PARTS INDEX ..........................................................................................................................................60-90
Please read this manual in its entirety. This service
information is intended to be used by a qualified
service technician, who is familiar with proper and
safe procedures to be followed when repairing,
replacing, or adjusting any Dixie-Narco vender
components. All repairs should be performed by a
qualified service technician who is equipped with the
proper tools and replacement components, using
genuine Dixie-Narco factory parts.
REPAIRS AND/OR SERVICING
ATTEMPTED BY UNQUALIFIED
PERSONS CAN RESULT IN
HAZARDS DEVELOPING DUE TO
IMPROPER ASSEMBLY OR
ADJUSTMENTS WHILE
PERFORMING SUCH REPAIRS.
PERSONS NOT HAVING A PROPER
BACKGROUND MAY SUBJECT
THEMSELVES TO THE RISK OF
INJURY OR ELECTRICAL SHOCK
WHICH CAN BE SERIOUS OR EVEN
FATAL.
PRODUCT IDENTIFICATION
The production date of Dixie-Narco products is
determined by the date code incorporated in the
serial number.
The vender serial number takes the form xxxxyyyyzz. The first 4 digits (xxxx) identify the specific
vender. The next 4 digits (yyyy) identify the
manufacturing run that the vender was built in. The
last two alpha characters (zz) identify the quarter
and the year the vender was built. The first alphacharacter identifies the quarter.
A = 1st quarter
B = 2nd quarter
C = 3rd quarter
D = 4th quarter
Glass front is 21.1” (614.14 mm) wide, 67” (1701.8 mm) high
36.5” (927.1 mm)
682 lbs. (310 kg)
Page 4
INSTALLATION & SETUP
4
of 90
INSTALLATION & SETUP
The Dixie-Narco Coca-Cola Glass Front Vender is
designed utilizing the latest technology.
60 Hertz). The cabinet serial plate also indicates the
Amperage of the vender. The vender must be
plugged in to its own properly rated single phase,
alternating current outlet with its own circuit
protection (fuse/circuit breaker).
RECEIVING INSPECTION
DO NOT STORE THE VENDER OUTSIDE.
THIS MACHINE IS FOR INDOOR USE ONLY.
Upon receipt, inspect the vender for any shipping
damage. If there is any damage have the driver
note the damage on the bill of lading and notify
Dixie-Narco. Although the terms of sale are FOB
shipping point, which requires the consignee to
originate shipping damage claims, Dixie-Narco will
gladly help if you must file a claim.
UNPACKING THE VENDERS
Remove the stretch wrap fiberboard edge protectors
and corrugated front protector from the outside of
the vender.
DO NOT STORE THE VENDER
OUTSIDE WITH THE STRETCH
WRAP ON. THIS COULD CAUSE
THE STRETCH WRAP TO BOND
TO THE VENDER’S SURFACE,
WHICH COULD DAMAGE THE
FINISH.
Remove the shipping boards from the bottom of the
vender. The shipping boards are attached by the
leveling legs. To avoid unnecessary damage to the
leveling legs or base, remove shipping boards by
using a 1 – ½ inch socket type wrench to unscrew
the leveling legs. Be sure to replace the legs after
removing the shipping boards. Once the vender is
unpacked, check the service area for any additional
parts, price/product labels, service/operation
manual, or other information concerning factoryequipped accessories such as coin mechs and
validators.
WARNING: TO AVOID THE
POSSIBILITY OF A FIRE HAZARD, DO
NOT STORE ANYTHING OR ALLOW
DEBRIS OF ANY KIND TO
ACCUMULATE IN THE BOTTOM OF THE
SERVICE AREA, IN AND AROUND THE
REFRIGERATION COMPARTMENT OF THE
CABINET, OR IN FRONT OF THE EVAPORATOR
AND CONDENSER COILS.
ELECTRIC POWER NEEDED
Refer to the cabinet serial number plate to determine
the proper voltage and frequency the machine
requires (domestically this requirement is 120 Volts,
DO NOT USE AN EXTENSION CORD.
GROUND THE VENDER
The vender is equipped with a three wire power
supply cord and MUST be plugged into a properly
grounded outlet.
DO NOT REMOVE THE GROUND
PIN OR IN ANY WAY BYPASS,
MODIFY, DEFEAT, OR DESTROY
THE GROUNDING SYSTEM OF
THE VENDER.
If the outlet will not accept the power cord plug,
contact an electrician to install a proper AC outlet.
FAILURE TO COMPLY WITH
THESE INSTRUCTIONS MAY
SUBJECT THE USER TO THE RISK
OF INJURY OR ELECTRICAL
SHOCK WHICH CAN BE SERIOUS
OR FATAL.
COIN CHANGERS & OTHER
ACCESSORIES
The vender must have an MDB coin changer
installed and can have an MDB bill acceptor
installed. If the MDB coin changer and other MDB
accessories are not factory installed, refer to the
instructions received from the manufacturer of the
MDB coin changer and other MDB accessories for
proper set-up and installation.
The Vender will support the following MDB coin
changers:
Multi-Drop Coin Mech (Domestic)
Coinco 9302GX Conlux CCM-5G
Mars TRC6510
Mars TRC 6512
The Vender will support the following MDB bill
validators:
Multi-Drop Bill Validators (Domestic)
Coinco BA30B, BA50, MAG30, MAG50
Mars VN2512, VN2502, VN2312
Conlux NBM-3000 Series, MKA-2141-11
Ardac 5500 Series
Page 5
INSTALLATION & SETUP
5
of 90
The Vender will support the following MDB card
readers:
Multi-Drop Card Readers (Domestic)
Debitek Smart Card - MDB
Danyl Schlumberger
(At publication swipe reader had not
been tested)
Fage MDB
Diebold Systems
AT&T Campus Wide
VMC LTD
Jofemar
Evend.net
PLACING THE VENDER ON LOCATION
The Coca-Cola Glass Front Vender is for INDOOR
USE ONLY. It should be kept out of direct sunlight
and away from any heat source.
!! CAUTION !!
DO NOT TRANSPORT THE
VENDER TO OR FROM THE
LOCATION LOADED WITH
PRODUCT OR DAMAGE TO THE
VENDER MAY RESULT. ENSURE
TRAY ASSEMBLIES ARE
SECURED WHEN MOVING THE
VENDER OR DAMAGE TO THE
VENDER MAY RESULT.
The vender must be located on a solid, flat, and
level surface. Ensure the flooring can bear the
weight load of a fully stocked vender (approximately
1150 lbs. DN5000 or 1012lbs. DN3000). The vender
must be positioned close enough to an electrical
outlet so that an extension cord is not required. If
the machine will be subject to user misuse or
vandalism, it is recommended that the vender be
secured to the floor or wall as described in DixieNarco Technical Bulletin 344. Due to the large size
and weight of the vender, never attempt to move the
vender with a hand truck or stair climber. The
vender should be moved with a Pallet Jack or
Vender/Cooler Dolly at all times. The vender should
never be slid or pushed in place. Never side load
the leveling legs, doing so will damage the legs.
LEVEL THE VENDER
Adjust the front leveling legs, ensuring that an even
gap exists between the glass door and the top
security angle and receiver box, then level the
cabinet front-to-rear. A carpenter’s level will help
verify that the machine is level. Leveling legs are
adjusted using a wrench or socket 1 – ½ inch in
size. Lowering the legs will raise the machine
approximately 1/4” per 4 turns. If the machine is to
be used next to another vender, check the top and
side for proper alignment. Minimum leg extensions
should be used in leveling and alignment to attain
greater stability. Make sure that all the leveling legs
are in contact with the floor. If you cannot level the
vender, select another location. Do not place any
objects under the machine.
Leveling is extremely important to ensure proper
vender operation.
DANGER
The vender must be properly located
and leveled. If the machine will be
subject to user misuse or vandalism
it is recommended that the vender be
secured to the floor or wall as
described in Dixie-Narco Technical
Bulletin 344 to minimize risk of injury
or death from tipping. Call the DixieNarco Technical Service Department
or your local Dixie-Narco
Representative for assistance.
SPACE THE VENDER
Do not block the rear of the vender. Keep the
vender 4 inches (10 cm) from the wall to ensure
adequate airflow to the condenser and compressor.
At the front of the vender, make sure that nothing
obstructs the air intake at the bottom of the service
door and cabinet. At the rear of the vender, make
sure nothing obstructs the air exhaust at the bottom
of the cabinet.
WARNING: TO AVOID THE
POSSIBILITY OF A FIRE HAZARD, DO
NOT STORE ANYTHING OR ALLOW
DEBRIS OF ANY KIND TO
ACCUMULATE IN THE BOTTOM OF THE
SERVICE AREA, IN AND AROUND THE
REFRIGERATION COMPARTMENT OF THE
CABINET, OR IN FRONT OF THE EVAPORATOR
AND CONDENSER COILS.
