Maytag JDS8850BD, JDS9860BD, JDS9865BD Technical Information

Page 1
Technical InformationDual Fuel Slide-In Range
JDS8850BD* JDS9860BD* JDS9865BD*
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
Refer to Service Manual 16026929 for detailed installation, operating, testing, troubleshooting, and disassembly instructions.
!
All safety information must be followed as provided in Service Manual 16026929.
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Model JDS8850BD* JDS9860BD* JDS9865BD* Power Source @ 120/240 V (120/208 V) Kw
Electrical rating 3.6 (2.7) 3.6 (2.7) 3.6 (2.7) Amperage rating 40 Amp 40 Amp 40 Amp Frequency 60 Hz 60 Hz 60 Hz
Water Column Pressure
Natural 5 in. W.C.P. 5 in. W.C.P. 5 in. W.C.P. LP/Propane 10 in. W.C.P. 10 in. W.C.P. 10 in. W.C.P.
Surface Burner BTU Nat. (LP)
Right front 16,000 (14,000) 16,000 (14,000) 16,000 (14,000) Right rear 5,000 (4,000) 5,000 (4,000) 5,000 (4,000) Left front 15,000 (13,000) 8,500 (8,000) 8,500 (8,000) Left rear 9,200 (9,100) 8,500 (8,000) 8,500 (8,000)
Elements, Oven Wattage @ 240 V (208 V)**
Bake, hidden 2,800 (2,100) N/A N/A Bake N/A 2,400 (1,850) 2,400 (1,850) Broil, 8-pass 3,600 (2,700) 3,600 (2,700) 3,600 (2,700) Convection 3,400 (2,500) 3,400 (2,500) 3,400 (2,500) Warmer drawer 550 (400) N/A N/A
Oven Interior Dimensions in. (cm)
Height 18 1/8 (46) 16 1/2 (41.9) 16 1/2 (41.9) Width 23 (58.4) 23 (58.4) 23 (58.4) Depth 18 5/8 (47.3) 17 1/2 (44.4) 17 1/2 (44.4)
Product Exterior Dimensions in. (cm)
Height Overall 36 (91.4) 36 (91.4) 36 (91.4) Width 29 7/8 (75.9) 29 7/8 (75.9) 29 7/8 (75.9) Depth-oven door closed, excl. handle 26 3/16 (66.5) 26 3/16 (66.5) 26 3/16 (66.5) Depth-oven door closed, incl. handle 28 3/16 (71.6) 28 3/16 (71.6) 28 3/16 (71.6)
Features
Convection element and fan Yes Yes Yes Downdraft fan No Yes Yes Warming drawer Yes No No E-Burner No Yes Yes Oven meat probe Yes Yes Yes Child lockout Yes Yes Yes Sabbath mode Yes Yes Yes Door activated oven light Yes Yes Yes Electronic control and ignition Yes Yes Yes
Weight lbs. (kg)
Approximate shipping weight 205 (93) 205 (93) 205 (93)
February 2006 1 16026930
© 2006 Maytag Services
**Rating of 208 VAC is approximately 80% of 240 VAC value.
Page 2
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Component Testing Procedures
Illustration Component Test Procedure Results
C
(JDS8850BD*)
Oven light & housing Disconnect connector and test
resistance of terminals...........................
Measure voltage at oven light ................
Door plunger switch Remove switch from unit and measure
the following points:
Door closed ........................................
Door open...........................................
Autolatch assembly Disconnect wires and test for
continuity per wiring diagram .................
Refer to Parts Manual for correct autolatch switch associated with the correct manufacturing number.
Door lock switch Switch connection in the following
N
O
O
M
positions:
Door latch locked................................
Door latch unlocked............................
Pressure regulator Verify gas pressure (W.C.P.). ................
If on LP service verify proper gas supply conversion.
Verify bulb is properly inserted. Continuity with bulb inserted. 120 VAC, see wiring diagram for terminal identification. If voltage is not present at oven light, check wiring or light switches.
COM-NO= Continuity (closed) COM-NO= Infinity (open)
See wiring diagram for schematic layout.
Common is in neutral position unless locking or unlocking autolatch assembly.
