• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• Refer to Service Manual 16026929 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.
CAUTION
!
All safety information must be followed as provided in Service Manual 16026929.
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Model JDS8850BD* JDS9860BD* JDS9865BD*
Power Source @ 120/240 V (120/208 V) Kw
Convection element and fan Yes Yes Yes
Downdraft fan No Yes Yes
Warming drawer Yes No No
E-Burner No Yes Yes
Oven meat probe Yes Yes Yes
Child lockout Yes Yes Yes
Sabbath mode Yes Yes Yes
Door activated oven light Yes Yes Yes
Electronic control and ignition Yes Yes Yes
**Rating of 208 VAC is approximately 80% of 240 VAC value.
Page 2
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Component Testing Procedures
Illustration Component Test Procedure Results
C
(JDS8850BD*)
Oven light & housing Disconnect connector and test
resistance of terminals...........................
Measure voltage at oven light ................
Door plunger switch Remove switch from unit and measure
the following points:
Door closed ........................................
Door open...........................................
Autolatch assembly Disconnect wires and test for
continuity per wiring diagram .................
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
Door lock switch Switch connection in the following
N
O
O
M
positions:
Door latch locked................................
Door latch unlocked............................
Pressure regulator Verify gas pressure (W.C.P.). ................
If on LP service verify proper gas
supply conversion.
Verify bulb is properly inserted.
Continuity with bulb inserted.
120 VAC, see wiring diagram for terminal
identification.
If voltage is not present at oven light,
check wiring or light switches.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Illustration Component Test Procedure Results
L
(JDS8850BD*)
(JDS986*BD*)
AB
A1
Spark module 4 + 0 Test for voltage at terminals L and N .....
B1N
Snap switch
(pan switch)
NOTE: Downdraft
fan will not engage
if this switch is not
Check polarity and ground.....................
Test for voltage at terminals ..................
Disconnect wiring and check for
continuity in LITE position......................
activated.
Dual burner valve
Verify gas is supplied.............................
Orifices adjusted for
Natural or LP.
Burner valve,
push-to-turn, 270°
5 K btu
9.2 K btu
16 K btu
Burner valve,
push-to-turn, 270°,
E-burner
Verify gas is supplied.............................
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control.
Verify gas is supplied.............................
Orifice adjusted for
Natural or LP.
Orifice holder
5 K btu
9.2 K btu
16 K btu
Adjust set screw for simmer control.
Verify gas pressure ...............................
Check orifice for debris..........................
120 VAC
See wiring diagram.
120 VAC
Continuity in LITE position.
Gas supplied.
Gas supplied.
Gas supplied.
5" Natural
10" LP/propane
Clean as needed.
(JDS8850BD*)
Orifice holder,
dual burner
12 K btu
3 K btu
(JDS8850BD*)
Spark switch Test for voltage at terminals ..................
(JDS986*BD*)
Spark switch Test for voltage at terminals ..................
(JDS986*BD*)
Double valve switch Test for voltage at terminals ..................
Temperature sensor Measure resistance ............................... Approx 1000 Ω at room temperature,
Convection element Disconnect wiring to element and
Verify gas pressure ...............................
Check orifice for debris..........................
Disconnect wiring and check for
continuity in LITE position......................
Disconnect wiring and check for
continuity in LITE position......................
Disconnect wiring and check for
continuity in LITE position......................
measure cold resistance of terminals. ...
Measure voltage at convect element .....
5" Natural
10" LP/propane
Clean as needed.
120 VAC
Continuity in LITE position.
120 VAC
Continuity in LITE position.
120 VAC
Continuity in LITE position.
75° F (23.8° C).
Approx. 16.5 Ω.
240 VAC.
Page 4
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Illustration Component Test Procedure Results
(JDS986*BD*)
(JDS986*BD*)
E-burner assembly Verify gas is supplied................................. Gas supplied,
E-burner ignitor Test for resistance of spark lead................
Test ignitor to chassis ................................
Check for obstructions in burner ports.
Continuity.
No continuity from ignitor to chassis.
