Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and
others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important
that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to
potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death.
DANGER indicates an imminently
DANGER
WARNING
CAUTION
hazardous situation which, if not avoided,
could result in death or injury.
WARNING indicates a potentially hazardous
situation which, if not avoided, could result
in death or injury.
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury.
CAUTION used without the safety alert
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and
how to avoid the risk of injury.
symbol indicates a potentially hazardous
situation which, if not avoided, could result
in property damage.
IMPORT ANT DEFINITIONS
• Maytag Customer Service Center: The Maytag Customer Service Center has the equivalent to a licensed tradesman in the
fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the Natural
Gas and Propane Installation Code as it relates to the installation of gas fired water heaters. The Service Specialist also has a
thorough understanding of this instruction manual, and is able to perform repairs strictly in accordance with the service guidelines
provided by the manufacturer.
• Gas Supplier: The natural gas or propane utility or service which supplies gas for utilization by the gas burning appliances within
this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including
the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances
within the building.
2
Page 3
SAFETY PRECAUTIONS
3
Page 4
TABLE OF CONTENTS
SAFE INSTALLATION, USE AND SERVICE ................................................................................................ 2
PREPARATIONS FOR INSTALLATION........................................................................................................ 7
Removing the Old Water Heater............................................................................................................................. 7
Get to Know Your Water Heater.............................................................................................................................. 8
Mixing V alve Usage ................................................................................................................................................ 9
LOCATING AND INSTALLING THE NEW HEATER...............................................................................10-18
Facts to Consider About the Location .............................................................................................................. 10,11
Located in Unconfined Spaces ............................................................................................................................. 12
Combustion Air and V entilation for Appliances
Located in Confined Spaces ............................................................................................................................ 12,13
Water Piping....................................................................................................................................................13,14
Temperature Pressure Relief Valve ................................................................................................................. 14,15
Filling the Water Heater ................................................................................................................................... 15,16
Gas Piping ....................................................................................................................................................... 17,18
Temperature Regulation ....................................................................................................................................... 21
SERVICE AND MAINTENANCE............................................................................................................. 22-24
Tank (Sediment) Cleaning .................................................................................................................................... 22
Vent System Inspection ........................................................................................................................................ 22
Anode Rod Inspection .......................................................................................................................................... 23
Start Up Conditions.......................................................................................................................................... 24,25
Smelly Water ............................................................................................................................................... 25
“AIR” In Hot Water Faucets.......................................................................................................................... 25
High Temperature Shut Off System ........................................................................................................ 25,26
Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble free
service. It is strongly suggested that this new water heater be
professionally installed, contact Maytag Customer Service (1-
800-788-8899) for recommended installers.
Abbreviations Found In This Instruction Manual:
•UL - Underwriters Laboratories Inc.
•EPACT - Energy Policy Act
•CAN - Canada
•CSA - Canadian Standards Association
•NFPA - National Fire Protection Association
•ANSI - American National Standards Institute
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturer’s Association
This gas-fired water heater is design certified by Underwriters
Laboratories Inc. under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.3 • CSA 4.3
(current edition). The installation must conform with CAN/CSA B149.1, installation codes and/or Local Installation Codes.
• Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation, operation,
and maintenance of the gas-fired water heater. It also contains
warnings through out the manual that you must read and be
aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since
we cannot put everything on the first few pages, READ THE
ENTIRE MANUAL BEFORE A TTEMPTING TO INST ALL OR
OPERATE THE WATER HEATER.
• The installation must conform with these instructions and local
code authority having jurisdiction. In the absence of local
codes, installations shall comply with the Natural Gas and
Propane Installation Code CAN/CSA - B149.1. This publication
is available from the Canadian Standards Association, 5060
Spectrum Wa y , Suite 100, Mississauga, Ontario, Canada L4W
5N6.
• If after reading this manual you have any questions or do not
understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
• Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires, see
Figures 9 through 14.
Examine the location to ensure the water heater complies
with the Locating and Installing the New Water Heater
section in this manual.
PRODUCT SPECIFICATIONS
TANKRECOVERYMINIMUMDIMENSIONS
CAPACITYTYPERATE GALS.VENT PIPEDIAMETER IN INCHES (mm)
IN GALSOFBTUPER HOURINCHESINCHES HEIGHT TOP OF
MODEL NUMBER (LTRS)GASRATE@ 90°F RISE(mm)(mm)DRAFT HOOD
* Adding suffix “D” denotes high altitude (Example: HRX75XQRSCGAD). High altitude models have a B.TU./ Recovery Rate 10% less than shown.
5
Page 6
ACCESSORIES AND TOOLS NEEDED
Accessories
T o simplify the inst allation Maytag has available the installation p art s shown below. You may or may not need all of these accessories
depending on your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS
AVAILABLE IN 2 GALLON (7.6 LITERS), Part No. 66001013 AND
5 GALLON (18.9 LITERS), Part No. 66001014 CAPACITY.
Tools
You may or may not need all these tools, depending on your
type of installation. These tools can be purchased at your local
hardware store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Teflon Tape
DRILL
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
TIN SNIPS
DRAIN PANS AVAILABLE IN 22” (559 mm) DIAMETER (PART NO.
66001011) FOR WATER HEATERS HAVING A DIAMETER 20” (508
mm) OR LESS, 24” (610mm) DIAMETER (PART NO. 66001105) FOR
WATER HEATERS HAVING A DIAMETER 22” (559 mm) OR LESS
AND 28” (711 mm) DIAMETER (PART NO. 66001012) FOR WATER
HEATERS HAVING A DIAMETER 26” (660 mm) OR LESS.
Additional T ools Needed
When Sweat Soldering
• Tubing Cutters or Hacksaw
• Propane Tank
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
PROPANE
TUBING CUTTER
TORCH
ROLL OF TEFLON
TAPE (USE ONLY ON
WATER HEATER
CONNECTIONS)
GARDEN HOSE
6 FOOT TAP E
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WATER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
6
HACKSAW
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
ROLL OF
SOLDER
FLUX
Page 7
PREPARA TIONS FOR INSTALLA TION
Removing the Old Water Heater
FIGURE 1.
4. Attach a hose to the water heater
drain valve and put the other end
in a floor drain or outdoors. Open
the water heater drain valve. Open
a nearby hot water faucet which
will relieve pressure in the water
heater and speed draining. The
water passing out of the drain
valve may be extremely hot. To
avoid being scalded, make sure all
connections are tight and that the
water flow is directed away from
any person, see Figures 1 and 4.
5. Disconnect the vent pipe from the draft hood where they
connect to the water heater. In most installations the vent
pipe can be lifted off af ter any screw or other attached devices
are removed. Dispose of the draft hood. The new water
heater has the draft hood which must be used for proper
operation.
6. If you have copper piping to the water heater, the two copper
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater.
This will avoid cutting off pipes too short. Additional cuts can
be made later if necessary. Disconnect the temperaturepressure relief valve drain line. When the water heater is
drained, disconnect the hose from the drain valve. Close the
drain valve. The water heater is now completely disconnected
and ready to be removed, see Figure 5.
FIGURE 4.
1. Turn “OFF” the gas supply to the
water heater.
If the main gas line Shut-off valve
serving all gas appliances is used,
also shut “OFF” the gas at each
appliance. Leave all gas
appliances shut “OFF” until the
water heater installation is
completed, see Figures 1 and 2.
2. Turn “OFF” the water supply to the
water heater at the water shut-off
valve or water meter. Some
installations require that the water
be turned off to the entire house,
see Figures 1 and 3.
3. Check again to make sure the gas supply is “OFF” to the
water heater . Then disconnect the gas supply connection from
the gas control valve.
FIGURE 2.
FIGURE 3.
FIGURE 5.
If you have galvanized pipe to the water heater, loosen the
two galvanized pipes with a pipe wrench at the union in each
line. Also disconnect the piping remaining to the water
heater. These pieces should be saved since they may be
needed when reconnecting the new water heater.
Disconnect the temperature-pressure relief valve drain line.
When the water heater is drained, disconnect the hose from
the drain valve. Close the drain valve. The water heater is
now completely disconnected and ready to be removed.
Mineral buildup or sediment may have accumulated in the
old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining, see Figure 6.
7
FIGURE 6.
Page 8
TYPICAL INST ALLATION
GET TO KNOW YOUR WATER HEA TER - GAS MODELS
AVent Pipe
BDraft Hood
CAnode
DHot Water Outlet
EOutlet
FWater Connections
GGas Supply
HManual Gas Shut-off Valve
SFlue Baffle(s)
TThermostat
UDrain Valve
VPilot and Main Burner
WFlue
XDrain Pan
YThermostat Shield (optional)
(T) THERMOST AT
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
** CLOSED WATER SYSTEMS ARE THOSE WITH
BACK FLOW PREVENTION DEVICES INSTALLED
IN THE INLET WATER SERVICE LINE.
Y
THERMOSTAT
SHIELD
(OPTIONAL)
FIGURE 7.
(V) PILOT & MAIN BURNER- NATURAL GAS
(V) PILOT & MAIN BURNER - PROPANE GAS
THERMOCOUPLE
PILOT
BURNER
8
MAIN
BURNER
Page 9
TYPICAL INSTALLATION
MIXING V ALVE USAGE
FIGURE 8.
This appliance has been design certified as complying with
American National St andard/CSA S tandard for water heaters and
is considered suitable for:
Water (Potable) Heating: All models are considered suitable
for water (potable) heating.
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water . Water heated
to a temperature which will satisfy clothes washing, dish
washing, and other sanitizing needs can scald and permanently
injure you upon contact. Some people are more likely to be
permanently injured by hot water than others. These include
the elderly, children, the infirm, or physically/mentally
handicapped. If anyone using hot water in your home fits into
one of these groups or if there is a local code or province law
requiring a certain temperature water at the hot water tap, then
you must take special precautions. In addition to using the
lowest possible temperature setting that satisfies your hot water
needs, a means such as a *Mixing Valve, shall be used at the
hot water taps used by these people or at the water heater.
Mixing valves are available at a plumbing supply distributor,
see Figure 8. Valves for reducing point of use, temperature by
mixing cold and hot water are also available. Consult MaytagCustomer Service at 1-800-788-8899. Follow mixing valve
manufacturer’s instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
“Temperature Regulation” section in this manual, see Figures
22 and 23 on page 21.
9
Page 10
LOCATING AND INSTALLING THE NEW WATER HEATER
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater,
because the placement is a very important consideration for the
safety of the occupants in the building and for the most
economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed:
• Select a location indoors as close as practical to the gas vent
or chimney to which the water heater vent is going to be
connected, and as centralized with the water piping system
as possible.
• Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
water pipes connected to the water heater.
• Devices that will turn off the gas supply to a gas water heater
while at the same time shutting off its water supply.
Installation of the water heater must be accomplished in such a
manner that if the tank or any connections should leak, the flow
will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are
available at your local distributor. Such a drain pan must have a
minimum length and width of at least 2 inches (51 mm) greater
than the water heater dimensions and must be piped to an
adequate drain. The pan must not restrict combustion air flow.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a drain pan piped
to a drain. However, unanticipated damage can be reduced or
prevented by a leak detector or water shut-off device used in
conjunction with a piped drain pan. These devices are available
from some plumbing supply wholesalers and retailers, and detect
and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm or
turn off the incoming water to the water heater when leakage
is detected.
• Sensors mounted in the drain pan that turn off the water
supply to the entire home when water is detected in the
drain pan.
INST ALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP or
butane, etc.] and other substances such as adhesives, etc.) emit
flammable vapors which can be ignited by a gas water heater’s
pilot light or main burner. The resulting flashback and fire can
cause death or serious burns to anyone in the area, as well as
property damage. If installation in such areas is your only option,
then installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor at least
18 inches. While this may reduce the chances of flammable
vapors, from a floor spill being ignited, gasoline and other
flammable substances should never be stored or used in the
same room or area containing a gas water heater or other open
flame or spark producing appliance. NOTE: Flammable vapors
may be drawn by air currents from other areas of the structure to
the appliance.
• Water supply shut-off devices that activate based on the
water pressure differential between the cold water and hot
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
10
Page 11
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2 mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor
must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
A gas water heater cannot operate properly without the correct
amount of air for combustion. Do not install in a confined area
such as a closet, unless you provide air as shown in the Locatingand Installing The New Water Heater section. Never obstruct
the flow of ventilation air. If you have any doubts or questions at
all, call your gas supplier. Failure to provide the proper amount
of combustion air can result in a fire or explosion and cause
death, serious bodily injury, or property damage.
FIGURE 10.
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or water
heaters be installed so that combustion and ventilation air be
taken from outside these areas.
Minimum clearances between the water heater and combustible
construction are 0 inch at the sides and rear, 4 inches (102 mm)
at the front, and 6 inches (153 mm) from the vent pipe. Clearance
from the top of the jacket is 12 inches (305 mm) on most models.
Note that a lesser dimension may be allowed on some models,
refer to the label attached adjacent to the gas control valve on
the water heater, see Figure 9.
FIGURE 9.
Propellants of aerosol sprays and volatile compounds, (cleaners,
chlorine based chemicals, refrigerants, etc.) in addition to being
highly flammable in many cases, will also change to corrosive
hydrochloric acid when exposed to the combustion products of
the water heater. The results can be hazardous, and also cause
product failure.
Insulation Blankets
Insulation blankets available to the general public for external
use on gas water heaters are not necessary with Maytag
products. The purpose of an insulation blanket is to reduce the
standby heat loss encountered with storage tank heaters. Your
Maytag water heater meets or exceeds the NRCan standards
with respect to insulation and standby loss requirements, making
an insulation blanket unnecessary.
WARNING
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions (See Figure 7 for
identification of components mentioned below). Failure to follow
these instructions can restrict the air flow required for proper
11
Page 12
combustion, potentially resulting in fire, asphyxiation, serious
personal injury or death.
• Do not apply insulation to the top of the water heater, as this
will interfere with safe operation of the draft hood.
• Do not cover the outer door, thermostat or temperature &
pressure relief valve.
• Do not allow insulation to come within 2” (50.8 mm) of the
floor to prevent blockage of combustion air flow to the burner.
commence within 12 inches (30 cm) of the top and one
commencing within 12 inches (30 cm) of the bottom of the
enclosures.
• Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
• Do obtain new warning and instruction labels from Maytag
for placement on the blanket directly over the existing labels.
• Do inspect the insulation blanket frequently to make certain
it does not sag, thereby obstructing combustion air flow.
Combustion Air and Ventilation for
Appliances Located in Unconfined Spaces
UNCONFINED SP ACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m
aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the
appliances are installed, through openings not furnished with
doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate
to provide air for combustion, ventilation and dilution of flue
gases. However, in buildings of tight construction (for example,
weather stripping, heavily insulated, caulked, vapor barrier , etc.),
additional air may need to be provided using the methods
described in Combustion Air and Ventilation for AppliancesLocated in Confined Spaces.
3
per kW) of the
FIGURE 11.
B. ALL AIR FROM OUTDOORS: (See Figures 12, 13 and 14)
The confined space shall be provided with two permanent
openings, one commencing within 12 inches (30 cm) of the top
and one commencing within 12 inches (30 cm) from the bottom
of the enclosure. The openings shall communicate directly, or
by ducts, with the outdoors or spaces (crawl or attic) that freely
communicate with the outdoors.
Combustion Air and Ventilation for
Appliances Located in Confined Spaces
CONFINED SPACE is a space whose volume is less than
50 cubic feet per 1,000 Btu per hour (4.8 m
aggregate input rating of all appliances installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figures 10 and 11)
The confined space shall be provided with two permanent
openings communicating directly with an additional room(s)
of sufficient volume so that the combined volume of all spaces
meets the criteria for an unconfined space. The total input of
all gas utilization equipment installed in the combined space
shall be considered in making this determination. Each
opening shall have a minimum free area of one square inch
per 1,000 Btu per hour (22 cm
2
/kW) of the total input rating of
all gas utilization equipment in the confined space, but not
less than 100 square inches (645 cm
3
per kW) of the
2
). One opening shall
FIGURE 12.
• When directly communicating with the outdoors, each opening
shall have a minimum free area of 1 square inch per 4,000 Btu per
hour (5.5 cm
2
/kW) of total input rating of all equipment in the
enclosure, see Figure 12.
• When communicating with the outdoors through vertical
ducts, each opening shall have a minimum free area of
1 square inch per 4,000 BTU per hour (5.5 cm
2
/kW) of total
input rating of all equipment in the enclosure, see
Figure 13.
12
Page 13
Water Piping
FIGURE 13.
• When communicating with the outdoors through horizontal
ducts, each opening shall have a minimum free area of
1 square inch per 2,000 BTU per hour (11 cm
2
/kW) of total
input rating of all equipment in the enclosure, see
Figure 14.
• When ducts are used, they shall be of the same crosssectional area as the free area of the openings to which they
connect. The minimum short side dimension of rectangular
air ducts shall not be less than 3 inches
(76.2 mm), see Figure 14.
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water
heated to a temperature which will satisfy clothes washing,
dish washing, cleaning and other sanitizing needs can scald
and permanently injure you upon contact. Some people are
more likely to be permanently injured by hot water than others.
These include the elderly, children, the infirm, or physically/
mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or
province law requiring a certain temperature water at the hot
water tap, then you must take special precautions. In addition
to using the lowest possible temperature setting that satisfies
your hot water needs, a means such as a *mixing valve, shall
be used at the hot water taps used by these people or at the
water heater. Mixing valves are available at a plumbing supply
distributor, see Figure 8 on p age 9 and Figure 15 below. V alves
for reducing point of use temperature by mixing cold and hot
water are also available. Consult Maytag Customer Serviceat 1-800-788-8899. Follow manufacturer’s instructions for
installation of the valves. Before changing the factory setting
on the thermostat, read the Temperature Regulation section
in this manual.
