Maytag HV303 Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Ventilation System:
HV303
2"
1 3/4"
Side View
(not to scale)
Cooktop overlap 1/2"
• Dimensions (Actual Size) •
Vent overall depth:
Vent overall width:
Vent cutout depth:
Vent cutout width:
Vent height below countertop:
1 3/4" 30" see pg. 2 26 7/8" 25 1/4"
7 1/2"
2"
7 1/2"
• Additional Information •
• Follow the cooktop manufacturer's instructions
regarding minimum safe clearances and installation location. Failure to do so may result in a fire or safety hazard.
• Maximum duct length: add the straight duct
conversions (see page 4) of the fittings used to the amount of straight duct used. The total must be less than: 40 ft. if you use 3 1/4" x 10" duct; 40 ft. if you use 7" round duct. Plan duct system as short and straight as possible.
• Do not exhaust more than one vent into single duct
run. Do not vent exhaust air into a wall ceiling or concealed space of the building
• Thermal breaks, such as a short section of
non-metallic duct, should be used in areas of extreme cold. A back draft damper at the duct outlet may also be necessary.
• If the kitchen is sealed tightly or the air exhausted
cannot be replaced. A make-up air source must be available.
• Designed for installation into standard U.S. made
base cabinets.
• Electrical requirement: 120VAC, 60Hz. Locate house
junction box relative to the power supply leads on the blower.
• If there is a backsplash with a curved base at the
countertop level, then the clearance behind the vent will be reduced. Keep this in mind to avoid interference.
Cutout vent depth: 1 3/4" Vent lid depth: 2" Cooktop overlap: 1/2" Vent intake depth below cooktop: 2" Depth below cooktop including blower: 7 1/2" Distance from countertop to blower: 7 1/2"
(not to scale)
Cutout width
Blower
Wall View
Vent intake
30"
26 7/8"
Blower
See page 2-3 for more additional information
(Rotates 90° right
25 1/4"
or left from this
position)
Power supply leads
(rotates with blower)
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
234
Cabinet floor
Exhaust (rotates with blower)
BN276 • A234B287C150D123 • • 032603 • 95655 • 84637
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
•If your cabinet differs from the standard 24" deep, 36" high cabinets
shown on the following pages, then adjust your cutout locations accordingly to prevent interference.
• Access from the front of the cabinet to the underside of the cooktop,
the vent system, and the junction box must be provided for inspection and service. Any drawers or shelves placed below the cooktop and in front of the vent must be easy to remove for access to the cooktop, vent and junction box.
• When installing the cooktop and vent into a laminated or synthetic
countertop, follow the countertop manufacturer's instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
• Requires 3 1/4" x 10" duct. For maximum performance, it is
recommended that this duct be transitioned to 7" round as soon as possible. The blower may be directed down, left, right or through the back. (see page 3)
• Duct cutout may move up to 1 1/2" to left or right.
For installation with a different brand cooktop:
• Provide an opening in the countertop with a width equal to whichever
is greater, the vent cutout or the manufacturer's recommended cooktop cutout width.
• If the cutout width required for the cooktop exceeds the vent cutout
width by one (1) inch or more, then use a notched cutout. The notched cutout should use the vent cutout width in the rear portion of the cutout and the cooktop cutout width in the front portion.
• Provide a minimum flat countertop width equal to whichever is
greater, the vent overall width or the cooktop overall width.
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Ventilation System:
HV303
• Provide a cutout depth and minimum flat countertop DEPTH as follows:
Cutout depth = Cooktop cutout depth + Rear overhang of cooktop + 1 3/4"
Total overall depth = Cooktop overall depth + 2"
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
BN276 • A234B287C150D123 • • 032603 • 95655 • 84637
287