COM-NO= Continuity (closed) COM-NO= Infinity (open)
5" Natural 10" LP/propane
(JDS986*BD*)
(JDS8850BD*)
(JDS8850BD*)
Pressure regulator Verify gas pressure (W.C.P.). ................
5" Natural 10" LP/propane
If on LP service verify proper gas supply conversion.
Top surface burner
5 K btu
9.2 K btu 16 K btu
Top surface, dual burner
15 K btu
Inner: 3 K btu
Verify gas is supplied.............................
Verify burner cap is positioned
correctly .................................................
Verify gas is supplied.............................
Verify burner cap is positioned
correctly .................................................
Gas supplied.
Check for obstructions in burner ports.
Gas supplied.
Check for obstructions in burner ports.
Outer: 12 K btu
Top surface,
Verify cap is positioned correctly............ Check for obstructions in burner ports.
burner cap
5 K btu
9.2 K btu 16 K btu
Top surface,
Verify cap is positioned correctly............ Check for obstructions in burner ports.
burner cap, dual (inner and outer burners)
Spark ignition electrode
Test for resistance of spark lead............
Test ignitor to chassis ............................
Continuity
No continuity from ignitor to chassis.
16026930 2 February 2006
© 2006 Maytag Services
Page 3
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Illustration Component Test Procedure Results
L
(JDS8850BD*)
(JDS986*BD*)
AB
A1
Spark module 4 + 0 Test for voltage at terminals L and N .....
B1N
Snap switch (pan switch)
NOTE: Downdraft fan will not engage if this switch is not
Check polarity and ground.....................
Test for voltage at terminals ..................
Disconnect wiring and check for
continuity in LITE position......................
activated. Dual burner valve
Verify gas is supplied.............................
Orifices adjusted for Natural or LP.
Burner valve, push-to-turn, 270°
5 K btu
9.2 K btu 16 K btu
Burner valve, push-to-turn, 270°, E-burner
Verify gas is supplied.............................
Orifice adjusted for Natural or LP.
Adjust set screw for simmer control.
Verify gas is supplied.............................
Orifice adjusted for Natural or LP.
Orifice holder
5 K btu
9.2 K btu 16 K btu
Adjust set screw for simmer control.
Verify gas pressure ...............................
Check orifice for debris..........................
120 VAC
See wiring diagram.
120 VAC
Continuity in LITE position.
Gas supplied.
Gas supplied.
Gas supplied.
5" Natural 10" LP/propane
Clean as needed.
(JDS8850BD*)
Orifice holder, dual burner
12 K btu 3 K btu
(JDS8850BD*)
Spark switch Test for voltage at terminals ..................
(JDS986*BD*)
Spark switch Test for voltage at terminals ..................
(JDS986*BD*)
Double valve switch Test for voltage at terminals ..................
Temperature sensor Measure resistance ............................... Approx 1000 at room temperature,
Convection element Disconnect wiring to element and
February 2006 3 16026930
© 2006 Maytag Services
Verify gas pressure ...............................
Check orifice for debris..........................
Disconnect wiring and check for
continuity in LITE position......................
Disconnect wiring and check for
continuity in LITE position......................
Disconnect wiring and check for
continuity in LITE position......................
measure cold resistance of terminals. ...
Measure voltage at convect element .....
5" Natural 10" LP/propane
Clean as needed.
120 VAC
Continuity in LITE position.
120 VAC
Continuity in LITE position.
120 VAC
Continuity in LITE position.
75° F (23.8° C).
Approx. 16.5 Ω. 240 VAC.
Page 4
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Illustration Component Test Procedure Results
(JDS986*BD*)
(JDS986*BD*)
E-burner assembly Verify gas is supplied................................. Gas supplied,
E-burner ignitor Test for resistance of spark lead................
Test ignitor to chassis ................................
Check for obstructions in burner ports.
Continuity.
No continuity from ignitor to chassis.
(JDS986*BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS986*BD*)
(JDS8850BD*)
(JDS8850BD*)
(JDS8850BD*)
E-burner tube, front Nominal air shutter setting .........................
E-burner tube, rear Nominal air shutter setting .........................
