Planication des circuits de conduits .............................. 34
Installation du système d’évacuation ............................... 35
RACCORDEMENT DES TUYAUX D’ALIMENTATION .............. 36
RACCORDEMENT DU SYSTÈME D’ÉVACUATION ................. 37
ÉTABLIR L’APLOMB DE LA SÉCHEUSE ..................................38
ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION .......... 38
INVERSION DU SENS D’OUVERTURE DE LA PORTE ............ 40
RÉINSTALLER CHARNIÉRES SUR LA PORTE ........................ 42
INVERSION DE LA GÂCHE .......................................................42
............................................27
Para obtener acceso al “Instrucciones de instalación” en español, o para obtener información
adicional acerca de su producto, visite: www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo
y de serie dentro de la cavidad superior de la puerta.
INSTALLATION NOTES
Date of purchase: _________________________________
Date of installation: _______________________________
Installer: ________________________________________
Model number: ___________________________________
Serial number: ___________________________________
NOTES CONCERNANT L’INSTALLATION
Date d’achat : _____________________________________
Date d’installation : ________________________________
Installateur : ______________________________________
Numéro de modèle : ________________________________
Numéro de série : __________________________________
W11101372A
W11101373A-SP
DRYER SAFETY
2
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
–
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this
or any other appliance.
–
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Clear the room, building, or area of all occupants.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
•
instructions.
If you cannot reach your gas supplier, call the re department.
•
–
Installation and service must be performed by a qualied installer, service agency, or
the gas supplier.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by
the State of Massachusetts.
■ Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.
■ A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).
3
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed for all installations:
Flat-blade screwdriver
Level
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Vent clamps
Tools needed for gas installations:
8" (203 mm) or 10"
(254 mm) pipe wrench
Pipe-joint compound
resistant to propane gas
8" (203 mm) or 10"
(254 mm) adjustable wrench
(for gas connections)
Parts supplied (all models):
Plastic putty knife
Tin snips (new vent
installations)
#2 Phillips screwdriver
Tape measure
4
Caulking gun and
compound (for installing
new exhaust vent)
1/4" (6 mm) nut driver
(recommended)
Wire stripper (direct wire
installations)
Pliers
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed (steam models):
“Y” connector
inlet hose
Short inlet hose
Rubber washer (4)
If using a power supply cord:
Use a UL-listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
■ A UL-listed 30-amp power supply cord, rated 120/240 volt
minimum, with a temperature rating of 140°F (60°C) minimum.
The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to
the dryer must end in ring terminals or spade terminals
with upturned ends.
■ EA UL-listed strain relief.
Parts needed:
(Not supplied with dryer)
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the “Assistance
or Service” section in your Use and Care Guide.
Enhance your new washer and dryer with genuine Whirlpool
accessories. For more information on options and ordering,
call 1-866-698-2538, or visit us at: www.whirlpool.com/
accessories. In Canada, call 1-800-688-2002 or visit us at
www.whirlpoolparts.ca.
LOCATION REQUIREMENTS
INSTALLATION CLEARANCES
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
DRYER DIMENSIONS
Front Controls Models
5
57
/8"
(1464 mm)
331/2"
(851 mm)
Door Opened
Door Closed
29"
(737 mm)
You will need:
■ A location allowing for proper exhaust installation.
See “Venting Requirements.”
■ A separate 15- or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers
■ If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
■ Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
■ Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), clothes may not
tumble properly and automatic sensor cycles may not operate
correctly.
■ For garage installation, place dryer at least 18" (460 mm)
above oor.
■ Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water ll valves, and water pressure of 20–100
psi (137.9–689.6 kPa). You may use your washer's water
supply by purchasing the necessary parts noted in “Parts
needed.”
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45°F (7°C). Lower temperatures may cause dryer not to shut
off at end of automatic sensor cycles, resulting in longer drying
times.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
413/8"
1"
(25 mm)
Side view
3
11
/8"
(289 mm)
(1050 mm)
5
3
/8"
(93 mm)
3"
(77 mm)
13/8"
(35 mm)
Back view
1
/2"
14
(370 mm)
(150 mm)
(115 mm)
Bottom view:
81/2"
(218 mm)
3
/8"
14
(365 mm)
Rear Controls Models
5
1"
(25 mm)
57
/8"
(1464 mm)
331/2"
(851 mm)
3
11
/8"
(289 mm)
Door Opened
Door Closed
4111/16"
43 716"
(1103 mm)
(1103 mm)
5
3
/8"
(93 mm)
3"
(77 mm)
(737 mm)
13/8"
(35 mm)
29"
(370 mm)
(150 mm)
(115 mm)
1
/2"
14
Back viewSide view
Bottom view:
81/2"
(218 mm)
3
14
/8"
(365 mm)
NOTE: Most installations require a minimum of 6" (152 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”
57/8"
1
4
/2"
3
(93 mm)
57/8"
1
4
/2"
3
(93 mm)
1
/2"
1
/2"
5
Spacing for recessed area or closet installation
The dimensions shown are for the recommended spacing
allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door,
and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the
dryer is recommended to reduce noise transfer.
