Maytag HRX40YQRT, HRX40HART, HRX40YART, HRX50YART, HRX40HARS User Manual

...
Page 1
Series Ten
GAS W A TER HEA TER
USER’S GUIDE
FOR POTABLE WATER HEATING ONLY
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN
MANUFACTURED (MOBILE) HOMES
C3 Technology® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Model Numbers
HRX40Y ARS
HRX40HARS
HRX40Y ART HRX40HART HRX40YQRT HRX40HQRT
HRX50Y ART
HRX50HART HRX50YQRT5 HRX50HQRT5
HRX50YQRT
HRX50HQRT
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WA TER HEA TER.
PRINTED IN THE U.S.A 0405 PART NO. 184388-002
1
66001907
Page 2
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently
DANGER
W ARNING
CAUTION
hazardous situation which, if not avoided, could result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.
symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.
IMPORTANT DEFINITIONS
• Maytag Service Specialist: A Maytag Service Specialist has the equivalent to a licensed tradesman in the fields of plumbing, air
supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The Service Specialist also has a thorough understanding of this instruction manual, and is able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.
• Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.
2
Page 3
SAFETY PRECAUTIONS
3
Page 4
TABLE OF CONTENTS
SAFE INST ALLA TION, USE AND SERVICE ................................................................................................. 2
SAFETY PRECAUTIONS.............................................................................................................................. 3
TABLE OF CONTENTS ................................................................................................................................ 4
CUSTOMER RESPONSIBILITIES ................................................................................................................ 5
PRODUCT SPECIFICA TIONS...................................................................................................................... 5
ACCESSORIES AND TOOLS NEEDED...................................................................................................... 6
Accessories ............................................................................................................................................................ 6
Tools ....................................................................................................................................................................... 6
INSTRUCTIONS FOR INST ALLA TION.......................................................................................................... 7
Removing the Old Water Heater ..............................................................................................................................7
TYPICAL INST ALLA TION............................................................................................................................... 8
Get to Know Your Water Heater .............................................................................................................................. 8
Mixing Valve Usage .................................................................................................................................................9
LOCA TING THE NEW HEATER.................................................................................................................. 10
Facts to Consider About the Location ...............................................................................................................10-11
Insulation blankets ................................................................................................................................................ 11
Combustion Air and V entilation Appliances
in Unconfined Spaces............................................................................................................................................ 12
Combustion Air and V entilation Appliances
in Confined Spaces .......................................................................................................................................... 12-13
Water Piping .................................................................................................................................................... 13-14
T & P and Pipe Insulation................................................................................................................................... 14
T emperature Pressure Relief V alve.................................................................................................................... 14-15
Filling the Water Heater.................................................................................................................................... 15,16
Venting............................................................................................................................................................. 16,17
Gas Piping ....................................................................................................................................................... 17,18
Sediment Trap....................................................................................................................................................... 18
OPERATING INSTRUCTIONS ................................................................................................................ 19-20
Lighting & Operating Label .................................................................................................................................... 19
T emperature Regulation ......................................................................................................................................... 20
SERVICE AND MAINTENANCE .............................................................................................................. 21-23
T ank (Sediment) Cleaning...................................................................................................................................... 21
Venting System Inspection.................................................................................................................................... 21
Burner Inspection .................................................................................................................................................. 21
Burner Cleaning................................................................................................................................................ 21-22
Housekeeping ....................................................................................................................................................... 22
Anode Rod Inspection ........................................................................................................................................... 22
T emperature-Pressure Relief V alve Operation ........................................................................................................ 22
Draining............................................................................................................................................................ 22-23
Drain V alve Washer Replacement.......................................................................................................................... 23
Service .................................................................................................................................................................. 23
TROUBLESHOOTING ............................................................................................................................23-26
Start Up Conditions ............................................................................................................................................... 23
Draft Hood Operation .................................................................................................................................... 23
Condensation........................................................................................................................................... 23-24
Smoke / Odor ............................................................................................................................................... 24
Thermal Expansion ....................................................................................................................................... 24
Strange Sounds............................................................................................................................................ 24
Operational Conditions ..................................................................................................................................... 24-25
Smelly Odor ................................................................................................................................................. 24
“AIR” In Hot Water Faucets .......................................................................................................................... 24
High Temperature Shut Off System............................................................................................................... 25
Leakage Checkpoints............................................................................................................................................ 25
TROUBLESHOOTING GUIDE .................................................................................................................... 26
REP AIR PARTS LIST .............................................................................................................................. 27-29
NOTES....................................................................................................................................................30-31
WARRANTY ................................................................................................................................................ 32
4
Page 5
CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact a Maytag Service Specialist
at 1-800-365-0024 for recommended installers.
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association
ANSI - American National Standards Institute
NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturers Association This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).
• Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE A TTEMPTING
TO INSTALL OR OPERA TE THE WA TER HEA TER.
local codes, installations shall comply with the following: In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd., Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do not understand any portion of the instructions, call a Maytag
Service Specialist at 1-800-365-0024 for an authorized servicer.
• Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires, see figure 1 and 2.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.
• For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
• Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.
