14" WC max. LP gas- 11" WC min, 14" WC max.
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
30"
Maytag
• Product Model Number (s): •
Gas Cooktops:
3 3/8"
MGC5430ADQ, MGC5430ADB, MGC5430ADC and
MGC5430ADW
Side View (not to scale)
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from countertop to bottom of unit:
Cut-Out width:
Cut-Out depth:
30"
21"
3 3/8"
28 5/16"
19 13/16"
Minimum spacing to nearest vertical
combustible wall to the RIGHT:
3 7/8"
Minimum spacing to nearest vertical
combustible wall to the LEFT:
3 7/8"
Minimum spacing to nearest vertical
combustible wall to the REAR:
Minimum spacing to front edge of counter:
1 5/8"
2 5/8"
1 5/8"
19 13/16"
28 5/16"
2 5/8"
3 7/8" 3 7/8"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
(not to scale)
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
Maximum depth of cabinets directly
above and adjacent:
30" min
30"
13"
Cabinet Requirements
Wall View
(not to scale)
30"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Designed to fit in a standard 30" wide cabinet and 25"
deep countertop.
• Minimum spacing between two individual built-in
surface units is 6".
30" min
18"
Requires 18" high by
3 3/8" wide clearance to
any combustible
surface above the
cooktop on both sides.
(noted by solid area)
• Minimum distance from top of counter to combustible
material below is 4 1/8".
• Electrical requirements: 120 volts 60 Hz protected by
a 15 amp fuse or compatible circuit breaker. Minimum
wire size is 14 gauge. Copper wire only. Unit is
supplied with a 13" long power cord having a 3-prong
grounding pug which exits from the cooktop in the
middle of the right. A grounded and polarized 3-prong
receptacle should be made available. Individual branch
circuit serving the cooktop is recommended.
• Gas requirements: Supply line should be 3/4" and
enter the cooktop in right rear corner of unit. Unit is
2 1/32' to centerline of pipe from
back edge of cutout
Gas inlet location
shipped from factory for use on natural gas. Unit is
equipped with built-in conversion for use on LP gas.
- Supplied with 1/2" NPT female inlet on regulator.
Regulator supplied with unit and a shutoff valve must
be installed in an accessible location.
- Gas pressure requirements: Natural gas- 5" WC min,
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
252
Top view of cutout
(not to scale)
Cooktop supplied with 1/2" NPT female inlet on regulator
1 17/32" to
centerline of pipe
from left edge of
cutout
BN • A252 • • 032603 • 95656 • 64089
21"