FIGURE 14.
• Louvers and Grilles: In calculating free area, consideration
shall be given to the blocking effect of louvers, grilles or
screens protecting openings. Screens used shall not be
smaller than 1/4 inch (6.4 mm) mesh. If the free area through
a design of louver or grille is known, it should be used in
calculating the size opening required to provide the free area
specified. If the design and free area is not known, it may be
assumed that wood louvers will be 20-25 percent free area
and metal louvers and grilles will have 60-75 percent free
area. Louvers and grilles shall be fixed in the open position
or interlocked with the equipment so that they are opened
automatically during equipment operation.
• Special Conditions Created by Mechanical Exhausting or
Fireplaces: operation of exhaust fans, ventilation systems,
clothes dryers or fireplaces may create conditions requiring
special attention to avoid unsatisfactory operation of installed
gas utilization equipment.
FIGURE 15.
This water heater shall not be connected to any heating systems
or component(s) used with a non-potable water heating
appliance.
13
Page 14
Toxic chemicals, such as those used for boiler treatment shall
not be introduced into this system.
Water supply systems may, because of such events as high
line pressure, frequent cut-offs, the effects of water hammer
among others, have installed devices such as pressure reducing
valves, check valves, back flow preventers, etc. to control these
types of problems. When these devices are not equipped with
an internal by-pass, and no other measures are taken, the
devices cause the water system to be closed. As water is heated,
it expands (thermal expansion) and closed systems do not allow
for the expansion of heated water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of the water heater’s temperature-pressure relief valve is
reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unaccept able
condition and must be corrected. It is recommended that any
devices installed which could create a closed system have a
by-pass and/or the system have an expansion tank to relieve
the pressure built by thermal expansion in the water system.
Refer to the Thermal Expansion section under Troubleshooting
Guide or contact local plumbing authority or call Maytag
Customer Service at 1-800-788-8899 for an authorized
installer on how to control this situation.
can be accomplished by insulating the hot water lines
from the water heater.
NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.
Figure 16 shows the typical attachment of the water piping to
the water heater. The water heater is equipped with 1” NPT
water connections for 75 gallon models.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the water connections. Do
not solder the water lines directly to the water connections
on the tank. It will harm the dip tube and damage the tank.
• Look at the top cover of the water heater. The water outlet is
marked “HOT”. Put two or three turns of teflon tape around
the exposed end of the 1” NPT threaded nipple. Connect the
hot water pipe to the hot water outlet on the water heater.
• Look at the top of the water heater. The cold water inlet is
marked “COLD”. Put two or three turns of teflon tape around
the exposed end of the 1” NPT threaded nipple. Connect the
cold water pipe to the cold water inlet of the water heater.
NOTE: This water heater is super insulated to minimize
heat loss from the tank. Further reduction in heat loss
FIGURE 16.
Temperature-Pressure Relief Valve
This heater is provided with a properly certified combination
temperature - pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing laboratory
that maintains periodic inspection of production of listed
equipment of materials as meeting the requirements for Relief
Valves for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4
and the code requirements of ASME.
14
Page 15
If replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as indicated in the above
paragraph.
The valve must be marked with a maximum set pressure not to
exceed the marked maximum working pressure of the water
heater (150 psi = 1,035 kPa) and a discharge capacity not less
than the water heater input rate as shown on the model rating
plate.
The Discharge Pipe:
For safe operation of the water heater, the relief valve must not
be removed from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly
into the fitting of the water heater designed for the relief valve.
Position the valve downward and provide tubing so that any
discharge will exit only within 6 inches (153 mm) above, or at
any distance below the structural floor. Be certain that no cont act
is made with any live electrical part. The discharge opening must
not be blocked or reduced in size under any circumstances.
Excessive length, over 30 feet (9.14 m), or use of more than
four elbows can cause restriction and reduce the discharge
capacity of the valve, see Figure 17.
No valve or other obstruction is to be placed between the relief
valve and the tank. Do not connect tubing directly to discharge
drain unless a 6 inch air gap is provided. To prevent bodily
injury, hazard to life, or property damage, the relief valve must
be allowed to discharge water in quantities should
circumstances demand. If the discharge pipe is not connected
to a drain or other suitable means, the water flow may cause
property damage.
• Shall not be smaller in size than the outlet pipe size of the
valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both
the temperature-pressure relief valve, and the discharge
pipe.
• Shall terminate at an adequate drain.
• Shall not have any valve between the relief valve and tank.
The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to ensure
that (1) no one is in front of or around the outlet of the
temperature-pressure relief valve discharge line, and (2) the
water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one.
Filling the Water Heater
FIGURE 17.
15
Page 16
Never use this water heater unless it is completely full of water.
T o prevent damage to the tank, the t ank must be filled with water .
Water must flow from the hot water faucet before turning “ON”
gas to the water heater.
To fill the water heater with water:
• Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is on the lower front of
the water heater.
• Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.
• To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the
water heater and the piping.
• Check all water piping and connections for leaks. Repair as
needed.
Venting
VENT DAMPERS - Any vent damper, whether it is operated
thermally or otherwise must be removed if its use inhibits proper
drafting of the water heater.
Thermally Operated Vent Dampers: This gas-fired water
heater has a thermal efficiency at or above 80% which may
produce a relatively low flue gas temperature. Such
temperatures may not be high enough to properly open thermally
operated vent dampers. This would cause spillage of the flue
gases and may cause carbon monoxide poisoning.
Vent dampers must bear evidence of certification as complying
with the current edition of the American National Standard
ANSI Z21.66/CGA 6.14, (covering electrically and mechanically
actuated vent dampers). Before installation of any vent damper ,
consult your Maytag Customer Service Center at 1-800-7888899 or the local gas supplier for further information.
T o insure proper venting of this gas-fired water heater, the correct
vent pipe diameter must be utilized. Any additions or deletions
of other gas appliances on a common vent with
this water heater may adversely affect the operation of the
water heater. Consult your Maytag Customer Service Center
at 1-800-788-8899 or gas supplier if any such changes are
planned.
For proper venting in certain installations, a larger diameter vent
pipe may be necessary. Consult your Maytag Customer
Service Center at 1-800-788-8899 or gas supplier to aid you
in determining the proper venting for your water heater from
the vent tables in the current edition of CAN/CSA - B149.1
Installation Code.
Periodically check the venting system for signs of obstruction or
deterioration and replace if needed.
The combustion and ventilation air flow must not be obstructed.
The water heater with draft hood installed must be connected to
a chimney or listed vent pipe system, which terminates to the
outdoors. Never operate the water heater unless it is vented to
the outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.
• For proper draft hood attachment, the draft hood legs may
be angled slightly inward.
• Place the draft hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a
tight fit. Secure draft hood with the supplied brackets.
• Place the vent pipe over the draft hood. With the vent pipe in
position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw,
see Figure 18.
Obstructed or deteriorated vent systems may present serious
health risk or asphyxiation.
FIGURE 18.
The vent pipe from the water heater must be no less than the
diameter of the draft hood outlet on the water heater and must
slope upward at least 1/4 inch per linear foot (21 mm per meter),
see Figure 19.
FIGURE 19.
16
Page 17
All vent gases must be completely vented to the outdoors of the
structure (dwelling). Install only the draft hood provided with the
new water heater and no other draft hood.
Vent pipes must be secured at each joint with sheet metal
screws.
There must be a minimum of 6 inches (153 mm) clearance
between single wall vent pipe and any combustible material.
Fill and seal any clearance between single wall vent pipe and
combustible material with mortar mix, cement, or other
noncombustible substance. For other than single wall, follow
vent pipe manufacturer’s clearance specifications. To insure a
tight fit of the vent pipe in a brick chimney , seal around the vent
pipe with mortar mix cement.
Make sure the gas supplied is the same type listed on the
model rating plate. The inlet gas pressure must not exceed
14 inch water column (2.6kPa) for natural and propane (L.P.)
gas. If the gas control valve is subjected to pressures exceeding
1/2 pound per square inch (3.5kPa), the damage to the gas
control valve could result in a fire or explosion from leaking
gas.
If the main gas line Shut-off serving all gas appliances is used,
also turn “OFF” the gas at each appliance. Leave all gas
appliances shut “OFF” until the water heater installation is
complete.
A gas line of sufficient size must be run to the water heater.
Consult the current edition of the CAN/CSA - B149.1 Inst allation
Codes and/or your gas supplier concerning pipe size.
There must be:
• A readily accessible manual shut off valve in the gas supply
line serving the water heater, and
• A drip leg (sediment trap) ahead of the gas control valve to
help prevent dirt and foreign materials from entering the gas
control valve.
• A flexible gas connector or a ground joint union between the
shut off valve and control valve to permit servicing of the unit.
Failure to have required clearances between vent piping and
combustible material will result in a fire hazard.
Be sure vent pipe is properly connected to prevent escape of
dangerous flue gases which could cause deadly asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur
if air for combustion contains certain chemical vapors. Spray
can propellants, cleaning solvents, refrigerator and air
conditioner refrigerants, swimming pool chemicals, calcium and
sodium chloride, waxes, bleach and process chemicals are
typical compounds which are potentially corrosive.
Gas Piping
Be sure to check all the gas piping for leaks before lighting the
water heater. Use a soapy water solution, not a match or open
flame. Rinse off soapy solution and wipe dry.
The minimum inlet gas pressure shown on the rating plate is
that which will permit firing at the rated input.
Standard Models are for installation up to 2,000 feet (610 m)
above sea level.
High Altitude models are for installation from 2,000 feet
(610 m) to 4,500 feet (1,370 m) above sea level.
If a standard model is installed above 2,000 feet (610 m) or high
altitude model is installed above 4,500 feet (1,370 m), the input
rating should be reduced at the rate of 4 percent for each 1000
feet (305 m) above sea level which requires replacement of the
burner orifice in accordance with CAN/CSA - B149.1. Contact
Maytag Customer Service Center at 1-800-788-8899 or your
local gas supplier or call for further information.
17
Page 18
Failure to replace the standard orifice with a high altitude orifice
when installed at elevations above 2,000 feet (610 m) or above
4,500 feet (1,370 m) for high altitude model could result in
improper and inefficient operation of the appliance, producing
carbon monoxide gas in excess of safe limits, which could result
in serious injury or death. Contact Maytag Customer Service
at 1-800-788-8899 or your local gas supplier for any specific
changes which may be required in your area.
Use pipe joint compound or teflon tape marked as being resistant
to the action of petroleum (Propane [L.P.]) gases.
The appliance and its gas connection must be leak tested before
placing the appliance in operation.
Contaminants in the gas lines may cause improper operation of
the gas control valve that may result in fire or explosion. Before
attaching the gas line be sure that all gas pipe is clean on the
inside. To trap any dirt or foreign material in the gas supply line,
a drip leg (sometimes called a sediment trap) must be
incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the Gas Piping section.
Refer to the current edition of CAN/CSA - B149.1 and/or Local
Installation Code.
A sediment trap shall be installed as close to the inlet of the
water heater as practical at the time of water heater installation.
The sediment trap shall be either a tee fitting with a capped
nipple in the bottom outlet or other device recognized as an
effective sediment trap. If a tee fitting is used, it shall be installed
in conformance with one of the methods of installation, shown
in Figures 20 and 21.
The appliance and its individual Shut-off valve shall be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/
2 pound per square inch (3.5kPa). It shall be isolated from the
gas supply piping system by closing its individual manual Shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 pound per
square inch (3.5kPa).
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods, shown
in Figures 20 and 21.
Sediment Traps
FIGURE 20. GAS PIPING WITH FLEXIBLE CONNECTOR.
18
FIGURE 21. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.
Page 19
OPERATING INSTRUCTIONS
19
Page 20
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED AT FAUCETS.
A.This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING: smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use
any phone in your building.
•Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
LIGHTING INSTRUCTIONS
FIGURE 1.
1. STOP! Read the safety information above on
this label.
2. Set the thermostat to the lowest setting by turning
thermostat dial fully clockwise
3. Push the gas control knob down slightly and turn
clockwise
NOTE: Gas control knob CANNOT be turned from "PILOT"
to "OFF" unless it is pushed down slightly . Do not force.
4. Remove the inner and outer doors located below and
behind the gas control unit.
5. Wait five (5) minutes to clear out any gas. If you then
smell gas STOP! Follow "B" in the safety information
above on this label. If you do not smell gas, go to the
next step.
6. Find Pilot. Follow metal tube from the bottom , right of
the gas control to the pilot burner. (Figure D).
7. Turn gas control knob counterclockwise
(Figure B).
8. Push gas control knob down all the way and hold it down.
Immediately light the pilot with a match. Continue to hold
to "OFF" (Figure A).
until it stops.
TOP VIEWFIGURE D.
to "PILOT"
•If you cannot reach your gas supplier, call the
fire department.
C. Use only your hand to push down or turn the gas
control knob. Never use tools. If the knob will not
push down or turn by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately contact a qualified installer or
service agency to replace a flooded water heater. Do
not attempt to repair the unit! It must be replaced!
the gas control knob down for about one (1) minute
after the pilot is lit. Release the gas control knob and it
will pop back up. Pilot should remain lit. If it goes out,
repeat Steps 3 through 8. It may take several minutes for
air to clear the lines, before the pilot will light.
•If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
•If the pilot will not stay lit after several tries, turn the
gas control knob to "OFF" (Figure A) andcall your
service technician or gas supplier.
9. Replace inner and outer burner doors.
10. At arm's length away, turn the gas control knob
counterclockwise
11. Set thermostat to desired setting (See Figure 1).
CAUTION: Hotter water increases the risk of
scald injury. Consult the instruction manual
before changing temperature.
to on (Figure C).
TO TURN OFF GAS T O APPLIANCE
1. Set the thermostat to lowest setting.
2. Push gas control knob down slightly and turn clockwise
to “OFF”. Do not force, see Figure A.
20
Page 21
Temperature Regulation
Short repeated heating cycles caused by small hot water uses
can cause temperatures at the point of use to exceed the
thermostat setting by up to 30°F (16.7°C). If you experience this
type of use you should consider using lower temperature settings
to reduce scald hazards.
Any water heater’s intended purpose is to heat water. Hot water
is needed for cleansing, cleaning, and sanitizing (bodies,
dishes, clothing). Untempered hot water can present a scald
hazard. Depending on the time element, and the people
involved (adults, children, elderly, infirm, etc.) scalding may
occur at different temperatures.
on the thermostat, read the Temperature Regulation section in
this manual, see Figures 22 and 23.
Never allow small children to use a hot water tap, or to draw
their own bath water. Never leave a child or handicapped person
unattended in a bathtub or shower.
NOTE: A water temperature range of 120°F-140°F (49°C-60°C)
is recommended by most dishwasher manufacturers.
The thermostat of this water heater has been factory set at its
lowest position (PILOT LIGHTING). It is adjustable and must
be reset to the desired temperature setting to reduce the risk of
scald injury. The mark (
) indicative of approximately 120°F
(49°C) is preferred starting point. Some local codes or provinces
have a requirement for a lower setting.
Turn the water temperature dial clockwise ( ) to decrease
the temperature, or counterclockwise ( ) to increase the
temperature.
Should overheating occur or the gas supply fail to shut off, turn
off the manual gas control valve to the appliance.
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing needs
can scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot water
than others. These include the elderly, children, the infirm, or
physically/mentally handicapped. If anyone using hot water in
your home fits into one of these groups or if there is a local code
or province law requiring a certain temperature water at the hot
water tap, then you must take special precautions. In addition
to using the lowest possible temperature setting that satisfies
your hot water needs, a means such as a mixing valve, shall be
used at the hot water taps used by these people or at the water
heater. Mixing valves are available at a plumbing supply
distributor, see Figure 8 on page 9 and Figure 15 on page 13.
V alves for reducing point of use temperature by mixing cold and
hot water are also available. Consult Maytag CustomerService at 1-800-788-8899. Follow manufacturer’s instructions
for installation of the valves. Before changing the factory setting
FIGURE 22.
TemperatureTime to Produce 2nd & 3rd
SettingsDegree Burns on Adult Skin
VERY HOT= approx. 160°F (71°C)
C = approx. 150°F (66°C)About 1-1/2 seconds
B = approx. 140°F (60°C)Less than 5 seconds
A = approx. 130°F (54°C)About 30 seconds
Sediment build-up on the tank bottom may create varying amount
of noise, if left in the tank will cause permanent tank failure. In
some water areas, sediment can be removed by draining off
approximately one gallon of water each month.
Vent System Inspection
Burner Inspection
Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a flooded
water heater will create dangerous conditions which can cause
DEATH, SERIOUS BODIL Y INJURY, OR PROPERTY DAMAGE.
Contact the Maytag dealer from whom the appliance was
purchased or call Maytag Customer Service at
1-800-788-8899 for an authorized servicer to replace a
flooded water heater. Do not attempt to repair the unit! It
must be replaced!
At least once a year a visual inspection should be made of the
main burner and pilot burner, see Figure 24.
Y ou should check for sooting. Soot is not normal and will imp air
proper combustion.
Soot build-up indicates a problem that requires correction before
further use. Turn “OFF” gas to water heater and
leave off until repairs are made, because failure to correct the
cause of the sooting can result in a fire causing death, serious
injury, or property damage.