• The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of
• Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
PRODUCT SPECIFICATIONS
TANK RECOVERY MINIMUM DIMENSIONS
CAPACITY TYPE RATE GALS. VENT PIPE DIAMETER IN INCHES (mm)
IN GALS O F BT U PER HOUR INCHES INCHES HEIGHT TOP OF
MODEL NUMBER (LTRS) GAS RATE @ 90°F RISE (mm) (mm) DRAFT HOOD
HRX40YARS 40 (151) NATURAL 40,000 41.0 3” (76) or 4” (102) 20” (508) 51 5/8” (1,311) HRX40HARS 40 (151) PROP ANE 37,000 41.0 3” (76) or 4” (102) 20” (508) 51 5/8” (1,311) HRX40Y ART 38 (144) NATURAL 40,000 39.0 3” (76) or 4” (102) 18 1/2” (470) 57 5/8” (1,464) HRX40HART 38 (144) PROPANE 37,000 39.0 3” (76) or 4” (102) 18 1/2” (470) 57 5/8” (1,464) HRX40YQRT 38 (144) N ATURAL 50,000 48.0 4” (102) 20 1/4” (514) 58 1/2” (1,486) HRX40HQRT 38 (144) PROP ANE 47,000 48.0 4” (102) 20 1/4” (514) 58 1/2” (1,486) HRX50Y ART 50 (189) NATURAL 40,000 41.0 3” (76) or 4” (102) 20 1/4” (514) 60 7/8” (1,546)
HRX50HART 50 (189) PROPANE 37,000 39.0 3” (76) or 4” (102) 20 1/4” (514) 60 7/8” (1,546) HRX50YQRT5 50 (189) NATURAL 65,000 67.0 4” (102) 22” (559) 65” (1,651) HRX50HQRT5 50 (189) PROPANE 55,000 57.0 4” (102) 22” (559) 65” (1,651)
HRX50YQRT 48 (182) N ATURAL 50,000 51.0 4” (102) 20 1/4" (514) 60 7/8” (1,546)
HRX50HQRT 48 (182) PROP ANE 45,000 51.0 4” (102) 20 1/4" (514) 60 7/8” (1,546)
* Adding suffix “D” denotes high altitude. High altitude models have a B.T.U./Recovery Rate 10% less than shown.
5
Page 6
ACCESSORIES AND TOOLS NEEDED
Accessories
T o simplify the inst allation Maytag has available the installation p art s shown below. You may or may not need all of these accessories depending on your type of installation. Call a Maytag Service Specialist at 1-800-365-0024 for an authorized installer.
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLON (7.6 LITERS), Part No. 9850048 AND 5 GALLON (18.9 LITERS), Part No. 9850049 CAPACITY.
Tools
You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local hardware store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Teflon Tape
DRILL
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
TIN SNIPS
DRAIN PANS AVAILABLE IN 22” (559 mm) DIAMETER (PART NO. 9001609) FOR WATER HEATERS HAVING A DIAMETER 20” (508 mm) OR LESS, 24” (610mm) DIAMETER (PART NO. 9002769) FOR WA TER HEATERS HA VING A DIAMETER 22” (559 mm) OR LESS AND 28” (711 mm) DIAMETER (PART NO. 9001608) FOR WATER HEATERS HAVING A DIAMETER 26” (660 mm) OR LESS.
Additional Tools Needed When Sweat Soldering
• Tubing Cutters or Hacksaw
• Propane Tank
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
PROPAN E
TUBING CUTTER
TORCH
ROLL OF TEFLON
TAPE (USE ONL Y ON
WA TER HEA TER
CONNECTIONS)
GARDEN HOSE
6 FOOT TA PE
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WA TER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
6
HACKSAW
ROLL OF
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
SOLDER
FLUX
Page 7
INSTRUCTIONS FOR INSTALLATION
Removing the Old Water Heater
FIGURE 1.
4. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person, see Figures 1 and 4.
5. Disconnect the vent pipe from the draft hood where they connect to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater has the draft hood which must be used for proper operation.
6. If you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature­pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed, see Figure 5.
FIGURE 4.
1. Turn “OFF” the gas supply to the water heater.
If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 1 and 2.
2. Turn “OFF” the water supply to the water heater at the water shut-off valve or water meter. Some installations require that the water be turned off to the entire house, see Figures 1 and 3.
3. Check again to make sure the gas supply is “OFF” to the water heater. Then disconnect the gas supply connection from the gas control valve.
FIGURE 2.
FIGURE 3.
FIGURE 5.
If you have galvanized pipe to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater . These pieces should be saved since they may be needed when reconnecting the new water heater. Disconnect the temperate-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining, see Figure 6.
7
FIGURE 6.
Page 8
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe B Draft Hood C Anode D Hot Water Outlet
E Outlet
F Flexible Water Connections G Gas Supply H Manual Gas Shut-off Valve
I Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
J Drip Leg (Sediment T rap)
K Inner Door
L Outer door
M Union
N Inlet Water Shut-off V alve O Cold Water Inlet P Inlet Dip Tube Q Temperature-Pressure Relief Valve R Rating Plate
S Flue Baffle
T Thermostat U Drain Valve V Pilot and Main Burner
W Flue
X Drain Pan
Y Thermostat Shield (optional)
Z Piezo Igniter
AA Air Intake Screen
(T) THERMOSTA T
* ALL PIPING MA TERIALS TO BE
SUPPLIED BY CUSTOMERS.
** CLOSED WATER SYSTEMS ARE THOSE WITH
BACK FLOW PREVENTION DEVICES INSTALLED IN THE INLET WATER SERVICE LINE.
Y
THERMOSTAT
SHIELD
(OPTIONAL)
(V) PILOT & MAIN BURNER
FIGURE 7.
8
Page 9
TYPICAL INSTALLATION
MIXING V ALVE USAGE
FIGURE 8.
This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and is considered suitable for:
Water (Potable) Heating: All models are considered suitable for water (potable) heating.
HOTTER WA TER CAN SCALD: Water heaters are intended to produce hot water . Water heated
to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/ mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a *Mixing Valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at a plumbing supply distributor, see Figure 8. Valves for reducing point of use, temperature by mixing cold and hot water are also available. Consult a Maytag Service Specialist at 1-800-365-0024. Follow mixing valve manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual, see Figures 22 and 23 on page 20.
9
Page 10
LOCATING THE NEW WATER HEATER
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:
• Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible.
• Selected location must provide adequate clearances for servicing and proper operation of the water heater.
Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local distributor. Such a drain pan must have a minimum length and width of at least 2 inches (51 mm) greater that the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow.
Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:
• Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.
INST ALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances (such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water heater’s pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area. Even though this water heater is a flammable vapors ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
• Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.
• Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.
• Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.
This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.
10
Page 11
Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater, see Figure 9.
