Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and
others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very
important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you
to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death.
DANGER indicates an imminently
DANGER
W ARNING
CAUTION
hazardous situation which, if not avoided,
could result in death or injury.
WARNING indicates a potentially hazardous
situation which, if not avoided, could result
in death or injury.
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury.
CAUTION used without the safety alert
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and
how to avoid the risk of injury.
symbol indicates a potentially hazardous
situation which, if not avoided, could result
in property damage.
IMPORTANT DEFINITIONS
• Maytag Customer Service Center: The Maytag Customer Service Center has the ability equivalent to a licensed tradesman in
the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the
National Fuel Gas Code as it relates to the installation of gas fired water heaters. The Service Center also has a thorough
understanding of this instruction manual, and is able to perform repairs strictly in accordance with the service guidelines
provided by the manufacturer.
• Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of
gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also
offer service and inspection of appliances within the building.
2
SAFETY PRECAUTIONS
3
TABLE OF CONTENTS
SAFE INSTALLA TION, USE AND SERVICE....................................................................................................................................... 2
TABLE OF CONTENTS......................................................................................................................................................................4
Additional Tools Needed When Sweat Soldering ...................................................................................................................... 6
INSTRUCTIONS FOR INST ALLA TION .............................................................................................................................................. 7
Removing the Old Water Heater.................................................................................................................................................7
TYPICAL INST ALLA TION ................................................................................................................................................................ 8,9
Get to Know Your Water Heater .................................................................................................................................................. 8
LOCA TING THE NEW HEATER ....................................................................................................................................................... 10
Facts to Consider About the Location.................................................................................................................................. 10,11
Combustion Air and Ventilation ........................................................................................................................................... 11-13
in Unconfined Spaces ............................................................................................................................................................... 13
Combustion Air and Ventilation Appliances
in Confined Spaces .............................................................................................................................................................13,14
Water Piping .........................................................................................................................................................................14,15
T & P Valve and Pipe Insulation ........................................................................................................................................15,16
Temperature Pressure Relief Valve .....................................................................................................................................16,17
Filling the Water Heater ............................................................................................................................................................ 17
Gas Piping ................................................................................................................................................................................ 26
Temperature Regulation ......................................................................................................................................................29-31
SERVICE AND MAINTENANCE ..................................................................................................................................................32-34
Tank (Sediment) Cleaning ........................................................................................................................................................ 32
Venting System Inspection .......................................................................................................................................................32
L.P. Gas Control Valve & Burner Assembly Replacement Information .................................................................................... 33
Anode Rod Inspection .............................................................................................................................................................. 33
Start Up Conditions ................................................................................................................................................................... 35
Smelly Water ..............................................................................................................................................................35,36
“AIR” In Hot Water Faucets ............................................................................................................................................. 36
High Temperature Shut Off System ................................................................................................................................36
Not Enough or No Hot Water .......................................................................................................................................... 36
Water is To Hot ................................................................................................................................................................ 36
Thermostat and Gas Supply Check ......................................................................................................................................... 38
System Check ........................................................................................................................................................................... 39
REP AIR PAR TS LIST ..................................................................................................................................................................41-44
Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble
free service. It is strongly suggested that this new water heater
be professionally installed, contact Maytag Customer Service
(1-800-788-8899) for recommended installers.
Abbreviations Found In This Instruction Manual:
•CSA - Canadian Standards Association
•ANSI - American National Standards Institute
•NFPA - National Fire Protection Association
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturers Association
This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas W ater Heaters ANSI Z21.10.1 • CSA 4.1 (current
edition). The installation must conform with this manual, local
codes and with the current edition of the National Fuel Gas
Code, ANSIZ223.1 NFPA 54.
• Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THE ENTIRE MANUAL BEFORE A TTEMPTING
TO INSTALL OR OPERA TE THE WA TER HEA TER.
local codes, installations shall comply with the following:
In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
Canadian Standards Association, 8501 East Pleasant Valley
Rd., Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do not
understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
• Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires, see
figure 1 and 2.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
• For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
• Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. In the
Commonwealth of Massachusetts, this product must be
installed by a licensed plumber or gasfitter.
