Maytag MDG76PC User Manual

MDG76PC
Installation Manual
Phase 7.3 Coin Gas DSI
W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
— Do not store or use gasoline or other flammable
— WHA T TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
— QUE F AIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur . Ne pas vous servir des téléphones se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
— L ’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
RET AIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 113184
Retain This Manual In A Safe Place For Future Reference
Our products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation.
ONLY qualified technicians should service this equipment.
OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.
The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
We have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
Important
For your convenience, log the following information:
DA TE OF PURCHASE________________________________________________ MODEL NO. __________________________
DEALER’S NAME __________________________________________________________________________________________
Serial Number(s) ________________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
For replacement parts, contact the dealer from which the dryer was purchased or contact:
MAYTAG CO.
403 West Fourth Street North
Newton, Iowa 50208
(641) 787-7000
“IMPORT ANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer.
IMPORTANT
YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING, INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health
Administration) STANDARDS.
«Attention: Au moment de l’entretien des “Caution: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper operation.”
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de câblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.»
CAUTION
DR YERS SHOULD NEVER BE LEFT UNA TTENDED WHILE IN OPERA TION.
WARNING
CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR THE DRYER(S). CHILDREN
SHOULD BE SUPER VISED IF NEAR DRYERS IN OPERA TION.
FOR YOUR SAFETY
DO NOT DR Y MOP HEADS IN THE DRYER. DO NOT USE DR YER IN THE PRESENCE OF DR Y CLEANING FUMES.
WARNING
UNDER NO CIRCUMSTANCES should the dryer door switches, lint drawer switch, or the heat circuit devices ever be disabled.
WARNING
The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T .
WARNING
DRYER MUST NEVER BE OPERA TED WITHOUT THE LINT FIL TER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.
IMPORTANT
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
Dryer must not be installed or stored in an area where it
The wiring diagram for the dryer is located in the front electrical control box area.
will be exposed to water or weather.
IMPORTANT
Dryer must be installed in a location/environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
Table of Contents
SECTION I
SAFETY PRECAUTIONS ......................................................................................... 2
SECTION II
SPECIFICATIONS/COMPONENT IDENTIFICATION.....................................4
A. Specifications ............................................................................................................................. 4
B. Component Identification ............................................................................................................ 6
SECTION III
INSTALLATION PROCEDURES ........................................................................... 8
A. Location Requirements ............................................................................................................... 8
B. Unpacking/Setting Up ................................................................................................................. 9
C. Dryer Enclosure Requirements .................................................................................................. 11
D. Fresh Air Supply Requirements ................................................................................................. 12
E. Exhaust Requirements ............................................................................................................... 13
F. Electrical Information ................................................................................................................ 17
G . Gas Information ........................................................................................................................ 20
H. Preparation for Operation/Start-Up........................................................................................... 23
I. Preoperational T est ................................................................................................................... 24
J. Preoperational Instructions ........................................................................................................ 26
K. Shutdown Instructions............................................................................................................... 26
SECTION IV
ROUTINE MAINTENANCE .................................................................................. 2 7
A. Cleaning ................................................................................................................................... 27
B. Adjustments ............................................................................................................................. 28
C. Lubrication ............................................................................................................................... 28
SECTION V
DATA LABEL INFORMATION .............................................................................29
SECTION VI PROCEDURE FOR FUNCTIONAL CHECK
OF REPLACEMENT COMPONENTS ................................................................ 30
SECTION I
SAFETY PRECAUTIONS
WARNING: For your safety , the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury , or loss of life.
WARNING: The dryer must never be operated with any of the back guards, outer tops, or
service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T .
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the
user smells gas. The instructions should be posted in a prominent location.
3. WHAT TO DO IF YOU SMELL GAS:
a. DO NOT try to light any appliance.
b. DO NOT touch any electrical switch.
c. DO NOT use any phone in your building.
d. Clear the room, building, or area of ALL occupants.
e. Immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions.
f. If you cannot reach your gas supplier, call the fire department.
4. Installation and service must be performed by a qualified installer, service agency , or gas supplier.
5. Dryer(s) must be exhausted to the outdoors.
6. Although Maytag produces a very versatile dryer , there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry cleaning
solvents, a combustible detergent, or “all purpose” cleaner . EXPLOSION COULD
RESULT.