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas.
Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
Insulation Blankets
Insulation blankets available to the general public for external use on gas water heaters are not necessary with Maytag products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Maytag water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.
FIGURE 9.
• Install water heater in accordance with the instruction manual and NFPA 54.
• To avoid injury, combustion and ventilation air must be taken from outdoors.
• Do not place chemical vapor emitting products near water heater.
A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air . If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.
• Do not obstruct water heater air intake with insulating blanket.
• Gas and carbon monoxide detectors are available.
• Install water heater in accordance with the instruction manual.
WARNING
Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 7 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.
Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.
Do not cover the outer door, thermostat or temperature & pressure relief valve.
FIGURE 10.
Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.
Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.
Do obtain new warning and instruction labels from Maytag for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.
11
Page 12
Combustion Air and V entilation for Appliances Located in Unconfined Spaces
UNCONFINED SP ACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier , etc.), additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Located in Confined Spaces.
3
per kW) of the
Combustion Air and V entilation for Appliances Located in Confined Spaces
top and one commencing within 12 inches (30 cm) from the bottom of the enclosure. The openings shall communicate directly , or by ducts, with the outdoors or sp aces (crawl or attic) that freely communicate with the outdoors.
CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figure 10 on page 11 and Figure 11 below)
The confined space shall be provided with two permanent
openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in the combined space shall be considered in making this determination. Each opening shall have a minimum free area of one square inch per 1,000 Btu per hour (22 cm
2
/kW) of the total input rating of all gas utilization equipment in the confined space, but not less than 100 square inches (645 cm
2
). One opening shall commence within 12 inches (30 cm) of the top and one commencing within 12 inches (30 cm) of the bottom of the enclosures.
FIGURE 12.
• When directly communicating with the outdoors, each opening shall have a minimum free area of 1 square inch per 4,000 Btu per hour (5.5 cm
2
/kW) of total input rating of all equipment in the
enclosure, see Figure 12.
• When communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 BTU per hour (5.5 cm
2
/kW) of total input rating of all equipment in the enclosure, see Figure 13.
FIGURE 11.
B. ALL AIR FROM OUTDOORS: (See Figures 12, 13 and 14)
The confined space shall be provided with two permanent
openings, one commencing within 12 inches (30 cm) of the
FIGURE 13.
• When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (11 cm
2
/kW) of total input rating of all equipment in the enclosure, see Figure 14.
• When ducts are used, they shall be of the same cross­sectional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular air ducts shall not be less than 3 inches (76.2 mm), see Figure 14.
12
Page 13
FIGURE 14.
• Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.
satisfies your hot water needs, a means such as a *mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at a plumbing supply distributor, see Figure 8 on p age 9 and Figure 15 below. Valves for reducing point of use temperature by mixing cold and hot water are also available.
Specialist at 1-800-365-0024. Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual.
Consult a Maytag Service
FIGURE 15.
• Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.
Water Piping
HOTTER WA TER CAN SCALD: Water heaters are intended to produce hot water . Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly , children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that
This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.
Toxic chemicals, such as those used for boiler treatment shall not be introduced into this system.
Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable
condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank to relieve the pressure built by thermal expansion in the water system. Refer to the Thermal Expansion section under Troubleshooting
Guide or contact local plumbing authority or call a Maytag Service Specialist at 1-800-365-0024 for an authorized installer on how to control this situation.
13
Page 14
NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe.
NOTE: The secondary anode rod/hot outlet nipple and the cold inlet nipple are packaged separately with the water heater. The above p arts must be installed in the appropriate HOT and COLD water connections.
Figure 16 shows the typical attachment of the water piping to the water heater. The water heater is equipped with 3/4” NPT water connections for 40 and 50 gallon models.
• Look at the top of the water heater. The cold water inlet is marked “COLD”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using standard pipe fittings, connect the cold water pipe to the cold water inlet of the water heater.
NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater.
T & P V alve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from carton.
FIGURE 16.
NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It will harm the dip tube and damage the tank.
FIGURE 16A.
Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater.
Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.
Secure all insulation using tape.
T emperature-Pressure Relief Valve
• Temperature-pressure relief valve must comply with ANSI Z21.22 and ASME code.
• Properly sized temperature-relief valve must be installed in opening provided.
• Can result in overheating and excessive tank pressure.
• Can cause serious injury or death.
This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer.
• Look at the top cover of the water heater. The water outlet is marked “HOT”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using standard pipe fittings, connect the hot water pipe to the hot water outlet on the water heater.
The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief Valves and Automatic Gas Shut-off Devices for Hot W ater Supply Systems, ANSI Z21.22 and the code requirements of ASME.
14
Page 15
If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035 kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.
For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.
The Discharge Pipe:
• Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.
The temperature-pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor. Be certain that no cont act is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve, see Figure 17.
No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.
• Shall terminate at an adequate drain.
• Shall not have any valve between the relief valve and tank.
The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.
FIGURE 17.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
Filling the Water Heater
Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. W ater must flow from the hot water faucet before turning “ON” gas to the water heater.
To fill the water heater with water:
• Close the water heater drain valve by turning the handle to
15
Page 16
the right (clockwise). The drain valve is on the lower front of the water heater.
• Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the water heater is in use.
• To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.
• Check all water piping and connections for leaks. Repair as needed.
Venting
Specialist at 1-800-365-0024 or gas supplier to aid you in
determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223.1/NFP A 54.
Periodically check the venting system for signs of obstruction or deterioration and replace if needed.
The combustion and ventilation air flow must not be obstructed. The water heater with draft hood installed must be connected
to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.
VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.
Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult your Maytag Customer Service Center or the local gas supplier for further information.
• For proper draft hood attachment, the draft hood legs may be angled slightly inward.
• Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure two legs to top with sheet metal screws.
• Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw, see Figure 18.
Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.
To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater. Consult a Maytag Service Specialist at
1-800-365-0024 or gas supplier if any such changes are planned.