• The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
• Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
PRODUCT SPECIFICATIONS
TANKRECOVERYDIMENSIONS
CAP ACITYTYPERATE GALS.VENT PIPEDIAMETER IN INCHES (mm)
IN GALSO FBT UPER HOURINCHESINCHES HEIGHT TOP OF
MODEL NUMBER (LITERS)GA SRATE@ 90°F RISE(mm)(mm)DRAFT HOOD
* High altitude models have a B.T .U./Recovery Rate 10% less than shown.
** Limited usage of 2” vent pipe - see pages 19 through 26.
*** Limited usage of 4” vent pipe - see pages 19 through 26.
5
ACCESSORIES AND TOOLS NEEDED
Accessories
T o simplify the inst allation Maytag has available the installation p art s shown below. You may or may not need all of these accessories
depending on your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS
AVAILABLE IN 2 GALLONS (7.6 LITERS), Part No. 66001013 AND 5
GALLONS (18.9 LITERS), Part No. 66001014 CAPACITY.
Tools
You may or may not need all these tools, depending on your
type of installation. These tools can be purchased at your local
hardware store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Teflon Tape
DRILL
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
TIN SNIPS
DRAIN PANS AVAILABLE IN 22” (559 mm) DIAMETER (PART NO.
66001011) FOR WATER HEATERS HAVING A DIAMETER 20” (508
mm) OR LESS, 24” (610mm) DIAMETER (PART NO. 66001105) FOR
WA TER HEA TERS HA VING A DIAMETER 22” (559 mm) OR LESS AND
28” (711 mm) DIAMETER (P ART NO. 66001012) FOR W ATER HEA TERS
HAVING A DIAMETER 26” (660 mm) OR LESS.
Additional Tools Needed
When Sweat Soldering
• Tubing Cutters or Hacksaw
• Propane Torch
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
PROPAN E
TUBING CUTTER
TORCH
ROLL OF TEFLON
TAPE (USE ONL Y ON
WA TER HEA TER
CONNECTIONS)
GARDEN HOSE
6 FOOT TA PE
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WA TER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
6
HACKSAW
ROLL OF
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
SOLDER
FLUX
INSTRUCTIONS FOR INSTALLATION
Removing the Old Water Heater
FIGURE 1.
4. Attach a hose to the water heater
drain valve and put the other end
in a floor drain or outdoors. Open
the water heater drain valve. Open
a nearby hot water faucet which will
relieve pressure in the water
heater and speed draining. The
water passing out of the drain valve
may be extremely hot. To avoid
being scalded, make sure all
connections are tight and that the
water flow is directed away from
any person, see Figures 1 and 4.
5. Disconnect the vent pipe from the draft hood where they
connect to the water heater. In most installations the vent
pipe can be lifted off after any screw or other attached devices
are removed. Dispose of the draft hood. The new water
heater has the draft hood which must be used for proper
operation.
6. If you have copper piping to the water heater, the two copper
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater.
This will avoid cutting off pipes too short. Additional cuts can
be made later if necessary. Disconnect the temperaturepressure relief valve drain line. When the water heater is
drained, disconnect the hose from the drain valve. Close the
drain valve. The water heater is now completely disconnected
and ready to be removed, see Figure 5.
FIGURE 4.
1. Turn “OFF” the gas supply to the
water heater.
If the main gas line Shut-off valve
serving all gas appliances is
used, also shut “OFF” the gas at
each appliance. Leave all gas
appliances shut “OFF” until the
water heater installation is
completed, see Figures 1 and 2.
2. Turn “OFF” the water supply to the
water heater at the water shut off
valve or water meter. Some
installations require that the water
be turned off to the entire house,
see Figures 1 and 3.
3. Check again to make sure the gas supply is “OFF” to the
water heater. Then disconnect the gas supply connection
from the gas control valve.
FIGURE 2.
FIGURE 3.
FIGURE 5.
If you have galvanized pipe to the water heater, loosen the
two galvanized pipes with a pipe wrench at the union in each
line. Also disconnect the piping remaining to the water heater .
These pieces should be saved since they may be needed
when reconnecting the new water heater. Disconnect the
temperature-pressure relief valve drain line. When the water
heater is drained, disconnect the hose from the drain valve.
Close the drain valve. The water heater is now completely
disconnected and ready to be removed. Mineral buildup or
sediment may have accumulated in the old water heater.
This causes the water heater to be much heavier than normal
and this residue, if spilled out, could cause staining, see
Figure 6.