NATURAL
At least once a year a visual inspection should be made of the
venting system. You should look for:
• Obstructions which could cause improper venting. The
combustion and ventilation air flow must not be obstructed.
• Damage or deterioration which could cause improper venting
or leakage of combustion products.
• Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape
of dangerous flue gases which could cause deadly
asphyxiation.
Obstructions and deteriorated vent systems may present serious
health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur
if air for combustion contains certain chemical vapors. Spray
can propellants, cleaning solvents, refrigerator and air
conditioner refrigerants, swimming pool chemicals, calcium and
sodium chloride, waxes, bleach and process chemicals are
typical compounds which are potentially corrosive.
If after inspection of the vent system you found sooting or
deterioration, something is wrong. Call Maytag Customer
Service at 1-800-788-8899 for an authorized servicer or your
local gas supplier to correct the problem and clean or
replace the flue and venting before resuming operation of
the water heater.
PROPANE
FIGURE 24.
Burner Cleaning
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise ( ) to the “OFF” position,
depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF”
unless knob is depressed slightly. DO NOT FORCE.
Loose deposits on or around the burner can be removed by
carefully using the hose of a vacuum cleaner inserted through
the access door of the water heater. If the Burner needs to be
22
Page 23
removed for additional cleaning, call Maytag Customer Service
at 1-800-788-8899 for an authorized servicer to remove
and clean the burner and correct the problem that required
the burner to be cleaned.
Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on a
regular basis.
T emperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually
operated at least once a year.
When checking the temperature-pressure relief valve operation,
make sure that (1) no one is in front of or around the outlet of
the temperature-pressure relief valve discharge line, and (2) that
the water discharge will not cause any property damage, as the
water may be extremely hot, see Figure 25.
INSTALLED IN SUIT ABLE AREA: To insure sufficient ventilation
and combustion air supply, proper clearances from the water
heater must be maintained. See Facts to Consider About theLocation section. Combustible materials such as clothing,
cleaning materials, or flammable liquids, etc. must not be
placed against or adjacent to the water heater which can cause
a fire.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most
hot water tanks are equipped with an anode rod. The submerged
rod sacrifices itself to protect the tank. Instead of corroding the
tank, water ions attack and eat away the anode rod. This does
not affect the water’s taste or color. The rod must be maintained
to keep the tank in operating condition.
FIGURE 25.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one.
If the temperature-pressure relief valve on the appliance weeps
or discharges periodically, this may be due to thermal expansion.
Y ou may have a check valve installed in the water line or a water
meter with a check valve. Consult Maytag Customer Service
at 1-800-788-8899 for further information. Do not plug the
temperature-pressure relief valve.
Draining
The water heater should be drained if being shut down during
freezing temperatures. Also periodic draining and cleaning of
sediment from the tank may be necessary.
Anode deterioration depends on water conductivity, not
necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/or
replaced more often than an anode rod that appears to be intact.
Replacement of a depleted anode rod can extend the life of
your water heater. Inspection should be conducted by a qualified
technician. At a minimum, the anode(s) should be checked
annually after the warranty period.
23
Page 24
• Turn the gas control knob to the “OFF” position.
• Remove the washer and put the new one in place.
• CLOSE the cold water inlet valve to the water heater.
• OPEN a nearby hot water faucet and leave open to allow for
draining.
• Connect a hose to the drain valve and terminate to an
adequate drain.
• OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and
drained for an extended period, the drain valve should
be left open with hose connected allowing water to
terminate to an adequate drain.
• CLOSE the drain valve.
• Follow instructions in the Filling The Water heater section.
• Follow the lighting instructions in the Lighting section to restart
the water heater.
Drain Valve Washer Replacement
(for selected models with plastic drain valves).
(See Figure 26)
NOTE: For ordering replacement washers, refer to the
“Repair Parts List” section of this manual.
• Screw the handle and cap assembly back into the drain
valve and retighten using a wrench. DO NOT OVER
TIGHTEN.
• Follow instructions in the Filling The Water Heater section.
• Check for leaks.
• Follow the lighting instructions in the Lighting section to restart
the water heater.
FIGURE 26.
Service
Before calling for repair service, read the Start Up Conditions
and Operational Conditions found in the T roubleshooting Guide
of this manual.
• Turn “OFF” gas supply to water heater.
• Follow “Draining” instructions.
• Turning counter clockwise (
the screw handle.
), remove the hex cap below
TROUBLESHOOTING
Start Up Conditions
Draft Hood Operation
Check draft hood operation by performing a worst case
depressurization of the building. With all doors and windows
closed, and with all air handling equipment and exhaust fans
operating, such as furnaces, clothes dryers, range hoods and
bathroom fans, a match flame should still be drawn into the draft
hood of the water heater with its burner firing. If the flame is not
drawn toward the draft hood, shut off the water heater and make
necessary air supply changes to correct.
Condensation
Whenever the water heater is filled with cold water, some
condensate will form while the burner is on. A water heater may
appear to be leaking when in fact the water is condensation.
This usually happens when:
• A new water heater is filled with cold water for the first time.
• Burning gas produces water vapor in water heaters,
particularly high efficiency models where flue temperatures
are lower.
If a condition persists or you are uncertain about the operation
of the water heater, let the Maytag Customer Service check it
out.
Call Maytag Customer Service at 1-800-788-8899 for an
authorized servicer.
• Large amounts of hot water are used in a short time and the
refill water in the tank is very cold.
Moisture from the products of combustion condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a “sizzling” or
“frying” noise.
Excessive condensation can cause pilot outage due to water
running down the flue tube onto the main burner and putting out
the pilot.
Because of the suddenness and amount of water, condensation
water may be diagnosed as a “tank leak”. After the water in
the tank warms up (about 1-2 hours), the condition should
disappear.
Do not assume the water heater is leaking until there has been
enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation. The
water heater must be sized properly to meet the family’s
demands for hot water including dishwashers, washing
machines and shower heads.
Excessive condensation may be noticed during the winter and
early spring months when incoming water temperatures are at
their lowest.
24
Page 25
Good venting is essential for a gas fired water heater to operate
properly as well as to carry away products of combustion and
water vapor.
Smoke / Odor
It is not uncommon to experience a small amount of smoke and
odor during the initial start-up. This is due to burning off of oil
from metal parts, and will disappear in a short while.
Thermal Expansion
water conditions will cause a reaction between this rod and the
water. The most common complaint associated with the anode
rod is one of a “rotten egg smell”. This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the result of four factors which must all be present for the odor
to develop:
• a concentration of sulfate in the supply water.
• little or no dissolved oxygen in the water.
• a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
• an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact Maytag Customer Service at
1-800-788-8899 for further information concerning an Anode
Replacement Kit and this Chlorination Treatment.
Water supply system may, because of such events as high line
pressure, frequent cut-offs, the effects of water hammer among
others, have installed devices such as pressure reducing valves,
check valves, back flow preventers, etc., to control these types
of problems. When these devices are not equipped with an
internal by-pass, and no other measures are taken, the devices
cause the water system to be closed. As water is heated, it
expands (thermal expansion) and closed systems do not allow
for the expansion of heated water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of water heater’s temperature-pressure relief valve is
reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unaccept able
condition and must be corrected.
It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an
expansion tank or device to relieve the pressure built by thermal
expansion in the water system. Thermal expansion tanks are
available for ordering through the Maytag Customer Service
Center (1-800-788-8899). Contact the local plumbing inspector ,
water supplier and/or call Maytag Customer Service at
1-800-788-8899 for assistance in controlling these
situations.
Strange Sounds
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner
area during heating and cooling periods and should be
considered normal. See Condensation section.
Operational Conditions
Smelly Water
In each water heater there is installed at least one anode rod
(see parts section) for corrosion protection of the tank. Certain
If the smelly water persists after the anode replacement and
chlorination treatment, we can only suggest that chlorination or
aeration of the water supply be considered to eliminate the water
problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
“AIR” In Hot Water Faucets
HYDROGEN GAS: Hydrogen gas can be produced in a hot water
system that has not been used for a long period of time (generally
two weeks or more). Hydrogen gas is extremely flammable and
explosive. To prevent the possibility of injury under these
conditions, we recommend the hot water faucet, located farthest
away, be opened for several minutes before any electrical
appliances which are connected to the hot water system are
used (such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound similar
to air escaping through the pipe as the hot water faucet is
opened. There must be no smoking or open flame near the
faucet at the time it is open.
High Temperature Shut-Off System
This water heater is equipped with an automatic gas Shut-off
system. This system works when high water temperatures
are present. The high temperature Shut-off is built into the
gas control valve. It is non-resettable. If the high temperature
shut-off activates, the gas control valve must be replaced. Turn
25
Page 26
“OFF” the entire gas supply to the water heater. Call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
Leakage Checkpoints
Read this manual first. Then before checking the water heater
make sure the gas supply has been turned “OFF”, and never
turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with
water. To prevent damage to the tank, the tank must be filled
with water. Water must flow from the hot water faucet before
turning “ON” gas to the water heater, see Figure 28.
at the time of start-up after installation and when incoming
water is cold.
I. Water in the water heater bottom or on the floor may be from
condensation, loose connections, or the relief valve.
DO NOT replace the water heater until a full inspection of all
possible water sources is made and necessary corrective
steps taken.
Leakage from other appliances, water lines, or ground seepage
should also be checked.
* To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet, follow
“Draining” instructions in the Service and Maintenance section
and then remove fitting. Put pipe dope or teflon tape on the
threads and replace. Then follow Filling the Water Heater
instructions in the Locating and Installing the New WaterHeater section.
A. Water at the draft hood is water vapor which has condensed
out of the combustion products. This is caused by a
problem in the vent. Call Maytag Customer Service at
1-800-788-8899 for an authorized servicer.
B. *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
C. *The anode rod fitting may be leaking.
D. Small amounts of water from the temperature-pressure relief
valve may be due to thermal expansion or high water pressure
in your area.
E. *The temperature-pressure relief valve may be leaking at the
tank fitting.
F . Water from a drain valve may be due to the valve being slightly
opened.
G. *The drain valve may be leaking at the tank fitting.
H. Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets form
and drip onto the burner or run on the floor. This is common
FIGURE 28.
26
Page 27
TROUBLESHOOTING GUIDE
These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag
Customer Service Center at 1-800-788-8899 for assistance.
ProblemCauseSolution
Improperly sealed, hot or cold supply connection,Tighten threaded connections.
WA TER LEAKS
LEAKING T&P VALVE
SMELLY WATER
PILOT WILL NOT LIGHTThermocouple malfunction.Replace pilot assembly and/or thermocouple.
relief valve, drain valve, or thermostat threads.
Leakage from other appliances or water lines.Inspect other appliances near water heater.
Condensation of flue products.Refer to CONDENSATION.
Thermal expansion in closed water system.Install thermal expansion tank (DO NOT plug T&P valve).
Improperly seated valve.Check relief valve for proper operation
(DO NOT plug T&P valve).
High sulfate or mineral content in water supply.Drain and flush heater thoroughly, then refill.
Bacteria in water supply.Chlorinate or aerate water supply.
Gas control knob not positioned correctly.Refer to LIGHTING INSTRUCTIONS.
Main gas supply off.Turn on main gas shut-off valve.
Match not close to pilot.Locate pilot, move match closer.
BURNER WILL NOT
STAY LIT
PILOT OUTAGEThermocouple malfunction.Replace pilot assembly and/or thermocouple.
NOT ENOUGHLow gas pressure.Contact your gas supplier.
HOT WATERIncoming water is unusually cold.Allow more time for heater to re-heat.
WATER TOO HOTThermostat set too high.Refer to TEMPERATURE REGULATION.
WATER HEATER SOUNDSCondensation dripping on burner.Refer to CONDENSATION.
SIZZLING - RUMBLING
SOOTING
VENT GAS ODORS
Thermocouple malfunction.Replace pilot assembly and/or thermocouple.
Defective Gas Control.Replace Gas Control.
Dirty pilot burner.Clean pilot assembly.
Thermocouple tip is not in contact with pilot flame.Insert thermocouple correctly.
Defective Gas Control.Replace Gas Control.
Heater not lit or thermostat not on.Refer to LIGHTING INSTRUCTIONS.
Thermostat set too low.Refer to TEMPERATURE REGULATION.
Heater undersized.Reduce hot water use.
Leaking hot water pipes or fixtures.Have plumber check and repair leaks.
High temperature limit switch activated.Contact a Maytag Customer Service Agent to
determine cause.
Sediment or calcium in bottom of heater tank.Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual.
Improper combustion.No adjustment available. Contact a Maytag Customer
Service Agent to determine cause.
Lack of supply air.
Improperly installed vent piping.Contact a Maytag Customer Service Agent to determine
Downdraft.cause.
Poor combustion.
27
Page 28
REPAIR P ARTS LIST
MA YTAG GAS WA TER HEATERS
MODEL NO’S
HRX75XQRS 75 Gallon Natural Gas
HRX75CQRS 75 Gallon Propane Gas
BURNER ASSEMBL Y
PROP ANE BURNER ASSEMBLY
18
4
3
Key Model Number
No. Part DescriptionHRX75XQRSHRX75CQRS
Now that you have purchased this gas water heater, should a need
ever exist for repair parts or service, simply call Maytag CustomerService at 1-800-788-8899 for an authorized servicer. Be sure to
provide all pertinent facts when you call or visit.
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST .
The model number of this gas water heater will be found on the
model rating plate located near the gas control valve.
When ordering repair parts, always give the following information:
• Model number
• Serial Number
28
• Part Description
• Part Number
Page 29
NOTES
29
Page 30
NOTES
30
Page 31
NOTES
31
Page 32
W ARRANTY
FULL ONE YEAR W ARRANTY
For one year from the date of original retail purchase, any part which fails in normal home use will be repaired
or replaced free of charge.
If a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be
replaced free of charge.
The warranty of the replacement is the balance of the original water heater’s warranty.
LIMITED PARTS WARRANTY
After the first year and through the tenth year from the date of original retail purchase, any parts which fail due
to a defect in materials or workmanship, will be replaced or repaired free of charge for the part itself, with the
owner paying all other costs, including labor, mileage and transportation.
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty
coverage for parts that are proved to be defective in material or workmanship is effective for one year from the
date of the original retail purchase.
The warranty of the replacement is the balance of the original water heater’s warranty, or twelve months from
the date of the part(s) purchase, whichever comes first.
This warranty is limited to the original owner of the water heater.
LIMITED T ANK W ARRANTY AGAINST LEAKS
After the first year and through the tenth year from the date of original retail purchase, if a leak occurs in the
tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge for
the water heater, with the owner paying all other costs, including labor, mileage and transportation.
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty
coverage for the tanks that are proved to be defective in material or workmanship is effective for two years from
the date of the original retail purchase.
The warranty of the replacement is the balance of the original water heater’s warranty.
Please note: The full and limited warranty applies only while this water heater is used in Canada.
This warranty is limited to the original owner of the water heater.
TO RECEIVE W ARRANTY SER VICE
To locate an authorized service company in your area contact the Maytag dealer from whom your appliance
was purchased; or call a Maytag Customer Service at the number listed below . Should you not receive satisfactory
warranty service, please call or write:
When contacting Maytag Customer Service be sure to provide the model and serial number of your appliance,
the name and address of the dealer from whom you purchased the appliance and the date of purchase.
MAYTAG WATER HEATERS ARE MANUFACTURED AND THIS WARRANTY IS PROVIDED BY STATE
INDUSTRIES, INC., ASHLAND CITY, TN. MAYTAG IS A TRADEMARK OF THE MAYTAG CORPORATION
AND IS USED UNDER LICENSE TO STATE INDUSTRIES, INC.
32
Page 33
Series Ten
GUIDE D’UTILISATION
DU CHAUFFE-EAU
AU GAZ
POUR LE CHAUFFAGE D’EAU POTABLE
SEULEMENT
NE CONVIENT PAS AU CHAUFFAGE
DE LOCAUX
NE CONVIENT PAS AUX MAISONS
PRÉFABRIQUÉES (MOBILES)
AVERTISSEMENT. Assurez-vous de bien suivre
les instructions données dans cette notice pour
réduire au minimum le risque d’incendie ou
d’explosion ou pour éviter tout dommage matériel,
toute blessure ou la mort.
Numéro du modèle
HRX75XQRSCGAHRX75CQRSCGA
– Ne pas entreposer ni utiliser d’essence ou ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
– QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ :
Ne pas tenter d’allumer d’appareil.
•
Ne touchez à aucun interrupteur; ne pas vous
•
servir des téléphones se trouvant dans le
bâtiment.
Appelez immédiatement votre fournisseur de
•
gaz depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur,
•
appelez le service des incendies.
– L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
IMPRIMÉ 0107197667-001
www.maytagwaterheaters.com
1
Pour votre sécurité
UN ODORISANT EST AJOUTÉ AU GAZ
QUI ALIMENTE LE CHAUFFE-EAU.
Page 34
INSTALLATION, UTILISATION ET ENTRETIEN SÉCURITAIRES
Il est important de veiller à la sécurité des personnes durant l’installation, l’utilisation et l’entretien du chauffe-eau.
De nombreux messages et des consignes de sécurité sont indiqués dans le présent manuel et inscrits sur le chauffe-eau.
Ils visent à mettre en garde les installateurs, utilisateurs et réparateurs du chauffe-eau contre les risques de blessures.
Lire attentivement et observer tous les messages et toutes les consignes de sécurité. Il est très important que chaque
message soit bien compris.