For proper venting in certain installations, a larger diameter vent pipe may be necessary. Consult a Maytag Service
FIGURE 18.
The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter), see Figure 19.
FIGURE 19.
All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.
Vent pipes must be secured at each joint with sheet metal screws.
16
Page 17
There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.
Failure to have required clearances between vent piping and combustible material will result in a fire hazard.
Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.
plate is for the purpose of input adjustment. valve is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.
If the main gas line Shut-off serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is complete.
A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA 54 and your gas supplier concerning pipe size.
There must be:
• A readily accessible manual shut off valve in the gas supply line serving the water heater, and
• A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.
• A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.
Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.
The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.
If the gas control
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
Gas Piping
Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (2.6kPa) for natural and propane gas (L.P.) gas. The minimum inlet gas pressure listed on the rating
If a standard model is installed above 3,300 feet (1,006 m) or a high altitude model is installed above 5,500 feet (1,676 m) the input rating should be reduced at the rate of 4 percent for each 1,000 feet (
of the burner orifice in accordance with National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact a Maytag Service Specialist
at 1-800-365-0024 or your local gas supplier or call for further information.
Failure to replace the standard orifice with a high altitude orifice when installed at elevations above 3,300 feet (1,006 m) or above 5,500 feet (1,676 m) for high altitude model could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious injury or death. Contact
Specialist at 1-800-365-0024
any specific changes which may be required in your area.
17
305 m ) above sea level which requires replacement
a Maytag Service
or your local gas supplier for
Page 18
Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum (Propane [L.P.]) gases.
The appliance and its gas connection must be leak tested before placing the appliance in operation.
The appliance and its individual Shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5kPa). It shall be isolated from the gas supply piping system by closing its individual manual Shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pound per square inch (3.5kPa).
Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the Gas Piping section. Refer to the current edition of th
ANSI Z223.1/NFP A 54.
A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation, shown in Figures 20 and 21.
e National Fuel Gas Code,
Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods, shown in Figures 20 and 21.
Sediment Traps
• Contaminants in gas lines can cause fire or explosion.
• Clean all gas piping before
installation.
• Install drip leg in accordance
with NFP A 54.
FIGURE 20. GAS PIPING WITH FLEXIBLE CONNECTOR.
FIGURE 21. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.
18
Page 19
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WA TER AND AIR PURGED FROM ALL LINES.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
• If you cannot reach your gas supplier, call the fire department.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHA T TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
LIGHTING INSTRUCTIONS
TOP KNOB
GAS CONTROL
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting (PILOT LIGHTING).
Turn thermostat dial fully clockwise
3. Push the gas control knob down slightly and turn clockwise
to “OFF”, SEE FIGURE “A”. NOTE: Knob CANNOT be turned from “PILOT” to “OFF” unless it is pushed down slightly. Do not force.
4. Remove the outer burner door located below the gas control.
5. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information
above on this label. If you don’t smell gas, go to next step.
6. This unit is equipped with a push button pilot igniter, which is used to light the pilot. Locate the igniter on the gas control.
7. Turn gas control knob counterclockwise SEE FIGURE “B”.
8. The pilot is located on the right side of the burner. It can be located by looking through the glass view port while pressing the piezo igniter button several times. Look for a spark at the pilot location, FIGURE “D”.
until it stops.
to “PILOT”,
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician . Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately contact a qualified installer or service agency to replace the flooded water heater. Do not attempt to repair the unit! It must be replaced!
FIGURE “D”
9. Once the pilot has been found, push the gas knob all the way down. Immediately press the pilot igniter button rapidly (4) to (5) times. If the pilot will not light, repeat step (3) through (9).
10. Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out, repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light.
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob clockwise technician or gas supplier. SEE FIGURE “A”.
1 1. Once the pilot flame is established replace the outer burner
door.
12. At arms length away, turn gas control knob counterclockwise
13. Set thermostat to desired setting.
DANGER: Hotter water increases the risk o f scald injury. Consult the instruction manual before changing temperature.
to “OFF” and call your service
to “ON”. SEE FIGURE “C”.
TO TURN OFF GAS TO APPLIANCE
1. Set thermostat to the lowest setting (PILOT LIGHTING).
2. Push gas control knob down slightly and turn clockwise to “OFF”. Do not force. SEE FIGURE “A”.
19
Page 20
Temperature Regulation
Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30F° (16.7 C°) higher or lower at the point of use such as, bathtubs, showers, sink, etc.
installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual, see Figures 22 and 23.
Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.
Any water heater’s intended purpose is to heat water. Hot water is needed for cleansing, cleaning, and sanitizing (bodies, dishes, clothing). Untempered hot water can present a scald hazard. Depending on the time element, and the people involved (adults, children, elderly , infirm, etc.) scalding may occur at different temperatures.
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water heater . Mixing valves are available at a plumbing supply distributor, see Figure 8 on page 9 and Figure 15 on page 13. Valves for reducing point of use temperature by mixing cold and hot water are also available.
Consult a Maytag Service Specialist at 1-800-365-0024. Follow manufacturer’s instructions for
NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers.
The thermostat of this water heater has been factory set at its lowest position (PILOT LIGHTING). It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury. The mark (
) indicative of approximately 120°F (49°C) is preferred starting point. Some states have a requirement for a lower setting.
Turn the water temperature dial clockwise ( ) to decrease the temperature, or counterclockwise ( ) to increase the temperature.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.
FIGURE 22.
Temperature Time to Produce 2nd & 3rd
Settings Degree Burns on Adult Skin
VERY HOT= approx. 160°F (71°C)
C = approx. 150°F (66°C) About 1-1/2 seconds B = approx. 140°F (60°C) Less than 5 seconds A = approx. 130°F (54°C) About 30 seconds
= approx. 120°F (49°C) More than 5 minutes
LOW = approx. 80°F (27°C) - - - - - - - - - - - - - - - -
FIGURE 23.