LOADING THE VENDER
All Coca-Cola Glass Front venders are shipped
ready to vend 20 oz. bottles unless another package
was specified at the time the vender was ordered
from the factory. If a package other than these are
to be vended, contact a Dixie-Narco Factory Service
Representative or refer to the proper Technical
Publication for spacer settings.
PRODUCT
The Coca-Cola Glass Front Vender is designed to
vend a wide range of cans, glass, and plastic
beverage containers in sizes from 12 oz. to 20 oz. It
has a double-pane or triple pane, tempered safety
Page 6
INSTALLATION & SETUP
6
of 90
glass door for clear viewing of all products. The
machine is set up with: 5 Trays, 9 columns or 6
columns each, 8 products per column. Maximum
capacity for DN5000 is 15 cases (360 items) of 20
oz. Product and DN3000 is 10 cases (240 items) of
20oz. product.
•Locate the KO control board mounted on the
right side wall.
•Remove the battery from its holder (B 1).
LOADING
INSTALLATION AND SETUP
INSTRUCTIONS
Open the service door on the right side using the
key provided in the coin return cup, or if shipped with
a locking clip, remove the clip and install the lock.
Ensure the power switch on the AC distribution box
is in the off position.
Check that all connectors are firmly seated on the
control boards and at the various components on the
service door (coin mech, keypad, etc.).
Retrieve the main power plug from the hole in the
rear of the vender and plug the cord in a properly
grounded 120VAC, 15 Amp receptacle (U.S. and
Canada).
Open the service door and apply power to the AC
distribution box by means of the rocker switch (if
equipped with a bill acceptor, the acceptor should
cycle twice). The display on the door should scroll
“*/SOFTWARE/REV###.##/ICE COLD COCACOLA/##.##”, fluorescent lamp should be lit and the
cooling unit should start. (Note: There is an
approximate 2 minute delay)
IF THE DISPLAY SCROLLS “OUT OF SERVICE”,
OR THE COOLING UNIT FAILS TO START,
REFER TO THE TROUBLESHOOTING
FLOWCHARTS BEGINNING ON PAGE 38.
SERVICE NOTE
Battery Backup
The battery backup is used to retain information
programmed in the system (pricing, time, date, etc.)
in case of power interruptions, or any time the main
power is off. When the vender is shipped, the
battery is connected and memory is being
maintained. If the vender is to be stored for long
periods of time, disconnecting the battery is
recommended. The following steps will guide you
through this procedure.
•Open the service door, turn the main power
switch to the off position or unplug the main
power harness located on the front of the power
box.
LOADINGCHANGETUBES
MDB UNITS
Open the service door. Enter “TUBEFILL” in
programming.
Load the coin mechanism with coins by inserting
coins in the separator on the coin mech. Display will
show the total number of the coin type being entered
as they are installed. (i.e. .05 1, .10 3, .25 8).
Note: A low coin level in the coin tubes will
interfere with operation of the bill validator.
(For additional information about coin mechanism
refer to the manufacturer’s instructions.)
LOADINGPRODUCT
Proper product loading and product sizing to
spacer/gate and elevator / conveyor are very
important in ensuring problem free vending. Pay
close attention to the product’s center of gravity.
Regional products are sometimes bottled and/or
canned in unique shapes and sizes. These products
must be tested for problem-free vending before large
quantities are purchased.
Note: Loading should be done as quickly as
possible to minimize product/cabinet
exposure to warmth and humidity.
Open the service door then open the product
compartment glass door.
After loading is finished check the price tags to
ensure they correspond to existing products. Pricing
labels are located in the service bag shipped with
every vender.
Close the product compartment glass door.
Close the service door and lock. Closing the service
door will place the machine in service and start the
refrigeration cycle.
Page 7
PROGRAMMING
7
of 90
PROGRAMMING
COCA-COLA EVS GLASS FRONT PROGRAMMING METHOD
April 2000
NORMAL MODE:
In normal mode, on power up display will show software installed in vender, then change to POS message or
decimal point and / or vend price. When money is inserted, the display indicates the total amount of the deposit.
The keys on the keypad are used to select the product. In normal mode you may access an external menu for
reading historical sales counters, cash counters, error codes, none, or return to normal mode.
SERVICE MODE:
If configuration switch 4 is set to “C4 0”, when the door is opened, “NONE” or a list of Error codes will show on the
display. If configuration switch 4 is set to “C4 1”, when the door is opened, “CASH - ####-##.##”, “CARD - ######.##”, “SALES - #### -####”, “ERROR”, or “NONE” will show on the display. NOTE: Card is only shown if a
card reader is present. The service mode is entered when the door is open and the service switch on the KO
controller is pressed. The operator can now use the keypad to move through the main routine menu.
Key number 1: Abort/Cancel - will return to previous menu prompt.
Key number 2: Scroll Up - forward in menu.
Key number 3: Scroll Down - backward in menu.
Key number 4: Enter/Save/Clear - Allows you to enter a specific routine, save what you have programmed, or
clear the error prompts.
Note: Routines with * are password protected. They can only be viewed and entered after the password is
entered at the “PASS” prompt.
EXTERNAL MENU MODE:
The information available in this mode is obtainable with the door closed or open as long as the vender is in
normal mode, by entering the password which is set at 4, 2, 3, 1. Note: 4231 is the factory default and can be
programmed to any four digit combination. Information available is historical cash counted, resettable cash
counted for each selection, historical sale (total number of vends), resettable vends counted for each selection,
error codes, and return. Refer to the “CASH”, “SALES”, AND “ERROR” routines for instructions to move through
the menus.
PROGRAMMING MENU
“ERROR” - ERROR ROUTINE
This function allows you to enter the error readout routine. ERROR will appear when you press the service button
on the control board. Press key number 4, if there have been no errors since the last reset, the display will read
“NONE”. If one or more errors have occurred, the display will show the first error code that occurred.
The following are error codes that may be displayed and detailed information accessed: “NONE”, “VENDMECH”,
“CONTROL”, “SELECTSW”, “CHANGER”, “BILL VAL”, “CARD RDR”, “ONLINE”, “RVEND”, “SEL/DISP”,
“RFRIG”, “DNC ERR”, “HEALTH”.
Press key number 2 or 3 to scroll through any error codes that are present.
Important: If there is only one problem, that will be the only error code shown when you enter the error code sub-
menus.
With an error code showing on the display, press key number 4 to access detailed information.
After making repairs with an error code showing on the display, press and hold key number 4 for 2 seconds will
clear the error.
Press key number 1 to return to “ERROR”.
Page 8
PROGRAMMING
8
of 90
“VENDMECH” - Vend Mechanism Summary Errors
Press key number 4 and the display will show the following:
- “COLJAM#”, where # is the column number detected jammed.
Press key number 1 will return to “VENDMECH” if all vend mech errors have not been cleared.
If all vend mech errors have been cleared the next error mode will be displayed, or “NONE” if there are no
errors.
Press key number 1 will return to “ERROR”.
“CONTROL” - Control System Summary Errors
Press key number 4 and the display will show one of the following:
- “DOORSWIT”, indicating a door switch in the open position for more than 1 hour.
- “RAM ERR”, indicating the check sum for service mode settings memory has been corrupted.
- “AC LOW”, indicating AC supply to the machine has fallen more than 15% below normal line
voltage for more than 30 seconds.
- “SCALEER”, indicating a peripheral has introduced a scaling factor that is incompatible with current
setting.
Press key number 1 will return to “CONTROL” if all control system errors have not been cleared.
If all control system errors have been cleared the next error code will be displayed, or “NONE” if there are
no errors.
Press key number 1 will return to “ERROR”.
“SELECTSW” - Select Switch Summary Errors
Press key number 4 and the display will show “SELSW#”, indicating a key on the keypad has been active
for more than 15 seconds while in normal (sales) mode.
Press key number 1 will return to “SELECTSW” if all selection errors have not been cleared.
If all selection errors have been cleared the next error code will be displayed or “NONE” if there are no
errors.
Press key number 1 will return to “ERROR”.
“CHANGER” - Changer Summary Errors
Press key number 4 and the display will show one of the following:
- “COINCOMM”, indicating a changer communication error. (No communication for more than 2
seconds)
- “TUBESENS”, indicating a tube sensor error.
- “COININLE”, indicating an inlet chute blocked error (no coins sensed in acceptor for 96 hours).
- “TUBJAM #”, indicating a tube jam error.
- “COIN ROM”, indicating a changer ROM check sum error (failed changer).
- “EXCESSES”, indicating excessive escrow attempts (more than 255 since last coin sensed).