Hidden bake element
Broil element Disconnect wiring to element and
Bake element Disconnect wiring to element and
Warmer element Disconnect wiring to element and
Convection motor, 2-speed
Oven limit switch Normally closed, verify operation:
Oven limit switch Normally closed, verify operation:
Hi-limit temperature switch (Warming Drawer)
Hi-limit temperature switch (Warming Drawer)
Tolerance...................................................
Tolerance...................................................
Disconnect wiring to element and
measure cold resistance of terminals.........
Measure voltage at bake element ..............
measure cold resistance of terminals.........
Measure voltage at broil element ...............
measure cold resistance of terminals.........
Measure voltage at bake element ..............
measure cold resistance of terminals.........
Measure voltage at broil element ...............
Measure voltage ........................................
Check motor windings to ground ...............
Open: 253° to 267° F (123° to 131° C).....
Closed: 188° to 212° F (87° to 100° C) ....
Open: 209° to 221° F (98° to 105° C).......
Closed: 144° to 166° F (62° to 74° C) ......
Normally closed, verify operation:
Open: 135° to 145° F (57° to 63° C).........
Closed: 114° to 126° F (46° to 52° C) ......
Normally closed, verify operation:
Open: 95° to 105° F (35° to 41° C)...........
Closed: 79° to 91° F (26° to 33° C)..........
.250 1/4" .031 Approx. 1/32"
.250 1/4" .031 Approx. 1/32"
Approx. 20 Ω. 240 VAC.
Approx. 12.5 to 18 Ω. 240 VAC.
Approx. 22 Ω. 240 VAC.
Approx. 12.5 to 18 Ω. 120 VAC.
120 VAC. (tolerance: 105 to 135 VAC) No continuity.
RPM, Lo-speed: Approx. 1440 to 2040 RPM, Hi-speed: Approx. 1860 to 2460
Infinite. Continuity.
Infinite. Continuity.
Infinite. Continuity.
Infinite. Continuity.
16026930 4 February 2006
© 2006 Maytag Services
Page 5
Component & Control Testing Procedures
.
.
.
.
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Illustration Component Test Procedure Results
(JDS986*BD*)
Downdraft motor
NOTE: Downdraft fan will not engage if pan (snap) switch is not activated.
Electronic control
Measure voltage ........................................
Check motor windings to ground ...............
NOTE: To avoid equipment damage,
120 VAC. No continuity.
RPM: 1550 AMPERAGE: Approx. 2.4
use caution when checking electronic
Cooling fan motor Measure voltage ........................................
control circuitry voltages.
Check motor windings to ground ...............
120 VAC. No continuity.
RPM: Approx. 1670 to 2070 AMPERAGE: Approx. .22
MODE FAN ON TEMP F (C) FAN OFF TEMP F (C)
Bake 300 (148.9 C) 275 (135 C)
Broil Immediately 275 (135 C)
Clean Immediately 275 (135 C)
COOLING FAN TEMPERATURES
Control Component Test Procedure Results
Switch membrane assembly
JDS9865BD*
Closed circuitry resistance (defined as continuity): 2000 Max Pins 1 & 7 are shorted together for control configuration purposes
Trace # 1
Latch See Detail B
Detail B
Pad
1 2 3 4 5 6 7 8 9 0 Cancel Bake Broil Convect Clean Favorites Rapid Preheat Vent Fan More Options Setup ATM 1 ATM 2 Back Enter Timer 1 Timer 2 Oven Light
Trace
2 & 7 2 & 8 2 & 9 2 & 10 2 & 11 2 & 12 3 & 6 3 & 7 3 & 8 2 & 6 4 & 9 4 & 10 4 & 11 5 & 9 5 & 7 4 & 12 5 & 10 5 & 11 5 & 8 5 & 6 4 & 6 4 & 7 3 & 9 3 & 10 3 & 11 3 & 12 4 & 8
Measurement
Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity
February 2006 5 16026930
© 2006 Maytag Services
Page 6
Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Control Component Test Procedure Results
Switch membrane assembly
JDS8850BD*
Switch membrane assembly
JDS9860BD*
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature Access Procedure Modification Procedure
Control Reset
Resets control to factory default values.
Closed circuitry resistance (defined as continuity): 2000 Max Pins 1 & 7 are shorted together for control configuration purposes
Trace # 1
Latch
See Detail B
Detail B
Closed circuitry resistance (defined as continuity): 2000 Max Pins 1 & 7 are shorted together for control configuration purposes
Trace # 1
Latch
See Detail B
Detail B
Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options.
