Gas and Electric Dryer
PRODUCT MODEL NUMBERS
MEDB955F, MGDB955F
INSTALLATION CLEARANCES
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
DRYER DIMENSIONS
Front Controls Models
Bottom view:
1"
(25 mm)
5
57
/8"
(1464 mm)
Side view
331/2"
(851 mm)
3
11
/8"
(289 mm)
Door Opened
Door Closed
413/8"
(1050 mm)
5
3
/8"
(93 mm)
3"
(77 mm)
29"
(737 mm)
13/8"
14
(370 mm)
(35 mm)
Back view
1
/2"
57/8"
(150 mm)
1
4
/2"
(115 mm)
3
(93 mm)
1
/2"
Rear Controls Models
5
57
1"
(25 mm)
/8"
(1464 mm)
331/2"
(851 mm)
3
11
/8"
(289 mm)
Door Opened
Door Closed
4111/16"
43 716"
(1103 mm)
(1103 mm)
5
3
/8"
(93 mm)
3"
(77 mm)
(737 mm)
13/8"
(35 mm)
1
/2"
14
(370 mm)
(150 mm)
(115 mm)
Back viewSide view
Bottom view:
81/2"
(218 mm)
3
14
/8"
(365 mm)
NOTE: Most installations require a minimum of 6" (152 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”
57/8"
1
4
/2"
3
(93 mm)
1
/2"
81/2"
(218 mm)
3
14
/8"
(365 mm)
Spacing for recessed area or closet installation
The dimensions shown are for the recommended spacing
allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
■ Companion appliance spacing should also be considered.
Minimum Required Spacing
Companion appliance spacing should also be considered.
14" max
(356 mm)
3"/3"
18"/18"*
(457 mm)
6"/0"
(152 mm/0 mm)
1"/0"
(25 mm/0 mm)
Recommended/Minimum spacing
1"/1"
(25 mm)
(76 mm)
(76 mm)
3"/3"
48 in./48 in.
48"
(310 cm2)
24 in./24 in.
24"
(155 cm2)
W10884084A
2
/48"
2/
24"
05/2016
2
2
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS - Gas models only
■ 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It
is also recommended that a separate circuit serving only this dryer be provided.
ELECTRICAL REQUIREMENTS - Electric models only
■
To supply the required 3- or 4-wire, single-phase,
120/240-volt, 60-Hz, AC-only electrical supply
(or 3- or 4-wire, 120/208-volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both
sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
■ Do not use an extension cord.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter
vent is required. Rigid or exible metal exhaust vent must be used. Do not
use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm)
from the ground or any object that
may be in the path of the exhaust.
WARNING: To reduce the risk of re, this dryer MUST BE EXHAUSTED
OUTDOORS.
■ Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■ Do not use plastic or metal foil vent.
Exhaust hoods:
■ Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as owers, rocks, bushes,
or snow).
Recommended Styles:
Determine vent length and elbows needed for best
drying performance:
■ Use the following “Vent System Chart” to determine the type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in the “Vent System Chart.” Exhaust systems longer than
those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent System Charts provide venting requirements that will help
achieve best drying performance.
Vent System Chart
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Number of
90° elbows
Type of vent
Angled
hoods
0 Rigid metal 64 ft. (20 m)
1 Rigid metal 54 ft. (16.5 m)
2 Rigid metal 44 ft. (13.4 m)
3 Rigid metal 35 ft. (10.7 m)
4 Rigid metal 27 ft. (8.2 m)
NOTE: Bottom exhaust installations have a 90° turn inside the dryer. To
determine maximum exhaust length, add one 90° turn to the chart.