Maytag KGSC100S, GSU-300, KGCG260S, KGCS160S, GSUG-360 Installation Instructions Manual

...
UILT-IN GAS COOKTOPS
30” MODELS: KGCSIOOS
GSU-300
36” MODELS: KGCG260S, KGCSl6OS,
GSUG-360, GSlJ-360
INSTALLATION
INSTRUCTIONS
INSTALLER: FINAL CHECK LIST
0 1. Specified clearances maintained to adjacent surfaces and front of countertop. 0 2. Burner box securely anchored to cabinet top.
ELECTRICAL
0 1. Polarized three wire 1 POVAC, 60 Hz, with proper receptacle and overcurrent protection accord-
ing to specifications given in this booklet.
GAS SUPPLY
0 1. Supply line of l/z” Black Iron pipe provided. 0 2. Pressure regulator shipped with unit connected to manifold. 0 3. Manual shuloff valve installed in accessible location. 0 4. Unit tested for gas leaks.
OPERATIONAL
q
1. If used on LP gas, verify that pressure regulator and orifice hoods have been modified for use with LP.
0 2. Burners are properly positioned.
0 3. Knobs installed on valve stems. 0 4. Each burner lights satisfactorily.
q
6. Flame adjustment of l/z “
soft
blue cone made on each burner.
q
6. Low flame adjustment verified.
0 7. Drip rings and grates correctly positioned.
q
8. Grill/Griddle Models - Indicator light comes on when grill/griddle element is turned on.
0 9. Grill/Griddle Models - Pan/element assembly is property assembled as shown in Figure 4. 0 10. Grill/Griddle Models - Place cover over grill or griddle.
0 11. Unless instructed t0 leave for owner, remove all tags, labels and internal packing materials. FOR MAINTENANCE - See Use 8 Care Guide. TO LIGHT YOUR COOKTOP DURING POWER OUTAGE - See Use & Care Guide.
THANK YOU INSTALLER:
1. Complele Installation Check List.
2. Leave all literature for customer.
3. Notify dealer that installation is completed.
-
FOR DETAILED INSTRUCTIONS, FOLLOW METHODS DESCRIBED IN THIS FOLDER.
IMPORTANT: Read before installing to save time, work,
assure proper performance, and owner’s warranty protection.
INSTALLATION INSTRUCTIONS
.- -4:
.:.-.=z; ,,_,
The installation of the cooktop must conform to local codes and utility regulationsand should be made only by a qualified technician. In the absence of local codes, the installation must follow the National Fuel Gas Code, ANSI Z 223.1a-1987 and the National Electrical Code, ANSVNFPA No. 70-1987. When installed in a mobile home the installation must conform with Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280) or when such standard is not applicable, with local codes. See Electrical Connection section for circuit requirements.
CABINET CONSTRUCTION
This surface unit is designed for installation in a base cabinet with a countertop depth of 24”. The maximum depth for overhead cabinets is 13 “.
See Figure 16. The minimal vertical clearance between the cooking sur­face and overhead cabinets is 30 “. Overhead cabinets installed at either side of the appliance must be a minimum of 18” above the cooking surface. See Figure 1A. Also see Figure 1A for the minimal horizontal distance be­tween the overhead cabinets to either side of the appliance for your model. Minimal distances between the front edge of the countertop and the front edge of the cooktop are given in Figure 1B for your model.
Grill/Griddle units - Units must be used in conjunction with a suitable vent hood. Cooking utensils should not
be used on the grill/griddle section of the cooktop.
Note: To reduce the risk of burns or fire by reaching over heated surface units, cabinet storage above the sur-
face units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing
a range hood that projects horizontally a minimum of 5” beyond the bottom of the cabinets.
r
30” MINIMUM MODELS: KGCSlOOS, GSU-300
t’
COOKTOP
El=
MINIMUM - au -
30”
k---J” -
J-
MINIMUM
MINIMUM
MINIMUM
1
I \
Figure 1A
7
El”
MINIMUM
1
COUNTERTOP
3/q’ MINIMUM MODELS:
KGCSlOOS, GSU-300
I” MINIMUM
II
MODELS: KGCG260S. GSUG-360, KGCSIGOS. GSU-360
EASE CABINET
Figure 1B
The burner box is 3% II deep. Additional clearance is required under the back 6” of the burner box for fuel and power connections. See Figure 5. The minimal clearances between the cooktop and adjacent vertical combusti­ble surfaces is 3 II on either side and 1 II in the back. See Figures 1 A and 1 B. Use Figure 2, below, for new
inStah
tions or use Figure 3 below for replacement installations. FOR NEW INSTALLATIONS ONLY FOR REPLACEMENT INSTALLATIONS ONLY
Note: When the cutout illustration, given below, is followed the minimal side and back clearances to ad­jacent vertical combustible surfaces will be met.
COUNTERTOP
f
CUTOUT DIMENSIONS FOR
NEW INSTALLATIONS
30” MODELS
Width
“B” Dim.
I
27 ”
47/ ‘1
Figure 2
36 ” MODELS
33% ”
4’/2 ”
Note: In order to comply with AGA safety standards the minimal side and back clearances to adjacent vertical combustible surfaces of 3 II and 1 II must be met when installing this unit. See Figures 1A and 16.
CWNTERTOP
L 4 CORNERS
DEPTH
BASE CABINET
CUTOUT DIMENSIONS FOR
REPLACEMENT INSTALLATIONS
36” MODELS
Minimum
33 ”
Maximum
347/‘ ”
Width
Depth
30” MODELS
Minimum Maximum
26% ” 295/ ” 18% ”
205/, ” 16% ” 205/ ”
Figure 3
ELECTRICAL CONNECTION
WARNING: THIS COOKTOP IS PROVIDED WITH A POLARIZED THREE PRONG PLUG. IT IS NECESSARY THAT THE OUTLET TO WHICH THIS PLUG IS CONNECTED BE PROPERLY POLARIZED AND GROUNDED. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, A QUALIFIED ELECTRICIAN SHOULD BE CONTACTED.
This unit requires a polarized three wire grounded receptacle connected to a 120 VAC, single phase, 60 hertz. See chart below for overcurrent protection circuit size for your model. The receptacle must be installed below the cooktop so that the service cord supplied with the unit may be easily removed for servicing or cleaning the cooktop. (See Figure 5 under “Connecting Unit to Gas” for locations.) This unit must be elec­trically grounded in accordance with local codes, or in their absence, with the National Electrical Code, ANSI/ NFPA No. 70-1987.
KGCSl OOS, GSU-300 KGCS16OS, GSU-360
KGCG260S, GSUG-360
OVERCURRENT PROTECTION
15 OR 20 AMPERES
20 AMPERES
CIRCUIT SIZE
PLUG WITH GROUND PRONG
PROPERLY POLARIZED AND
Recommended Method
GROUNDED RECEPTACLE
*-