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint,
or wax. EXPLOSION COULD RESUL T .
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a
fire hazard.
2 Maytag Co. 113184-7
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or
similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork,
and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to electrically ground the dryer properly will VOID THE WARRANTY.
9. UNDER NO CIRCUMSTANCES should the dryer door switches, lint drawer switch, or the heat circuit
devices ever be disabled.
W ARNING: PERSONAL INJUR Y OR FIRE COULD RESUL T SHOULD THE DR YER
DOOR SWITCHES, LINT DRAWER SWITCH, OR THE HEA T CIRCUIT DEVICES EVER BE DISABLED.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
13. For safety, proper operation, and optimum performance, the dryer must not be operated with a load less
than sixty-six percent (66%), 50 lb (22 kg) of its rated capacity.
W ARNING: YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPL Y
AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.
IMPORTANT: Dryer must be installed in a location/environment, which the ambient
temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
113184-7 Maytag Co. 3
SPECIFICATIONS/COMPONENT IDENTIFICATION
A. SPECIFICAITONS
SECTION II
MAXIMUM CA PA CITY (DRY WEIGHT) 7 5 lb TUMBLER DIAMETER 44-1/2” TUMBLER DEPTH 24-7/8” TUMBLER VOLUME 22.40 cu ft TUMBLER/DRIVE MOTOR 1 hp* BLOWER/FAN MOTOR N / A DOOR OPENING (DIAMETER) 31-3/8” DOO R SILL HE IGHT 31” WATER CONNE CTION N / A DRYERS PER 20’/40 ’ C ONTAINER 10 / 20 DRYE RS PE R 48’/53’ TRUCK 25 / 27
VOLTAGE AVAILABLE 120-575V 1,3ø 2,3,4w 50/60 Hz APPROXIMATE NET WEIGHT 888 lb APPROXIMATE SHIPPING WEIGHT 938 lb
kcal/hr
60 Hz 50 Hz
1,200 cfm 1,000 cfm
N / A
N / A
AIRFLOW
HEAT INPUT 204,000 Btu/hr
Gas
EXHAUST CONN ECTION (DIA ME TER) 10” COMPRESSED AIR CONNECTION N / A COMPRESSED AIR VOLUME N / A INLET PIPE CON N EC T ION 3/4” F.N.P .T. VOLTAGE AVAILABLE APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW EXHAUST CONN ECTION (DIA ME TER) COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME
ElectricSteam
kW Btu/hr VOLTAGE AVAILABLE APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW STEAM CONSUMPTION OPERATING STEAM PRESSURE EXHAUST CONN ECTION (DIA ME TER) COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME BOILER HORSEPOWER (NORMAL LOAD) SUPPLY CONNECTION RETURN CONNECTION
Shaded areas are stated in metric equivalents 5/4/05 * For single-phase (1ø) dryers use 1 motor: 1 hp drive/fan. For 3-phase (3ø) non-reversing dryers use 1 motor:
1 hp drive/fan and for 3-phase (3ø) reversing dryers use 2 motors: 1 hp fan and 1/2 hp drive.
OVEN SIZE
34.02 kg
113.03 cm
63.18 cm
634.30 L
0.75 kW
79.69 cm
78.74 cm
402.79 kg
425.47 kg
33.98 cmm
28.32 cmm
51,407 kcal/hr
25.40 cm
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
4 Maytag Co. 113184-7
Specifications – Gas
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
113184-7 Maytag Co. 5
B. COMPONENT IDENTIFICATION
1. Dryer Front View
Illus. No. Description
1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Data Label and Installation Label
6 Maytag Co. 113184-7
2. Dryer Rear View
Illus. No. Description
1 Heating Unit 2* Electric Service Relay Box 3 Basket (tumbler) Bearing Mount Assembly 4 Idler Bearing Mount Assembly 5 Basket (tumbler) (drive) Motor Assembly (for reversing models ONLY) 6 Blower Motor Assembly 7 Dryer Exhaust
* Electric service connections for gas models are made in this box.
113184-7 Maytag Co. 7
Loading...