C3 Technology® Gas Water Heaters meet
the new ANSI Z21.10.1 st andard that deals
with the accidental or unintended ignition
of flammable vapors, such as those
emitted by gasoline.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and
others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very
important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you
to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death.
DANGER indicates an imminently
DANGER
W ARNING
CAUTION
hazardous situation which, if not avoided,
could result in death or injury.
WARNING indicates a potentially hazardous
situation which, if not avoided, could result
in death or injury.
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury.
CAUTION used without the safety alert
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and
how to avoid the risk of injury.
symbol indicates a potentially hazardous
situation which, if not avoided, could result
in property damage.
IMPORTANT DEFINITIONS
• Maytag Customer Service Center: The Maytag Customer Service Center has the ability equivalent to a licensed tradesman in
the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the
National Fuel Gas Code as it relates to the installation of gas fired water heaters. The Service Center also has a thorough
understanding of this instruction manual, and is able to perform repairs strictly in accordance with the service guidelines
provided by the manufacturer.
• Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of
gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also
offer service and inspection of appliances within the building.
2
SAFETY PRECAUTIONS
3
TABLE OF CONTENTS
SAFE INST ALLA TION, USE AND SERVICE ................................................................................................. 2
INSTRUCTIONS FOR INST ALLA TION.......................................................................................................... 7
Removing the Old Water Heater .............................................................................................................................. 7
TYPICAL INST ALLA TION............................................................................................................................... 8
Get to Know Your Water Heater .............................................................................................................................. 8
LOCA TING THE NEW HEATER.................................................................................................................. 10
Facts to Consider About the Location ...............................................................................................................10-11
in Unconfined Spaces............................................................................................................................................ 12
Combustion Air and Ventilation Appliances
in Confined Spaces .......................................................................................................................................... 12-13
Water Piping .................................................................................................................................................... 13-14
T & P Valve and Pipe Insulation.......................................................................................................................... 14
T emperature Pressure Relief V alve.................................................................................................................... 14-15
Filling the Water Heater.................................................................................................................................... 15-16
Gas Piping ....................................................................................................................................................... 17-18
T emperature Regulation ......................................................................................................................................... 20
SERVICE AND MAINTENANCE .............................................................................................................. 21-23
T ank (Sediment) Cleaning...................................................................................................................................... 21
Venting System Inspection.................................................................................................................................... 21
Anode Rod Inspection ........................................................................................................................................... 22
T emperature-Pressure Relief V alve Operation ........................................................................................................ 22
Drain V alve Washer Replacement.......................................................................................................................... 23
Service .................................................................................................................................................................. 23
Start Up Conditions ............................................................................................................................................... 23
“AIR” In Hot Water Faucets .......................................................................................................................... 24
High Temperature Shut Off System............................................................................................................... 25
REP AIR PARTS LIST .............................................................................................................................. 30-31
Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble
free service. It is strongly suggested that this new water heater
be professionally installed, contact Maytag Customer Service
(1-800-788-8899) for recommended installers.
Abbreviations Found In This Instruction Manual:
•CSA - Canadian Standards Association
•ANSI - American National Standards Institute
•NFPA - National Fire Protection Association
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturers Association
This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current
edition).
• Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THE ENTIRE MANUAL BEFORE A TTEMPTING
TO INSTALL OR OPERA TE THE WA TER HEA TER.
• The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:
In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
Canadian Standards Association, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do not
understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
• Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires, see
figure 1 and 2.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
• For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
• Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. In the
Commonwealth of Massachusetts, this product must be
installed by a licensed plumber or gasfitter.
• Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
PRODUCT SPECIFICATIONS
TANKRECOVERYMINIMUMDIMENSIONS
CAPACITYTYPERATE GALS.VENT PIPEDIAMETER IN INCHES (mm)
IN GALSOFBT UPER HOURINCHESINCHES HEIGHT TOP OF
MODEL NUMBER (LTRS)GASRATE@ 90°F RISE(mm)(mm)DRAFT HOOD
T o simplify the inst allation Maytag has available the installation p art s shown below. You may or may not need all of these accessories
depending on your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS
AVAILABLE IN 2 GALLONS (7.6 LITERS), Part No. 66001013 AND 5
GALLONS (18.9 LITERS), Part No. 66001014 CAPACITY.
Tools
You may or may not need all these tools, depending on your
type of installation. These tools can be purchased at your local
hardware store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Teflon Tape
DRILL
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
TIN SNIPS
DRAIN PANS AVAILABLE IN 22” (559 mm) DIAMETER (PART NO.
66001011) FOR WATER HEATERS HAVING A DIAMETER 20” (508
mm) OR LESS, 24” (610mm) DIAMETER (PART NO. 66001105) FOR
WA TER HEA TERS HA VING A DIAMETER 22” (559 mm) OR LESS AND
28” (711 mm) DIAMETER (P ART NO. 66001012) FOR W ATER HEA TERS
HAVING A DIAMETER 26” (660 mm) OR LESS.
Additional Tools Needed
When Sweat Soldering
• Tubing Cutters or Hacksaw
• Propane Tank
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
PROPAN E
TUBING CUTTER
TORCH
ROLL OF TEFLON
TAPE (USE ONL Y ON
WA TER HEA TER
CONNECTIONS)
GARDEN HOSE
6 FOOT TA PE
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WA TER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
6
HACKSAW
ROLL OF
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
SOLDER
FLUX
INSTRUCTIONS FOR INSTALLATION
Removing the Old Water Heater
FIGURE 1.
1. Turn “OFF” the gas supply to the
water heater.
If the main gas line Shut-off valve
serving all gas appliances is
used, also shut “OFF” the gas at
each appliance. Leave all gas
appliances shut “OFF” until the
water heater installation is
completed, see Figures 1 and 2.
2. Turn “OFF” the water supply to the
water heater at the water shut off
valve or water meter. Some
installations require that the water
be turned off to the entire house,
see Figures 1 and 3.
3. Check again to make sure the gas supply is “OFF” to the
water heater. Then disconnect the gas supply connection
from the gas control valve.
FIGURE 2.
FIGURE 3.
4. Attach a hose to the water heater
drain valve and put the other end
in a floor drain or outdoors. Open
the water heater drain valve
(behind outer door). Open a nearby
hot water faucet which will relieve
pressure in the water heater and
speed draining. The water passing
out of the drain valve may be
extremely hot. To avoid being
scalded, make sure all
connections are tight and that the
water flow is directed away from
any person, see Figures 1 and 4.
5. Disconnect the vent pipe from the draft hood where they
connect to the water heater. In most installations the vent
pipe can be lifted off after any screw or other attached devices
are removed. Dispose of the draft hood. The new water
heater has the draft hood which must be used for proper
operation.
6. If you have copper piping to the water heater, the two copper
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater.
This will avoid cutting off pipes too short. Additional cuts can
be made later if necessary. Disconnect the temperaturepressure relief valve drain line. When the water heater is
drained, disconnect the hose from the drain valve. Close the
drain valve. The water heater is now completely disconnected
and ready to be removed, see Figure 5.
FIGURE 5.
If you have galvanized pipe to the water heater, loosen the
two galvanized pipes with a pipe wrench at the union in each
line. Also disconnect the piping remaining to the water heater .
These pieces should be saved since they may be needed
when reconnecting the new water heater. Disconnect the
temperate-pressure relief valve drain line. When the water
heater is drained, disconnect the hose from the drain valve.
Close the drain valve. The water heater is now completely
disconnected and ready to be removed. Mineral buildup or
sediment may have accumulated in the old water heater.
This causes the water heater to be much heavier than normal
and this residue, if spilled out, could cause staining, see
Figure 6.