7
FIGURE 6.
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Blower
C Anode
D Hot Water Outlet
E Standard Pipe Fittings
F Gas Supply
G Manual Gas Shut-off V alve
H Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
I Drip Leg (Sediment Trap)
J Inner Door
K Outer door
L Union
M Inlet Water Shut-off V alve
N Cold Water Inlet
O Inlet Dip Tube
P Temperature-Pressure Relief Valve
Q Rating Plate
R Flue Baffle
S Thermostat
T Drain Valve
U Pilot and Main Burner
V Flue
W Drain Pan
(S) THERMOSTA T
* ALL PIPING MA TERIALS TO BE
SUPPLIED BY CUSTOMERS.
** CLOSED W A TER SYSTEMS ARE THOSE WITH BACK FLOW
PREVENTION DEVICES INSTALLED IN THE INLET
SERVICE LINE.
(U) PILOT & MAIN BURNER
FIGURE 7.
8
TYPICAL INSTALLATION
MIXING V ALVE USAGE
FIGURE 8.
This appliance has been design certified as complying with
American National Standard/CSA Standard for water heaters
and is considered suitable for:
Water (Potable) Heating: All models are considered suitable
for water (potable) heating.
HOTTER WA TER CAN SCALD:
more likely to be permanently injured by hot water than others.
These include the elderly, children, the infirm, or physically/
mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or state
law requiring a certain temperature water at the hot water tap,
then you must take special precautions. In addition to using the
lowest possible temperature setting that satisfies your hot water
needs, a means such as a *Mixing Valve, shall be used at the
hot water taps used by these people or at the water heater.
Mixing valves are available at plumbing supply or hardware
stores. See Figure 8. Valves for reducing point of use temperature
by mixing cold and hot water are also available. Consult MaytagCustomer Service (1-800-788-8899). Follow mixing valve
manufacturer’s instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
“Temperature Regulation” section in this manual, see Figure
52 on page 31.
This water heater shall not be connected to any heating
system(s) or component(s) previously used with a non-potable
water heating appliance.
Toxic chemicals such as used for treatment of boilers or nonpotable water heating appliances shall never be introduced
into a potable water space heating system.
Water heaters are intended to produce hot water. Water heated
to a temperature which will satisfy space heating, clothes
washing, dish washing, and other sanitizing needs can scald
and permanently injure you upon contact. Some people are
NOTE: T o protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended that di-electric
unions or couplings be installed on the water heater when
connected to copper pipe.
9
LOCATING THE NEW WATER HEATER
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater,
because the placement is a very important consideration for
the safety of the occupants in the building and for the most
economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed:
• The location selected should be indoors as close as practical
to the vent termination point, and as centralized with the water
piping system as possible. The water heater, as all water
heaters, will eventually leak. Do not install without adequate
drainage provisions where water flow will cause damage.
• 40,000 BTU/HR INPUT MODELS - If vented through an outside
wall or through the roof, the 3” vent piping cannot exceed a total
of 115 feet (50 feet if optional 2” vent piping is used), including
vertical and horizontal runs with one 90
are required, the venting distance must be reduced 5 feet for
every 90 elbow, see p age 22 for vent chart.
• 70,000 and 75,000 BTU/HR INPUT MODELS -If vented through
an outside wall or through the roof, the 3” vent piping cannot
exceed a total of 70 feet (110 feet if optional 4” vent piping is
used), including vertical and horizontal runs with one 90
If more elbows are required, the venting distance must be
reduced 5 feet fro every 90 elbow, see p age 22 for vent chart.
• Vent piping cannot slope downward and horizontal runs
require 1/8” per five foot rise. All horizontal runs require
adequate support at 3 1/2 foot intervals and vertical runs
supported at 5 foot intervals.
o
elbow. If more elbows
o
elbow.
Installation of the water heater must be accomplished in such a
manner that if the tank or any connections should leak, the flow
will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are
available at your local hardware store. Such a drain pan must
have a minimum length and width of at least 2 inches (51 mm)
greater that the water heater dimensions and must be piped to
an adequate drain. The pan must not restrict combustion air flow.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage
may result in property damage, even with the use of a drain pan
piped to a drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used in
conjunction with a piped drain pan. These devices are available
from some plumbing supply wholesalers and retailers, and
detect and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm or
turn off the incoming water to the water heater when leakage
is detected.