About 1/2 second
20
Page 21
SERVICE AND MAINTENANCE
Tank (Sediment) Cleaning
Sediment build-up on the tank bottom may create varying amount of noise, if left in the tank will cause permanent tank failure. In some water areas, sediment can be removed by draining off approximately one gallon of water each month.
Vent System Inspection
• Flue gases may escape if vent pipe is not connected.
• Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
• Do not store corrosive chemicals in vicinity of water heater.
• Chemical corrosion of flue and vent system can cause serious injury or death
Burner Inspection
Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions
can cause DEATH, SERIOUS BODIL Y INJURY , OR PROPER TY DAMAGE. Contact the Maytag dealer from whom the appliance was purchased or call a Maytag Service Specialist at
1-800-365-0024 for an authorized servicer to replace a flooded water heater. Do not attempt to
must be replaced!
At least once a year a visual inspection should be made of the main burner and pilot burner, see Figure 24.
Y ou should check for sooting. Soot is not normal and will imp air proper combustion.
Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.
repair the unit! It
which
At least once a year a visual inspection should be made of the venting system. You should look for:
• Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.
• Damage or deterioration which could cause improper venting or leakage of combustion products.
• Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
If after inspection of the vent system you found sooting or deterioration, something is wrong. Call a Maytag Service
Specialist at 1-800-365-0024 for an authorized servicer or your local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.
FIGURE 24.
Burner Cleaning
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.
21
Page 22
The burner needs to be removed for cleaning. Call a Maytag
Service Specialist at 1-800-365-0024 for an authorized servicer to remove and clean the burner and correct the problem that required the burner to be cleaned.
qualified technician. At a minimum, the anode(s) should be checked annually after the warranty period.
T emperature-Pressure Relief Valve Operation
Housekeeping
V acuum around base of water heater for dust, dirt, and lint on a regular basis.
AT LEAST ONCE EVERAT LEAST ONCE EVER
AT LEAST ONCE EVER
AT LEAST ONCE EVERAT LEAST ONCE EVER VISUAL INSPECTION SHOULD BE MADE OFVISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OFVISUAL INSPECTION SHOULD BE MADE OF THE THE
AIR INTAIR INT
THE
AIR INT
THE THE
AIR INTAIR INT
AA
CCUMULACCUMULA
A
CCUMULA
AA
CCUMULACCUMULA
AKE SCREENAKE SCREEN
AKE SCREEN
AKE SCREENAKE SCREEN
TIONS TIONS
TIONS
TIONS TIONS
ARE NOARE NO
ARE NO
ARE NOARE NO
Y SIX MONTHS Y SIX MONTHS
Y SIX MONTHS
Y SIX MONTHS Y SIX MONTHS
..
CLEAN IF LINT CLEAN IF LINT
.
CLEAN IF LINT
..
CLEAN IF LINT CLEAN IF LINT
TICEDTICED
TICED
TICEDTICED
..
.
..
AA
A
AA
The temperature-pressure relief valve must be manually operated at least once a year.
When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 25.
INSTALLED IN SUIT ABLE AREA: To insure sufficient ventilation and combustion air supply, proper clearances from the water heater must be maintained. See Facts to Consider About the Location section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a fire.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.
FIGURE 25.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult a Maytag
Service Specialist at 1-800-365-0024 for further information. Do not plug the temperature-pressure relief valve.
Draining
Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/ or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a
The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
22
Page 23
• Turn the gas control knob to the “OFF” position.
• Remove the washer and put the new one in place.
• CLOSE the cold water inlet valve to the water heater.
• OPEN a nearby hot water faucet and leave open to allow for draining.
• Connect a hose to the drain valve and terminate to an adequate drain.
• OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.
• CLOSE the drain valve.
• Follow instructions in the Filling The Water heater section.
• Follow the lighting instructions in the Lighting section to restart the water heater.
Drain V alve Washer Replacement
(See Figure 26)
NOTE: For ordering replacement washers, refer to the “Repair Parts List” section of this manual.
• Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.
• Follow instructions in the Filling The Water Heater section.
• Check for leaks.
• Follow the lighting instructions in the Lighting section to restart the water heater.
FIGURE 26.
Service
Before calling for repair service, read the Start Up Conditions and Operational Conditions found in the T roubleshooting Guide of this manual.
• Turn “OFF” gas supply to water heater.
• Follow “Draining” instructions.
• Turning counter clockwise ( ), remove the hex cap below the screw handle.
TROUBLESHOOTING
Start Up Conditions
Draft Hood Operation
Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating, such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame is not drawn toward the draft hood, shut off the water heater and make necessary air supply changes to correct.
Condensation
Whenever the water heater is filled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when:
• A new water heater is filled with cold water for the first time.
• Burning gas produces water vapor In water heaters,
If a condition persists or you are uncertain about the operation of the water heater, let the Maytag Customer Service check it out.
Call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer.
particularly high efficiency models where flue temperatures are lower.
• Large amounts of hot water are used in a short time and the refill water in the tank is very cold.
Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.
Excessive condensation can cause pilot outage due to water running down the flue tube onto the main burner and putting out the pilot.
Because of the suddenness and amount of water, condensation water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disappear.
Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s demands for hot water including dishwashers, washing machines and shower heads.
23
Page 24
Excessive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest.
Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.
Smoke / Odor
It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.
Operational Conditions
Smelly Odor
In each water heater there is installed at least one anode rod
(see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop:
• a concentration of sulfate in the supply water.
Thermal Expansion
Water supply system may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc., to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of water heater’s temperature-pressure relief valve is reached, the valve will relief the excess pressure. The
temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable
condition and must be corrected.
• little or no dissolved oxygen in the water.
• a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)
• an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Contact a Maytag Service Specialist at
1-800-365-0024 for further information concerning an Anode Replacement Kit and this Chlorination Treatment.
If the smelly water persists after the anode replacement and chlorination treatment, we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem.
Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.