- “COIN JAM”, indicating a coin jam reported by coin mech.
- “LOW ACCP”, indicating a low coin acceptance rate (less than 80%).
- “ACCDISCN”, indicating an acceptor is unplugged.
- “ROUTING”, indicating a coin was mis-routed.
Press key number 1 will return to “CHANGER” if all changer errors have not been cleared.
If all changer errors have been cleared the next error code will be displayed or “NONE” if there are no
errors.
Press key number 1 will return to “ERROR”.
Page 9
PROGRAMMING
9
of 90
“BILL VAL” - Bill Validator Summary Errors
Press key number 4 and the display will show one of the following:
- “BILLCOMM”, indicating a bill validator communication error. (No communication for more than 5
seconds)
- “BILLFULL”, indicating the bill stacker is full.
- “BILL MOT”, indicating a defective motor in the validator.
- “BILL JAM”, indicating a bill jam in the validator.
- “BILL ROM”, indicating a check sum error.
- “BILLOPEN”, indicating an open stacker.
- “BILLSENS”, indicating a bill validator sensor error.
Press key number 1 will return to “BILL VAL” if all changer errors have not been cleared.
If all validator errors have been cleared the next error code will be displayed or “NONE” if there are no
errors.
Press key number 1 will return to “ERROR”.
“CARD RDR” - Card Reader Summary Errors
Press key number 4 and the display will show one of the following:
- “CARDCOMM”, indicating no card reader communication for 5 seconds.
- “CARD #”, indicating the most recent “non-transient error” from the card reader (failed card reader).
Press key number 1 will return to “CARD RDR” if all changer errors have not been cleared.
If all card reader errors have been cleared the next error code will be displayed or “NONE” if there are no
errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
“ONLINE” - Online Module Error
Press key number 4 and the display shows one of the following:
- “ONLINE”, indicating no communications to online module for 5 seconds.
- “ONL COMM”, indicating the online network is not responding, online module cannot call out.
- “ONL INTL”, indicates an online module internal problem causing improper functioning.
Press key number 1 will return to “ONLINE” if all online module errors have not been cleared.
If all online module errors have been cleared the next error code will be displayed or “NONE” if there are
no errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
“RVEND” - Remote Vend Mechanism (USD) Error.
Press key number 4 and the display shows one of the following.
- “RV COMM#”, indicates no communication for 5 seconds with remote vend mech at address “#”.
- “RVEND a#”, indicates error code number “#” from the remote vend mech at address “a”.
Press key number 1 will return to “RVEND” if all remote vend mechanism errors have not been cleared.
If all remote vend mechanism errors have been cleared the next error code will be displayed, or “NONE” if
there are no errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
- “S/D COMM”, indicating no communication to selection / display device for five seconds.
Press key number 1 will return to “SEL/DISP” if all selection / display device errors have not been cleared.
If all selection / display device errors have been cleared the next error code will be displayed or “NONE” if
there are no errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
Page 10
PROGRAMMING
10
of 90
“REFRIG” - Refrigeration Summary Errors
Press key number 4 and the display shows one of the following:
- “TEMPSENS”, indicating the temperature sensor is defective or unplugged.
- “TOO COLD”, indicating the cabinet temperature is 30 F below lower limit.
- “TOO HOT”, indicating the cabinet temperature is 30 F above upper limit.
- “NO COOL”, indicating the cooling system has failed to decrease temperature 10 F per hour while
the compressor is running.
Press key number 1 will return to “REFRIG” if all refrigeration summary errors have not been cleared.
If all refrigeration summary errors have been cleared the next error code will be displayed, or “NONE” if
there are no errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
“DNC ERR” - Dixie-Narco Corporation Summary Errors
Press key number 4 and the display will show one of the following:
- “MB COMM”, indicating the machine board has stopped communicating. The display will scroll “NO
SALE” when this error has occurred.
- “ELEVATOR”, indicating an elevator operation error has occurred.
- “CONVEYOR”, indicating a conveyor operation error has occurred.
- “PORT DR”, indicating the read switch not being recognized at port door.
Press key number 1 will return to “DNC ERR” if all Dixie-Narco Corporation Summary errors have not
been cleared.
If all Dixie-Narco Corporation Summary errors have been cleared the next error code will be displayed or
“NONE” if there are no errors.
Press key number 1 will return to “ERROR”.
Press key number 2 will scroll to the next routine.
“HEALTH” – HEALTH TIMER CONSTRAINT ERRORS
Press key number 4 and the display shows one of the following.
- “HTIN” – Health Timer Error
The initial pull down time has not met the health timer constraints. Refer to “HEALTH” section for details.
Press and hold key number 4 for 2 seconds will clear the error and the display will show “NONE”.
- “HCOD” – Health Code Error
The health code cooling constraints have not been met. Refer to “HEALTH” section for details.
Press and hold key number 4 for 2 seconds will clear the error and the display will show “NONE”.
- “RCHE” – Recheck Error
The extended health timer has not met the health timer constraints. Refer to “HEALTH” section for details.
Press and hold key number 4 for 2 seconds will clear the error and the display will show “NONE”.
“COINPAYO” - COIN PAYOUT ROUTINE
This function allows you to dump coins from the coin mechanism.
Press key number 4 to enter mode and the lowest coin value dispensable will show on the display.
Press key number 2 or 3 to scroll through the different coin values available.
Press and hold key number 4 to dump the coins whose value is shown on the display.
Press key number 1 will return to “COINPAYO”.
Press key number 2 to scroll to the next routine.
“TUBEFILL” - TUBE FILL ROUTINE
This function allows you to count the coins loaded in the top (separator) of the coin mech that will be routed to an inventory
tube. Press key number 4 to enter mode and the total number of the coin type being loaded will be displayed and counted in
the vender controller as they are accepted. The controller will inhibit the acceptance of any coin which does not go to a tube
during this procedure. If a tube full status is detected, that coin type will be inhibited. When you finish loading all coins:
Press key number 1 to return to “TUBEFILL”.
Press key number 2 to scroll to the next routine.
Page 11
PROGRAMMING
11
of 90
“TESTMODE” - TEST ROUTINE
This function allows you to diagnose different functions of the vender.
Press key number 4 and the display will show “TESTVEND”.
Press key number 2 or 3 to scroll through the test routines available.
Press key number 1 to return to “TESTMODE”.
“TESTVEND” - Vend Testing
This function allows you to test vend each column.
Press key number 4 and the display will show “COL A1”.
Press key numbers 2 or 3 to scroll through the columns available to run in motor test.
Press key number 4 to run the motor of the column displayed.
Press key number 1 will return to “TESTVEND”.
Press key number 2 to scroll to next test mode.
“TEST SEL” - Select Switch Test
This function allows you to test each selection.
Press key number 4 and the display will show “SEL 4”. Then press any key and the display will show the
last key number pressed.
Press and hold key number 1 for approximately 5 seconds will return to “TEST SEL”.
Press key number 2 to scroll to the next test mode.
“DISPLAY” - Display Test
This function allows you to test all segments in the display.
Press key number 4 and the display segments will illuminate in the following manner; “*0.” will scroll
continuously.
Press key number 1 to return to “DISPLAY”.
Press key number 2 to scroll to next test mode.
“RELAYS” - RELAY TEST
This function allows you to test the relay electronic control of the compressor (“COMPR #”), the
evaporator fan(s) (“FAN #”), and the sign front light (“LIGHT#”).
CAUTION: Disconnect power to the compressor before testing the compressor relay. Failure to
disconnect power to the compressor before testing the relay could result in damaging the
compressor.
Press key number 4 and the display will show “COMPR#”, where # is the state of the relay 0 = not activated or off; 1 = activated or on . Press key number 4 to toggle the relay on and off.
Press key number 2 to scroll to “FAN#”, where # is the state of the relay - 0 = not activated or off, 1 =
activated or on. Press key number 4 to toggle the fan(s) on and off.
Press key number 2 to scroll to “LIGHT#”, where # is the state of the relay - 0 = not activated or off;
1 = activated or on. Press key number 4 to toggle the lights on and off.
Press key number 1 to return to “TESTMODE”.
Press key number 2 to scroll to “PASSWORD”.
* “PASSWORD” - PASSWORD ROUTINE
This function allows you to enter the following routines which are not accessible until the operator enters a
password, which is set as 4-2-3-1. To enter the password, press key number 4 until the display goes blank. Then
press key number 2, then 3, then 1, and then 4, and “CASH” should appear on the display. If not entered
properly, the display will return to “PASSWORD” after approximately 16 seconds. If entered correctly, the display
will go to the next function “CASH”.
Page 12
PROGRAMMING
12
of 90
* “CASH” - CASH COUNTER ROUTINE
This function will show the user the vender historical total cash counted and the resettable cash counted for each
selection for the vender.