(JDS986*BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS8850BD*)
(JDS8850BD*)
E-burner tube, front Nominal air shutter setting .........................
E-burner tube, rear Nominal air shutter setting .........................
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Illustration Component Test Procedure Results
(JDS986*BD*)
Downdraft motor
NOTE: Downdraft
fan will not engage
if pan (snap) switch
is not activated.
Electronic control
Measure voltage ........................................
Check motor windings to ground ...............
NOTE: To avoid equipment damage,
120 VAC.
No continuity.
RPM: 1550
AMPERAGE: Approx. 2.4
use caution when checking electronic
Cooling fan motor Measure voltage ........................................
control circuitry voltages.
Check motor windings to ground ...............
120 VAC.
No continuity.
RPM: Approx. 1670 to 2070
AMPERAGE: Approx. .22
MODE FAN ON TEMP F (C) FAN OFF TEMP F (C)
Bake 300 (148.9 C) 275 (135 C)
Broil Immediately 275 (135 C)
Clean Immediately 275 (135 C)
COOLING FAN TEMPERATURES
Control Component Test Procedure Results
Switch membrane assembly
JDS9865BD*
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 7 are shorted together for control
configuration purposes
Trace # 1
Latch
See Detail B
Detail B
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Control Component Test Procedure Results
Switch membrane assembly
JDS8850BD*
Switch membrane assembly
JDS9860BD*
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature Access Procedure Modification Procedure
Control Reset
Resets control to factory default
values.
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 7 are shorted together for control
configuration purposes
Trace # 1
Latch
See Detail B
Detail B
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 7 are shorted together for control
configuration purposes
Trace # 1
Latch
See Detail B
Detail B
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left
ATM pad to select SERVICE menu options.
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Rapid Preheat
Warming Drawer
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Press and hold the Back and Enter pads
for 5 seconds to enter SERVICE menu
options. Press the right ATM pad to scroll
to CONTROL RESET. Press the left ATM
pad to select CONTROL RESET, then
press the left ATM pad again to reset the
control logic. Press Setup to exit.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Electronic Oven Control (EOC) III Testing Procedures
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature Access Procedure Modification Procedure
Oven Temperature Adjustment
Determines oven cavity offset
temperature (range from -35° F to
+35° F, or -21° C to +21° C).
Time Options
Determines control time, day of
week, 12/24 hour clock.
Time Set
Determines time of day (Monday
through Sunday) to display on
control.
Day of Week
Determines day of week (Monday
thru Sunday) to display on control
12/24-Hour Clock Display
Determines 12-hour or 24-hour
clock display on control.
Clock & Day Display Disable
Determines if time of day and day
of week will display on control.
Language Display
Determines language display on
control (English, French, Spanish).
C/F (Celsius/Fahrenheit ) Display
Determines temperature display
on control (C or F).
Auto Convection
When enabled, reduces the
Convection Bake and Pastry
temperatures by 25° F (-3.9° C).
Sabbath Mode
Bases on the Jewish guidelines for
Sabbath/Holiday requirements.
Tone Options
Determines cook tones, timer
tones and volume settings.
12-Hour Shutoff
Disables 12-hour shutoff, allowing
the oven to operate indefinitely.
Press the Setup pad, then press the right
ATM pad until TEMP ADJUST displays.
Press the left ATM pad to select oven TEMP
ADJUSTMENT settings.
Press the Setup pad, then the left ATM pad
to select TIME OPTIONS.
Press the Setup pad, then the left ATM pad,
then the left ATM pad again to set the time of
day clock.
Press the Setup pad, then the left ATM pad,
then press the right ATM pad until DAY
displays. Press the left ATM pad to set the
day of the week.
Press the Setup pad, then the left ATM pad,
then press the right ATM pad until 12/24HR
displays. Press the left ATM pad to select
12/24 HR clock.
Press the Setup pad, then press the right
ATM pad until DISABLE displays. Press the
left ATM pad to select DISABLE settings.
Press the Setup pad, then press the right
ATM pad until LANGUAGE displays. Press
the left ATM pad to set LANGUAGE settings.