“AIR” In Hot Water Faucets
It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion in the water system. Thermal expansion tanks are available for ordering through a Maytag Service Specialist at 1-800-365-0024. Contact the local plumbing inspector, water supplier and/or call a Maytag Service Specialist at
1-800-365-0024 for assistance in controlling these situations.
Strange Sounds
Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See Condensation section.
HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.
24
Page 25
High Temperature Shut-Off System
This water heater is equipped with an automatic gas Shut-off system. This system works when high water temperatures are present. Turn “OFF” the entire gas supply to the water heater. The high temperature Shut-off is built into the gas control valve. It is non-resettable. If the high temperature shut-off activates, the gas control valve must be replaced. Call a Maytag
Service Specialist at 1-800-365-0024 for an authorized servicer.
Leakage Checkpoints
H. Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.
I. Water in the water heater bottom or on the floor may be from
condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage should also be checked.
* To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the Periodic Maintenance section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow Filling the Water Heater instructions in the Installing the New Water Heater section.
Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater, see Figure 28.
A. Water at the draft hood is water vapor which has condensed
out of the combustion products. This is caused by a problem in the vent. Call a Maytag Service Specialist at
1-800-365-0024 for an authorized servicer.
B. *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking. C. *The anode rod fitting may be leaking. D. Small amounts of water from temperature-pressure relief
valve may be due to thermal expansion or high water
pressure in your area. E. *The temperature-pressure relief valve may be leaking at
the tank fitting. F. Water from a drain valve may be due to the valve being
slightly opened. G. *The drain valve may be leaking at the tank fitting.
FIGURE 28.
25
Page 26
TROUBLESHOOTING GUIDE
These guidelines should be used by a qualified Maytag Service Specialist. Call a Maytag Service Specialist at 1-800-365-0024
for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product.
Problem Cause Solution
Improperly sealed, hot or cold supply connection, Tighten threaded connections.
WA TER LEAKS
LEAKING T&P VALVE
SMELL Y ODORS
PILOT WILL NOT LIGHT of igniter wire.
relief valve, drain valve, or thermostat threads. Leakage from other appliances or water lines. Inspect other appliances near water heater. Condensation of flue products. Refer to CONDENSATION. Thermal expansion in closed water system. Install thermal expansion tank (DO NOT plug T&P valve). Improperly seated valve. Check relief valve for proper operation
(DO NOT plug T&P valve).
High sulfate or mineral content in water supply. Drain and flush heater thoroughly, then refill.
Bacteria in water supply. Chlorinate or aerate water supply. Gas control knob not positioned correctly. Refer to LIGHTING INSTRUCTIONS. Main gas supply off. Turn on main gas shutoff valve. Igniter tip more than 1/8" from pilot hood. Adjust igniter tip. Thermocouple malfunction. Replace pilot assembly. Thermocouple TCO malfunction. Replace pilot assembly . Melted insulation on igniter wire or shorting Contact a Maytag Service Specialist to determine cause.
High ambient room temperature. Contact a Maytag Service Specialist to determine cause.
Wire disconnected from spark igniter. Reconnect wire connector to spark igniter. Broken electrode or electrical wire. Replace pilot assembly. Piezo Igniter generator fails to operate or Replace Piezo Igniter generator. malfunctions. Thermocouple TCO malfunction. Replace pilot assembly . High ambient room temperature. Contact a Maytag Service Specialist to
determine cause.
BURNER WILL NOT Dirty or clogged air intake screen. Clean and reinstall air intake screen.
STAY LIT Flame arrestor openings blocked. Contact a Maytag Service Specialist to
determine cause. Defective Gas Control. Replace Gas Control. Dirty pilot burner. Clean pilot assembly. Dirty or clogged air intake screen. Clean and reinstall air intake screen.
PILOT OUTAGE
NOT ENOUGH Low gas pressure. Contact your gas supplier.
HOT WA TER Incoming water is unusually cold. Allow more time for heater to re-heat.
WA TER T OO HOT Thermostat set too high. Refer to TEMPERA TURE REGULATION.
WA TER HEA TER SOUNDS Condensation dripping on burner. Refer to CONDENSATION.
SIZZLING - RUMBLING
SOOTING
VENT GAS ODORS
Thermocouple tip is not in contact with pilot flame. Insert thermocouple correctly. Thermocouple malfunction. Replace pilot assembly. Thermocouple TCO malfunction. Replace pilot assembly . Defective Gas Control. Replace Gas Control. Heater not lit or thermostat not on. Refer to LIGHTING INSTRUCTIONS. Thermostat set too low. Refer to TEMPERA TURE REGULATION. Heater undersized. Reduce hot water use.
Leaking hot water pipes or fixtures. Have plumber check and repair leaks. High temperature limit switch activated. Contact a Maytag Service Specialist to
determine cause.
Sediment or calcium in bottom of heater tank. Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual. Improper combustion. No adjustment available. Contact a Maytag Service
Specialist to determine cause. Lack of supply air. Improperly installed vent piping. Contact a Maytag Service Specialist to determine cause. Downdraft. Poor combustion.
26
Page 27
REP AIR P ARTS LIST
MAYTAG GAS W ATER HEA TERS
MODEL NO’S
HRX40YARS 40 Gallon Natural Gas
HRX40HARS 40 Gallon Propane Gas (L.P.)
HRX40YART 40 Gallon Natural Gas HRX40HART 40 Gallon Propane Gas (L.P.) HRX40YQRT 40 Gallon Natural Gas HRX40HQRT 40 Gallon Propane Gas (L.P.)