FIGURE 4.
7
FIGURE 6.
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Draft Hood
C Anode
D Hot Water Outlet
E Outlet
F Standard Pipe Fittings
G Gas Supply
H Manual Gas Shut-off Valve
I Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
J Drip Leg (Sediment Trap)
K Inner Door
L Outer door
M Union
N Inlet Water Shut-off Valve
O Cold Water Inlet
P Inlet Dip Tube
Q Temperature-Pressure Relief Valve
R Rating Plate
S Flue Baffle
T Thermostat
U Drain Valve
V Pilot and Main Burner
W Flue
X Drain Pan
Y Piezo Igniter
Z Air Intake Screen
(T) THERMOSTA T
* ALL PIPING MA TERIALS TO BE
SUPPLIED BY CUSTOMERS.
** CLOSED WA TER SYSTEMS ARE THOSE WITH BACK FLOW
PREVENTION DEVICES INSTALLED IN THE INLET
SERVICE LINE.
(V) PILOT & MAIN BURNER
FIGURE 7.
8
TYPICAL INSTALLATION
MIXING V ALVE USAGE
FIGURE 8.
This appliance has been design certified as complying with
American National Standard/CSA Standard for water heaters
and is considered suitable for:
Water (Potable) Heating: All models are considered suitable
for water (potable) heating.
HOTTER WA TER CAN SCALD:
Water heaters are intended to produce hot water. Water heated
to a temperature which will satisfy space heating, clothes
washing, dish washing, and other sanitizing needs can scald
and permanently injure you upon contact. Some people are
more likely to be permanently injured by hot water than others.
These include the elderly, children, the infirm, or physically/
mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or state
law requiring a certain temperature water at the hot water tap,
then you must take special precautions. In addition to using the
lowest possible temperature setting that satisfies your hot water
needs, a means such as a *Mixing Valve, shall be used at the
hot water taps used by these people or at the water heater.
Mixing valves are available at plumbing supply or hardware
stores. See Figure 8. Valves for reducing point of use temperature
by mixing cold and hot water are also available. Consult MaytagCustomer Service (1-800-788-8899). Follow mixing valve
manufacturer’s instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
“Temperature Regulation” section in this manual, see Figures
22 and 23 on page 20.
9
LOCATING THE NEW WATER HEATER
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater,
because the placement is a very important consideration for
the safety of the occupants in the building and for the most
economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed:
• Select a location indoors as close as practical to the gas
vent or chimney to which the water heater vent is going to be
connected, and as centralized with the water piping system
as possible.
• Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
Installation of the water heater must be accomplished in such a
manner that if the tank or any connections should leak, the flow
will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are
available at your local hardware store. Such a drain pan must
have a minimum length and width of at least 2 inches (51 mm)
greater that the water heater dimensions and must be piped to
an adequate drain. The pan must not restrict combustion air
flow.
• Devices that will turn off the gas supply to a gas water heater
while at the same time shutting off its water supply.
INST ALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP or
butane, etc.] and other substances such as adhesives, etc.)
emit flammable vapors which can be ignited by a gas water
heater’s pilot light or main burner. The resulting flashback and
fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition
resistant water heater and is designed to reduce the chances
of flammable vapors being ignited, gasoline and other
flammable substances should never be stored or used in the
same vicinity or area containing a gas water heater or other
open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage
may result in property damage, even with the use of a drain pan
piped to a drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used in
conjunction with a piped drain pan. These devices are available
from some plumbing supply wholesalers and retailers, and
detect and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm or
turn off the incoming water to the water heater when leakage
is detected.
• Sensors mounted in the drain pan that turn off the water
supply to the entire home when water is detected in the drain
pan.
• Water supply shut-off devices that activate based on the
water pressure differential between the cold water and hot
water pipes connected to the water heater.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2 mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor
must be covered by the panel. Failure to heed this warning may
result in a fire hazard.