INSTALLATION
INSTRUCTIONS
Built-In 27²²²² &30²
²
²²
Electric Wall Ovens
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
27²²²² SINGLE WALL OVEN
111/4² Dia. Conduit Access Hole* 25/8² Plywood Floor (Must Support142 lbs.)
DIMENSIONS
inches cm
A 27 MIN 68.58 B 24 MIN 60.96 C277/8+ D 24.0 60.96 E251/2+ F 28 1/4 71.76 G 26 3/4 67.95 H 24 7/16 62.07 I 4 to 33 10.2 to 83.8
1/16 70.80
1/16 64.77
27²²²² DOUBLE WALL OVEN
111/4² Dia. Conduit Access Hole* 25/8² Plywood Floor (Must Support250 lbs.)
DIMENSIONS
inches cm
A 27 MIN 68.58 B 24 MIN 60.96 C 50.0 + D 24.0 60.96 E251/2+ F 50 1/14 127.64 G 26 3/4 67.95 H 24 7/16 62.07 I 4 to 12 10.2 to 30.5
1/16 127.0
1/16 64.77
30²²²² SINGLE WALL OVEN
111/4² Dia. Conduit Access Hole* 25/8² Plywood Floor (Must Support142 lbs.)
DIMENSIONS
inches cm
A 30 MIN 76.20 B 24 MIN 60.96 C277/8+ D 24.0 60.96 E281/2+ F 28 1/4 71.76 G 29 3/4 75.57 H 24 7/16 62.07 I 4 to 33 10.2 to 83.8
1/16 70.80
1/16 72.39
30²²²² DOUBLE WALL OVEN
111/4² Dia. Conduit Access Hole* 25/8² Plywood Floor (Must Support250 lbs.)
DIMENSIONS
inches cm
A 30 MIN 76.20 B 24 MIN 60.96 C 50.0 + D 24.0 60.96 E281/2+ F 50 1/4 127.64 G 29 3/4 75.57 H 24 7/16 62.07 I 4 to 12 10.2 to 30.5
1/16 127.0
1/16 72.39
SINGLE WALL OVEN
DOUBLE WALL OVEN
30²²²² WALL OVEN UNDER COUNTER
111/4² Dia. Conduit Access Hole* 25/8² Plywood Floor (Must Support 142 lbs.)
A 25 63.50 B 24 MIN 60.96 C277/8+ D 24.0 60.96 E 28 1/2 72.39 F 28 1/4 71.76 G 29 3/4 75.57 H 24 7/16 62.07 I 36 91.44 J11/2 3.81
30²²²² WALL OVEN
* * COOKTOPS inches cm
K Electric 3 1/8 MIN 7.9 MIN K Induction 3 1/8 MIN 7.9 MIN K 4 Burner Gas Stamped Top 4 13/16 MIN 12.2 MIN K 4 Burner Gas Glass Top 4 13/16 MIN 12.2 MIN
NOTE:
* Hole must be cut as close to corner of cabinet as possible.
** See dealer for approved cooktops.
DIMENSIONS
inches cm
1/16 70.80
UNDER COUNTER WALL OVEN
NOTES
Z Do not block air intake slots along bottom of oven. Y Gas or electriccooktops may be installed overovens.
See cooktop installation instructionsfor cutout size.
W Electrical connection forelectric cooktopmust be in adjacent
accessiblelocation.Cooktop and wall oven must be on separate 120/240 or 120/208 volt 60 Hz AC circuits.
(09-03-00)
CAUTION
For European style cabinets (flush front) the required clearance for operation of the oven door is minimum spacing of 7/8² between the cutout and the door, hinge or drawer of the cabinet.
Electrical Connections
Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
Some built-in cabinets may not be wide enough, due to their construction, to allow this installation.
1. Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight.
NOTE: There are no provisions to level the unit after it is installed. An oven that is not level could cause poor baking results.
2. Install plywood floor as shown.
3. Attach unit to the cabinet with four No. 8 x 1² screws supplied with unit inside of envelope containing these instructions. Pre-drill holes in cabinet for attachment screws using 1/8² drill. Oven mounting holes are provided in side trim.
4. See instructions at right for electrical hook-up.
5. See Use and Care Manual for operating instructions.
Installing Bottom Trim Piece
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on front of unit for power requirements.
The neutral of this unit is grounded to the frame through the green or solid grounding wire. (The green and the white wires are twisted together at the termination of the conduit.) If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the green wire and connect the green wire to ground in accordance with local code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit.
K.W.RATING
ON SERIAL PLATE
0-- 4.8
4.9 -- 6.9
7.0 -- 9.9
10.0 -- 11.9
12.0 -- 14.9
RECOMMENDED MINIMUM
CIRCUIT PROTECTION
IN AMPERS
20 30 40 50 60
WIRE SIZE
(AWG)
12 10
8 8 6
Service
Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this could result in a dangerous or even fatal shock.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE