHEN INSTALLED OVER A
30" WALL OVEN, ATTACH 90" ELBOW
TO SURFACE UNIT PIPING AND LOCATE
WITH UNIT AND A SHUTOFF
VALVE MUST BE INSTALLED
IN AN ACCESSIBLE LOCATION.
NOTE: REGULATOR SUPPLIED
COOKTOP SUPPLIED WITH
1/2" NPT FEMALE
INLET ON REGULATOR.
2" TO _ OF PIPE
REGULATOR & SHUTOFF VALVE IN
ADJACENT (ACCESSIBLE) CABINET.
19
28 3/8"
* MINIMUM TO ANY
COMBUSTIBLE WALL
ABOVE COOKTOP
* 3 7/8" MIN.
-5-
NOTE: REGULATOR SUPPLIED
WITH UNIT AND A SHUTOFF
VALVE MUST BE INSTALLED
IN AN ACCESSIBLE LOCATION.
COOKTOP SUPPLIED WITH
1/2" NPT FEMALE
INLET ON REGULATOR,
2" TO _ OF PIPE
3 MIN.
NOTE: ADD CLEARANCE INSIDE FOR
GAS & ELECTRICAL CONNECTIONS.