29" Electric Dryer Installation Instructions
4"
(102 mm)
4"
(102 mm)
B
A
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356 mm)
27¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
PRODUCT MODEL NUMBERS
MEDC200X, MEDC300X
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended. Connect to
an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
(Steam models only): The dryer must be
Water
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting
4" (102 mm) diameter vent is required. Rigid or exible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
: Exhaust your dryer to the outside.
C
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
OVERALL DIMENSIONS
Dryer dimensions
A. Large opening side-swing door
B. Large opening side-swing door
Minimum Required Spacing
C. Wide opening side-swing door
D. Wide opening hamper door
The Vent system chart provides venting requirements
that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90°
turn inside the dryer. To determine maximum exhaust
length, add a 90° turn to the total number of elbows
when referemcing the chart.
Vent system chart
Number of
90° elbows
0
1
2
3
4
Do not use vent runs longer than specied in vent
length chart.
Determine the number of elbows you will need.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Type
Box/louvered
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
hoods
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
A. Recessed area
B. Side view - closet or conned area
C. Closet door with vents
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”