Maytag MEC5536BAB, MEC5536BAS, MEC5536BAW Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Electric Cooktops:
MEC5536BAB, MEC5536BAS and MEC5536BAW
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from countertop to bottom of unit:
Cut-Out width:
Cut-Out depth:
35 5/16" 21" 3 3/4" 34 9/16" 20 3/8"
Minimum spacing to nearest vertical
combustible wall to the RIGHT:
0"
Minimum spacing to nearest vertical
combustible wall to the LEFT:
0"
Minimum spacing to nearest vertical
combustible wall to the REAR:
Minimum spacing to front edge of counter:
0" 2 1/8"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" 36"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
n/a
• Additional Information •
• Designed to fit in a standard 30" wide cabinet and 25"
deep countertop.
• Minimum distance from top of counter to combustible
material below is 4 1/8".
• Electrical requirements: 120/240 volts 60 Hz
protected by a 40 amp grounded fuse or compatible circuit breaker. Minimum wire size is 8 gauge. Copper wire only. Unit is supplied with a 48" long cable. Locate junction box in accessible location in opening below cooktop (4 1/8" minimum below countertop). Individual branch circuit serving the cooktop is recommended.
Side View (not to scale)
0"
2 1/8"
3 3/4"
20 3/8"
34 9/16"
0" 0"
36"
30"
n/a
C
L
35 5/16"
21"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
Cabinet Requirements
Wall View
(not to scale)
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
166
BN • A166 • • 032603 • 9570 • 28603
Loading...