Pad 1 2 3 4 5 6 7 8 9 0 Cancel Bake Broil Convect Clean Favorites Rapid Preheat Warming Drawer More Options Setup ATM 1 ATM 2 Back Enter Timer 1 Timer 2 Oven Light Pad 1 2 3 4 5 6 7 8 9 0 Cancel Bake Broil Convect Clean Favorites Rapid Preheat Vent Fan More Options Setup ATM 1 ATM 2 Back Enter Timer 1 Timer 2 Oven Light
Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press the right ATM pad to scroll to CONTROL RESET. Press the left ATM pad to select CONTROL RESET, then press the left ATM pad again to reset the control logic. Press Setup to exit.
Trace
2 & 7 2 & 8 2 & 9 2 & 10 2 & 11 2 & 12 3 & 6 3 & 7 3 & 8 2 & 6 4 & 9 4 & 10 4 & 11 5 & 9 5 & 7 4 & 12 5 & 10 5 & 11 5 & 8 5 & 6 4 & 6 4 & 7 3 & 9 3 & 10 3 & 11 3 & 12 4 & 8
Trace
2 & 7 2 & 8 2 & 9 2 & 10 2 & 11 2 & 12 3 & 6 3 & 7 3 & 8 2 & 6 4 & 9 4 & 10 4 & 11 5 & 9 5 & 7 4 & 12 5 & 10 5 & 11 5 & 8 5 & 6 4 & 6 4 & 7 3 & 9 3 & 10 3 & 11 3 & 12 4 & 8
Measurement
Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity
Measurement
Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity
16026930 6 February 2006
© 2006 Maytag Services
Page 7
Control Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Electronic Oven Control (EOC) III Testing Procedures
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature Access Procedure Modification Procedure
Oven Temperature Adjustment
Determines oven cavity offset temperature (range from -35° F to +35° F, or -21° C to +21° C).
Time Options
Determines control time, day of week, 12/24 hour clock.
Time Set
Determines time of day (Monday through Sunday) to display on control.
Day of Week
Determines day of week (Monday thru Sunday) to display on control
12/24-Hour Clock Display
Determines 12-hour or 24-hour clock display on control.
Clock & Day Display Disable
Determines if time of day and day of week will display on control.
Language Display
Determines language display on control (English, French, Spanish).
C/F (Celsius/Fahrenheit ) Display
Determines temperature display on control (C or F).
Auto Convection
When enabled, reduces the Convection Bake and Pastry temperatures by 25° F (-3.9° C).
Sabbath Mode
Bases on the Jewish guidelines for Sabbath/Holiday requirements.
Tone Options
Determines cook tones, timer tones and volume settings.
12-Hour Shutoff
Disables 12-hour shutoff, allowing the oven to operate indefinitely.
February 2006 7 16026930
© 2006 Maytag Services
!
WARNING
Warm Drawer
ATM PADS
Press the Setup pad, then press the right ATM pad until TEMP ADJUST displays. Press the left ATM pad to select oven TEMP ADJUSTMENT settings.
Press the Setup pad, then the left ATM pad to select TIME OPTIONS.
Press the Setup pad, then the left ATM pad, then the left ATM pad again to set the time of day clock.
Press the Setup pad, then the left ATM pad, then press the right ATM pad until DAY displays. Press the left ATM pad to set the day of the week. Press the Setup pad, then the left ATM pad, then press the right ATM pad until 12/24HR displays. Press the left ATM pad to select 12/24 HR clock. Press the Setup pad, then press the right ATM pad until DISABLE displays. Press the left ATM pad to select DISABLE settings.
Press the Setup pad, then press the right ATM pad until LANGUAGE displays. Press the left ATM pad to set LANGUAGE settings. Press the Setup pad, then press the right
ATM pad until C/F displays. Press the left ATM pad to select C/F settings. Press the Setup pad, then press the right ATM pad until AUTO CONVECT displays.
Press the left ATM pad to select AUTO CONVECT settings. Press the Setup pad, then press the right ATM pad until SABBATH displays. Press the left ATM pad to select SABBATH settings.