Symbole d’alerte de sécurité. Il indique des dangers potentiels
de blessures. Observer tous les messages qui accompagnent
ce symbole afin d’éliminer les risques de blessures graves ou
mortelles.
DANGER indique un danger imminent qui, s’il n’est
DANGER
AVERTISSEMENT
ATTENTION
pas évité, risque d’entraîner des blessures graves
ou mortelles.
AVERTISSEMENT indique un danger potentiel qui, s’il
n’est pas évité, risque d’entraîner des blessures
graves ou mortelles.
ATTENTION indique un danger potentiel qui, s’il
n’est pas évité, risque d’entraîner des blessures
mineures ou modérées.
Le mot ATTENTION utilisé sans le symbole d’alerte
ATTENTION
En général, les messages de sécurité indiquent le type de danger encouru si les consignes ne sont pas suivies et les moyens
d’éviter les accidents.
indique un danger potentiel qui, s’il n’est pas évité,
peut entraîner des dommages matériels.
DÉFINITIONS IMPORTANTES
• Service à la clientèle Maytag : Le personnel du service à la clientèle Maytag a des compétences équivalant à celles d’ouvriers
qualifiés dans les domaines de la plomberie, de l’adduction d’air, de la ventilation et de l’alimentation en gaz, ce qui comprend
une connaissance approfondie des exigences du Code d’installation du gaz naturel et du propane relatives à l’installation
des chauffe-eau au gaz. Le centre de service comprend en outre parfaitement le présent manuel d’instructions et est en
mesure d’effectuer des réparations conformément aux directives d’entretien du fabricant.
• Fournisseur de gaz : Entreprise ou service public de distribution de gaz naturel (ou de propane) fournissant le gaz destiné aux
appareils dont il est question dans le présent document. Il incombe généralement au fournisseur de gaz d’inspecter et
d’approuver la tuyauterie de gaz extérieure jusqu’au compteur, compteur compris, ou jusqu’au réservoir de propane du bâtiment.
Plusieurs fournisseurs de gaz offrent également des services d’inspection et d’entretien pour les appareils au gaz installés à
l’intérieur.
2
Page 35
MESURES DE SÉCURITÉ
3
Page 36
TABLE DES MATIÈRES
INSTALLATION, UTILISATION ET ENTRETIEN SÉCURITAIRES ..................................................................2
MESURES DE SÉCURITÉ ............................................................................................................................3
TABLE DES MATIÈRES................................................................................................................................. 4
RESPONSABILITÉ DU CLIENT .....................................................................................................................5
SPÉCIFICATIONS TECHNIQUES DU PRODUIT ..........................................................................................5
ACCESSOIRES ET OUTILS NÉCESSAIRES ............................................................................................... 6
PRÉPARATION À L’INSTALLATION .............................................................................................................. 7
Enlèvement de l’ancien chauffe-eau .......................................................................................................................... 7
INSTALLATION TYPE ................................................................................................................................. 8, 9
Description du chauffe-eau au gaz ............................................................................................................................ 8
Utilisation d’un robinet mélangeur ............................................................................................................................. 9
CHOIX DE L’EMPLACEMENT DU CHAUFFE-EAU ET INSTALLATION .................................................. 10-18
Points à considérer dans le choix de l’emplacement ........................................................................................ 10, 11
Tuyauterie de gaz ............................................................................................................................................. 17, 18
INSTRUCTIONS DE FONCTIONNEMENT ............................................................................................. 19-21
Instructions d’allumage et d’utilisation .............................................................................................................. 19, 20
Réglage de la température...................................................................................................................................... 21
ENTRETIEN ET RÉPARATION............................................................................................................... 22-24
Nettoyage du réservoir (dépôts) .............................................................................................................................. 22
Inspection du système de ventilation ...................................................................................................................... 22
Inspection du brûleur .............................................................................................................................................. 22
Nettoyage du brûleur .............................................................................................................................................. 22
Inspection de la tige d’anode .................................................................................................................................. 23
Fonctionnement de la soupape de décharge à sécurité thermique .......................................................................... 23
Remplacement de la rondelle du robinet de vidange................................................................................................ 24
Service ................................................................................................................................................................... 24
Fumée et odeur ............................................................................................................................................. 25
Conditions de fonctionnement ...........................................................................................................................25, 26
Présence d’air dans les robinets d’eau chaude ........................................................................................ 25, 26
Système d’arrêt automatique en cas de température excessive de l’eau ....................................................... 26
Points de vérification des fuites .............................................................................................................................. 26
GUIDE DE DÉPANNAGE ............................................................................................................................. 27
LISTE DES PIÈCES DE RECHANGE ......................................................................................................... 28
Merci d’avoir acheté un chauffe-eau Maytag. Dûment installé
et entretenu, il procurera des années de service sans ennui. Il
est vivement suggéré de faire installer le chauffe-eau par un
spécialiste. Pour obtenir le nom d’installateurs recommandés,
communiquer avec le service à la clientèle Maytag, au
1 800 788-8899.
Sigles utilisés dans le présent manuel
• UL – Underwriters Laboratories Inc.
• EPACT – Energy Policy A ct
• CAN – Canada
• CSA – Association canadienne de normalisation
• NFPA – National Fire Protection Association
• ANSI – American National Standards Institute
• ASME – American Society of Mechanical Engineers
• GAMA – Gas Appliance Manufacturer’s Association
De conception certifiée par Underwriters Laboratories Inc., le
chauffe-eau est conforme à la norme American National
Standard/CSA ANSI Z21.10.3 • CSA 4.3 visant les chauffe-eau
au gaz (édition courante). Son installation doit être conforme au
code CAN/CSA B149.1 ou aux codes d’installation locaux.
• Lire attentivement d’abord la section « Mesures de sécurité »
(page 3), puis le reste du manuel. Le défaut de suivre les
règles de sécurité peut entraîner le mauvais fonctionnement
du chauffe-eau et causer LA MORT, DES BLESSURES
GRAVES ET DES DÉGÂTS MATÉRIELS.
Le présent manuel contient des instructions pour
l’installation, l’utilisation et l’entretien du chauffe-eau. Il
contient aussi des messages d’avertissement qu’il faut lire
et garder à l’esprit. Tous les messages d’avertissement et
instructions sont essentiels à la sécurité des occupants et
au bon fonctionnement du chauffe-eau. Étant donné que
ces informations ne peuvent être exposées dans les
quelques premières pages du manuel, IL CONVIENT DE
LIRE LA TOTALITÉ DU MANUEL AVANT D’INSTALLER OU
D’UTILISER LE CHAUFFE-EAU.
• L’installation doit être conforme aux présentes directives et
aux codes réglementaires locaux. S’il n’existe pas de codes
locaux, l’installation doit satisfaire au Code d’installation
du gaz naturel et du propane, CAN/CSA B149.1. On peut se
procurer ce document auprès de l’Association canadienne
de normalisation, 5060 Spectrum Way, bureau 100,
Mississauga (Ontario), Canada L4W 5N6.
• Si des questions subsistent ou si certaines instructions
demeurent incomprises après la lecture du manuel, appeler
le service à la clientèle Maytag, au 1 800 788-8899, pour
obtenir le nom d’un agent de service agréé.
• Planifier soigneusement l’emplacement d’installation du
chauffe-eau. Pour éliminer les risques d’accidents mortels
et d’incendie causés par le monoxyde de carbone, il est très
important de bien installer les tuyaux d’évent, de manière à
assurer la combustion et la ventilation adéquates (fig. 9 à 14).
Inspecter l’emplacement pour s’assurer que le chauffe-eau
peut être installé suivant les indications de la section « Choix
de l’emplacement du chauffe-eau et installation ».
* Le suffixe « D » désigne les modèles haute altitude (p. ex., HRX75XQRSCGAD). La capacité nominale de récupération des modèles haute altitude
est de 10 % moindre que les valeurs indiquées ci-dessus.
5
Page 38
ACCESSOIRES ET OUTILS NÉCESSAIRES
Accessoires
Pour simplifier l’installation, Maytag offre les accessoires indiqués ci-dessous, qui peuvent servir ou non, suivant le type
d’installation. Communiquer avec le service à la clientèle Maytag, au 1 800 788-8899, pour obtenir le nom d’un installateur
agréé.
RÉSERVOIRS DE DILATATION EN CAS DE DILATATION THERMIQUE,
CAPACITÉ DE 2 gal (7,6 l), no de pièce 66001013, et de 5 gal (18,9 l),
no de pièce 66001014.
Outils
Suivant le type d’installation, les outils ci-dessous peuvent être
utiles. Ils sont offerts dans les quincailleries.
• Clé à tubes (2) 14 po (356 mm)
• Tournevis
• Cisaille de ferblantier
• Ruban à mesurer ou règle pliante
de 6 pi (1,82 m)
• Tuyau d’arrosage
• Perceuse
• Pâte à joint ou ruban de téflon
PERCEUSE
TOURNEVIS À LAME PLATE
TOURNEVIS À POINTE
CRUCIFORME
CISAILLE DE FERBLANTIER
BACS D’ÉVACUATION DE 22 po (559 mm) DE DIAMÈTRE (no de
pièce 66001011) POUR LES CHAUFFE-EAU DE 20 po (508 mm) OU
MOINS; de 24 po (610 mm) (no de pièce 66001105) POUR LES
CHAUFFE-EAU DE 22 po (559 mm) OU MOINS; DE 28 po (711 mm)
(no de pièce 66001012) POUR LES CHAUFFE-EAU DE 26 po (660 mm)
OU MOINS.
Outils supplémentaires requis
pour la soudure à l’étain
• Coupe-tube ou scie à métaux
• Bouteille de propane
• Brasure tendre
• Flux de brasage
• Toile émeri
• Brosses métalliques
CHALUMEAU
COUPE-TUBE
AU PROPANE
RUBAN DE TÉFLON
(UNIQUEMENT POUR
LES RACCORDS DE
CONDUITES D’EAU)
TUYAU D’ARROSAGE
RUBAN 6 pi
PÂTE À JOINT EN TUBE
POUR LES RACCORDS
DE CONDUITES D’EAU
ET DE GAZ
CLÉ À TUBES
ROULEAU DE
SCIE À MÉTAUX
BROSSE MÉTALLIQUE
3/4 po (19 mm)
BROSSE MÉTALLIQUE
1/2 po (13 mm)
ROULEAU DE
BRASURE TENDRE
SANS PLOMB
TOILE ÉMERI
FLUX DE
BRASAGE
6
Page 39
PRÉPARATION À L’INSTALLATION
Enlèvement de l’ancien chauffe-eau
FIGURE 1
1. Couper l’alimentation en gaz du
chauffe-eau.
4. Raccorder un tuyau flexible au
robinet de vidange, puis au drain
de sol ou à l’extérieur du bâtiment.
Ouvrir le robinet de vidange. Ouvrir
un robinet d’eau chaude situé à
proximité pour détendre la
pression dans le chauffe-eau et
accélérer la vidange. L’eau qui sort
du robinet de vidange peut être très
chaude. Pour éviter tout risque de
brûlure, s’assurer que tous les
raccords sont bien serrés et que
l’écoulement se dirige loin de toute
personne (fig. 1 et 4).
5. Démonter l’évent du coupe-tirage à son point de raccordement au chauffe-eau. Dans la plupart des cas, on peut retirer
l’évent en le soulevant après avoir enlevé les vis ou autres
pièces qui le retiennent. Mettre l’ancien coupe-tirage au rebut,
car le nouveau chauffe-eau exige un coupe-tirage spécial.
6. Si les conduites d’eau sont en cuivre, on peut tailler les
deux tuyaux d’eau avec une scie à métaux, à environ
quatre pouces du point de raccordement au chauffe-eau.
Éviter de les couper trop courts. Au besoin, les raccourcir par
la suite. Démonter la conduite d’évacuation de la soupape
de décharge à sécurité thermique. Une fois le chauffe-eau
vide, retirer le tuyau du robinet de vidange. Fermer le robinet
de vidange. Le chauffe-eau est maintenant entièrement
désinstallé et prêt à être enlevé (fig. 5).
FIGURE 4
Si le robinet d’arrêt commun à tous
les appareils au gaz est utilisé,
fermer aussi le robinet de gaz de
chaque appareil. Laisser tous ces
robinets fermés jusqu’à ce que le
l’installation du chauffe-eau soit
terminée (fig. 1 et 2).
2. Couper l’alimentation en eau en
fermant le robinet d’entrée principal ou le robinet du compteur
d’eau. Certaines installations
exigent de couper l’eau dans tout
le bâtiment (fig. 1 et 3).
3. Vérifier de nouveau que l’alimentation en gaz du chauffeeau est bien fermée (OFF). Débrancher ensuite le tuyau de
gaz du régulateur de gaz.
FIGURE 2
FIGURE 3
FIGURE 5
Si les conduites d’eau sont en acier galvanisé, desserrer le
raccord des deux conduites avec une clé à tubes. Démonter
aussi la tuyauterie raccordée au chauffe-eau. Conserver ces
pièces qui pourraient servir à l’installation du nouveau
chauffe-eau. Démonter la conduite d’évacuation de la
soupape de décharge à sécurité thermique. Une fois le
chauffe-eau vide, retirer le tuyau du robinet de vidange. Fermer
le robinet de vidange. Le chauffe-eau est maintenant
entièrement désinstallé et prêt à être enlevé. Il est possible
que des matières minérales ou des dépôts se soit
accumulés dans l’ancien chauffe-eau, l’alourdissant
considérablement. Le déversement accidentel de ces
résidus risque de causer des salissures (fig. 6).
FIGURE 6
7
Page 40
INSTALLATION TYPE
DESCRIPTION DU CHAUFFE-EAU AU GAZ
A Tuyau d’évent
B Coupe-tirage
C Anode
D Sortie d’eau chaude
E Sortie
F Raccord de la tuyauterie d’eau
G Conduite d’entrée du gaz
H Robinet d’arrêt manuel du gaz
I Raccord à joint rodé
* INSTALLER CONFORMÉMENT
AUX CODES LOCAUX.
* COLLECTEUR D’IMPURETÉS À
PRÉVOIR SUIVANT LES CODES
LOCAUX.
VERS LA BOUCHE
D’ÉVENT DU TOIT
J Collecteur d’impuretés
K Porte d’accès interne
L Porte d’accès externe
M Raccord
N Robinet d’arrêt de l’entrée d’eau
O Entrée d’eau froide
P Tube d’entrée immergé
Q Soupape de décharge à sécurité
thermique
R Plaque signalétique
S Déflecteur(s) de gaz de combustion
T Thermostat
U Robinet de vidange
V Veilleuse et brûleur principal
W Conduit d’évacuation des gaz de
combustion
X Bac d’évacuation
Y Dispositif de verrouillage pour
thermostat (optionnel)
(T) THERMOSTAT
* LA TUYAUTERIE ET LES ACCESSOIRES SONT
À LA CHARGE DU CLIENT.
** UN SYSTÈME FERMÉ EST UN SYSTÈME DONT
LA CONDUITE D’ENTRÉE D’EAU EST MUNIE
DE DISPOSITIFS ANTIREFOULEMENT.
Y
DISPOSITIF DE
VERROUILLAGE
POUR
THERMOSTAT
(OPTIONNEL)
FIGURE 7
(V) VEILLEUSE ET BRÛLEUR PRINCIPAL
(GAZ NATUREL)
(V) VEILLEUSE ET BRÛLEUR PRINCIPAL (PROPANE)
BRÛLEUR DE
LA VEILLEUSE
8
THERMOCOUPLE
BRÛLEUR
PRINCIPAL
Page 41
INSTALLATION TYPE
UTILISATION D’UN ROBINET MÉLANGEUR
FIGURE 8
Cet appareil est de conception certifiée conforme à la norme
ANSI/CSA visant les chauffe-eau au gaz. Il convient à l’application suivante :
Chauffage d’eau potable : Tous les modèles conviennent à
cette application.
L’EAU TRÈS CHAUDE PEUT OCCASIONNER DES
BRÛLURES.
Les chauffe-eau sont conçus pour produire de l’eau chaude.
Or le contact avec l’eau chauffée à la température nécessaire
pour la lessive, le lavage de la vaisselle et autres corvées de
nettoyage peut provoquer des blessures permanentes. Le
risque de blessure permanente est plus élevé chez les personnes âgées, les enfants et les personnes handicapées
physiquement ou mentalement. Si ces personnes utilisent
l’eau chaude ou si une loi provinciale ou un code local exige
de limiter la température de l’eau chaude aux robinets, des
précautions particulières doivent être prises. En plus de régler
la température au minimum, on peut installer un dispositif tel
qu’une vanne de mélange à la sortie du chauffe-eau ou un
robinet mélangeur à chaque point d’utilisation d’eau chaude
par ces personnes. Les plomberies vendent ce type de robinet.
Voir figure 8. Consulter le service à la clientèle Maytag, au1 800 788-8899. Suivre les instructions d’installation du
fabricant du robinet. Avant de modifier le réglage en usine du
thermostat, lire la section « Réglage de la température » du
présent manuel (fig. 22 et 23, page 21).
9
Page 42
CHOIX DE L’EMPLACEMENT DU CHAUFFE-EAU ET INSTALLATION
Points à considérer dans le choix
de l’emplacement
L’emplacement du chauffe-eau est très important pour assurer
la sécurité des occupants du bâtiment et pour maximiser le
rendement énergétique de l’appareil. Il convient de le choisir
avec soin. Le chauffe-eau n’est pas conçu pour être installé
dans des maisons préfabriquées (mobiles) ou à l’extérieur.