■ For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
■ Companion appliance spacing should also be considered.
14" max
(356 mm)
3"/3"
6"/0"
(152 mm/0 mm)
1"/0"
(25 mm/0 mm)
18"/18"*
(457 mm)
(25 mm)
1"/1"
(76 mm)
3"/3"
(76 mm)
2
48 in./48 in.
/48"
48"
(310 cm2)
2/
24 in./24 in.
24"
24"
(155 cm2)
Recommended/Minimum spacing
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
■ Metal exhaust system hardware, available for purchase
from your dealer. For further information, see “Assistance
or Service” section in your Use and Care Guide.
■ Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as
dryer exhaust opening.
For gas dryer mobile home installations:
■ Mobile Home Installation Hold-down Kit is available to order.
For further information, see “Assistance or Service” section in
your Use and Care Guide.
ELECTRICAL REQUIREMENTS –
U.S.A. ONLY (SPÉCIFICATIONS
ÉLECTRIQUES – ÉTATS-UNIS
SEULEMENT)
It is your responsibility:
■ To contact a qualied electrical installer.
■ To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70 – latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
■ To supply the required 3- or 4-wire, single-phase,
120/240-volt, 60-Hz, AC-only electrical supply
(or 3- or 4-wire, 120/208-volt electrical supply, if specied on
2
2
the serial/rating plate) on a separate 30-amp circuit, fused on
both sides of the line. Connect to an individual branch circuit.
Do not have a fuse in the neutral or grounding circuit.
■ Do not use an extension cord.
■ If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■ This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor
is permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground conductor must be
removed from the external ground connector (green screw),
and secured under the neutral terminal (center or white wire)
of the terminal block. When the neutral ground conductor is
secured under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
■ If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see “Optional 3-wire
connection” section.
■ A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
Use a UL-listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
■ A UL-listed 30-amp power supply cord, rated
120/240-volt minimum, with a temperature rating
of 140°F (60°C) minimum. The cord should be type SRD
or SRDT, and be at least 4 ft. (1.22 m) long. The wires that
connect to the dryer must end in ring terminals or spade
terminals with upturned ends.
■ A UL-listed strain relief.
6
If your outlet looks like this:
Then choose a 4-wire power supply cord with
ring or spade terminals and UL-listed strain
relief. The 4-wire power supply cord, at least
4 ft. (1.22 m) long, must have four 10-gauge
solid copper wires and match a 4-wire
4-wire
receptacle
(14-30R)
receptacle of NEMA-Type 14-30 R. The ground
wire (ground conductor) may be either green or
bare. The neutral conductor must be identied
by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord
with ring or spade terminals and UL-listed
strain relief. The 3-wire power supply cord,
at least 4 ft. (1.22 m) long, must have three
10-gauge solid copper wires and match a
3-wire
receptacle
(10-30R)
3-wire receptacle of NEMA-Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
■ Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with exible metallic conduit. All
current-carrying wires must be insulated.
■ 10-gauge solid copper wire (do not use aluminum) at
least 5 ft. (1.52 m) long.
ELECTRIC DRYER POWER HOOKUP –
CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
■ To contact a qualied electrical installer.
■ To be sure that the electrical connection is adequate and
in conformance with Canadian Electrical Code, C22.1 – latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
■ To supply the required 4-wire, single-phase, 120/240-volt,
60-Hz, AC-only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
■ This dryer is equipped with a UL listed
and/or CSA International Certied Power
Cord intended to be plugged into a standard
14-30R wall receptacle. The cord is
5 ft. (1.52 m) long. Be sure wall receptacle
is within reach of dryer’s nal location.
For further information, please reference service numbers located
in “Assistance or Service” section of your Use and Care Guide.
4-wire receptacle
(14-30R)
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
7
GAS DRYER POWER HOOKUP –
U.S.A. AND CANADA
ELECTRICAL REQUIREMENTS
■ 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is certied by
UL for use with propane gas with appropriate conversion.
■ Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced in the “Assistance or Service”
section of your Use and Care Guide.
Propane Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician.
No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a
different gas without consulting your gas company.
GAS SUPPLY LINE
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
■ If local codes permit, use a new exible stainless steel gas
connector (Design Certied by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" (9.5 mm) are x 3/8"
(9.5 mm) NPT adapter tting between the stainless steel
gas connector and the dryer gas pipe as needed to prevent
kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
■ Must include 1/8" (3 mm) NPT minimum plugged tapping
accessible for test gauge connection, immediately upstream
of the gas connection to the dryer.
■ 1/2" (12.7 mm) IPS pipe is recommended.
■ 3/8" (9.5 mm) approved aluminum or copper tubing is
acceptable for lengths under 20 ft. (6.1 m) if local codes and
gas supplier permit.
■ If you are using Natural gas, do not use copper tubing.