• Sensors mounted in the drain pan that turn off the water supply
to the entire home when water is detected in the drain pan.
• Water supply shut-off devices that activate based on the
water pressure differential between the cold water and hot
water pipes connected to the water heater.
• Devices that will turn off the gas supply to a gas water heater
while at the same time shutting off its water supply.
• The water heater requires its own (separate) venting system.
It cannot be connected to an existing vent pipe or chimney. It
must terminate to the outdoors. Whenever possible terminate
the vent on the leeward side of the building if vented through
an outside wall. NOTE: Condensation may be created, at times,
as the combustion gases exit the vent cap and discoloration
of surfaces in proximity to the vent cap may occur.
The power vent water heater requires its own (separate) venting
system. It cannot be connected to an existing vent pipe or
chimney. It must be terminated to the out doors. Failure to properly
install the venting system can result in asphyxiation, a fire or
explosion and can cause DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
• The water heater comes equipped with a 7 foot power cord
which can be used to connect to a 110/120 volt power source
if (1) local codes allow, and (2) there is a three prong recept acle
available. This unit must have a grounded outlet to operate.
Do not use an extension cord. If there is not a suitable
receptacle and/or local codes prohibit use of a power cord,
field wiring must be provided.
10
INST ALLA TIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP
or butane, etc.] and other substances such as adhesives, etc.)
emit flammable vapors which can be ignited by a gas water
heater’s pilot light or main burner. The resulting flashback and
fire can cause death or serious burns to anyone in the area, as
well as property damage. If installation in such areas is your
only option, then installation must be accomplished in a way
that the pilot flame and main burner flame are elevated from
the floor at least 18 inches. While this may reduce the chances
of flammable vapors, from a floor spill being ignited, gasoline
and other flammable substances should never be stored or
used in the same room or area containing a gas water heater
or other open flame or spark producing appliance. NOTE:
Flammable vapors may be drawn by air currents from other
areas of the structure to the appliance.
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
Propellants of aerosol sprays and volatile compounds,
(cleaners, chlorine based chemicals, refrigerants, etc.) in
addition to being highly flammable in many cases, will also
change to corrosive hydrochloric acid when exposed to the
combustion products of the water heater. The results can be
hazardous, and also cause product failure.
FIGURE 9.
• Do not obstruct water heater air
intake with insulating blanket.
• Gas and carbon monoxide
detectors are available.
• Install water heater in accordance
with the instruction manual.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2 mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor
must be covered by the panel. Failure to heed this warning
may result in a fire hazard.
A gas water heater cannot operate properly without the correct
amount of air for combustion. Do not install in a confined area
such as a closet, unless you provide air as shown in the
Locating The New Water Heater section. Never obstruct the
flow of ventilation air. If you have any doubt s or questions at all,
call your gas supplier. Failure to provide the proper amount of
combustion air can result in a fire or explosion and cause
death, serious bodily injury, or property damage.
FIGURE 10.
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas.
Minimum clearances between the water heater and
combustible construction are 0 inch at the sides and rear,
6 inches (152 mm) at the front, and 0 inches from the vent pipe.
Clearance from the top of the jacket is 14 inches (356 mm) on
most models. Note that a lesser dimension may be allowed
on some models, refer to the label attached adjacent to the
gas control valve on the water heater, see Figure 9.
Combustion Air and V entilation
When determining the installation location for a power vent
water heater, snow accumulation and drifting should be
considered in areas where applicable.
VENTING CLEARANCES
• 0” clearance for 3” (and optional 2” and 4”) PVC, ABS or
CPVC Schedule 40 vent piping from combustible surfaces.
11
• 12” minimum from the ground, 9” ceiling overhangs, see
Figure 11.
FIGURE 11.
• The Power Vent outlet terminal shall terminate at least 36”
above any forced air inlet into the building located within
10 feet, see Figure 12.
• The Power Vent outlet terminal shall terminate at least
4 feet below, 4 feet horizontally from or 1 foot above any door ,
window or gravity air inlet into the building, see Figure 12.
• 24” minimum from any appliance inlet and/or outlet vents
when directly below or 45o to either side of center line,
see Figure 13.
• 18” minimum in all directions from any obstruction that may
interfere, see Figure 14.