Pour le remplacement d’un ancien chauffe-eau ou le
déplacement d’un chauffe-eau existant, il est très important
d’observer les directives suivantes :
• Choisir un emplacement intérieur aussi près que possible
de la cheminée ou de l’évent de sortie auquel l’évent du
chauffe-eau sera raccordé et du réseau de tuyauterie d’eau.
• L’emplacement sélectionné doit permettre des dégagements suffisants pour l’entretien et le bon fonctionnement
du chauffe-eau.
• de dispositifs qui coupent à la fois l’arrivée de gaz et d’eau
au chauffe-eau.
Le chauffe-eau doit être installé de manière à ce qu’en cas de
fuite du réservoir ou d’un raccord, l’écoulement d’eau ne risque
pas d’endommager la structure du bâtiment. Ainsi, il n’est pas
recommandé d’installer le chauffe-eau dans une mansarde
ou à un étage supérieur du bâtiment. S’il est impossible d’éviter
de tels emplacements, installer un bac d’évacuation (offert en
quincaillerie) approprié sous le chauffe-eau. Le distributeur
vend ce type de bac. Le bac doit avoir un diamètre minimal d’au
moins 2 po (51 mm) de plus que le chauffe-eau et il doit être
relié par un tuyau à un drain adéquat. Il doit laisser circuler
librement l’air de combustion.
La durée de vie d’un chauffe-eau dépend de la qualité et de la
pression de l’eau ainsi que de l’environnement dans lequel il
est installé. Il arrive qu’un chauffe-eau soit installé là où une
fuite peut causer des dommages matériels, même si un bac
d’évacuation relié à un drain est installé. Toutefois, les risques
de tels dommages peuvent être réduits par l’ajout d’un détecteur
de fuites ou d’un dispositif de coupure de l’eau, utilisé de pair
avec un bac d’évacuation relié à un drain. Ces dispositifs, vendus
dans certaines grandes quincailleries, détectent les fuites et y
réagissent de différentes manières. Il peut s’agir :
• de capteurs fixés dans le bac d’évacuation qui déclenchent
une alarme ou coupent l’arrivée d’eau au chauffe-eau
lorsqu’une fuite est détectée;
• de capteurs fixés dans le bac d’évacuation qui coupent
l’arrivée d’eau principale de la maison lorsque de l’eau est
détectée dans le bac;
INSTALLATION DANS DES BÂTIMENTS (GARAGES,
ENTREPÔTS, ZONES UTILITAIRES, ETC.) POUVANT
CONTENIR DES LIQUIDES OU DES VAPEURS INFLAMMABLES :
Les liquides inflammables, tels que l’essence, les solvants, le
propane (GPL ou butane, etc.) et d’autres substances telles que
les colles émettent des vapeurs inflammables susceptibles d’être
allumées par la flamme de la veilleuse ou par le brûleur principal
du chauffe-eau. Le retour de flamme ou l’incendie qui en
résulterait pourrait causer des brûlures graves ou mortelles à
quiconque se trouvant à proximité, ainsi que des dommages
matériels. Si l’appareil doit absolument être installé dans un tel
lieu, il doit être installé de manière à ce que la flamme de la
veilleuse et celle du brûleur principal soient élevées d’au moins
18 po par rapport au sol. Cela réduira les risques que des vapeurs
inflammables, dues à un déversement sur le plancher,
s’enflamment, mais il faut tout de même éviter d’entreposer ou
d’utiliser de l’essence ou d’autres substances inflammables
dans la pièce ou à proximité de la pièce où se trouve un chauffeeau au gaz ou tout autre appareil à flamme nue ou générateur
d’étincelles. REMARQUE : En raison de courants d’air, des
vapeurs inflammables d’autres pièces peuvent être attirées vers
l’appareil.
• de dispositifs de coupure de l’eau qui s’activent en fonction
de la différence entre la pression à l’entrée d’eau froide et à
la sortie d’eau chaude;
De plus, le chauffe-eau doit être situé ou protégé de manière
à éliminer tout risque d’endommagement par des véhicules
en mouvement.
10
Page 43
Le chauffe-eau ne doit pas être installé directement sur un
tapis. Le cas échéant, il faut protéger le tapis au moyen d’un
panneau de métal ou de bois placé au-dessous du chauffeeau et dépassant l’appareil d’au moins 3 po (76,2 mm) de
tous les côtés. Si le chauffe-eau est installé dans une alcôve
ou dans un placard, le panneau doit recouvrir la totalité du
plancher. Toute négligence à observer cette mise en garde
entraîne un risque d’incendie.
Un chauffe-eau au gaz ne peut pas fonctionner normalement
s’il ne reçoit pas la quantité d’air nécessaire à la combustion.
Ne pas installer le chauffe-eau dans un espace clos (par ex.,
dans un placard) à moins de ménager une entrée d’air tel
qu’indiqué à la section « Choix de l’emplacement du chauffeeau et installation ». Ne jamais restreindre la circulation de
l’air de ventilation. En cas de doute ou pour des renseignements supplémentaires, appeler le fournisseur de gaz.
Toute négligence à prévoir la quantité d’air de combustion
nécessaire peut causer un incendie ou une explosion et
entraîner des blessures graves ou mortelles, et des
dommages matériels.
FIGURE 10
Pour les installations dans un salon de beauté, un salon de
coiffure, une entreprise de nettoyage ou une laverie automatique
contenant du matériel de nettoyage à sec, il est impératif que
l’air de combustion et l’air de ventilation soient prélevés à
l’extérieur de ces zones.
Les dégagements minimaux entre le chauffe-eau et tout
matériau ou objet combustible sont de 0 po sur les côtés et à
l’arrière, de 4 po (102 mm) à l’avant et de 6 po (153 mm) par
rapport au tuyau d’évent. Le dégagement à prévoir à partir du
haut de la chemise est de 12 po (305 mm) pour la plupart des
modèles. Un dégagement plus faible est autorisé pour certains
modèles. Cette information figure sur l’étiquette se trouvant
près du régulateur de gaz du chauffe-eau (fig. 9).
FIGURE 9
Les propulseurs d’aérosol et certains composés volatils
(nettoyants, produits chimiques à base de chlore, fluides
frigorigènes, etc.), en plus d’être souvent très inflammables,
se transforment aussi en acide chlorhydrique (très corrosif)
lorsqu’ils entrent en contact avec les produits de combustion
du chauffe-eau. Les conséquences peuvent être dangereuses
et provoquer la défaillance de l’appareil.
Revêtements isolants
Des revêtements isolants pour chauffe-eau au gaz sont offerts
sur le marché, mais ils sont superflus pour les produits
Maytag. Le but d’un tel revêtement est de réduire la perte de
chaleur de l’eau chaude de réserve des chauffe-eau à
réservoir. Étant donné que le chauffe-eau Maytag satisfait
aux normes de RNCan visant l’isolation et la perte de chaleur
de l’eau chaude de réserve, ou les dépasse, le revêtement
isolant est superflu.
11
Page 44
AVERTISSEMENT
Si le chauffe-eau est tout de même recouvert d’un revêtement,
observer les consignes qui suivent (voir la figure 7 pour situer
les éléments mentionnés ci-dessous). Le défaut de suivre
ces consignes peut avoir pour effet de réduire le débit d’air
nécessaire à la combustion, entraînant des risques d’asphyxie,
de blessures graves ou mortelles et d’incendie.
• Ne pas placer le revêtement sur le dessus du chauffe-eau,
car il nuira au fonctionnement sécuritaire du coupe-tirage.
• Ne pas recouvrir la porte d’accès externe, le thermostat ni la
soupape de décharge à sécurité thermique.
• Le revêtement doit être à plus de 2 po (50,8 mm) du sol
pour permettre à l’air de circuler librement vers le brûleur.
• Ne pas cacher le manuel d’instructions sous le revêtement
isolant. Il doit être conservé sur le côté du chauffe-eau ou à
proximité afin de pouvoir être consulté au besoin.
• Se procurer de nouvelles étiquettes de mise en garde et
d’instructions auprès de Maytag et les apposer sur le
revêtement, au-dessus des étiquettes existantes.
• Inspecter fréquemment le revêtement pour s’assurer qu’il
ne pend pas et que l’air s’écoule librement.
Air de combustion et air de ventilation
en espace ouvert
On entend par ESPACE OUVERT un espace dont le volume
est égal ou supérieur à 50 pi3 par 1 000 Btu/h (4,8 m3/kW) de
débit calorifique nominal total de tous les appareils installés
dans cet espace. Les pièces qui communiquent directement,
par des ouvertures non munies de portes, avec l’espace où
sont installés ces appareils sont considérées comme faisant
partie de l’espace ouvert.
calorifique nominal total de tous les appareils au gaz installés
dans l’espace clos, minimum 100 po2 (645 cm2). L’une des
ouvertures doit se trouver à 12 po (30 cm) ou moins du sommet
de l’enceinte et l’autre à 12 po (30 cm) ou moins du bas de
l’enceinte.
FIGURE 11
B. L’AIR EST ENTIÈREMENT TIRÉ DE L’EXTÉRIEUR DU
BÂTIMENT (fig. 12, 13 et 14)
L’espace clos doit être muni de deux ouvertures
permanentes, l’une devant se trouver à 12 po (30 cm) ou
moins du sommet de l’enceinte et l’autre à 12 po (30 cm)
ou moins du bas de l’enceinte. Ces ouvertures doivent
communiquer directement ou par un conduit avec l’extérieur
ou avec les zones (galeries ou mansardes) qui communiquent directement avec l’extérieur.
Si le bâtiment contient des espaces ouverts, il se peut que
l’infiltration d’air soit suffisante pour assurer l’apport d’air
nécessaire à la combustion et à la ventilation et pour assurer
la dilution des gaz de combustion. En revanche, dans un
bâtiment de construction étanche (où se trouvent des
éléments tels que coupe-froid, isolation importante,
calfeutrage, pare-vapeur, etc.), il faut prévoir un apport d’air.
Pour ce faire, utiliser une des méthodes décrites à la section
« Air de combustion et air de ventilation en espace clos ».
Air de combustion et air de ventilation
en espace clos
On entend par ESPACE CLOS un espace dont le volume est
inférieur à 50 pi3 par 1 000 Btu/h (4,8 m3/kW) de débit calorifique nominal total de tous les appareils installés dans cet
espace.
A. L’AIR EST ENTIÈREMENT TIRÉ DE L’INTÉRIEUR DU
BÂTIMENT (fig. 10 et 11)
L’espace clos doit être muni de deux ouvertures permanentes
communiquant directement avec une ou plusieurs pièces de
volume suffisant pour que le volume combiné de tous les
espaces satisfasse aux critères établis pour un espace ouvert.
Pour vérifier cette condition, il faut tenir compte du débit d’entrée
total de tous les appareils au gaz installés dans l’espace
combiné. Chaque ouverture doit comporter une surface libre
d’au moins 1 po
2
par 1 000 Btu/h (22 cm2/kW) de débit
FIGURE 12
• Chaque ouverture qui communique directement avec
l’extérieur doit comporter une surface libre d’au moins 1 po
par 4 000 Btu/h (5,5 cm2/kW) de débit calorifique nominal
total de tous les appareils se trouvant dans l’enceinte (fig. 12).
• Chaque ouverture qui communique avec l’extérieur par un
conduit vertical doit comporter une surface libre d’au moins
1 po2 par 4 000 Btu/h (5,5 cm2/kW) de débit calorifique
nominal total de tous les appareils se trouvant dans
l’enceinte (fig. 13).
12
2
Page 45
Tuyauterie d’eau
FIGURE 13
• Chaque ouverture qui communique avec l’extérieur par un
conduit horizontal doit comporter une surface libre d’au
moins 1 po
2
par 2 000 Btu/h (11 cm2/kW) de débit calorifique
nominal total de tous les appareils se trouvant dans
l’enceinte (fig. 14).
• Si des conduits sont utilisés, l’aire de leur section
transversale doit être la même que la surface libre de
l’ouverture à laquelle ils sont raccordés. Le côté le plus
petit d’un conduit de section rectangulaire ne doit pas être
inférieur à 3 po (76,2 mm) (fig. 14).
FIGURE 14
L’EAU TRÈS CHAUDE PEUT OCCASIONNER DES
BRÛLURES.
Les chauffe-eau sont conçus pour produire de l’eau chaude.
Or le contact avec l’eau chauffée à la température nécessaire
pour la lessive, le lavage de la vaisselle et autres corvées de
nettoyage peut provoquer des blessures permanentes. Le
risque de blessure permanente est plus élevé chez les personnes âgées, les enfants et les personnes handicapées
physiquement ou mentalement. Si ces personnes utilisent
l’eau chaude ou si une loi provinciale ou un code local exige
de limiter la température de l’eau chaude aux robinets, des
précautions particulières doivent être prises. En plus de régler
la température à la valeur la plus basse possible, on peut
installer un dispositif tel qu’une vanne de mélange à la sortie
du chauffe-eau ou un robinet mélangeur à chaque point
d’utilisation d’eau chaude par ces personnes. Les plomberies
vendent ce type de robinet (fig. 8, page 9; fig. 15 ci-dessous).
Consulter le service à la clientèle Maytag (1 800 788-8899).
Suivre les instructions d’installation du fabricant du robinet.
Avant de modifier le réglage du thermostat prévu à l’usine,
lire la section « Réglage de la température » du présent
manuel.
• Louvres et grilles de ventilation : Dans le calcul de la surface
libre d’une ouverture, il faut tenir compte de l’effet d’obstruction créé par les louvres et les grilles de ventilation. Les
mailles des grilles de ventilation ne doivent pas être
inférieures à 1/4 po (6,4 mm). Si la surface libre du louvre
ou de la grille est connue, on peut l’utiliser pour calculer les
dimensions nécessaires de l’ouverture afin d’obtenir la
surface libre requise. Si la surface libre du louvre ou de la
grille est inconnue, on peut supposer que la surface libre
d’un louvre en bois représente de 20 à 25 % de sa surface
apparente et que la surface libre d’un louvre ou d’une grille
en métal représente de 60 à 75 % de sa surface apparente.
Les louvres et les grilles doivent être installés en position
ouverte permanente ou être asservis au chauffe-eau et
commandés automatiquement par l’appareil en marche.
• Conditions spéciales créées par les foyers ou les dispositifs
d’évacuation mécanique : L’utilisation de ventilateurs
d’évacuation, de systèmes de ventilation, de sécheuses ou
de foyers crée des conditions qui exigent une attention
particulière pour éviter le fonctionnement insatisfaisant des
appareils au gaz.
FIGURE 15
Le chauffe-eau ne doit pas être raccordé à un système de
chauffage ou à un élément desservi par un appareil de
chauffage d’eau non potable.
13
Page 46
Aucun produit chimique toxique, comme ceux servant au traitement des chaudières, ne doit être introduit dans ce système.
Pour remédier aux effets des surpressions, des coupures
fréquentes, des coups de bélier, etc., le réseau de distribution
d’eau peut avoir été équipé de dispositifs de protection tels
que détendeurs de pression, clapets de retenue et dispositifs
antirefoulement entre la canalisation publique et l’entrée du
chauffe-eau. Si ces dispositifs ne comportent pas de dérivation
interne et si aucune mesure corrective n’est prise le cas échéant,
le système d’alimentation en eau chaude risque de se transformer en circuit fermé. Les systèmes en circuit fermé ne
permettent pas d’absorber la surpression créée par la dilatation
de l’eau lorsque la température augmente.
Lorsqu’elle est chauffée, l’eau du réservoir se dilate, ce qui
augmente la pression dans le système d’alimentation. Dès
que la pression d’ouverture de la soupape de décharge du
chauffe-eau est atteinte, la soupape limite automatiquement
la surpression. Cependant, il faut se rappeler que la soupape
de décharge n’a pas pour rôle de limiter en permanence la
surpression causée par la dilatation thermique de l’eau. En
fait, une telle situation est inacceptable et doit être corrigée. Il
est recommandé que tous les dispositifs de protection pouvant
avoir pour effet de « fermer » le circuit soient munis d’une
dérivation ou que le système soit équipé d’un réservoir
d’expansion capable de limiter la surpression. Se reporter
au paragraphe « Dilatation thermique » de la section
« Dépannage », se renseigner auprès des autorités compétentes en matière de plomberie ou s’adresser au service à la
clientèle Maytag, au 1 800 788-8899, pour connaître le nom
d’un installateur agréé capable de remédier à la situation.
trois épaisseurs de ruban de téflon sur l’extrémité exposée
du mamelon fileté 1 po NPT. Raccorder la conduite d’eau
froide à l’entrée d’eau froide du chauffe-eau.
REMARQUE : Le chauffe-eau est muni d’un isolant
thermique superefficace, qui réduit au minimum la perte
de chaleur du réservoir. Pour réduire davantage les pertes
de chaleur, isoler les conduites d’eau chaude.
REMARQUE : Si le chauffe-eau est raccordé à une tuyauterie
en cuivre, il est fortement recommandé de lui installer des
raccords ou manchons diélectriques pour protéger le
système contre la corrosion prématurée des raccords de la
tuyauterie d’eau chaude et d’eau froide.
La figure 16 présente le raccordement type de la tuyauterie
d’eau au chauffe-eau. Le chauffe-eau de 75 gal de capacité
est équipé de raccords de tuyauterie d’eau 1 po NPT.
REMARQUE : Pour les tuyaux en cuivre, souder un adaptateur
au tuyau de cuivre avant de raccorder l’adaptateur au raccord
d’eau froide ou d’eau chaude du chauffe-eau. Ne pas
souder le tuyau d’arrivée d’eau froide directement sur la prise
d’eau froide du réservoir. Cela endommagerait le tube
d’entrée immergé et le réservoir.
