www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Electric Dryers:
LDE9206ADE and LDE9206ADM
14" max.
• Dimensions (Actual Size) •
Width:
28 1/2"
Height including control panel:
Height NOT including control panel:
Depth with door open:
Minimum distance from working surface to
cabinets directly above:
Maximum depth of cabinet directly above:
Minimum clearance from back wall:
Minimum distance to door in front:
Minimum clearance right and left:
Door width:
Rear recess:
Depth:
43 5/8"
36"
26 3/4"
50 1/2"
17"
14"
0"
2"
0"
24"
1 1/4"
Side View
(not to scale)
1 1/4"
Left
side
vent
0"
3 3/4"
3 3/4"
26 3/4"
Closet door
2" min.
Front View
• Additional Information •
• Electrical requirements: 240V, 60Hz, 30 ampere
grounded, fused electrical supply is required. An
individual branch (or separate circuit serving only this
appliance is recommended). Service cord NOT
provided. You MUST use Maytag conversion kit when
converting to 208 volt.
• Maximum amperage draw is 7 amps (during ignition).
• Minimum wire size of 10 gauge (No. 12 preferred),
copper wire only.
• When installed next to Maytag Washer, the overall
width is 54".
• Flush to wall installation possible.
• Exhaust requirements:
- Dryer may be vented out rear, left side or through
floor (when venting left of down use Kit 304652).
- Dryer must be exhausted to the outside.
- Use a minimum of 4" diameter rigid aluminum or rigid
galvanized steel duct.
- Keep exhaust as straight and short as possible.
Exhaust systems longer than the chart on page 2 will
extend drying time, affect machine performance and
collect lint.
- Termination hood should have at least 12" of
clearance between the bottom of the hood and the
ground or other obstructions.
- Back pressure must not exceed 0.58" of water column
when measured with a manometer.
See page 2 for additional information
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
337
0" wall clearance
on both sides
(looking out into room)
17"
Back of unit
13 7/16"
3 3/4"
24"
28 1/2"
Rear and Floor Venting
Back wall
Floor
BN120 • A337B149 • 30626 • 003006 • 224834 • 30975
(not to scale)
43 5/8"
36"
(not to scale)
5 1/8"
15 1/8"
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Product installation in an alcove area or a closet requires sufficient
make-up air. Each make-up air opening must have a minimum of 36
square inches (more is better). These openings must not be
obstructed. A louvered door with equivalent air opening is acceptable.
• LDE9206ADE: Monochromatic White.
• LDE9206ADM: Monochromatic Almond.
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Electric Dryers:
LDE9206ADE and LDE9206ADM
Maximum duct length chart
48 sq. in.
36 sq. in.
Minimum air openings
when installing behind
doors
36 sq. in.
24 sq. in.
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
3"
3"
Number
of 90°
turns
4"
0 54 ft 44 ft
1 43 ft 33 ft
2 36 ft 26 ft
3 30 ft 20 ft
4 24 ft 14 ft
0 26 ft 19 ft
1 22 ft 17 ft
2 18 ft 15 ft
3 15 ft 13 ft
4"
2 1/2"
Maximum length of
4" dia. rigid metal duct
Maximum length of
4" dia. flexible metal duct
BN120 • A337B149 • 30626 • 003006 • 224834 • 30975
149