Press key number 4 and “CASH”/”######.##” will show on the display where the 8"#” characters are the historical
total cash counters that have been recorded. Note: Leading zeros are not displayed. Example: Display flashes
“CASH”, then “262500”. This is $2625.00 historical total cash. Press key number 2 to scroll to
“CARD”/######.##”, where the 8# characters are the historical card reader cash counters. Note: Leading zeros
are not displayed.
Press key number 2 or 3 to display “COL A1”/”######.##” where the 8"#” characters are the resettable cash
counters for that selection. Note: Leading zeros are not displayed. Pressing key number 2 or 3 at this time will
scroll through the available selection cash counters. Example: Display flashes “COL A1”, then “520.50”. This is
$520.50 resettable cash for selection A1. Press key number 1 to return to “CASH”/”######.##”. Press key
number 1 to return to “CASH”.
Press key number 2 to scroll to the next routine.
* “SALES” - SALES COUNTER ROUTINE
This function will show the user the vender historical total number of vends and the resettable vends counted for
each selection for the vender.
Press key number 4 and “SALES”/”########” will show on the display where the 8"#” characters are the
historical total vend counters that have been recorded. Note: Leading zeros are not displayed. Example: Display
flashes “SALES”, then “1325”. This is 1325 historical vends.
Press key number 2 or 3 to display “COL A2”/”########”, where the 8"#” characters are the resettable vend
counters for that selection. Note: Leading zeros are not displayed. Pressing key number 2 or 3 at this time will
scroll through the available selection vend counters. Example: Display flashes “COL A1” then “145”. This is 145
resettable vends counted for selection A1. Pressing key number 1 will return to “SALES”/”########”. Press key
number 1 to return to “SALES”.
Press key number 2 to scroll to the next routine.
* “PRICE” - PRICE SETTING ROUTINE
This function allows the user to set pricing. When Configuration Code 1 is programmed to “C1 1”, multi-pricing a
price for each selection needs to be set. Note: This routine is lockable when using a data collection device.
Press key number 4 and “PRICE A1” (multiprice) or “SNGPRICE” (single price) will show on the display.
Press key number 4 to set the price on selection A1, “00.00” or current price setting will show on the display.
Press key number 2 or 3 to change the price setting for selection A1.
Press key number 4 to enter the price selected and the display will return to “PRICE A1”.
Press key number 2 to scroll to the next selection you wish to set price. Press key number 4, set the price and
enter the price. Repeat these steps for each selection until all prices are set. Note: In multiprice modes,
selections go “PRICE A1” through “ALL SELS”.
If Configuration Code 1 is programmed to “C1 O”, single price, set “SNGPRICE” as described above. The price
entered for “SNGPRICE” will be set for all selections.
Press key number 1 to return to “PRICE”.
Press key number 2 to scroll to the next routine.
Page 13
PROGRAMMING
13
of 90
“STS PROG” – SPACE TO SALES ROUTINE
This function allows you to change the space to sale settings. Press key number 4 and “OPTION#” or “CUST
STS” will show on the display, which indicates the current space to sales option. For the 7 options available, see
list below. Press key number 2 to scroll through the options. Press key number 4 with the desired option showing
on the display to save that option and return to “STS PROG”.
Space to Sales Options:
“OPTION1” 1 to 1 = Columns are assigned to selections with the same number.
“OPTION2” Tray = Full tray assigned. Example: selections A1 thru A9 vend from columns A1 thru A9
sequentially.
“OPTION3” Half Tray = Half tray assigned. Example: selections A1 thru A5 vend from columns A1
thru A5 sequentially and selections A6 thru A9 vend from columns A6 thru A9
sequentially.
“OPTION4” Groups of 3 = Groups of 3 columns are assigned sequentially to work with associated
selections. Example: selections A1 thru A3 vend from columns A1 thru A3 sequentially.
“OPTION5” Combined groups of 2 & 3 = Selection grouping per tray will be assigned columns 1 & 2;
3 & 4; 5 & 6; 7, 8, & 9 working with associated selections.
“OPTION6” Combined groups of 3 = Selection grouping per tray will be assigned columns 1, 2, & 3;
4, 5, & 6; 7, 8, & 9 working with associated selections.
“CUST STS” Custom space to sales = Allows you to assign columns in blocks working with associated
selections.
With “CUST STS” showing, press key number 4 and “CLEAR?” will show on display. Press key number 4 will
clear the current space to sale settings. Press key number 1 will return to “CUST STS”.
Press key number 4 will show “SEL A1” alternating with columns assigned to blocks. Press key number 4 will
show “FIRST A1” or the individual selection to start a block.
Press key number 2 to scroll to “FIRST E9” or the largest selection available.
Press key number 4 will show “LAST A1” or the last column for custom space to sales blocks.
Press key number 2 will show “LAST A1” or the largest column for custom space to sales blocks available.
Press key number 4 will show “SAVE?”
Press key number 4 will save the new settings.
IMPORTANT: Selection to Column assignments are only for each Tray. Example: Selection A1 can only be tied
to columns on the A Tray.
Page 14
PROGRAMMING
14
of 90
* “CONFIG” - MACHINE CONFIGURATION
This function allows the user to access and change the programming of the following machine configuration
settings. Note: This routine is lockable when using a data collection device. If you press key number 4 and the
display shows “LOC”, this means configuration setting changes will not be allowed. If “CON 1” is displayed, then
configuration setting changes will be allowed. “LOC” can only be enabled or disabled through DEX interrogation.
If “CON1” is displayed, the listed settings are available. Note: You must press key number 4 with the
configuration code displayed if you wish to enter the edit mode. The “0” or “1” will be flashing to acknowledge you
are in the edit mode.
IMPORTANT: All machine configuration codes are disabled coming from the factory (CON # 0).
CON 1 - Configuration Switch 1 - Multi-Price Setting Mode
This code is used to enable the single price mode “CON 1 0” or multi-price mode “CON 1 1”.
Press key number 4 and “CON 1 #” will be displayed, with the “#” flashing.
Press key numbers 2 or 3 to scroll between “CON 1 0” and “CON 1 1”.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 1”.
Press key number 2 to scroll to “CON 2”.
CON 2 - Configuration Switch 2 - Optional Features Enable
This code is used to allow (CON 2 1) the following optional features to be displayed and enabled:
“LIGHT”, “DISCOUNT”, “OVERRIDE”, “SELBLCK1”, and “SELBLCK2”.
Press key number 4 and “CON 2 #” will be displayed with the # flashing.
Press key numbers 2 or 3 to scroll between “CON 2 0” and “CON 2 1”.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 2”.
Press key number 2 to scroll to “CON 3”.
CON 3 - Configuration Switch 3 - POS Message
This code is used to disable the point of sale message. CON 3 0 = enabled, CON 3 1 = disabled.
Press key number 4 and “CON 3 #” will be displayed, with the “#” flashing.
Press key numbers 2 or 3 to scroll between “CON 3 0” and “CON 3 1”.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 3”.
Press key number 2 to scroll to “CON 4”.
CON 4 - Configuration Switch 4 - Automatic Viewing of Historical Sales and Cash Accounting,
ERROR or NONE
This code is used to enable viewing of historical sales, historical cash, ERROR or NONE automatically
when the door is opened. To enable automatic viewing option enter “CON 4 1”; to disable enter “CON 4
0”.
At “CON 4 0” ERROR or NONE automatically displays when the door is open.
Press key number 4 and “CON 4 #” will be displayed, with the “#” flashing.
Press key number 2 or 3 to scroll between “CON 4 0” and “CON 4 1”.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 4”.
Press key number 2 to scroll to “CON 5”.
CON 5 - Configuration Switch 5 - Door Switch Reset Status
This code is used to reset all resettable data when the door switch is cycled and at least one data register
is read via the display when set at “CON 5 1” or to reset all resettable data only when the “RESET”
command is received via handheld or portable computer when set at “CON 5 0”.
Press key number 4 and “CON 5 #” will be displayed, with the “#” flashing.
Press key numbers 2 or 3 to scroll between “CON 5 0” and “CON 5 1”.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 5”.
Press key number 2 to scroll to “CON 6”.
Page 15
PROGRAMMING
15
of 90
CON 6 - Configuration Switch 6 - Reserved
This code is reserved for future use.
Press key number 2 to scroll to “CON 7”.
CON 7 - Configuration Switch 7 - Save Credit
This code is used to determine how long a credit will be saved.
C7 0 will save the credit for five minutes. CON 7 1 will save the credit indefinitely.
Press key number 4 and “CON 7 #” will be displayed, with the “#” flashing.
Press key number 2 or 3 to scroll between CON 7 0 and CON 7 1.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 7”.