Press the Setup pad, then press the right ATM pad until TONES displays. Press the left ATM pad to select TONES options. Press the Setup pad, then press the right ATM pad until 12HR Shutoff displays. Press the left ATM pad to select 12-HOUR SHUTOFF settings.
Enter the offset temperature setting desired using the digits pads. Press the right ATM pad for + temperature adjustment, or the left ATM pad for – temperature adjustment. Press 0 to reset control back to no temperature adjustment. Wait 3 seconds for the control to accept the request. Press Setup to exit. Press the right ATM pad to scroll to the desired function to modify.
Enter the correct time using the digits pads and press Enter. Press the left ATM pad to select AM or the right ATM pad to select PM. Press Setup to exit. Press the right ATM pad until the correct day displays, then press the left ATM pad to select. Press Setup to exit.
Press the left ATM pad to select 12-hour clock, or the right ATM pad to select 24-hour clock. Press Setup to exit.
Press the left ATM pad to select TIME, or the right ATM pad to scroll to DAY, then press the left ATM pad. Press the left ATM pad to turn display on or the right ATM pad to turn display off. Press Setup to exit. Press the right ATM pad until the desired language displays (English, French, Spanish). Press the left ATM pad. Press Setup to exit. Press the left ATM pad to select Celsius or the right ATM pad to select Fahrenheit. Press Setup to exit. Press the left ATM pad to turn on auto convect, or the right ATM pad to turn off auto convect. Press Setup to exit.
Press the left ATM pad to select Manual Sabbath mode, or the right ATM pad to select Auto Sabbath mode. Press the left ATM pad to turn on Sabbath mode, or the right ATM pad to turn off Sabbath mode. Press Setup to exit. Press the right ATM pad to scroll to the desired tone to modify.
Press the left ATM pad to turn on 12-hour shutoff, or the right ATM pad to turn off 12-hour shutoff. Press Setup to exit.
Page 8
Component & Oven Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Feature Access Procedure Modification Procedure
208/240 V Setting
Determines range operating voltage (208 or 240 VDC).
Cook Tones
Determines the number and duration of cook time reminder chimes.
Timers Tones
Determines the number and duration of timer reminder chimes.
Volume
Determines volumes of cook and timer tones.
Energy Saver Mode
Enables a 1 watt standby feature. If no pad is pressed within 5 minutes, the control enters into a sleep mode.
Demo Mode
Enables a 1 watt standby feature. If no pad is pressed within 5 minutes, the control enters into a sleep mode.
Service Mode
Enables access to service menus.
Test Access
Enables access to service menus.
Faults Access
Displays the 10 most recent faults produced by the controller.
Software Versions Access
Displays the software and EEPROM revision levels.
Display Test
Illuminates all lamps on the control.
Control Lockout
Disables the touch keypad control and locks the oven cavity door.
Press the Setup pad, then press the right ATM pad until 208/240 displays. Press the left ATM pad to select 208/240 V settings. Press the Setup pad, then press the right ATM pad until TONES displays. Press the left ATM pad. Press the left ATM pad again to select COOK TONES settings.
Press the Setup pad, then press the right ATM pad until TONES displays. Press the left ATM pad. Press the right ATM pad to scroll to TIMERS TONES. Press the left ATM pad to select TIMERS TONES settings.
Press the Setup pad, then press the right ATM pad until TONES displays. Press the left ATM pad to select VOLUME settings.
Press the Setup pad, then press the right ATM pad until ENERGY SAVER displays. Press the left ATM pad to select ENERGY SAVER mode settings.
Press the Setup pad, then press the right ATM pad until DEMO displays. Press the left ATM pad to select DEMO mode settings.
Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options. Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM pad until SERVICE displays. Press the left ATM pad to select SERVICE menu options.
Press the Back and Setup pads simultaneously for 5 seconds to lock.