BURNER ASSEMBL Y
PILOT ASSEMBL Y
Key Model Numbers
No. Part Description HRX40YARS HRX40HARS HRX40Y ART HRX40HART HRX40YQRT HRX40HQRT
1 Air Intake Screen 9003406 9003406 9003406 9003406 9003406 9003406 2 Anode Rod 9001834 9001834 9001834 9001834 9003487 9003487 3 Burner Assembly - Std. 9003379 9003554 9003563 9003564 9003549 9003550 3 Burner Assembly - High Altitude 9003489 9003584 9003596 9003597 9003578 9003579 4 Burner Head** 9003385 9003631 9003385 9003422 9003421 9003633 5 Burner Orifice - Std.** 9003493 9003453 9003453 9003453 9003494 9003643 5 Burner Orifice - High Altitude** 9003492 9003453 9003453 9003453 9003494 9003647 6 Burner Tube** 9003389 9003476 9003391 9003392 9003635 9003644 7 Dip Tube/Inlet Tube 9003500 9003500 9003501 9003501 9003637 9003637 8 Dip Tube/Inlet Tube Gasket 9001595 9001595 9001595 9001595 9001595 9001595 9 Draft Hood 9003405 9003405 9003405 9003405 9003499 9003499
10 Drain Valve 9002402 9002402 9002402 9002402 9002401 9002401
1 1 Drain Valve Washer 9001584 9001584 9001584 9001584 9001584 9001584 12 Flue Baffle 9003480 9003480 9003649 9003649 9003636 9003636 13 Flue Restrictor 9000275 9000275 9000275 9000275 9003524 9003524 14 Gas Control Valve 9003407 9003408 9003407 9003408 9003638 9003639 15 Inner Door** 9003398 9003398 9003400 9003400 9003400 9003400 16 Inner Door Gasket 9003401 9003401 9003401 9003401 9003401 9003401
*17 Instruction Manual 184388-002 184388-002 184388-002 184388-002 184388-002 184388-002
18 Nipple w/Heat Traps 9003719 9003719 9003719 9003719 NA NA 19 Outer Door 9003409 9003409 9003409 9003409 9003409 9003409 20 Outer Door Filler NA NA NA NA NA NA 21 Piezo Igniter w/Bracket 9003410 9003410 9003410 9003410 9003410 9003410 22 Pilot Assembly - Std.** 9003530 9003455 9003530 9003472 9003530 9003543 22 Pilot Assembly - High Altitude** 9003542 9003455 9003542 9003472 9003542 9003543 23 Pipe Insulation 9003971 9003971 9003971 9003971 9003971 9003971 24 Secondary Anode Rod 9004274 9004274 9004274 9004274 NA NA 25 T & P Insulation 9003716 9003716 9003716 9003716 9003716 9003716 26 Temperature-Pressure Relief V alve 9000071 9000071 9000071 9000071 9004030 9004030 27 Thermostat Shield (Optional) 9003696 9003696 9003696 9003696 9003696 9003696 28 Viewport Assembly 9003414 9003414 9003414 9003414 9003414 9003414
* Not Shown. ** Includes Inner Door Gasket
Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer. Be sure to provide all pertinent facts when you call or visit.
THIS IS A REP AIR P ARTS LIST, NOT A PACKING LIST.
The model number of this gas water heater will be found on the model rating plate located near the gas control valve.
When ordering repair parts, always give the following information:
• Model number • Part Description
• Serial Number • Part Number
27
Page 28
REP AIR P ARTS LIST
MAYTAG GAS W ATER HEA TERS
MODEL NO’S
HRX50YART 50 Gallon Natural Gas
HRX50HART 50 Gallon Propane Gas (L.P.)
HRX50YQRT5 50 Gallon Natural Gas
HRX50HQRT5 50 Gallon Propane Gas (L.P.)
HRX50YQRT 50 Gallon Natural Gas
HRX50HQRT 50 Gallon Propane Gas (L.P.)
BURNER ASSEMBL Y
PILOT ASSEMBL Y
Key Model Numbers No. Part Description HRX50Y ART HRX50HART HRX50YQRT5 HRX50HQRT5 HRX50YQRT HRX50HQRT
1 Air Intake Screen 9003406 9003406 9003406 9003406 9003406 9003406 2 Anode Rod 9003487 9003487 9001829 9001829 9003465 9003465 3 Burner Assembly - Std. 9003382 9003546 9003573 9003574 9003383 9003551 3 Burner Assembly - High Altitude 9003491 9003575 9003610 900361 1 9003580 9003581 4 Burner Head** 9003385 9003422 9003421 9003633 9003421 9003633 5 Burner Orifice - Std.** 9003493 9003495 9002978 9004273 9003494 9003634 5 Burner Orifice - High Altitude** 9003492 9003453 9004256 9003643 9003494 9003648 6 Burner Tube** 9004271 9004272 9003520 9003659 9003389 9003476 7 Dip Tube/Inlet Tube 9003473 9003473 9003501 9003501 9003501 9003501 8 Dip Tube/Inlet Tube Gasket 9001595 9001595 9001595 9001595 9001595 9001595 9 Draft Hood 9003405 9003405 9004010 9004010 9003499 9003499
10 Drain Valve 9002402 9002402 9002402 9002402 9002401 9002401
1 1 Drain Valve Washer 9001584 9001584 9001584 9001584 9001584 9001584 12 Flue Baffle 9003403 9003403 9003985 9003985 9003497 9003497 13 Flue Restrictor 9003445 9003445 9003498 9003498 9003498 9003498 14 Gas Control Valve 9003407 9003408 9003638 9003639 9003407 9003408 15 Inner Door** 9003398 9003398 9003398 9003398 9003398 9003398 16 Inner Door Gasket 9003401 9003401 9003401 9003401 9003401 9003401
*17 Instruction Manual 184388-002 184388-002 184388-002 184388-002 184388-002 184388-002
18 Nipple w/Heat Traps 9003719 9003719 9003719 9003719 NA NA 19 Outer Door 9003409 9003409 9003409 9003409 9003409 9003409 20 Outer Door Filler NA NA NA NA NA NA 21 Piezo Igniter w/Bracket 9003410 9003410 9003410 9003410 9003410 9003410 22 Pilot Assembly - Std.** 9003530 9003541 9003496 9003455 9003496 9003544 22 Pilot Assembly - High Altitude** 9003542 9003541 9003521 9003455 9003521 9003544 23 Pipe Insulation 9003971 9003971 9003971 9003971 9003971 9003971 24 Secondary Anode Rod 9004274 9004274 9004274 9004274 9004274 9004274 25 T & P Insulation NA NA NA NA NA NA 26 Temperature-Pressure Relief V alve 9003484 9003484 9000071 9000071 9000728 9000728 27 Thermostat Shield (Optional) 9003696 9003696 9003696 9003696 9003696 9003696 28 Viewport Assembly 9003414 9003414 9003414 9003414 9003414 9003414
* Not Shown. ** Includes Inner Door Gasket
Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer. Be sure to provide all pertinent facts when you call or visit.