Press key number 2 to scroll to “CON 8”.
CON 8 - Configuration Switch 8 - Force Vend
This code is used to determine escrow to select or escrow to price.
CON 8 0 will set vender to escrow to select and CON 8 1 will set vender to escrow to price.
Press key number 4 and “CON 8 #” will be displayed, with the “#” flashing.
Press key number 2 or 3 to scroll between CON 8 0 and CON 8 1.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 8”.
Press key number 2 to scroll to “CON 9”.
CON 9 - Configuration Switch 9 - Multi Vend
This code is used to allow multiple vends without re-depositing funds.
CON 9 0 will not allow multiple vends and CON 9 1 will allow multiple vends.
Press key number 4 and “CON 9 #” will be displayed, with the “#” flashing.
Press key number 2 or 3 to scroll between CON 9 0 and CON 9 1.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 9”.
Press key number 2 to scroll to “CON 10”.
CON 10 - Configuration Switch 10 - Bill Escrow Inhibit
This code is used to allow last bill that meets or exceeds maximum vend price to be held in escrow.
CON 10 0 will escrow bill and CON 10 1 will not escrow bill (or stack the bill).
Press key number 4 and “CON 10 #” will be displayed, with the “#” flashing.
Press key number 2 or 3 to scroll between CON 10 0 and CON 10 1.
Press key number 4 with the display flashing the setting you wish to use.
Press key number 1 to return to “CON 1 0”.
Press key number 2 to scroll to the next configuration code.
Press key number 1 to return to “CONFIG”.
Press key number 2 will scroll to next routine.
Page 16
PROGRAMMING
16
of 90
*”CHANGE” - CORRECT CHANGE ONLY CONTROL ROUTINE
This function is used to allow consumer overpay, set a correct change value, and set an unconditional acceptance
value.
Press key number 4 will enter “CONOVER#”.
“CONOVERX” - Allow Consumer Overpay
This function allows the vender to vend with the risk of not being able to return the full amount of change.
This function has to be turned on to be able to allow consumer overpay.
Press key number 4 and display will show “CONOVER#”, where “#” is flashing.
CONOVER1 will allow consumer overpay (customer could potentially be shortchanged) and
“CONOVER0” will not allow consumer overpay (will not allow customer to be shortchanged).
Press key number 2 or 3 to scroll between CONOVER0 and CONOVER1.
Press key number 4 with the display blinking the setting you wish to use. Display will return to
“CONOVER#”.
Press key number 2 to scroll to “CORR CHG”.
“CORR CHG” - Correct Change Value
This is the function that the control board will use to set a value which will turn on the correct change
indicator. Note: If “ACCEPT” is set, the “CORR CHG” should be equal to or less than the “ACCEPT”.
Note: If the value set is 00.00, the correct change indicator will never come on.
If the controller determines that it cannot return the exact amount of the correct change value or any value
less than it, then the indicator will be turned on.
Press key number 4 and the display will show “##.##’.
Press key number 2 or 3 to scroll from 00.00 to 99.99.
Press key number 4 with the display showing the value you wish to use. Display will return to “CORR
CHG”
Press key number 2 to scroll to “ACCEPT”.
“ACCEPT” - Unconditional Acceptance Value
This is the function that the control board will use to set the largest value of any single form or currency
(coin or bill) that can be accepted without having enough change to pay back the full amount.
Press key number 4 and the display will show “##.##”.
Press key number 2 or 3 to scroll from 00.00 to 99.95.
Press key number 4 with the display showing the value you wish to use. Display will return to “ACCEPT”.
Press key number 1 to return to “CHANGE”.
Press key number 2 to scroll to next routine.
*”PREVIEW” - PREVIEW DATA PASSWORD ROUTINE
This function is used to enable viewing of cash collected, product sales, and error codes without opening the
door. To view the data the 4 digit password (4-2-3-1) must be entered. Once entered the “CASH”, “SALES”,
“ERROR”, and “RETURN” menus are available from the front of the vender. To view, follow instructions for cash
counter routine, sales counter routines, error routine and return.
To change “PREVIEW” password:
At “PREVIEW” press key number 4, “####” (representing current four digit password) will show on display with the
far left digit blinking. Press key number 2 to scroll to number desired for password. Press key number 4. The
next digit will start blinking, press key number 2 to scroll to number desired for password. Press key number 4.
Continue this process until all 4 digits are set. Then press key number 4 and the display will return to “PREVIEW”
and the new password has been saved. Pressing key number 1 at anytime during this routine will return to
“PREVIEW” with no changes to password occurring.
Press key number 2 to scroll to next routine.
Page 17
PROGRAMMING
17
of 90
*”LANGUAGE” - LANGUAGE ROUTINE
This function is used to set the language that will be used for display messages. Note: This does not change the
menu prompts.
Press key number 4 and the display will show the language currently set in the controller.
Press key number 2 or 3 to scroll through the languages available.
ENGLISH - English ITALIAN - Italian SLOVENE - Slovene
FRENCH - French PORTUGES - Portuguese FINNISH - Finnish
GERMAN - German SPANISH - Spanish NORWEG - Norwegian
With the language you wish to enter showing on the display, press key number 4.
The display will return to “LANGUAGE”.
Press key number 2 to scroll to next routine.
*”TIME” - TIME AND DATE SETTING ROUTINE
This function is used to set the year, month, date, and hour (military 24 hour clock).
Press key number 4 and “ENABLE X” will show on display.
“ENABLEX” - Time and Date Enable Routine
Press key number 4 and ENABLE0 = disabled or ENABLE1 = enabled will show on display.
Press key number 2 to scroll between ENABLE0 and ENABLE1.
Press key number 4 with the display showing the setting you wish to use and display will return to
“ENABLEX”.
Press key number 2 to scroll to “YEAR”.
“YEAR” - Year Setting (00 to 99)
Press key number 4 and the current year setting will show on display.
Press key number 2 or 3 to change the last 2 digits of the year (00 to 99).
Press key number 4 with the display showing the year you wish to use and display will return to “YEAR”.
Press key number 2 to scroll to “MONTH”.
“MONTH” - Month Setting (01 to 12)
Press key number 4 and the current 2 digit month setting will show on display.
Press key number 2 or 3 to change the month (01 to 12).
Press key number 4 with the display showing the month you wish to use and display will return to
“MONTH”.
Press key number 2 to scroll to “DATE”.
“DAY” - Day of Month Setting (1 to 31)
Press key number 4 and the current 2 digit day of month setting will show on display.
Press key number 2 or 3 to change the day of month (1 to 31).
Press key number 4 with the display showing the day you wish to use and display will return to “DAY”.
Press key number 2 to scroll to “HOUR”.
“HOUR” - Hour and Minute Setting (0000 to 2359)
Press key number 4 and the current 4 digit hour and minute setting will be displayed (24 hour).
The hour setting will be blinking to indicate it can be changed. Press key number 2 or 3 to change the
hour setting. Press key number 4 to save and the minute setting will start blinking to indicate it can be
changed. Press key number 2 or 3 to change the minute setting. Press key number 4 will save and
return display to “HOUR”.
Press key number 2 to scroll to “DST”.
Page 18
PROGRAMMING
18
of 90
“DST” - Daylight Saving Time Setting
This function is used to set the preferred daylight savings time setting.
Press key number 4 will display the current setting.
Press key number 2 or 3 to scroll through the “DST” options listed:
- “OFF”, no daylight savings time changes made.
- “AUSTRAL”, Australian rules - Set forward 1 hour at 1:00 am on the first Sunday in October; Set
backward 1 hour at 1:00 am on the last Sunday in March.
- “EUROPE”, European rules - Set forward 1 hour at 1:00 am on the last Sunday in March; Set
backward 1 hour at 1:00 am on the last Sunday in October.
- “NAMERICA”, North American rules - Set forward 1 hour at 2:00 am on the first Sunday in April;
Set backward 1 hour at 2:00 am on the last Sunday in October.
Press key number 4 with the display showing the setting you wish to use and display will return to “DST”.
Press key number 1 to return to “TIME”.
Press key number 2 to scroll to next routine.
*”LIGHTING” - LIGHTING CONSERVATION CONTROL ROUTINE (Con 2 Must Be Enabled - C2 1)
This function is used to turn the lights off and on during certain periods of the day.
Press key number 4 will enter “ENABLE X”.
“ENABLEX” - Lighting Conservation Control Enable Routine
This function is used to disable Lighting Conservation Control “ENABLE0” (lights will be on at all times) or
enable Lighting Conservation Control “ENABLE1” (lights can be set to turn off).
Press key number 4 and the current “ENABLEX” setting will be displayed.
Press key number 2 or 3 to scroll between “ENABLE0” and “ENABLE1”.