• Regarder sur le dessus du chauffe-eau : l’inscription
« HOT » indique la sortie d’eau chaude. Enrouler deux ou
trois épaisseurs de ruban de téflon sur l’extrémité exposée
du mamelon fileté 1 po NPT. Raccorder le tuyau d’eau
chaude à la sortie d’eau chaude du chauffe-eau.
• Regarder sur le dessus du chauffe-eau : l’inscription
« COLD » indique l’entrée d’eau froide. Enrouler deux ou
FIGURE 16
Soupape de décharge à sécurité thermique
Ce chauffe-eau est équipé par le fabricant d’une soupape de
décharge à sécurité thermique dûment certifiée.
Cette soupape est certifiée par un laboratoire d’essai national
reconnu, qui inspecte périodiquement la production de
l’équipement répertorié pour en vérifier la conformité avec la
norme relative aux soupapes de décharge pour les systèmes
14
Page 47
d’alimentation en eau chaude, ANSI Z21.22 • CSA 4.4 et aux
spécifications de l’ASME.
Si cette soupape est remplacée, la soupape de rechange doit
non seulement satisfaire aux codes locaux, mais aussi être
certifiée conforme aux indications du paragraphe précédent.
La pression d’ouverture maximale de la soupape doit être
inscrite sur celle-ci et ne doit en aucun cas dépasser la pression
de service maximale indiquée sur le chauffe-eau (150 lb/po
2
=
1 035 kPa). De plus, le débit d’évacuation de la soupape de
décharge ne doit pas être inférieur au débit d’entrée d’eau du
chauffe-eau indiqué sur la plaque signalétique.
Pour garantir la sécurité de fonctionnement du chauffe-eau, la
soupape de décharge ne doit jamais être retirée du chauffeeau ni obturée.
La soupape de décharge doit être installée directement dans
l’orifice prévu à cet effet sur le chauffe-eau. Orienter la soupape
de manière à en diriger l’orifice d’évacuation vers le bas et
prévoir une conduite d’évacuation débouchant au-dessous du
sol ou à moins de 6 po (153 mm) au-dessus. Veiller à ce que
la conduite d’évacuation n’entre pas en contact avec un
conducteur électrique. La conduite d’évacuation ne doit jamais
être obturée ni présenter d’étranglement. Une longueur
excessive, supérieure à 30 pi (9,14 m), ou la présence de plus
de quatre coudes, peuvent provoquer un étranglement et
réduire le débit d’évacuation de la soupape (fig. 17).
La conduite d’évacuation :
• doit avoir un diamètre au moins égal à celui de l’orifice de
sortie de la soupape de décharge et ne doit contenir aucun
raccord de réduction ou autre élément obstructif.
• ne doit jamais être obstruée ou bouchée.
• doit être fabriquée d’un matériau répertorié pour les
systèmes d’alimentation en eau chaude.
• doit être installée de manière à permettre l’évacuation
complète de l’eau, tant de la soupape que de la conduite.
• doit déboucher au-dessus d’un drain adéquat.
• de plus, aucun robinet ne doit être installé entre la soupape
de décharge et le réservoir.
Aucune autre soupape ou élément obstructif ne doit être installé
entre la soupape de décharge et le réservoir. Ne pas raccorder
l’extrémité de la conduite directement dans le drain
d’évacuation sans laisser un espace d’air de 6 po. Pour éliminer
les risques de dommages matériels et de blessures graves
ou mortelles, la soupape de décharge doit être en mesure
d’évacuer la quantité d’eau imposée par les circonstances. Si
la conduite d’évacuation n’est pas raccordée à un drain ou à
un dispositif d’évacuation adéquat, l’eau qui s’en écoule risque
d’entraîner des dégâts matériels.
La soupape de décharge doit être ouverte manuellement au
moins une fois par an. Pendant l’opération, s’assurer que
personne ne se trouve devant ou près de la sortie de la conduite
d’évacuation de la soupape et que l’eau très chaude qui en
sort ne cause pas de blessures ni de dommages matériels.
Si la soupape de décharge ne revient pas à sa position initiale
après l’ouverture manuelle et qu’elle continue de laisser
s’écouler de l’eau, fermer immédiatement le robinet d’eau
froide à l’entrée du chauffe-eau, vidanger le chauffe-eau
conformément aux instructions ci-dessous et remplacer la
soupape par une soupape neuve.
Remplissage du chauffe-eau
FIGURE 17
15
Page 48
Ne jamais utiliser un chauffe-eau qui n’est pas plein d’eau.
Pour ne pas endommager le réservoir, le chauffe-eau doit
être entièrement rempli. Avant d’ouvrir la commande de gaz,
l’eau doit s’écouler des robinets d’eau chaude.
Pour remplir le chauffe-eau :
• Fermer le robinet de vidange du chauffe-eau en tournant la
manette à droite (sens horaire). Ce robinet se trouve sur la
partie inférieure avant du chauffe-eau.
• Ouvrir le robinet d’entrée d’eau froide en amont du chauffeeau. REMARQUE : Le robinet d’entrée d’eau froide doit
être maintenu ouvert pendant que le chauffe-eau est en
service.
• Pour que le réservoir se remplisse au complet, ouvrir le
robinet d’eau chaude le plus proche pour laisser l’air
s’échapper du système. Laisser le robinet ouvert jusqu’à
ce que le débit devienne constant. L’air aura alors été évacué
du chauffe-eau et de la tuyauterie.
• Inspecter la tuyauterie d’eau et les raccords à la recherche
de fuites. Au besoin, effectuer les réparations nécessaires.
Ventilation
Pour assurer la ventilation adéquate du chauffe-eau, choisir
un évent de diamètre suffisant. Si d’autres appareils au gaz
partagent l’évent, tout ajout ou retrait d’un appareil branché à
l’évent commun risque de nuire au fonctionnement du
chauffe-eau. Pour obtenir plus de détails sur ce genre de
changement, consulter le centre de service à la clientèle
Maytag, au 1 800 788-8899, ou le fournisseur de gaz.
Dans certaines installations, un évent de plus grand diamètre
peut s’avérer nécessaire. Consulter le service à la clientèle
Maytag, au 1 800 788-8899, ou le fournisseur de gaz pour
déterminer le système de ventilation le mieux adapté au
chauffe-eau, selon les tables d’évent figurant dans la version
courante du code d’installation CAN/CSA B149.1.
À intervalles réguliers, vérifier si le système de ventilation
présente des signes d’obstruction ou de détérioration. Au
besoin, remplacer les éléments défectueux.
L’air de ventilation et l’air de combustion doit circuler librement.
Le chauffe-eau, muni du coupe-tirage, doit être raccordé à une
cheminée ou à un évent approuvé communiquant avec
l’extérieur. Ne jamais utiliser le chauffe-eau avant qu’il ne soit
doté d’une prise d’air et qu’il reçoive suffisamment d’air de
l’extérieur pour éliminer les risques de mauvais fonctionnement, d’explosion ou d’asphyxie.
REGISTRES D’ÉVENT MOTORISÉS – Tout registre motorisé,
à commande thermique ou autre, doit être retiré du système
s’il nuit au tirage du chauffe-eau.
Registres d’évent motorisés à commande thermique : Les
chauffe-eau au gaz dont le rendement thermique dépasse
80 % peuvent produire des gaz de combustion à températures
relativement basses qui peuvent s’avérer insuffisantes pour
ouvrir de tels volets comme il se doit. Le cas échéant, un
débordement des gaz de combustion se produit, risquant de
causer un empoisonnement au monoxyde de carbone.
Les registres d’évent doivent porter une marque de certification
indiquant qu’ils sont conformes à la version courante de la
norme ANSI Z21.66/CGA 6.14 (qui vise les registres à
commande électrique et à commande mécanique). Avant
d’installer un registre d’évent, consulter le service à la
clientèle Maytag, au 1 800 788-8899, ou le fournisseur de
gaz pour obtenir plus de détails.
• Fixer le coupe-tirage de façon que ses pieds soient
légèrement inclinés vers l’intérieur.
• Placer les pieds du coupe-tirage dans les orifices
correspondants situés au sommet du chauffe-eau. Les pieds
s’insèrent à pression dans les orifices pour s’y ajuster. Fixer
le coupe-tirage au moyen des attaches prévues à cet effet.
• Placer l’évent sur le coupe-tirage. Avec l’évent en position,
percer un petit trou à travers l’évent et le coupe-tirage. Fixer
l’ensemble au moyen de vis à tôle (fig. 18).
Un système de ventilation obstrué ou défectueux peut
occasionner de graves risques pour la santé et même un
danger d’asphyxie.
FIGURE 18
Le diamètre de l’évent du chauffe-eau ne doit pas être inférieur
à celui du conduit de sortie du coupe-tirage. De plus, sa partie
horizontale doit avoir une pente ascendante d’au moins 1/4 po
par pied linéaire (21 mm/m) (fig. 19).
VERS LA
CHEMINÉE
PENTE ASCENDANTE
MIN. DE 1/4 po PAR
PIED LINÉAIRE
(21 mm/m)
FIGURE 19
16
Page 49
Les gaz de combustion doivent être entièrement évacués vers
l’extérieur du bâtiment (ou de l’habitation). N’utiliser que le
coupe-tirage fourni avec le chauffe-eau. N’en utiliser aucun autre.
Les tuyaux d’évent doivent être fixés à chaque joint par des vis
à tôle.
Il faut prévoir un dégagement minimal de 6 po (153 mm) entre
un tuyau d’évent à paroi simple et tout matériau ou objet
combustible. Le dégagement doit être comblé avec du mortier,
du ciment ou d’autres matières non combustibles. Pour
d’autres types de tuyau d’évent, suivre les directives de
dégagement du fabricant. Pour assurer le parfait ajustage du
tuyau d’évent dans une cheminée en brique, sceller le pourtour
du tuyau avec du mortier ou du ciment.
La conduite de gaz du chauffe-eau doit être de diamètre
suffisant. À cet effet, consulter le code d’installation
CAN/CSA B149.1 (éd. courante) et le fournisseur de gaz
local.
Cette conduite doit comporter :
• un robinet de gaz directement accessible sur la conduite
de gaz desservant le chauffe-eau;
Toute négligence à prévoir le dégagement exigé entre l’évent
et tout matériau combustible entraîne un risque d’incendie.
S’assurer que le tuyau d’évent est convenablement raccordé,
afin de prévenir les fuites de gaz toxiques qui pourraient
causer une asphyxie mortelle.
La présence de vapeurs chimiques dans l’air de combustion
peut entraîner la corrosion du système de ventilation et
d’évacuation des gaz de combustion. Les propulseurs
d’aérosol, les solvants de nettoyage, les réfrigérants pour
réfrigérateurs et climatiseurs, les produits chimiques pour
piscines, le chlorure de calcium, le chlorure de sodium, les
cires, les agents de blanchiment et les produits chimiques
industriels peuvent provoquer une telle corrosion.
Tuyauterie de gaz
• un collecteur d’impuretés, en amont du régulateur de gaz,
pour empêcher la saleté et les corps étrangers d’atteindre
le régulateur;
• un raccord flexible ou un raccord à joint rodé entre le robinet
d’arrêt et le régulateur, afin de permettre l’entretien du
chauffe-eau.
Avant d’allumer le chauffe-eau, s’assurer que la tuyauterie ne
présente pas de fuites. Le faire à l’aide une solution d’eau
savonneuse et non d’une allumette ou d’une flamme nue.
Rincer la solution et sécher.
La pression minimale du gaz spécifiée sur la plaque signalétique sert uniquement au réglage de la pression d’entrée.
S’assurer que le gaz fourni est du type indiqué sur la plaque
signalétique du chauffe-eau. La pression du gaz à l’entrée du
chauffe-eau ne doit pas dépasser 14 po CE (2,6 kPa) pour le
gaz naturel ou le gaz propane (GPL). Si le régulateur de gaz est
soumis à une pression dépassant 1/2 lb/po
2
(3,5 kPa), il peut
être endommagé et causer des fuites de gaz entraînant des
risques d’incendie ou d’explosion.
Si le système de distribution de gaz comporte un robinet de
gaz central, commun à tous les appareils, fermer aussi le
robinet de gaz de chaque appareil. Laisser tous ces robinets
fermés jusqu’à la fin de l’installation.
Les modèles standards sont conçus pour être installés à une
altitude pouvant atteindre 2 000 pi (610 m).
Les modèles haute altitude sont conçus pour être installés à
une altitude allant de 2 000 pi (610 m) à 4 500 pi (1 370 m).
17
Page 50
Au-dessus de 2 000 pi (610 m) d’altitude (modèle standard)
ou de 4 500 pi (1 370 m) d’altitude (modèle haute altitude), le
débit doit être réduit à raison de 4 % par 1 000 pi (305 m)
au-dessus du niveau de la mer. Pour ce faire, il faut remplacer
l’orifice du brûleur conformément à la norme CAN/CSA B149.1.
Pour plus de détails, communiquer avec le service à la
clientèle Maytag, au 1 800 788-8899, ou le fournisseur de
gaz.
Ne pas remplacer l’orifice standard par un orifice haute altitude
pour une installation à plus de 2 000 pi (610 m) d’altitude, ou
de 4 500 pi (1 370 m) pour le modèle haute altitude, peut
entraîner des anomalies de fonctionnement et l’inefficacité du
chauffe-eau, accompagnées d’un dégagement de monoxyde
de carbone supérieur aux limites de sécurité et présentant
des risques de blessures graves ou de mort. Communiquer
avec le service à la clientèle Maytag, au 1 800 788-8899, ou
le fournisseur de gaz pour savoir si des modifications
particulières sont exigées dans la région.
« Tuyauterie de gaz ». Consulter la version courante des codes
CAN/CSA B149.1 ou les codes d’installation locaux.
Au moment d’installer le chauffe-eau, un collecteur d’impuretés
doit être placé aussi près que possible de l’entrée de gaz du
chauffe-eau. Ce collecteur peut être un raccord en T terminé
par un mamelon vertical obturé par un bouchon à sa sortie ou
tout autre dispositif capable de collecter efficacement les
impuretés. Si un raccord en T est utilisé, il doit être installé
selon l’une des méthodes représentées (fig. 20 et 21).
Utiliser de la pâte à joint ou du ruban adhésif en téflon résistant
aux gaz de pétrole liquéfiés (propane).
Avant de mettre le chauffe-eau en marche, vérifier si l’appareil
et les raccords à la tuyauterie de gaz présentent des fuites.
Pour tester le système de distribution du gaz à une pression
supérieure à 1/2 lb/po2 (3,5 kPa), le chauffe-eau et son robinet
d’arrêt doivent être coupés de la conduite d’alimentation de
gaz. Pour les tests à une pression égale ou inférieure à
1/2 lb/po2 (3,5 kPa), le chauffe-eau n’a pas à être coupé du
système, mais il doit être isolé de la conduite d’alimentation
de gaz par la fermeture de son robinet d’arrêt.
Le raccordement de la conduite de gaz au régulateur de gaz
du chauffe-eau peut se faire suivant l’une des méthodes
représentées ci-après (fig. 20, 21).
Collecteur d’impuretés
La présence de contaminants à l’intérieur de la conduite de
gaz peut entraîner le mauvais fonctionnement du régulateur
de gaz, ce qui risque de provoquer un incendie ou une explosion.
Avant de raccorder la conduite de gaz, s’assurer que toute
la tuyauterie de gaz est propre à l’intérieur. Pour recueillir
toute la saleté ou les corps étrangers pouvant circuler dans la
conduite de gaz, installer un collecteur d’impuretés juste avant
le régulateur de gaz. Ce collecteur doit être directement
accessible. L’installer suivant les indications de la section
FIGURE 20 – TUYAUTERIE DE GAZ AVEC RACCORD FLEXIBLE
FIGURE 21 – TUYAUTERIE DE GAZ EN FER NOIR MENANT
À LA COMMANDE DE GAZ
18
Page 51
19
Page 52
POUR VOTRE SÉCURITÉ LISEZ AVANT D’ALLUMER
AVERTISSEMENT :Quiconque ne respecte pas à la lettre les
instructions dans la présente notice risque de déclencher un incendie
ou une explosion entraînant des dommages, des blessures ou la mort.
AVANT D’ALLUMER : REMPLISSEZ ENTIÈREMENT LE SYSTÈME D’EAU ET PURGEZ TOUTES LES CONDUITES AU ROBINET.
A. Cet appareil est muni d’une veilleuse qui doit être allumée
manuellement. Respectez les instructions ci-dessous à la
lettre.
B. AVANT D’ALLUMER LA VEILLEUSE, reniflez tout autour
de l’appareil pour déceler une odeur de gaz. Reniflez près
du plancher, car certains gaz sont plus lourds que l’air et
peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir
des téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz
INSTRUCTIONS D’ALLUMAGE
FIGURE 1
1.ARRÊTEZ! Lisez les instructions de sécurité sur la
portion supérieure de cette étiquette.
2. Réglez le thermostat à la température la plus basse en
tournant le cadran à fond dans le sens horaire .
3. Enfoncez légèrement le bouton d’admission du gaz, puis
tournez-le dans le sens horaire jusqu’à la position
OFF (FERMÉ) (fig. A).
REMARQUE : Ce bouton ne peut être tourné de la position
PILOT (VEILLEUSE) à la position OFF que s’il est légèrement
enfoncé. Ne le forcez pas.
4. Retirez les panneaux d’accès interne et externe se
trouvant dessous et derrière la commande de gaz.