Press the Setup pad, then press the right
ATM pad until C/F displays. Press the left
ATM pad to select C/F settings. Press the Setup pad, then press the right
ATM pad until AUTO CONVECT displays.
Press the left ATM pad to select AUTO
CONVECT settings.
Press the Setup pad, then press the right
ATM pad until SABBATH displays. Press the
left ATM pad to select SABBATH settings.
Press the Setup pad, then press the right
ATM pad until TONES displays. Press the
left ATM pad to select TONES options.
Press the Setup pad, then press the right
ATM pad until 12HR Shutoff displays. Press
the left ATM pad to select 12-HOUR
SHUTOFF settings.
Enter the offset temperature setting desired
using the digits pads. Press the right ATM pad
for + temperature adjustment, or the left ATM
pad for – temperature adjustment. Press 0 to
reset control back to no temperature
adjustment. Wait 3 seconds for the control to
accept the request. Press Setup to exit.
Press the right ATM pad to scroll to the desired
function to modify.
Enter the correct time using the digits pads and
press Enter. Press the left ATM pad to select
AM or the right ATM pad to select PM. Press
Setup to exit.
Press the right ATM pad until the correct day
displays, then press the left ATM pad to select.
Press Setup to exit.
Press the left ATM pad to select 12-hour clock,
or the right ATM pad to select 24-hour clock.
Press Setup to exit.
Press the left ATM pad to select TIME, or the
right ATM pad to scroll to DAY, then press the
left ATM pad. Press the left ATM pad to turn
display on or the right ATM pad to turn display
off. Press Setup to exit.
Press the right ATM pad until the desired
language displays (English, French, Spanish).
Press the left ATM pad. Press Setup to exit.
Press the left ATM pad to select Celsius or the
right ATM pad to select Fahrenheit. Press
Setup to exit.
Press the left ATM pad to turn on auto convect,
or the right ATM pad to turn off auto convect.
Press Setup to exit.
Press the left ATM pad to select Manual
Sabbath mode, or the right ATM pad to select
Auto Sabbath mode. Press the left ATM pad to
turn on Sabbath mode, or the right ATM pad to
turn off Sabbath mode. Press Setup to exit.
Press the right ATM pad to scroll to the desired
tone to modify.
Press the left ATM pad to turn on 12-hour
shutoff, or the right ATM pad to turn off 12-hour
shutoff. Press Setup to exit.
Page 8
Component & Oven Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Feature Access Procedure Modification Procedure
208/240 V Setting
Determines range operating
voltage (208 or 240 VDC).
Cook Tones
Determines the number and
duration of cook time
reminder chimes.
Timers Tones
Determines the number and
duration of timer reminder
chimes.
Volume
Determines volumes of cook
and timer tones.
Energy Saver Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters into a sleep mode.
Demo Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters into a sleep mode.
Service Mode
Enables access to service
menus.
Test Access
Enables access to service
menus.
Faults Access
Displays the 10 most recent
faults produced by the
controller.
Software Versions Access
Displays the software and
EEPROM revision levels.
Display Test
Illuminates all lamps on the
control.
Control Lockout
Disables the touch keypad
control and locks the oven
cavity door.
Press the Setup pad, then press the right ATM
pad until 208/240 displays. Press the left ATM
pad to select 208/240 V settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM
pad. Press the left ATM pad again to select
COOK TONES settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM
pad. Press the right ATM pad to scroll to TIMERS
TONES. Press the left ATM pad to select
TIMERS TONES settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM pad
to select VOLUME settings.
Press the Setup pad, then press the right ATM
pad until ENERGY SAVER displays. Press the
left ATM pad to select ENERGY SAVER mode
settings.
Press the Setup pad, then press the right ATM
pad until DEMO displays. Press the left ATM pad
to select DEMO mode settings.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Back and Setup pads simultaneously
for 5 seconds to lock.
Press the left ATM pad to select 208 VDC, or the
right ATM pad to select 240 VDC. Press Setup
to exit.