Press key number 4 with the display showing the setting you wish to use.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Lighting Conservation Setting (lights off)
This function is used to set the days and time to start light conservation when “ENABLE 1” is selected.
Press key number 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day to Start Setting
This function is used to set the days of the week to start light conservation.
Press key number 4 and “XXXXXX#” will show on the display, where XXXXXX will be the day of the
week (i.e. MONDAY, TUEDAY, WEDDAY, THUDAY, FRIDAY, SATDAY, SUNDAY, EVRDAY) and #
is 0 = disable, 1 = enable. With the display showing the day you wish to set press key number 4.
The # will start blinking. Press key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1”.
Press key number 4 with the display showing the setting you wish to use. Display will return to
“XXXXXX#”.
Press key number 2 to scroll to the next day to set or press key number 1 to return to “STRT DAY”.
Press key number 2 to scroll to “STRT HR”.
“STRT HR” - Start Hour and Minute Setting
This function is used to set the hours to start light conservation (lamps off).
Press key number 4 and “hhmm” will show on the display, where “hh” is the hour (military time) and
“mm” is the minute. “hh” will be blinking, indicating the hour setting may be changed. Press key
number 2 to scroll from 00 to 23. With the display showing the hour you wish to start light
conservation, press key number 4. “mm” will start blinking, indicating the minute setting may be
changed. Press key number 2 to scroll from 00 to 59. With the display showing the minute you wish
to start light conservation, press key number 4. The display will return to “STRT HR”.
Press key number 1 to return to “STRT TIM”.
Press key number 2 to scroll to “STOP TIM”.
“STOP TIM” - Stop Light Conservation Setting (lights on)
This function is used to set the days and time to stop light conservation.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day To Stop Setting
This function is used to set the days of the week to stop light conservation and can be set in the same
manner as Day to Start Setting.
Page 19
PROGRAMMING
19
of 90
“STOP HR” - Stop Hour and Minute Setting
This function is used to set the hours and minutes to stop light conservation and can be set in the
same manner as Start Hour and Minute Setting.
Press key number 1 to return to “STOP TIM”.
Press key number 1 to return to “LIGHTING”.
Press key number 2 to scroll to next routine.
*”REFRIG” - REFRIGERATION ROUTINE
This function is used to electronically control the refrigeration operations of the vender. Press key number 4 will
enter “ENABLE X”.
“ENABLE X” - Energy Conservation Enable Routine
This function is used to disable Energy Conservation “ENABLE 0” or enable Energy Conservation
“ENABLE 1”. When enabled the cabinet temperature will be allowed to rise to the programmed storage
level (“STORAGE”) during the following programmed time blocks.
Press key number 4 and the current “ENABLE X” setting will be displayed.
Press key number 2 or 3 to scroll between “ENABLE 0” and “ENABLE 1”.
Press key number 4 with the display showing the setting you wish to use.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Energy Conservation
This function is used to set the days and time to start Energy Conservation when “ENABLE1” is selected.
Press key number 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day to Start Setting
This function is used to set the days of the week to start Energy Conservation.
Press key number 4 and “XXXXXX#: will show on the display, where XXXXXX will be the day of the
week (i.e. MONDAY, TUESDAY, WEDDAY, THUDAY, FRIDAY, SATDAY, SUNDAY, EVRDAY) and
# is 0 = disable, 1 = enable. With the display showing the day you wish to set press key number 4.
The # will start blinking. Press key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1”.
Press key number 4 with the display showing the setting you wish to use. Display will return to
“XXXXXX#”. Press key number 2 to scroll to the next day to set or press key number 1 to return to
“STRT DAY”.
Press key number 2 to scroll to “STRT HR”.
“STRT HR” - Start Hour and Minute Setting
This function is used to set the hours to start Energy Conservation.
Press key number 4 and “hhmm” will show on the display, where “hh” is the hour (military time) and
“mm” is the minute. “hh” will be blinking, indicating the hour setting may be changed. Press key
number 2 to scroll from 00 to 23. With the display showing the hour you wish to start Energy
Conservation, press key number 4. “mm” will start blinking, indicating the minute setting may be
changed. Press key number 2 to scroll from 00 to 59. With the display showing the minute you wish
to start Energy Conservation, press key number 4. The display will return to “STRT HR”.
Press key number 1 to return to “STRT TIM”.
Press key number 2 to scroll to “STOP DAY”.
“STOP TIM” - Stop Energy Conservation
This function is used to set the days and time to stop energy conservation when “ENABLE 1” is selected.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day to Stop Setting
This function is used to set the days of the week to stop energy conservation and can be set in the
same manner as “STRT DAY” and “STRTHR”.
“STOP HR” - Stop Hour and Minute Settings
This function is used to set the hours and minutes to stop energy conservation and can be set in the
same manner as “START HR”.
Press key number 1 to return to “STOP TIM”.
Press key number 2 to scroll to “DEGREES”.
Page 20
PROGRAMMING
20
of 90
“DEGREES” - Degree Fahrenheit / Celsius Setting Routine
This function is used to set the degree reading to Fahrenheit (DEGREESF) or Celsius (DEGREESC).
Press key number 4 and “DEGREESX”, where the current setting (X) will be blinking. Press key number
2 or 3 to scroll between DEGREESF and DEGREESC.
Press key number 4 with the display blinking the setting you wish to use.
Press key number 1 to return to “DEGREES”.
Press key number 2 to scroll to “SETPOINT”.
“SETPOINT” - Set Point Control Routine (Default Temperature 35.00 F / 1.50 C)
This function is used to set the average product temperature for initial pull down and reload recovery.
Press key number 4 and “tt.tx” will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is
the degrees.
Press key number 2 to increase or 3 to decrease the number by 10 F or 0.50 C. With the display showing
the set point temperature you wish to use, press key number 4.
Press key number 2 to scroll to “STORAGE”.
“STORAGE” - Storage Setting Routine (Default Temperature 60.00 F / 15.50 C)
This function is used to set the temperature for product storage and is used when Energy Conservation is
enabled.
Press key number 4 and “tt.tx” will show on display when X is F (Fahrenheit) or C (Celsius) and tt.t is the
degrees.
Press key number 2 to increase and 3 to decrease the number by 10 F or 0.50 C. With the display showing
the storage setting you wish to use, press key number 4.
Press key number 2 to scroll to “DISPLYX”.
“DISPLYX” - POS Temperature Display Enable Routine
This function is used to enable the POS Temperature to be displayed following the “ICE COLD COCA
COLA” POS message.
Press key number 4 and “ DISPLYX” will show on the display where x is the current setting. With “X”
blinking, press key number 2 or 3 to scroll between “DISPLY0” disabled or not displayed and “ DISPLY1”
enabled or displayed. With the display showing the setting you wish to use, press key number 4.
Press key number 1 to return to “REFRIG”.
Press key number 2 to scroll to next routine.
*”SELBLCK1" - BLOCK SELECTION BANK 1 ROUTINE (CON 2 must be enabled - C2 1)
This function is used to set selections which will be blocked during certain periods of the day.
Press key number 4 will enter “ENABLE X”.
“ENABLEX” - Blocking Enable Routine
This function is used to disable blocking “ENABLE0” or enable blocking “ENABLE1”.
When enabled, active selections will not be allowed to vend on the days and times programmed.
Press key number 4 and the current “ENABLE” setting will be displayed.
Press key number 2 or 3 to scroll between “ENALBE0” and “ENABLE1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “ENABLEX”.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Selection Blocking Routine
This function is used to set the day(s) and time to start selection blocking.
Press key number 4 and “STRT DAY” will show on the display.
Page 21
PROGRAMMING
21
of 90
“STRT DAY” - Day of Week Start Setting
This function is used to set the day(s) of the week to start selection blocking.
Press key number 4 and “XXXXXX#” will show on the display, where XXXXXX will be the day of the
week (i.e. MONDAY, TUEDAY, WEDDAY, THUDAY, FRIDAY, SATDAY, SUNDAY, EVR DAY) and #
is 0 = disable, 1 = enable.
With the display showing the day you wish to set press key number 4.
The # will start blinking. Press key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1.”
Press key number 4 with the display showing the setting you wish to use.
Display will return to “XXXXXX#’.
Press key number 2 to scroll to the next day to set or press key number 1 to return to “STRT DAY”.
Press key number 2 to scroll to “STRT HR”.
“STRT HR” - Start Hour and Minute Setting
This function is used to set the hours and minutes to start selection blocking.
Press key number 4 and “hhmm” will show on the display, where hh is the hour (military time) and
mm is the minute. “hh” will be blinking, indicating the hour setting may be changed.