5. Attendre cinq minutes pour laisser échapper tout le gaz.
Reniflez tout autour de l’appareil, y compris près du
plancher, pour déceler une odeur de gaz. Si vous
sentezune odeur de gaz, ARRÊTEZ! Passez à
l’étape B des instructions de sécurité sur la portion
supérieure de cette étiquette. S’il n’y a pas d’odeur de
gaz, passez à l’étape suivante.
6. Repérez la veilleuse en suivant le tube de métal à partir
du bas de la commande de gaz, à droite, vers le brûleur
(fig. D).
7. Tournez le bouton d’admission du gaz dans le sens
antihoraire jusqu’à la position PILOT (VEILLEUSE)
(fig. B).
8. Enfoncez complètement le bouton d’admission du gaz
VUE DE DESSUS
depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le
service des incendies.
C. Ne poussez ou tournez le bouton d’admission du gaz qu’à
la main; ne jamais utiliser d’outil. Si le bouton reste coincé,
ne tentez pas de le réparer; appelez un technicien qualifié.
Le fait de forcer le bouton ou de le réparer peut déclencher
une explosition ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même
partiellement. Faites inspecter l’appareil par un technicien
qualifié et remplacez toute partie du système de contrôle et
toute commande qui ont été plongés dans l’eau.
FIGURE D
aintenez-le enfoncé. Allumez sans tarder la veilleuse avec
une allumette. Maintenez le bouton d’admission du gaz
enfoncé pendant environ une (1) minute après que la
veilleuse s’est allumée. Relâchez le bouton pour qu’il
revienne à sa position initiale. La veilleuse doit rester
allumée. Si elle s’éteint, reprendre les étapes 3 à 8.
Plusieurs minutes peuvent s’écouler avant que la
veilleuse ne s’allume, car tout l’air accumulé dans la
tuyauterie de gaz doit préalablement être purgé.
• Si le bouton ne se soulève pas de lui-même lorsqu’on
le relâche, arrêtez et appelez immédiatement un
technicien qualifié ou le fournisseur de gaz.
• Si la veilleuse ne reste pas allumée après plusieurs
tentatives, réglez le bouton d’admission du gaz à la
position OFF et appeler un technicien d’entretien ou
le fournisseur de gaz.
9.Replacez les portes d’accès interne et externe.
10. En vous tenant à distance, tournez le bouton d’admission
du gaz dans le sens antihoraire jusqu’à la position
ON (OUVERT) (fig. C).
11. Réglez le thermostat à la température désirée (fig. 1).
ATTENTION : En augmentant la température
de l’eau, on augmente aussi les risques de
brûlures. Avant de changer le réglage de la
température, consultez le présent manuel.
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. Réglez le thermostat à la température la plus basse.
2. Appuyez légèrement sur le bouton d’admission du gaz et
tournez-le dans le sens horaire jusqu’à la position OFF
(FERMÉ) (fig. A). Ne le forcez pas.
20
Page 53
Réglage de la température
Des cycles de chauffage courts et répétés, causés par de
brèves périodes de consommation d’eau chaude, peuvent
entraîner des températures aux points de prélèvement qui
dépassent de 30 °F (16,7 °C) la température de consigne.
Avec ce type de consommation, il est souhaitable de régler le
thermostat à une température plus basse afin de réduire les
risques de brûlures.
Le but de tout chauffe-eau est de chauffer l’eau. L’eau chaude
non tempérée nécessaire pour le nettoyage, le rinçage et la
désinfection (hygiène personnelle, lave-vaisselle, lessiveuses)
peut causer des brûlures. Selon la durée d’exposition et les
personnes exposées (adultes, enfants, personnes âgées,
personnes handicapées, etc.), la brûlure peut se produire à
des températures différentes.
Avant de modifier le réglage du thermostat prévu à l’usine,
lire la section « Réglage de la température » du présent
manuel (fig. 22, 23).
Ne jamais laisser de jeunes enfants ouvrir un robinet d’eau
chaude ou se faire couler un bain. Ne jamais laisser un enfant
ou une personne handicapée sans surveillance dans la
baignoire ou sous la douche.
REMARQUE : La plupart des fabricants de lave-vaisselle
recommandent une température entre 120 et 140 °F (49 et
60 °C).
Le thermostat du chauffe-eau a été réglé au minimum en usine
(position PILOT LIGHTING). Il s’agit de le régler à la
température voulue. La marque (
), qui correspond à une
température d’environ 120 °F (49 °C), est le point de départ
recommandé. Certains codes locaux ou provinces exigent un
point de réglage plus bas.
L’EAU TRÈS CHAUDE PEUT OCCASIONNER DES BRÛLURES.
Les chauffe-eau sont conçus pour produire de l’eau chaude.
Or le contact avec l’eau chauffée à la température nécessaire
pour la lessive, le lavage de la vaisselle et autres corvées de
nettoyage peut provoquer des blessures permanentes. Le
risque de blessure permanente est plus élevé chez les personnes âgées, les enfants et les personnes handicapées
physiquement ou mentalement. Si ces personnes utilisent
l’eau chaude ou si une loi provinciale ou un code local exige
de limiter la température de l’eau chaude aux robinets, des
précautions particulières doivent être prises. En plus de régler
la température à la valeur la plus basse possible, on peut
installer un dispositif tel qu’une vanne de mélange à la sortie
du chauffe-eau ou un robinet mélangeur à chaque point
d’utilisation d’eau chaude par ces personnes. Les plomberies
vendent ce type de vanne (fig. 8, page 9, et fig. 15, page 13).
Consulter le service à la clientèle Maytag (1 800 788-8899).
Suivre les instructions d’installation du fabricant du robinet.
Tourner le cadran du thermostat à droite (
) pour diminuer la
température ou à gauche ( ) pour l’augmenter.
En cas de surchauffe ou si l’alimentation de gaz ne s’arrête
pas, fermer manuellement le robinet d’arrêt du gaz.
FIGURE 22
Points de(brûlures au 2eeet 3e degré
consignesur la peau d’un adulte)
TRÈS CHAUD = environ 160 °F (71 °C)Environ 0,5 seconde
C = environ 150 °F (66 °C)Environ 1,5 seconde
B = environ 140 °F (60 °C)Moins de 5 secondes
Les dépôts accumulés au fond du réservoir peuvent causer
des niveaux de bruit variables et même entraîner la défaillance
du réservoir s’ils ne sont pas éliminés. Dans certaines régions
aquifères, il est possible d’enlever les dépôts en retirant environ
un gallon d’eau du chauffe-eau, une fois par mois, par le robinet
de vidange.
Inspection du système de ventilation
Inspection du brûleur
Les dégâts causés par l’inondation d’un chauffe-eau ne sont
pas toujours immédiatement visibles et décelables.
Cependant, après un certain temps, la détérioration
progressive du chauffe-eau peut causer des BLESSURES
GRAVES OU MORTELLES, ET DES DOMMAGES MATÉRIELS.
Si un chauffe-eau a été inondé, communiquer avec le
détaillant Maytag où l’appareil a été acheté ou avec le service
à la clientèle Maytag, au 1 800 788-8899, pour obtenir le nom
d’un agent de service agréé et faire remplacer le chauffeeau. Ne pas tenter de le réparer! Il faut le remplacer.
Au moins une fois l’an, inspecter visuellement le brûleur
principal et celui de la veilleuse (fig. 24).
Vérifier si les brûleurs sont encrassés par la suie. La présence
de suie est anormale et nuit à la combustion.
La formation de suie indique un défaut qui doit être corrigé
avant la remise en marche du chauffe-eau. Le cas échéant,
fermer l’arrivée de gaz du chauffe-eau et ne la rouvrir qu’une
fois les réparations nécessaires exécutées. Toute négligence
à corriger la cause de cet encrassement entraîne des risques
d’incendie pouvant provoquer des blessures graves ou
mortelles, et des dommages matériels.
GAZ NATUREL
Inspecter visuellement le système de ventilation au moins une
fois par an, en cherchant la présence :
• D’obstructions pouvant gêner la ventilation. L’air de ventilation et l’air de combustion doivent circuler librement.
• De dommages ou de détériorations pouvant gêner la ventilation ou provoquer des fuites de produits de combustion.
• De fragments de rouille autour du sommet du chauffe-eau.
S’assurer que la tuyauterie de ventilation est raccordée de façon
appropriée, de manière à éliminer les risques de fuite de gaz
de combustion susceptibles d’entraîner la mort par asphyxie.
Un système de ventilation obstrué ou défectueux peut présenter
de graves risques pour la santé et causer l’asphyxie.
La présence de vapeurs chimiques dans l’air de combustion
peut entraîner la corrosion du système de ventilation et
d’évacuation des gaz de combustion. Les propulseurs
d’aérosol, les solvants de nettoyage, les réfrigérants pour
réfrigérateurs et climatiseurs, les produits chimiques pour
piscines, le chlorure de calcium, le chlorure de sodium, les
cires, les agents de blanchiment et les produits chimiques
industriels peuvent provoquer une telle corrosion.
Si l’inspection du système de ventilation révèle un encrassement
par la suie ou une détérioration, c’est qu’il y a un défaut.
Communiquer avec le service à la clientèle Maytag, au
1 800 788-8899, pour obtenir le nom d’un agent de service agréé,
ou avec le fournisseur de gaz, afin de faire corriger le défaut et
nettoyer ou remplacer le tuyau d’évacuation des gaz et le système
de ventilation avant de remettre le chauffe-eau en marche.
PROPANE
FIGURE 24
Nettoyage du brûleur
Si l’inspection du brûleur révèle qu’un nettoyage est
nécessaire, enfoncer légèrement le bouton d’admission du
gaz, puis le tourner à droite ( ) jusqu’à la position OFF.
REMARQUE : Ce bouton ne peut être tourné de la position
PILOT à la position OFF que s’il est légèrement enfoncé. NE
PAS LE FORCER.
Les dépôts sur le brûleur ou autour de celui-ci peuvent être
enlevés à l’aide d’un boyau d’aspirateur passé avec précaution
par la porte d’accès du chauffe-eau. Si le brûleur doit être retiré
pour être nettoyé, communiquer avec le service à la clientèle
22
Page 55
Maytag au 1 800 788-8899 afin qu’un agent de service agréé
retire le brûleur, le nettoie et corrige le défaut qui est à
l’origine de l’encrassement.
Fonctionnement de la soupape de décharge
à sécurité thermique
Entretien courant
Passer l’aspirateur autour de la base du chauffe-eau pour
éliminer la poussière, la saleté et la peluche.
VÉRIFIER L’EMPLACEMENT DU CHAUFFE-EAU : Pour assurer
une ventilation et un apport d’air de combustion adéquats, les
dégagements prescrits autour du chauffe-eau doivent être
respectés. Voir la section « Points à considérer dans le choix
de l’emplacement ». Pour éliminer les risques d’incendie, tenir
à l’écart du chauffe-eau tout matériau combustible (vêtements,
produits de nettoyage, liquides inflammables, etc.).
Inspection de la tige d’anode
La soupape de décharge doit être ouverte manuellement au
moins une fois par an.
Avant l’ouverture manuelle de la soupape, s’assurer que
personne ne se trouve devant la sortie de la conduite
d’évacuation ou à proximité et que l’eau très chaude s’écoulant
de la soupape ne causera pas de dégâts matériels (fig. 25).
FIGURE 25
Si la soupape de décharge ne revient pas à sa position initiale
après l’ouverture manuelle et qu’elle continue de laisser
s’écouler de l’eau, fermer immédiatement le robinet d’eau
froide à l’entrée du chauffe-eau, vidanger le chauffe-eau
conformément aux instructions ci-dessous et remplacer la
soupape par une soupape neuve.
La tige d’anode sert à protéger le réservoir contre la corrosion.
La plupart des réservoirs d’eau chaude en sont munis. Cette
tige, une fois immergée dans l’eau, se consume progressivement pour protéger le réservoir. Au lieu de corroder le
réservoir, les ions de l’eau attaquent la tige d’anode et la
consument. Le goût et la couleur de l’eau ne sont pas affectés.
La tige d’anode doit être maintenue en bonne condition pour
que le réservoir reste en bon état.
Le degré de détérioration de la tige d’anode dépend de la
conductivité plutôt que de la composition de l’eau. Une tige
d’anode corrodée ou piquée révèle une eau à forte conductivité;
elle doit être vérifiée et remplacée plus souvent qu’une tige
d’anode apparemment intacte. Le remplacement de la tige
d’anode lorsqu’elle est usée prolongera la durée de vie du
chauffe-eau. L’inspection de la tige d’anode doit être faite par
un technicien qualifié L’inspection doit être faite au moins une
fois par an après l’expiration de la garantie.
Si la soupape de décharge suinte ou qu’elle s’ouvre
périodiquement, il s’agit probablement d’un problème de
dilatation thermique. Il est possible qu’un clapet antiretour soit
installé entre la canalisation publique et l’entrée du chauffeeau ou incorporé au compteur d’eau. Pour plus de détails,
consulter le service à la clientèle Maytag, au 1 800 788-8899.
Ne jamais obturer la soupape de décharge.
Vidange
Par temps de gel, vidanger le chauffe-eau s’il doit être mis
hors service. Un nettoyage et une vidange périodiques peuvent
aussi s’avérer nécessaires en cas d’accumulation excessive
de dépôts dans le réservoir.
23
Page 56
• Tourner le bouton d’admission du gaz à la position OFF.
• FERMER le robinet d’entrée d’eau froide du chauffe-eau.
• OUVRIR un robinet d’eau chaude proche du chauffe-eau et
le laisser ouvert pour permettre la vidange.
• Raccorder un tuyau au robinet de vidange et le faire courir
jusqu’à un drain adéquat.
• OUVRIR le robinet de vidange du chauffe-eau pour vider le
réservoir.
NOTA : Si le chauffe-eau doit être maintenu hors service
pour une période prolongée, laisser le robinet de vidange
ouvert et le tuyau raccordé afin que l’eau puisse être
évacuée vers le drain.
• FERMER le robinet de vidange.
• Suivre les instructions de la section « Remplissage du
chauffe-eau ».
• Suivre les directives d’allumage pour remettre le chauffeeau en service.
Remplacement de la rondelle du robinet
de vidange
(Pour certains modèles dotés d’un robinet de vidange en
plastique, fig. 26)
NOTA : Pour la commande de pièces de remplacement, voir
la liste des pièces de rechange dans le présent manuel.
• Fermer l’entrée de gaz du chauffe-eau.
• Suivre les instructions de vidange.
• En le tournant vers la gauche (
capuchon hexagonal situé sous la manette à vis du robinet
de vidange.
), desserrer et enlever le
• Retirer et remplacer la rondelle.
• Remettre en place la manette à vis et le capuchon hexagonal
et serrer avec une clé. NE PAS SERRER TROP FORT.
• Suivre les instructions de la section « Remplissage du
chauffe-eau ».
• Vérifier s’il y a des fuites.
• Suivre les directives d’allumage pour remettre le chauffeeau en service.
FIGURE 26
Service
Avant d’appeler un technicien pour des réparations, lire d’abord
les sections « Situations pouvant se produire à la mise en
service » et « Conditions de fonctionnement » du guide de
dépannage du manuel.
Si un problème persiste ou en cas de doute sur le bon
fonctionnement du chauffe-eau, demander au service à la
clientèle Maytag de vérifier l’appareil.
Appeler le service à la clientèle Maytag, au 1 800 788-8899,
pour obtenir le nom d’un agent de service agréé.
DÉPANNAGE
Situations pouvant se produire à la mise
en service
Fonctionnement du coupe-tirage
Pour vérifier le fonctionnement du coupe-tirage, effectuer un
test sous dépressurisation maximale du bâtiment. Toutes les
portes et les fenêtres étant fermées et tous les équipements
de traitement de l’air et ventilateurs d’évacuation (chaudières,
sécheuses, hottes aspirantes et ventilateurs de salle de bain,
etc.) étant en marche, allumer une allumette et vérifier que la
flamme est attirée par le coupe-tirage lorsque le brûleur est en
marche. Si la flamme n’est pas attirée vers le coupe-tirage,
arrêter le chauffe-eau et apporter les modifications nécessaires
au circuit d’alimentation d’air pour corriger la situation.
Condensation
Chaque fois qu’on remplit le chauffe-eau d’eau froide et que le
brûleur est allumé, de la condensation se forme. Le chauffe-eau
peut sembler présenter une fuite d’eau alors qu’il s’agit en fait d’eau
de condensation. Ce phénomène se produit habituellement :
• Au remplissage d’un chauffe-eau neuf.
• Quand il y a production de vapeur d’eau sous l’effet de la
combustion du gaz, surtout dans le cas de chauffe-eau à
haut rendement qui dégagent des gaz de combustion dont
la température est plus basse.
• Après l’utilisation d’une grande quantité d’eau sur une
courte période, lorsque l’eau de remplissage du réservoir
est très froide.
L’humidité contenue dans les produits de combustion se
condense sur la surface plus froide du réservoir et forme des
gouttes d’eau qui peuvent tomber sur le brûleur ou sur d’autres
surfaces chaudes en produisant un bruit de friture ou un
grésillement.
Si la condensation est excessive, l’eau qui s’écoule le long du
conduit d’évacuation des gaz de combustion et qui tombe sur
le brûleur principal peut même éteindre la veilleuse.
La quantité d’eau de condensation produite et son apparition
soudaine peuvent faire croire à une fuite du réservoir.
Cependant, cette condition disparaît dès que l’eau atteint une
température suffisante dans le réservoir (après une ou
deux heures environ).
