Maytag M8RXEGMAB, M8RXEGMAW, M8RXEGMAS Dimension Guide

F
Top Mount Refrigerator
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
LOCATION REQUIREMENTS
M8RXEGMX M8RXEGMA
Electrical: A 115-volt, 60-Hz, AC-only, 15- or 20-amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.
Water: A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate ice maker and water dispenser. If you have questions about your water pressure, call a licensed, qualified plumber.
IMPORTANT: The pressure of the water coming out of a reverse osmosis system going to the water inlet valve of the refrigerator needs to be between 30 and 120 psi (207 and 827 kPa).
Reverse Osmosis Water Supply: If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10214132A
9/21/10
C
D
top of
cabinet
B
A
E
overall
To ensure proper ventilation for your refrigerator, allow for a 1⁄2" (1.25 cm) space on each side. Allow 3" (7.5 cm) of space between overhead cabinets and refrigerator top. Allow at least 1" (25.40 mm) between back of cabinet and the wall. If your refrigerator has an ice maker, make sure you leave some extra space at the back for the water line connections.
If you are installing your refrigerator next to a fixed wall, leave 2" (5.08 cm) minimum on the hinge side (depending on your model) to allow for the door to swing open.
NOTE: It is recommended that you do not install the refrigerator near an oven, radiator, or other heat source, nor in a location where the temperature will fall below 55°F (13°C).
Model Size
Depth
“A”
Cab. Width
“B”
Door Width
“C”
Cab. Height
“D”
Overall
Height
“E”
Depth Door
Open 90°
“F”
17.5 cu. ft.
303⁄8"
(77.2 cm)
28"
(71.1 cm)
281⁄8"
(71.4 cm)
673⁄8"
(171.0 cm)
68"
(173.0 cm)
543⁄8"
(138.1 cm)
Dimensions “D” and “E” include rollers
extended
3
4" (1.9 cm)
90˚
" (7.5 cm)
3
1
/
2" (1.25 cm)
2" (5.08 cm)