THIS IS A REP AIR P ARTS LIST, NOT A PACKING LIST.
The model number of this gas water heater will be found on the model rating plate located near the gas control valve.
When ordering repair parts, always give the following information:
• Model number • Part Description
• Serial Number • Part Number
28
Page 29
REP AIR P ARTS LIST
STATE/MAYTAG PART NUMBER CONVERSION KEY
STATE MAYTAG
STATE MAYT AG ETC2X 66001013
ETC5X 66001014 9000071 66001079 9000275 66001187 9000728 66001216 9000734 66001020 9001584 66001021 9001595 66001812 9001829 66001251 9001834 66001252 9002401 66001015 9002402 66001016 9002978 66001901 9003379 66001491 9003382 66001492 9003383 66001493 9003385 66001494 9003389 66001495 9003391 66001496 9003392 66001497 9003398 66001498 9003400 66001499 9003401 66001500 9003403 66001501 9003405 66001502 9003406 66001503 9003407 66001504 9003408 66001505 9003409 66001506 9003410 66001507 9003414 66001509 9003421 66001510 9003422 66001511 9003445 66001513 9003453 66001515 9003455 66001516 9003465 66001763 9003472 66001519 9003473 66001520 9003476 66001521 9003480 66001522 9003484 66001760 9003487 66001725 9003489 66001535 9003491 66001536 9003492 66001537
STATE MAYT AG
9003493 66001538 9003493 66001538 9003494 66001778 9003495 66001540 9003496 66001541 9003497 66001542 9003498 66001652 9003499 66001780 9003500 66001596 9003501 66001544 9003520 66001607 9003521 66001545 9003524 66001795 9003530 66001547 9003541 66001549 9003542 66001550 9003542 66001550 9003543 66001551 9003544 66001552 9003546 66001553 9003549 66001792 9003550 66001799 9003551 66001556 9003554 66001557 9003563 66001558 9003564 66001557 9003573 66001782 9003574 66001786 9003575 66001560 9003578 66001791 9003579 66001798 9003580 66001563 9003581 66001564 9003584 66001565 9003596 66001566 9003597 66001567 9003610 66001825 9003611 66001826 9003631 66001568 9003633 66001570 9003634 66001571 9003635 66001572 9003636 66001794 9003636 66001794 9003637 66001793 9003637 66001793
STATE MAYT AG
9003638 66001575 9003638 66001575 9003639 66001576 9003643 66001801 9003644 66001581 9003647 66001800 9003648 66001584 9003649 66001589 9003649 66001589 9003651 66001592 9003659 66001620 9003696 66001667 9003716 66001709 9003719 66001705 9003891 66001832 9003932 66001746 9003971 66001755 9003971 66001708 9003985 66001807 9004005 66001777 9004008 66001783 9004009 66001784 9004010 66001785 9004010 66001785 9004011 66001787 9004012 66001788 9004015 66001802 9004017 66001803 9004018 66001804 9004019 66001805 9004022 66001824 9004030 66001797 9004107 66001833 9004256 66001862 9004271 66001905 9004272 66001906 9004273 66001903 9004274 66001881
184388-002 66001907
29
Page 30
NOTES
30
Page 31
NOTES
31
Page 32
WARRANTY
FULL ONE YEAR W ARRANTY
For one year from the date of original retail purchase, any part which fails in normal home use will be repaired or replaced free of charge.
If a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge.
The warranty of the replacement is the balance of the original water heater’s warranty.
LIMITED P ARTS WARRANTY
After the first year and through the tenth year from the date of original retail purchase, any parts which fail due to a defect in materials or workmanship, will be replaced or repaired free of charge for the part itself, with the owner paying all other costs, including labor, mileage and transportation.
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty coverage for parts that are proved to be defective in material or workmanship is effective for one year from the date of the original retail purchase.
The warranty of the replacement is the balance of the original water heater’s warranty, or twelve months from the date of the part(s) purchase, whichever comes first.
This warranty is limited to the original owner of the water heater.
LIMITED T ANK WARRANTY AGAINST LEAKS
After the first year and through the tenth year from the date of original retail purchase, if a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge for the water heater, with the owner paying all other costs, including labor, mileage and transportation.
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty coverage for the tanks that are proved to be defective in material or workmanship is effective for two years from the date of the original retail purchase.
The warranty of the replacement is the balance of the original water heater’s warranty. Please note: The full and limited warranty applies only while this water heater is used in the United States of
America. This warranty is limited to the original owner of the water heater.
TO RECEIVE W ARRANTY SERVICE
To locate an authorized service company in your area contact the Maytag dealer from whom your appliance was purchased; or call a Maytag Service Specialist at the number listed below. Should you not receive satisfactory warranty service, please call or write:
Maytag Service Specialist 500 Lindahl Parkway Ashland City, TN 37015-1299 U.S.A. 1-800-365-0024
When contacting a Maytag Service Specialist be sure to provide the model and serial number of your appliance, the name and address of the dealer from whom you purchased the appliance and the date of purchase.
MAYTAG WATER HEATERS ARE MANUFACTURED AND THIS WARRANTY IS PROVIDED BY STATE INDUSTRIES, INC., ASHLAND CITY , TN. MA YTAG IS A TRADEMARK OF THE MA YTAG CORPORATION AND IS USED UNDER LICENSE TO STATE INDUSTRIES, INC.
32
Loading...