Press the left ATM pad to select 208 VDC, or the right ATM pad to select 240 VDC. Press Setup to exit. Press the left ATM pad to select 1 – 30 (1 chime every 30 seconds after the initial 4 chimes), or press the right ATM pad to scroll to 1 – 60 (1 chime every 60 seconds after the initial 4 chimes) or 1 BEEP (no additional chimes after the initial 4 chimes). Press the left ATM pad to select the desired setting. Press Setup to exit. Press the left ATM pad to select 2 – 30, or 2 chimes every 30 seconds for up to 5 minutes (after the initial chime), or press the right ATM pad to scroll to 2 – 60, or 2 chimes every 60 seconds for up to 30 minutes (after the initial chime), or 1 BEEP (no additional chimes after the initial chime). Press the left ATM pad to select the desired setting. Press Setup to exit. Press the right ATM pad until VOLUME displays. Press the left ATM pad. Press the left ATM pad to select HIGH, or the right ATM pad to scroll to MEDIUM or LOW. Press the left ATM pad to select desired setting. Press Setup to exit. Press the left ATM pad to enter the energy saver mode or the right ATM pad to exit the energy saver mode. Press Setup to exit.
Press the left ATM pad to enable the DEMO mode or the right ATM pad to exit the DEMO mode. Once the DEMO mode begins, press any key to exit. Press Setup to exit, also.
Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press Setup to exit. Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press the right ATM pad to scroll to TEST menu. Press the left ATM pad to select TEST options. Press Setup to exit. Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press the right ATM pad to scroll to the FAULTS menu. Press the left ATM pad to select FAULTS options. Press Setup to exit. Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press the right ATM pad to scroll to the VERSIONS menu. Press the left ATM pad to view. Press Setup to exit. Press and hold the Back and Enter pads for 5 seconds to enter SERVICE menu options. Press the right ATM pad to scroll to DISPLAY TEST. Press the left ATM pad. Press Setup to exit. Press the Back and Setup pads simultaneously for 5 seconds to unlock.
16026930 8 February 2006
© 2006 Maytag Services
Page 9
Control Testing Procedures
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
Relay Logic for EOC III
NOTE: Subsequent changes implemented after the release of this technical sheet may have altered the parameters
identified in this chart.
INDEX
±
- OFF
O - ON
- CYCLING - ON OR OFF (DETERMINED BY
USER INPUT)
COOKING MODE
IDLE BAKE RAPID PREHEAT BAKE PREHEAT BAKE HIGH BROIL PREHEAT HIGH BROIL LOW BROIL PREHEAT LOW BROIL CLEAN PREHEAT CLEAN KEEP WARM PREHEAT KEEP WARM WARMING DRAWER HIGH WARMING DRAWER LOW CONVECT ROAST PREHEAT CONVECT ROAST CONVECT BAKE RAPID PREHEAT CONVECT BAKE PREHEAT CONVECT BAKE CONVECT PASTRY RAPID PREHEAT CONVECT PASTRY PREHEAT CONVECT PASTRY THAW-SERVE DRYING PREHEAT DRYING RAPID PROOFING STANDARD PROOFING
*Convection fan stops when oven door is opened.
BAKE ELEMENT
BROIL ELEMENT
CONVECT ELEMENT
CONVECT FAN
r r r r r
O
r r r r
O
r r r r
r r r r
O
r r r r
 
O
r r r r r r r r r r r r r r r r r r r r r r r r
r r r r r r r r
r r r
r r r
O
r r r
r r r
r r r
r r r r r r r r r r r
O O
O
r r
O*
r
O
r r
O
r r
r r
O
O*
r
O
O*
r
O*
r
r r r
O
r r
r r
O O O
r
r r
WARMING DRAWER
OVEN LIGHT
 
     
                
February 2006 9 16026930
© 2006 Maytag Services
Page 10
Control Testing Procedures
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
"Quick Test" Mode for EOC III
Follow the procedure below to perform the EOC III quick test. Once the control is in the quick test mode, any relay may be activated in any sequence. The test mode will be exited after 10 minutes of inactivity (no pads pressed within 10 minutes).
1. Press the Setup pad, then press the right ATM pad.
2. Press the left ATM pad, then press and hold Back and Enter pads for 5 seconds to enter SERVICE menu options.
3. Press the right ATM pad to scroll to the TEST menu.
4. Press the left ATM pad to select TEST options.
5. Press the left ATM pad again to enter the "Quick Test" mode.
6. Press each of the following pads indicated in the table below.
7. Press Cancel or Setup pads to exit. NOTE: Press and hold the applicable pad to activate the associated response.
Release the applicable pad to deactivate the associated response.