Press key number 2 to scroll from 00 to 23. With the display showing the hour you wish to start
selection blocking, press key number 4. “mm” will then start blinking, indicating the minute setting
may be changed.
Press key number 2 to scroll from 00 to 59. With the display showing the minute you wish to start
selection blocking, press key number 4. The display will return to “STRT HR”.
Press key number 1 to return to “STRT TIM”.
Press key number 2 to scroll to “STOP TIM”.
“STOP TIM” - Stop Selection Blocking Routine
This function is used to set the day(s) and times to stop selection blocking.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day of Week Stop Setting
This function is used to set the days of the week to stop selection blocking and can be set in the
same manner as Day of Week Start Setting.
“STOP HR” - Stop Hour and Minute Setting
This function is used to set the hours and minutes to stop selection blocking and can be set in the
same manner as Start Hour and Minute Setting.
Press key number 1 to return to “STOP TIM”.
Press key number 2 to scroll to “SELECT”.
“SELECT” - Selection To Be Affected By Blocking
This function is used to set selection(s) which will be blocked during certain periods of the day.
Press key number 4 and “SELA1#” will be displayed, where # is the current setting for the selection
number displayed. 0 = disabled; 1 = enabled.
Press key number 2 to scroll to the key number setting you desire to change.
Press key number 4 with the key number showing you wish to change (i.e. SELA1#) and the # will start
blinking.
Press key number 2 or 3 to scroll between SELA1 0 and SELA1 1.
Press key number 4 with the display showing the setting you wish to use.
Display will return to SELA1#.
Press key number 1 to return to “SELECT”.
Press key number 2 to scroll to “LIGHT”.
Page 22
PROGRAMMING
22
of 90
“LIGHTX” - Lighting / P.O.S. Display Control
This function is used to turn the lights (if supported) and P.O.S. Display Message off during selection
blocking period 1. 0 = disable or on; 1 = enable or off.
Press key number 4 and the “#” will start flashing.
Press key number 2 or 3 to scroll between “LIGHT0” and “LIGHT1”.
Press key number 4 with the display showing the setting you wish to use.
Display will return to “LIGHTX”.
Press key number 1 to return to “SELBLCK1”.
Press key number 2 to scroll to “SELBLCK2”.
*”SELBLCK2" - BLOCK SELECTION BANK 2 ROUTINE
This function is a second set used to set selection(s) which will be blocked during certain periods of the day.
Press key number 4 will enter “ENABLEX”.
“ENABLEX” - Blocking Enable Routine.
Set this function using instruction for “ENABLEX” in “SELBLCK1”.
“STRT TIM” - Start Selection Blocking Routine
This function is used to set the day(s) and times to start selection blocking.
Press selection button 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day of Week Start Setting
Set this feature using instructions for “SELBLCK1”, “STRT TIM”, “STRT DAY”.
“STRT HR” - Start Hour and Minute Setting
Set this function using instructions for “SELBLCK1”, “STRT TIM”, “STRT HR”.
“STOP TIM” - Stop Selection Blocking Routine.
This function is used to set the day(s) and times to stop selection blocking.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day of Week Stop Setting
Set this function using instructions for “SELBLCK1”, “STOP TIM”, “STOP DAY”.
“STOP HR” - Stop Hour and Minute Setting
Set this function using instructions for “SELBLCK1”, “STOP TIM”, “STOP HR”.
Press key number 1 to return to “STOP TIM”.
Press key number 2 to scroll to “SELECT”.
“SELECT” - Selection To Be Affected By Blocking
This function is used to set selection(s) which will be blocked during certain periods of the day.
Set this function using instructions for “SELBLCK1”, “SELECT”.
Press key number 1 to return to “SELECT”.
Press key number 2 to scroll to “LIGHTX”.
“LIGHTX” - Lighting / P.O.S. Display Control
This function is used to turn the lights (if supported) and P.O.S. Display Message off during selection
blocking period 2.
Set this function using instructions for “SELBLCK1”, “LIGHT”.
Press key number 1 to return to “SELBLCK2”.
Press key number 2 to scroll to “DISCOUNT”.
Page 23
PROGRAMMING
23
of 90
*”DISCOUNT” - DISCOUNT SETTING ROUTINE
This function is used to set the day(s) and times to allow discount prices.
Press key number 4 and ENABLE X will show on the display.
“ENABLE X” - Discount Setting Enable Routine
This function is used to disable discounting “ENABLE 0” or enable discounting “ENABLE 1”.
Press key number 4 and the current “ENABLE X” setting will be displayed.
Press key number 2 or 3 to scroll between “ENABLE 0” and “ENABLE 1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “ENABLE X”.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Discount Pricing
This function is used to set the day(s) and times to start discount prices.
Press key number 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day of the Week Start Setting
Set this feature using instructions for “SELBLCK1”, “STRT TIM”, “STRT DAY”.
“STRT HR” - Start Hour and Minute Settings
Set this feature using instructions for “SELBLCK1, “STRT TIM”, “STRT HR”.
“STOP TIM” - Stop Discount Pricing
This function is used to set the day(s) and times to stop discount prices.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day to Stop Setting
Set this feature using instructions for “SELBLCK1”, “STOP TIM”, “STOP DAY”.
“STOP HR” - Stop Hour and Minute Setting
Set this function using instructions for “SELBLCK1”, “STOP TIM”, “STOP HR”.
“SELECT” - Selection Affected by Discount Pricing
This function is used to set selection(s) which will be affected by discount prices.
Press key number 4 and “SEL A1 #” will be displayed, where # is the current setting for the selection
number displayed. 0 = disabled, 1 = enabled.
Press key number 2 to scroll to the key number you desire to change.
Press key number 4 with the key number showing you wish to change (i.e. SELA1 #) and the # will start
blinking.
Press key number 2 or 3 to scroll between “SELA10” and “SELA11”.
Press key number 4 with the display showing the setting you wish to use.
Display will return to “SELA11”.
Press key number 1 to return to “SELECT”.
Press key number 2 to scroll to “LESS AMT”.
“LESS AMT” - Discount Amount (Price)
This function is used to set the discount amount (price) for selection(s) and times set. Press key number 4
and “##.##” will be displayed, where “##.##” is the current discount price that is set. Press key number 2
or 3 to change the price (00.00 to 99.99).
Press key number 4 with the display showing the price setting you wish to use.
Display will show price.
Press key number 1 to return to “LESS AMT”.
Press key number 1 to return to “DISCOUNT”.
Press key number 2 to scroll to “OVERRIDE”.
Page 24
PROGRAMMING
24
of 90
“OVERRIDE” - MANUAL SWITCH OVERRIDE ROUTINE
This function is used to allow a key switch to override some of the settings stored for normal operations.
This function can be programmed to control one or several of the following features: Free Vend Enable,
Selection Blocking, Discount Pricing, and Lighting Control.
Press key number 4 and the display will show “FREE X”.
Press key number 2 or 3 to scroll through the override routines available.
Press key number 1 to return to “OVERRIDE”.
“FREE X” - Free Vend Enable Routine
This function is used to set the vender to free vend. 0 = disable, 1 = enable.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between “FREE 0” and “FREE 1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “FREE X”.
Press key number 2 to scroll to “NO VENDX”.
“NOVEND X” - No Vend (Vend Override) Enable Routing
This function is used to set vender selections to not be allowed to vend and a “NO SALE” message to be
displayed. 0 = disable, 1 = enable.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between NOVEND 0 and NOVEND 1.
Press key number 4 with the display showing the setting you wish to use. Display will return to
“NOVEND X”.
Press key number 2 to scroll to “BLOCKX”.
“BLOCK X” - Selection Blocking Override Routine
This function is used to override “SELBLCK1” and “SELBLCK2” if they are being used. “BLOCK 0” is
disabled, “BLOCK 1” is enabled.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between “BLOCK 0” and “BLOCK 1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “BLOCK X”.
Press key number 2 to scroll to “DISC X”.
“DISC X” - Discounting Override Routine
This function is used to override “DISCOUNT” if it is being used. “DISC 0” is disabled and “DISC 1” is
enabled.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between “DISC 0” and “DISC 1”
Press key number 4 with the display showing the setting you wish to use.
Display will return to “DISC X”.
Press key number 2 to scroll to “LIGHT X”.
“LIGHT X” - Lighting Control Override Routine
This function is used to override “LIGHT’” if it is being used. “LIGHT 0” is disabled and “LIGHT 1” is
enabled.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between “LIGHT 0” and “LIGHT 1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “LIGHT X”.
Press key number 2 to scroll to “REFRIG X”.
Page 25
PROGRAMMING
25
of 90
“REFRIG X” - Refrigeration Control Override Routine
This function is used to override “REFRIG”, if it is being used. “REFRIG 0” = disabled and “REFRIG 1” =
enabled.