FIGURE 14.
• The location selection must provide clearances for servicing
and proper operation of the water heater, see Figure 15.
FIGURE 12.
• 18” minimum from other natural draft (gravity) direct vent,
power vent or power direct vent appliance inlet and/or outlet
vent(s) when directly above or 135o to either side of the
center line, see Figure 13.
FIGURE 15.
Vent termination must not be within 4 feet of any items such
as gas meters, gas valves or other gas regulating
equipment.
• The venting system must be installed in a manner which
allows inspection of the installation of the venting pipes and
joints as well as periodic inspection after installation as
required by ANSI Standards.
Vent termination must not be within 4 feet of any items such as
gas meters, gas valves or other gas regulating equipment.
Failure to have required clearances between water heater and
combustible material will result in a fire hazard.
VENTING THROUGH ROOF - CLEARANCES
• 0” clearances for 3” (or optional 2” and 4”) PVC, ABS, or
CPVC Schedule 40 piping from combustible surfaces.
• The Power Vent outlet terminal shall terminate at least 18”
above the roof surface, see Figure 16.
• The location selection must provide clearances for servicing
and proper operation of the water heater, see Figure 15.
FIGURE 13.
• The venting system must be installed in a manner which
allows inspection of the installation of the venting pipes and
joints as well as periodic inspection after the installation as
required by ANSI Standards.
12
• Do inspect the insulation blanket frequently to make certain
it does not sag, thereby obstructing combustion air flow.
Combustion Air and V entilation for
Appliances Located in Unconfined Spaces
FIGURE 16.
Insulation Blankets
• Install water heater in accordance
with the instruction manual and
NFPA 54.
• To avoid injury, combustion and
ventilation air must be taken from
outdoors.
• Do not place chemical vapor
emitting products near water
heater.
Insulation blankets available to the general public for external
use on gas water heaters are not necessary with Maytag
products. The purpose of an insulation blanket is to reduce the
standby heat loss encountered with storage tank heaters. Your
Maytag water heater meets or exceeds the National Appliance
Energy Conservation Act standards with respect to insulation
and standby loss requirements, making an insulation blanket
unnecessary.
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions (See Figure 7 for
identification of components mentioned below). Failure to follow
these instructions can restrict the air flow required for proper
combustion, potentially resulting in fire, asphyxiation, serious
personal injury or death.
UNCONFINED SP ACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m
3
per kW) of the
aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the
appliances are installed, through openings not furnished with
doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate
to provide air for combustion, ventilation and dilution of flue
gases. However, in buildings of tight construction (for example,
weather stripping, heavily insulated, caulked, vapor barrier, etc.),
additional air may need to be provided using the methods
described in Combustion Air and Ventilation for AppliancesLocated in Confined Spaces.
Combustion Air and V entilation for
Appliances Located in Confined Spaces
CONFINED SPACE is a space whose volume is less than
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the
aggregate input rating of all appliances installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figure 9 and 10 on page 11 and Figure 17 below)
The confined space shall be provided with two permanent
openings communicating directly with an additional room(s)
of sufficient volume so that the combined volume of all spaces
meets the criteria for an unconfined space. The total input of
all gas utilization equipment installed in the combined space
shall be considered in making this determination. Each
opening shall have a minimum free area of one square inch
per 1,000 Btu per hour (22 cm
gas utilization equipment in the confined space, but not less
than 100 square inches (645 cm2). One opening shall
commence within 12 inches (30 cm) of the top and one
commencing within 12 inches (30 cm) of the bottom of the
enclosures.
2
/kW) of the total input rating of all
• Do not apply insulation to the top of the water heater, as this
will interfere with safe operation of the draft hood.
• Do not cover the outer door, thermostat or temperature &
pressure relief valve.
• Do not allow insulation to come within 2” (50.8 mm) of the
floor to prevent blockage of combustion air flow to the burner.
• Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
• Do obtain new warning and instruction labels from Maytag
for placement on the blanket directly over the existing labels.
FIGURE 17.
13
B. ALL AIR FROM OUTDOORS: (See Figures 18, 19 and 20)
The confined space shall be provided with two permanent
openings, one commencing within 12 inches (30 cm) of the
top and one commencing within 12 inches (30 cm) from the
bottom of the enclosure. The openings shall communicate
directly , or by ducts, with the out doors or spaces (crawl or attic)
that freely communicate with the outdoors.