Press the left ATM pad to select 1 – 30 (1 chime
every 30 seconds after the initial 4 chimes), or
press the right ATM pad to scroll to 1 – 60 (1
chime every 60 seconds after the initial 4 chimes)
or 1 BEEP (no additional chimes after the initial 4
chimes). Press the left ATM pad to select the
desired setting. Press Setup to exit.
Press the left ATM pad to select 2 – 30, or 2
chimes every 30 seconds for up to 5 minutes
(after the initial chime), or press the right ATM
pad to scroll to 2 – 60, or 2 chimes every 60
seconds for up to 30 minutes (after the initial
chime), or 1 BEEP (no additional chimes after the
initial chime). Press the left ATM pad to select
the desired setting. Press Setup to exit.
Press the right ATM pad until VOLUME displays.
Press the left ATM pad. Press the left ATM pad
to select HIGH, or the right ATM pad to scroll to
MEDIUM or LOW. Press the left ATM pad to
select desired setting. Press Setup to exit.
Press the left ATM pad to enter the energy saver
mode or the right ATM pad to exit the energy
saver mode. Press Setup to exit.
Press the left ATM pad to enable the DEMO
mode or the right ATM pad to exit the DEMO
mode. Once the DEMO mode begins, press any
key to exit. Press Setup to exit, also.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to TEST menu. Press
the left ATM pad to select TEST options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the FAULTS menu.
Press the left ATM pad to select FAULTS
options. Press Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the VERSIONS
menu. Press the left ATM pad to view. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to DISPLAY TEST.
Press the left ATM pad. Press Setup to exit.
Press the Back and Setup pads simultaneously
for 5 seconds to unlock.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
WARNING
Relay Logic for EOC III
NOTE: Subsequent changes implemented after the release of this technical sheet may have altered the parameters
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
WARNING
"Quick Test" Mode for EOC III
Follow the procedure below to perform the EOC III quick test. Once the control is in the quick test mode, any relay
may be activated in any sequence. The test mode will be exited after 10 minutes of inactivity (no pads pressed
within 10 minutes).
1. Press the Setup pad, then press the right ATM pad.
2. Press the left ATM pad, then press and hold Back and Enter pads for 5 seconds to enter SERVICE menu options.
3. Press the right ATM pad to scroll to the TEST menu.
4. Press the left ATM pad to select TEST options.
5. Press the left ATM pad again to enter the "Quick Test" mode.
6. Press each of the following pads indicated in the table below.
7. Press Cancel or Setup pads to exit. NOTE:Press and hold the applicable pad to activate the associated response.
Release the applicable pad to deactivate the associated response.
The control automatically enters the engineering mode so visual feedback of relay operations is available on the
control display. Any time a load is activated, the cooling fan is activated. When the load is deactivated, the cooling
fan is also deactivated.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Description of Fault Codes for EOC III
Each fault code consists of 4 digits and is structured as follows:
1st (Leftmost) Digit:
Primary Failure System
1 – Local to Control System d – Diagnostic Failure (measurable)
3 – Sensor or Meat Probe c – Control-Related Error (not measurable)
4 – Input to Control System
9 – Door Lock
If a fault is detected, then one of the following three messages will be scrolled on the display:
FAULT DETECTED PRESS ENTER TO TRY AGAIN. This message displays when a fault is detected while a
cooking function is active. Clear by pressing the Cancel keypad.
FEATURE NOT AVAILABLE. This message displays when a fault is detected while entering data during initial
programming and also when a locked out function is detected. Clear by pressing any key.
FAULT DETECTED DISABLE POWER TO CLEAR. This message displays when a runaway temperature condition
is detected while the control is in idle mode. Press any key to clear the message, but the fault remains until the
control senses a Power-On reset.
Fault
Code
1c1c Shorted key.
1c2c Membrane keyboard disconnected.
1c4c Board – to – Board communication failure. Replace control.
1c6c EEPROM hardware fault. Replace control.
1c7c Control not calibrated. Replace control.
1c8c EEPROM CRC error – User Options. Replace control.
1c81 EEPROM CRC error – Cook Profile. Replace control.
1d11 Unlocked runaway temperature – 600°
1d21 Locked runaway temperature – 950°
3d11 Temperature sensor open.