The control automatically enters the engineering mode so visual feedback of relay operations is available on the control display. Any time a load is activated, the cooling fan is activated. When the load is deactivated, the cooling fan is also deactivated.
Display will indicate the following:
Pad Response
BAKE....................................................Bake relay activated.
BROIL ..................................................Broil relay activated.
CONVECT............................................Convection Bake and Cooling Fan relays activated.
OVEN LIGHT .......................................Oven light relay activated.
RAPID PREHEAT ................................Convection Fan (HIGH/LOW) activated.
WARMING ZONE ................................Warming Zone relay activated.
VENT (DOWNDRAFT) FAN ................Vent Fan relay activated.
CLEAN .................................................Motorized Door Lock relay activated.
SETUP .................................................1 Second Beep.
FAN ......................................................Downdraft Fan (HIGH/LOW) relay activated.
WARMING DRAWER ..........................Warming Drawer (HIGH/LOW) relay activated.
Sensor Type: RTD 1000W platinum Calibration: 1654 (350° F/177° C) Temperature F (C)
300 (149) 1553 350 (177) 1654 400 (204) 1753 500 (260) 1949 600 (316) 2142 700 (371) 2331 800 (427) 2516 900 (483) 2697
1000 (538) 2874
OVEN SENSOR
Resistance (Ohms)
100 (38) 1143 200 (94) 1350
MEAT PROBE Type: NTC Thermistor Calibration: 9938 (150° F/65.5° C) Temperature F (C)
32 (0) 163300 68 (20) 62450 95 (35) 32660
122 (50) 18020 158 (70) 8760 185 (85) 5360
212 (100) 3400
Resistance (Ohms)
16026930 10 February 2006
© 2006 Maytag Services
Page 11
Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Description of Fault Codes for EOC III
Each fault code consists of 4 digits and is structured as follows:
1st (Leftmost) Digit:
Primary Failure System 1 – Local to Control System d – Diagnostic Failure (measurable) 3 – Sensor or Meat Probe c – Control-Related Error (not measurable) 4 – Input to Control System 9 – Door Lock
If a fault is detected, then one of the following three messages will be scrolled on the display:
FAULT DETECTED PRESS ENTER TO TRY AGAIN. This message displays when a fault is detected while a cooking function is active. Clear by pressing the Cancel keypad.
FEATURE NOT AVAILABLE. This message displays when a fault is detected while entering data during initial
programming and also when a locked out function is detected. Clear by pressing any key.
FAULT DETECTED DISABLE POWER TO CLEAR. This message displays when a runaway temperature condition
is detected while the control is in idle mode. Press any key to clear the message, but the fault remains until the control senses a Power-On reset.
Fault Code
1c1c Shorted key.
1c2c Membrane keyboard disconnected.
1c4c Board – to – Board communication failure. Replace control. 1c6c EEPROM hardware fault. Replace control. 1c7c Control not calibrated. Replace control. 1c8c EEPROM CRC error – User Options. Replace control. 1c81 EEPROM CRC error – Cook Profile. Replace control.
1d11 Unlocked runaway temperature – 600°
1d21 Locked runaway temperature – 950°
3d11 Temperature sensor open.
3d21 Temperature sensor shorted.
3d41 Meat probe shorted.
3d51 Meat probe not calibrated.
4d11 Door switch not closed when locked. Check connections, switch, harness, and motor. If OK, replace control. 4d21 No cooling fan rotation. Check cooling fan motor and harness. If OK, replace control. 4d31 Cooling fan on when de-energized. Check cooling fan motor and harness. If OK, replace control. 4d41 Cooling fan overspeed. Check cooling fan motor and harness. If OK, replace control. 4d51 Door switch circuit fault. Check connections, harness, and motor. If OK, replace control. 9d11 Latch will not lock. Check wire connections. If OK, replace motorized door lock. 9d21 Latch will not unlock. Check wire connections. If OK, replace motorized door lock. 9d31 Latch both locked and unlocked. Check wire connections. If OK, replace motorized door lock.