FIGURE 18.
• When directly communicating with the outdoors, each opening
shall have a minimum free area of 1 square inch per 4,000 Btu
per hour (5.5 cm
2
/kW) of total input rating of all equipment in the
enclosure, see Figure 18.
• When communicating with the outdoors through vertical
ducts, each opening shall have a minimum free area of
2
1 square inch per 4,000 BTU per hour (5.5 cm
/kW) of total
input rating of all equipment in the enclosure, see
Figure 19.
they connect. The minimum short side dimension of
rectangular air ducts shall not be less than 3 inches
(76.2 mm), see Figure 20.
FIGURE 20.
• Louvers and Grilles: In calculating free area, consideration
shall be given to the blocking effect of louvers, grilles or
screens protecting openings. Screens used shall not be
smaller than 1/4 inch (6.4 mm) mesh. If the free area through
a design of louver or grille is known, it should be used in
calculating the size opening required to provide the free
area specified. If the design and free area is not known, it
may be assumed that wood louvers will be 20-25 percent
free area and metal louvers and grilles will have 60-75
percent free area. Louvers and grilles shall be fixed in the
open position or interlocked with the equipment so that they
are opened automatically during equipment operation.
• Special Conditions Created by Mechanical Exhausting or
Fireplaces: operation of exhaust fans, ventilation systems,
clothes dryers or fireplaces may create conditions requiring
special attention to avoid unsatisfactory operation of installed
gas utilization equipment.
Water Piping
FIGURE 19.
• When communicating with the outdoors through horizontal
ducts, each opening shall have a minimum free area of 1
square inch per 2,000 BTU per hour (11 cm2/kW) of total
input rating of all equipment in the enclosure, see
Figure 20.
• When ducts are used, they shall be of the same crosssectional area as the free area of the openings to which
HOTTER WA TER CAN SCALD:
Water heaters are intended to produce hot water . Water heated
to a temperature which will satisfy space heating, clothes
washing, dish washing, cleaning and other sanitizing needs
can scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot water
than others. These include the elderly , children, the infirm, or
physically/mentally handicapped. If anyone using hot water in
your home fits into one of these groups or if there is a local
code or state law requiring a certain temperature water at the
hot water tap, then you must take special precautions. In
14
addition to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a *mixing
valve, shall be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at plumbing
supply or hardware stores, see Figure 8 on page 9 and Figure
21 below. V alves for reducing point of use temperature by mixing
cold and hot water are also available.Consult Maytag
Customer Service (1-800-788-8899). Follow manufacturer’s
instructions for installation of the valves. Before changing the
factory setting on the thermostat, read the TemperatureRegulation section in this manual.
See Figure 21 for mixing valve usage.
Figure 22 shows the typical attachment of the water piping to
the water heater. The water heater is equipped with 3/4” NPT
water connections for 40,000 Btuh models and 1 inch water
connections for 70,000 and 75,000 Btuh models.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the cold water inlet
connection. Do not solder the cold water supply line directly
to the cold water inlet. It will harm the dip tube and damage
the tank.
• Look at the top cover of the water heater. The water outlet is
marked “HOT”. Connect the hot water pipe to the hot water
outlet on the water heater.
• Look at the top of the water heater. The cold water inlet is
marked “COLD”. Connect the cold water pipe to the cold
water inlet of the water heater.
NOTE: This water heater is super insulated to minimize
heat loss from the tank. Further reduction in heat loss
can be accomplished by insulating the hot water lines
from the water heater.
FIGURE 21.
This water heater shall not be connected to any heating systems
or component(s) used with a non-potable water heating
appliance.
If a water heater installed in a closed water supply system;
such as one having a back-flow preventer, check valve, water
meter with a check valve, etc. . . in the cold water supply; means
shall be provided to control thermal expansion. Contact the
local utility or call Maytag Customer Service Center at
1-800-788-8899 for an authorized installer on how to control
this situation.
NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.
FIGURE 22.
T & P Valve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from
carton.
Fit pipe insulation over the incoming cold water line and the hot
water line. Make sure that the insulation is against the top
cover of the heater.
Fit T & P valve insulation over valve. Make sure that the insulation
does not interfere with the lever of the T & P valve.
15
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.