Il ne faut donc pas conclure que le chauffe-eau fuit avant que
l’eau ait eu le temps de se réchauffer.
Un chauffe-eau de capacité insuffisante peut produire plus de
condensation. La capacité du chauffe-eau doit être choisie
en fonction des besoins en eau chaude des habitants, y
24
Page 57
compris pour les lave-vaisselle, les lessiveuses et les
douches.
On remarque souvent une condensation excessive pendant
l’hiver et au début du printemps quand la température de l’eau
froide est la plus basse.
Une ventilation adéquate est essentielle pour que le chauffeeau puisse fonctionner normalement et pour assurer l’évacuation efficace des produits de combustion et de la vapeur d’eau.
Fumée et odeur
À la première mise en service du chauffe-eau, il n’est pas rare
de constater le dégagement d’une petite quantité de fumée et
d’une odeur. Produits en raison de la combustion de l’huile
qui protège certaines pièces métalliques, ces effets
disparaissent rapidement.
Dilatation thermique
Pendant les périodes d’échauffement et de refroidissement,
la condensation cause un grésillement et un bruit de craquement dans la région du brûleur. Ces bruits sont considérés
comme normaux. Voir la section « Condensation ».
Conditions de fonctionnement
Eau malodorante
Chaque chauffe-eau comporte au moins une tige d’anode (voir
la section « Liste des pièces de rechange ») pour protéger le
réservoir contre la corrosion. Selon la composition de l’eau,
une réaction chimique peut se produire entre l’eau et la tige
d’anode. La plainte la plus fréquente associée à la tige d’anode
est le dégagement d’une odeur d’œufs pourris. Cette odeur
provient de l’hydrogène sulfuré dissout dans l’eau. Pour que
cette odeur se développe, il faut que les quatre conditions
suivantes soient remplies simultanément :
• forte concentration de sulfate dans l’eau d’alimentation;
• peu ou pas d’oxygène dissout dans l’eau;
• prolifération dans le chauffe-eau d’une bactérie réductrice
du sulfate, non toxique pour l’être humain;
• excès d’hydrogène actif dans le réservoir causé par l’action
anticorrosion de l’anode.
Pour remédier aux effets des surpressions, des coupures
fréquentes, des coups de bélier, etc., le réseau de distribution
d’eau peut avoir été équipé de dispositifs de protection tels
que détendeurs de pression, clapets antiretour et dispositifs
antirefoulement entre la canalisation publique et l’entrée du
chauffe-eau. Si ces dispositifs ne comportent pas de dérivation
interne et si aucune mesure corrective n’est prise le cas échéant,
le système d’alimentation en eau chaude risque de se
transformer en circuit fermé. Les systèmes en circuit fermé ne
permettent pas d’absorber la surpression créée par la dilatation
de l’eau lorsque la température augmente.
Lorsqu’elle est chauffée, l’eau du réservoir se dilate, ce qui
augmente la pression dans le système d’alimentation. Dès
que la pression d’ouverture de la soupape de décharge à
sécurité thermique est atteinte, la soupape limite automatiquement la surpression. Cependant, il faut se rappeler que la
soupape de décharge n’a pas pour rôle de limiter en
permanence la surpression causée par la dilatation
thermique de l’eau. En fait, une telle situation est inacceptable
et doit être corrigée.
Il est recommandé que tous les dispositifs de protection
pouvant avoir pour effet de « fermer » le système soient munis
d’une dérivation ou que le système soit équipé d’un réservoir
d’expansion ou d’un dispositif de décharge capable de limiter
la surpression. On peut commander un tel réservoir auprès
du service à la clientèle Maytag, au 1 800 788-8899. Pour obtenir
de l’assistance relativement à cette situation, communiquer
avec l’inspecteur de plomberie local, le service public des eaux
ou le service à la clientèle Maytag, au 1 800 788-8899.
Bruits étranges
Certains bruits produits par la dilatation et la contraction de
pièces métalliques pendant les cycles de réchauffement et de
refroidissement n’indiquent pas la présence d’une situation
nuisible ou dangereuse.
Pour éliminer ou réduire cette odeur désagréable, on peut,
dans certains modèles de chauffe-eau, remplacer l’anode (ou
les anodes) par une anode en matériau moins actif, puis traiter
au chlore le réservoir et toutes les conduites d’eau chaude.
Pour plus de renseignements concernant le kit de remplacement d’anode et le traitement au chlore, communiquer
avec le service à la clientèle Maytag, au 1 800 788-8899.
Si l’odeur désagréable persiste après le remplacement de
l’anode et le traitement au chlore, il ne reste plus qu’à considérer
le traitement au chlore ou l’aération du système de distribution
d’eau en amont du chauffe-eau.
Ne pas retirer l’anode et laisser le réservoir sans protection,
au risque d’annuler toutes les garanties couvrant le
chauffe-eau.
Présence d’air dans les robinets d’eau chaude
HYDROGÈNE : Il peut y avoir formation d’hydrogène dans un
système d’alimentation en eau chaude non utilisé pendant
une période relativement longue (en général deux semaines
ou plus). L’hydrogène est un gaz très inflammable et explosif.
Pour prévenir les risques d’accidents, il est recommandé
d’ouvrir le robinet d’eau chaude le plus éloigné du chauffeeau quelques minutes avant de mettre en marche les
appareils électriques (lave-vaisselle, lessiveuse, etc.)
raccordés au système d’eau chaude. S’il y a de l’hydrogène
25
Page 58
dans le circuit, un bruit inhabituel semblable au bruit de l’air
qui s’échappe d’un tuyau peut se faire entendre lors de
l’ouverture du robinet. Ne pas fumer ni approcher de flamme
nue du robinet pendant l’ouverture.
Système d’arrêt automatique en cas
de température excessive de l’eau
Le chauffe-eau est équipé d’un système de coupure automatique du gaz qui se déclenche quand la température de
l’eau dépasse la limite prédéfinie. Ce limiteur de température
est intégré au régulateur de gaz. S’il se déclenche, il ne peut
pas être réenclenché. Dans ce cas, le régulateur de gaz doit
être remplacé au complet. Fermer l’arrivée de gaz principale
du chauffe-eau. Communiquer avec le service à la clientèle
Maytag, au 1 800 788-8899, pour obtenir le nom d’un agent
de service agréé.
Points de vérification des fuites
G. * Fuite possible du robinet de vidange au niveau du raccord
avec le réservoir.
H. Les produits de combustion contiennent de la vapeur d’eau
qui peut se condenser sur les surfaces plus froides du
réservoir. Des gouttes d’eau se forment et tombent sur le
brûleur ou sur le sol. Cet effet se produit couramment au
moment de la première mise en service ou lorsque l’eau
d’alimentation est très froide.
I. La présence d’eau au bas du chauffe-eau ou sur le sol peut
être due à de la condensation, à un raccord mal serré ou à
la soupape de décharge à sécurité thermique. NE PAS
REMPLACER le chauffe-eau avant d’avoir fait une inspection complète de tous les points de fuite possibles et tenté
toutes les mesures correctives nécessaires.
Il faut aussi vérifier si la fuite d’eau observée provient d’autres
appareils ou d’autres conduites d’eau ou est due à un
suintement du sol.
* Pour contrôler le point où la partie filetée d’un raccord pénètre
dans le réservoir, insérer un coton-tige entre l’ouverture de
la chemise et le raccord. Si le coton est humide, suivre
les instructions de vidange de la section « Entretien et
réparation », puis retirer le raccord. Mettre de la pâte à joint
ou du ruban de téflon sur les filets et remettre le raccord en
place. Pour terminer, suivre les instructions de remplissage
du chauffe-eau à la section « Choix de l’emplacement du
chauffe-eau et installation ».
Lire d’abord le présent manuel. Ensuite, avant de vérifier le
chauffe-eau, s’assurer que l’entrée de gaz est fermée et ne
l’ouvrir qu’une fois le réservoir entièrement rempli d’eau.
Ne jamais utiliser le chauffe-eau s’il n’est pas entièrement
rempli d’eau. Pour ne pas endommager le réservoir, le
chauffe-eau doit être entièrement rempli. Avant d’ouvrir le
robinet de gaz, l’eau doit s’écouler des robinets d’eau
chaude (fig. 28).
A. Présence d’eau au niveau du coupe-tirage. Provient de la
condensation de la vapeur d’eau contenue dans les produits
de combustion. Dénote un problème dans l’évent de sortie.
Communiquer avec le service à la clientèle Maytag, au
1 800 788-8899, pour obtenir le nom d’un agent de service
agréé.
B. * Condensation observable sur les tuyaux. Normal par
temps humide; peut indiquer une fuite dans un raccord.
C. * Eau sur le raccord de la tige d’anode. Fuite possible.
D. Léger écoulement d’eau de la soupape de décharge à
sécurité thermique. Peut être causé par la dilatation
thermique de l’eau du système ou par une pression
d’alimentation d’eau élevée.
E. * Fuite possible de la soupape de décharge au niveau du
raccord avec le réservoir.
F. Un écoulement d’eau peut apparaître à la sortie du robinet
de vidange s’il est légèrement ouvert.
FIGURE 28
26
Page 59
GUIDE DE DÉPANNAGE
Le guide ci-dessous est destiné aux agents qualifiés du service à la clientèle Maytag. Au besoin, communiquer
avec le service à la clientèle Maytag, au 1 800 788-8899.
ProblèmeCauseSolution
Raccord d’eau chaude ou d’eau froide, soupapeResserrer les raccords filetés.
FUITES D’EAU
FUITES DE LA SOUPAPE DE
DÉCHARGE À SÉCURITÉ
THERMIQUE
EAU MALODORANTE
LA VEILLEUSE NE
S’ALLUME PAS
LE BRÛLEUR NE RESTE
PAS ALLUMÉ
VEILLEUSE EN PANNE
MANQUE
D’EAU CHAUDE
EAU TROP CHAUDEThermostat réglé trop haut.Voir la section « Réglage de la température ».
BRUIT DU CHAUFFE-EAUCondensation s’égouttant sur le brûleur.Voir la section « Condensation ».
GRÉSILLEMENT,
GRONDEMENT
ENCRASSEMENT
PAR LA SUIE
ODEUR DE GAZ DE
COMBUSTION
de décharge, robinet de vidange ou filetage du
thermostat non étanches.
Fuite provenant d’autres appareils ou deInspecter les appareils proches du chauffe-eau.
conduites d’eau.
Condensation des produits de combustion.Voir la section « Condensation ».
Dilatation thermique dans un circuit d’eau fermé.Installer un réservoir de dilatation thermique (NE PAS
Soupape mal assise sur son siège.Vérifier le bon fonctionnement de la soupape de
Forte concentration de sulfate ou de minérauxVidanger le chauffe-eau entièrement, le rincer et le
dans l’eau d’alimentation.remplir de nouveau.
Bactéries dans l’eau d’alimentation.Traiter au chlore ou aérer le système de distribution d’eau.
Bouton d’admission du gaz mal positionné.Voir les instructions d’allumage.
Robinet de gaz principal fermé.Ouvrir le robinet de gaz principal.
Mauvais fonctionnement du thermocouple.Remplacer la veilleuse ou le thermocouple.
Allumette loin de la veilleuseLocaliser la veilleuse et en approcher l’allumette.
Mauvais fonctionnement du thermocouple.Remplacer la veilleuse ou le thermocouple.
Commande de gaz défectueuse.Remplacer la commande de gaz.
Brûleur de la veilleuse encrassé.Nettoyer la veilleuse au complet.
Pointe du thermocouple non en contact avecInsérer le thermocouple convenablement.
la flamme de la veilleuse.
Mauvais fonctionnement du thermocouple.Remplacer la veilleuse ou le thermocouple.
Commande de gaz défectueuse.Remplacer la commande de gaz.
Chauffe-eau éteint ou thermostat fermé.Voir les instructions d’allumage.
Thermostat réglé trop bas.Voir la section « Réglage de la température ».
Chauffe-eau de capacité insuffisante.Réduire la consommation d’eau chaude.
Pression du gaz trop basse.Communiquer avec le fournisseur de gaz.
Eau anormalement froide à l’entrée.Laisser le chauffe-eau réchauffer l’eau plus longtemps.
Fuites dans les tuyaux d’eau chaude ou lesDemander à un plombier de vérifier l’installation et
appareils.de réparer les fuites.
Limiteur de température déclenché.Demander à un agent du service à la clientèle Maytag
Dépôt de matières ou de calcium au fondNettoyer le dépôt au fond du réservoir. Voir les
du réservoir.instructions de vidange à la section « Entretien ».
Mauvaise combustion.Aucun réglage possible. Demander à un agent du service
Apport d’air frais insuffisant.
Évent mal installé.Demander à un agent du service à la clientèle Maytag de
Rupture de tirage.
Mauvaise combustion.
obturer la soupape de décharge).
décharge. (NE PAS l’obturer).
de déterminer la cause du problème.
à la clientèle Maytag de déterminer la cause du problème.
déterminer la cause du problème.
27
Page 60
LISTE DES PIÈCES DE RECHANGE
CHAUFFE-EAU AU GAZ MAYTAG
No DE MODÈLE
HRX75XQRS 75 gallons au gaz naturel
HRX75CQRS 75 gallons au gaz propane
BRÛLEUR
BRÛLEUR AU PROPANE
18
4
3
21
17
2
Numéro du modèle
NoDescription de la pièceHRX75XQRSHRX75CQRS
1Tige d’anode6600110966001109
2Tête de brûleur900620066001834
3Orifice du brûleur principal - standard66001689 (#21) 66001841 (#38)
4Tube de brûleur900619966001846
9Robinet de vidange6600101566001015
10Rondelle du robinet de vidange6600102166001021
11Déflecteur de gaz de combustion6600167766001677
12Commande de gaz6600168066001773
13Porte d’accès interne6600169266001692
de compression900620166001848
18Tube de la veilleuse--------66001845
19Soupape de décharge à sécurité thermique6600168266001682
20Dispositif de verrouillage pour thermostat
Au cours de la période d’un an suivant la date d’achat au détail initial, toute pièce qui fait défaut dans des
conditions d’utilisation résidentielle normales est réparée ou remplacée sans frais.
Si le réservoir fuit, le chauffe-eau est remplacé sans frais par un chauffe-eau neuf de capacité et de qualité
les plus équivalentes possible.
Le chauffe-eau de remplacement est garanti jusqu’à la fin de la période de garantie initiale du chauffe-eau.
GARANTIE LIMITÉE VISANT LES PIÈCES
De la deuxième année à la dixième année suivant la date d’achat au détail du chauffe-eau, toute pièce
défectueuse en raison d’un défaut de matériau ou de fabrication est remplacée ou réparée sans frais, les
autres frais, dont les frais de main-d’œuvre, de déplacement et de transport, devant être acquittés par le
propriétaire.
Si le chauffe-eau fait l’objet d’un usage commercial, institutionnel, industriel ou non résidentiel, la période
de couverture ci-dessus pour les pièces avérées défectueuses en raison d’un défaut de matériau ou de
fabrication est limitée à un an suivant la date d’achat au détail initial.
Les pièces de rechange sont garanties jusqu’à la fin de la période de garantie initiale du chauffe-eau ou
pendant 12 mois à compter de la date d’achat de la pièce, selon la période la plus courte.
Cette garantie est offerte exclusivement au propriétaire initial du chauffe-eau.
GARANTIE LIMITÉE DU RÉSERVOIR CONTRE LES FUITES
De la deuxième année à la dixième année suivant la date d’achat au détail, si le réservoir fuit, le chauffe-eau
est remplacé par un chauffe-eau neuf de capacité et de qualité les plus équivalentes possible, gratuit, les
autres frais, dont les frais de main-d’œuvre, de déplacement et de transport, devant être acquittés par le
propriétaire.
Si le chauffe-eau fait l’objet d’un usage commercial, institutionnel, industriel ou non résidentiel, la période
de couverture ci-dessus pour les réservoirs avérés défectueux en raison d’un défaut de matériau ou de
fabrication est limitée à deux ans suivant la date d’achat au détail initial.
Le chauffe-eau de remplacement est garanti jusqu’à la fin de la période de garantie initiale du chauffe-eau.
Nota : La garantie complète et la garantie limitée ne s’appliquent que si le chauffe-eau est utilisé au Canada.
Cette garantie est offerte exclusivement au propriétaire initial du chauffe-eau.
POUR OBTENIR UN SERVICE EN VERTU DE LA GARANTIE
Pour connaître l’emplacement d’une entreprise de service agréée de la région, communiquer avec le détaillant
Maytag où l’appareil a été acheté ou avec le service à la clientèle Maytag, au numéro indiqué ci-dessous. Si
le service obtenu est insatisfaisant, nous vous prions de nous en informer par téléphone ou par écrit à
l’adresse suivante :
Service à la clientèle Maytag
C. P. 2370
Cleveland TN 37320-2370
États-Unis 1 800 788-8899
Dans vos communications avec le service à la clientèle Maytag, assurez-vous d’indiquer le numéro de
modèle et de série de votre appareil, le nom et l’adresse du détaillant où vous l’avez acheté ainsi que la date
d’achat.
LES CHAUFFE-EAU MAYTAG SONT FABRIQUÉS PAR STATE INDUSTRIES, INC., ASHLAND CITY, TN,
QUI EN FOURNIT LA GARANTIE. MAYTAG EST UNE MARQUE DE COMMERCE DE MAYTAG
CORPORATION, UTILISÉE SOUS LICENCE PAR STATE INDUSTRIES, INC.
32