Description Component to Troubleshoot/Replace
2nd Digit: Alpha-Character 3rd Digit: Secondary
Failure Mechanism
Ensure ribbon cable is securely connected, inspect ribbon cable and connector (shorts, breakage, corrosion, etc.). If OK, replace control. Ensure ribbon cable is securely connected, inspect ribbon cable and connector (shorts, breakage, corrosion, etc.). If OK, replace control.
Ohm sensor and harness (see "Oven Sensor" chart). If OK, change control. Ohm sensor and harness (see "Oven Sensor" chart). If OK, change control. Check connections, sensor (see "Oven Sensor" chart) and harness. If OK, replace control. Check connections, sensor (see "Oven Sensor" chart) and harness. If OK, replace control. Check probe jack and harness. If OK, check meat probe (see "Meat Probe" chart). Check probe jack and harness. If OK, check meat probe (see "Meat Probe" chart).
4th Digit : Oven
Cavity Number 1 – Upper (Single) Oven 2 – Lower Oven c – Control System
February 2006 11 16026930
© 2006 Maytag Services
Page 12
Control Testing Procedures
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
Gas Conversion: JDS986*BD*
Pressure Regulator Conversion
1. Remove cap and force plastic plunger from bottom of cap.
2. Turn plunger over and force back into original location.
NOTE: Plunger must snap into position and the type of
gas being supplied (NAT or LP) must be visible on lower side of plunger.
JDS986*BD* Pressure Regulator Conversion
WARNING
Natural
LP
Gas Conversion: JDS8850BD*
Pressure Regulator Conversion
1. Remove plastic dust cover from cap nut (top of regulator) and remove cap nut.
2. Remove plastic dust cover from cap nut and reinstall on opposite side of cap nut.
3. Reinstall cap nut into regulator, replace dust cover.
NOTE: The marking for the type of gas being supplied
(NAT or LP) must be visible in top of cap nut.
Natural
LP
JDS8850BD* Pressure Regulator Conversion
Orifice Conversion:
1. Remove grates, burner caps, screws and burner heads (and grill, on models JDS986*BD*).
2. Converting one burner at a time, remove existing orifice hoods and install new orifice hood (see chart
below), screw down tight. Do not over tighten.
3. Replace grates, burner caps, screws and burner heads (and grill, on models JDS986*BD*).
Low Flame Adjustment:
1. Adjusting one burner at a time, turn burner control knob to lowest position and remove knob.
2. Insert screwdriver into knob stem to engage adjustment screw and adjust flame height (no blue lifting or yellow flame).
3. Replace burner control knob.
RF RR
GRILL
Natural LP
1.95 mm Red (1.14 mm)
Green (1.07 mm) Blue (.69 mm)
Green (1.07 mm) .033 mm
Orifice Conversion:
1. Remove burner grates, caps, screws and heads.
2. Converting one burner at a time, remove existing orifice hoods and install new orifice hood (see chart
below), screw down tight. Do not over tighten.
3. Replace burner grates, caps, screws and heads.
Low Flame Adjustment:
1. Adjusting one burner at a time, turn burner control knob to lowest position and remove knob.
2. Insert screwdriver into knob stem to engage adjustment screw and adjust flame height (no blue lifting or yellow flame).
3. Replace burner control knob.
NOTE: Drop in LP CHOKE after replacing burner heads
and screws, but before replacing caps and grates.
RF RR LR
LF Inner
Natural LP
1.95 mm Red (1.14 mm)
Green (1.07 mm) Blue (.64 mm)
1.42 mm .91 mm
.78 mm White (.55 mm)
16026930 12 February 2006
LF Outer
1.86 mm
Orange (.97 mm)
and Choke
© 2006 Maytag Services
Page 13
Wiring Diagram and Schematic
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
February 2006 13 16026930
© 2006 Maytag Services
JDS8850BD* Wiring Diagram
Page 14
Wiring Diagram and Schematic
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
16026930 14 February 2006
JDS8850BD* Control Circuits
© 2006 Maytag Services
Page 15
Wiring Diagram and Schematic
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
February 2006 15 16026930
© 2006 Maytag Services
JDS9860BD*, JDS9865BD* Wiring Diagram
Page 16
Wiring Diagram and Schematic
!
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, unless testing requires power and/or gas.
WARNING
JDS9860BD*, JDS9865BD* Control Circuits
16026930 16 February 2006
© 2006 Maytag Services