3d21 Temperature sensor shorted.
3d41 Meat probe shorted.
3d51 Meat probe not calibrated.
4d11 Door switch not closed when locked. Check connections, switch, harness, and motor. If OK, replace control.
4d21 No cooling fan rotation. Check cooling fan motor and harness. If OK, replace control.
4d31 Cooling fan on when de-energized. Check cooling fan motor and harness. If OK, replace control.
4d41 Cooling fan overspeed. Check cooling fan motor and harness. If OK, replace control.
4d51 Door switch circuit fault. Check connections, harness, and motor. If OK, replace control.
9d11 Latch will not lock. Check wire connections. If OK, replace motorized door lock.
9d21 Latch will not unlock. Check wire connections. If OK, replace motorized door lock.
9d31 Latch both locked and unlocked. Check wire connections. If OK, replace motorized door lock.
Description Component to Troubleshoot/Replace
2nd Digit: Alpha-Character 3rd Digit: Secondary
Failure Mechanism
Ensure ribbon cable is securely connected, inspect ribbon cable and
connector (shorts, breakage, corrosion, etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect ribbon cable and
connector (shorts, breakage, corrosion, etc.). If OK, replace control.
Ohm sensor and harness (see "Oven Sensor" chart). If OK, change
control.
Ohm sensor and harness (see "Oven Sensor" chart). If OK, change
control.
Check connections, sensor (see "Oven Sensor" chart) and harness. If
OK, replace control.
Check connections, sensor (see "Oven Sensor" chart) and harness. If
OK, replace control.
Check probe jack and harness. If OK, check meat probe (see "Meat
Probe" chart).
Check probe jack and harness. If OK, check meat probe (see "Meat
Probe" chart).
4th Digit : Oven
Cavity Number
1 – Upper (Single) Oven
2 – Lower Oven
c – Control System
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Gas Conversion: JDS986*BD*
Pressure Regulator Conversion
1. Remove cap and force plastic plunger from
bottom of cap.
2. Turn plunger over and force back into original
location.
NOTE: Plunger must snap into position and the type of
gas being supplied (NAT or LP) must be visible
on lower side of plunger.
JDS986*BD* Pressure Regulator Conversion
WARNING
Natural
LP
Gas Conversion: JDS8850BD*
Pressure Regulator Conversion
1. Remove plastic dust cover from cap nut (top of
regulator) and remove cap nut.
2. Remove plastic dust cover from cap nut and reinstall
on opposite side of cap nut.
3. Reinstall cap nut into regulator, replace dust cover.
NOTE: The marking for the type of gas being supplied
(NAT or LP) must be visible in top of cap nut.
Natural
LP
JDS8850BD* Pressure Regulator Conversion
Orifice Conversion:
1. Remove grates, burner caps, screws and burner
heads (and grill, on models JDS986*BD*).
2. Converting one burner at a time, remove existing
orifice hoods and install new orifice hood (see chart
below), screw down tight. Do not over tighten.
3. Replace grates, burner caps, screws and burner
heads (and grill, on models JDS986*BD*).
Low Flame Adjustment:
1. Adjusting one burner at a time, turn burner control
knob to lowest position and remove knob.
2. Insert screwdriver into knob stem to engage
adjustment screw and adjust flame height (no blue
lifting or yellow flame).
3. Replace burner control knob.
RF
RR
GRILL
Natural LP
1.95 mm Red (1.14 mm)
Green (1.07 mm) Blue (.69 mm)
Green (1.07 mm) .033 mm
Orifice Conversion:
1. Remove burner grates, caps, screws and heads.
2. Converting one burner at a time, remove existing
orifice hoods and install new orifice hood (see chart
below), screw down tight. Do not over tighten.
3. Replace burner grates, caps, screws and heads.
Low Flame Adjustment:
1. Adjusting one burner at a time, turn burner control
knob to lowest position and remove knob.
2. Insert screwdriver into knob stem to engage
adjustment screw and adjust flame height (no blue
lifting or yellow flame).
3. Replace burner control knob.
NOTE: Drop in LP CHOKE after replacing burner heads
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.