Press key number 4 and “#” will start flashing.
Press key number 2 or 3 to scroll between “REFRIG 0” and “REFRIG 1”.
Press key number 4 with the display showing the setting you wish to use.
Display will return to “REFRIG X”.
Press key number 1 to return to “OVERRIDE”.
Press key number 2 to scroll to “RVNDMECH”.
“RVNDMECH” - REMOTE VEND MECHANISM ROUTINE
This function is used to activate the Universal Satellite Device Control routine.
Press key number 4 to enter routine. If the controller detects a device responding to the remote vend mechanism
address (USD address #3,50H), the vend request commands for this device will be controlled by the following
parameters.
“STRT TIM” - Start Time Setting Routine
This function is used to set the day(s) and time to start the routine.
Press key number 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day of week to start setting
Set this feature using instructions for “SELBLCK1”, “STRT TIM”, “STRTDAY”.
“STRT HR” - Start hour and minute settings
Set this feature using instructions for “SELBLC1”, “STRT TIM”, “STRT HR”.
“STOP TIM” - Stop Time Setting Routine
This function is used to set the day(s) and time to stop the routine.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day of week to stop setting
Set this feature using instructions for “SELBLCK1”, “STOP TIM”, “STOP DAY”.
“STOP HR” - Stop hour and minute settings
Set this feature using instructions for “SELBLCK1”, “STOP TIM”, “STOP HR”.
“SELECT” - Selection Setting Routine
This feature is used to set the selection(s) which will be affected by the Remote Vend Mechanism routine.
Press key number 4 and “SEL A1 #” will be displayed, where # is the current setting for the selection
number displayed. 0 = disabled, 1 = enabled.
Press key number 2 to scroll to the select button number you desire to change.
Press key number 4 with the select button number showing you wish to change (i.e. SEL A1 #) and the #
will start blinking.
Press key number 2 or 3 to scroll between “SEL A1 0” and “SEL A1 1”.
Press key number 4 with the display showing the setting you wish to use.
Display will return to “SEL ## #”.
Press key number 1 to return to “SELECT”.
Press key number 2 to scroll to “VND RATE”.
Page 26
PROGRAMMING
26
of 90
“VND RATE” - Universal Satellite Device (USD) Vend Rate Routine
This function is used to set the vend rate (0-255).
Press key number 4 and the current vend rate (0-255) will show on the display.
Press key number 2 to increase, or 3 to decrease the number in single digit increments.
NOTE: A rate of “0” disables the USD. All other rates, #, will cause a vend command every #’th local
vend.
Press key number 4 with the display showing the vend rate you wish to use and the display will return to
“VND RATE”.
Press key number 1 to return to “RVNDMECH”.
Press key number 2 to scroll to “RETURN”.
“GRABMODE” - GRABMODE SETTING ROUTINE
This function is used to set the Grabmode. When enabled, this mode will vend one time from a column and
cancel credit.
Press key number 4 and “ENABLEX” will show on display.
Press key number 4 and the current “GRABMODE” setting will show on the display (ENABLE0 or ENABLE1) with
the “0” or “1” blinking.
Press key number 2 or 3 to toggle between “ENABLE1” and “ENABLE0”.
ENABLE1 means GRABMODE is turned on and credit will cancel when a column’s vend mech cycles.
ENABLE0 means GRABMODE is disabled and the vender will cancel credit upon product delivery through the
delivery door. This function is set at “ENABLE 0” from the factory.
Press key number 4 with the display showing the GRABMODE setting you wish to use and the display will return
to “ENABLEX”.
Press key number 1, display will return to “GRABMODE”.
Press key number 2 to scroll to “RETURN”.
HEALTH” – HEALTH SETTING ROUTINE
This function is used to enable the health protection feature for product when needed. When enabled it operates
as follows:
1. Cabinet temperature must be maintained at 41 degrees F (5 degrees C) or below for product to be
vended while in normal operation. If the cabinet temperature exceeds 41 degrees F, and fails to return to
41 degrees F or below for 15 minutes the controller will issue a “HCOD” error and disable vending of
health protected products.
2. After door closure, (refill or service) the machine has 30 minutes to pull down to 45 degrees F (7 degrees
C). If the machine has not reached 45 degrees F (7 degrees C) after 30 minutes the controller will issue
a “HTIN” error. Once a health time error is activated the controller will not allow product to be delivered.
After 30 minutes if the temperature is 45 degrees F or less, but not 41 degrees F the controller will set a
15 minute timer. During this time, if the cabinet temperature falls below 41 degrees F (5 degrees C) the
controller will allow health guarded product to be delivered. If the temperature doesn’t fall below 41
degrees F (5 degrees C) the controller will issue a “HCOD” error and disable vending of health protected
products.
3. Power loss for 30 minutes or longer will result in automatic “HCOD” error activation and disable vending
of health protected products upon power up.
4. Power loss less than 30 minutes. Once the machine regains power, if the cabinet temperature is 45
degrees F (7 degrees C) or less the controller will allow product to be dispensed. The controller will allow
an additional 15 minutes for the temperature to pull down to 41 degrees F (5 degrees C). If the
temperature doesn’t reach 41 degrees F (5 degrees C) or less after the 15 minute period the controller
will issue a “HCOD” error and disable vending of health protected products. If the temperature is greater
than 45 degrees F (7 degrees C) on power up the controller will automatically set a “HCOD” error and
disable vending of health protected products.
5. Power loss less than 15 minutes. On power up the controller will allow vending. If the cabinet
temperature doesn’t reach 41 degrees F (5 degrees C) or less in 15 minutes the controller will issue a
“HCOD” error and disable vending of health protected products.
Page 27
PROGRAMMING
27
of 90
To enable, with “HEALTH” on display press key number 4 will enter “ENABLE X”.
“ENABLE X” – Health Enable Routine
This function is used to enable the Health Protection feature. When enabled, protected selections will
only be allowed to vend if health constraints listed above are met.
Press key number 4 and the current “ENABLE” setting will be displayed.
Press key number 2 or 3 to scroll between “ENABLED 0” and “ENABLED 1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “ENABLED X”.
Press key number 2 to scroll to “SELECT”.
“SELECT” – Selection(s) To Be Affected By Health Protection
This function is used to set selection(s) which will be protected by the Health Protection constraints.
Press key number 4 and “ALL SELECTS” will be displayed. Press key number 2 to scroll through “ALL
SELECTS, A, B, C, D, and E”. Press key number 4 with the setting you wish to enter. Selecting “A, B, C,
D, or E” will allow you to chose settings for that tray. Example: With “A” showing on display press key
number 4. Display will show “A ALL SELECTS #”, press key number 2 to scroll through “A ALL
SELECTS #, SEL A1 #, SEL A2 #, SEL A3 #, etc… With the setting you wish to change press key
number 4 and the # will start blinking. Press key number 2 to scroll between “0” disabled and “1”
enabled. With the setting you wish to use showing on the display press key number 4. Display will return
to “A ALL SELECTS # or SEL A# #”.
Press key number 1 to return to “SELECT”.
Press key number 2 to scroll to “RECHECKX”
“RECHECKX” – Recheck Feature
This function is used to allow an additional 45 minute period to bring the cabinet temperature down to 41
degrees F (7 degrees C). When this feature is enabled it will operate as follows:
After a “HtIn” error has been issued (i.e. the cabinet temperature has not dropped below 45 degrees F in
30 minutes). The controller will perform 3 rechecks of the temperature in the next 45 minute period.
Rechecks will occur in 15 minute intervals. During this period the controller will not allow vending to occur
on health guarded selections.
1. If the cabinet temperature reaches 41 degrees F (5 degrees C) or less during this time the “HtIn” error will be
cleared. The controller will allow health guarded product to be delivered.
2. If after the 3rd recheck period the temperature is greater than 41 degrees F (5 degrees C). The controller will
clear the “HtIn” error, set the “RCHE” error and vending health guarded products will continue to be disabled.
3. If during the recheck period, any temperature reading that is greater than the previous reading (a trend
leading in the upwards direction) will result in clearing the “HtIn” error, setting the “RCHE” error and vending
health protected products will continue to be disabled.
“RETURN” - RETURN TO SALES MODE
Press key number 4 will exit Service Mode and return to Sales Mode.
Page 28
PROGRAMMING
28
of 90
COCA-COLA PROGRAMMING METHOD
QUICK REFERENCE MENU PROMPTS
Select Button 1: Abort / Cancel (will return to previous menu prompt or to normal door open mode)
Select Button 2: Scroll Up (forward in menu)
Select Button 3: Scroll Down (backward in menu)
Select Button 4: Enter / Save / Clear (allows you to enter a specific prompt, save what you have programmed, or clear the
error prompts)
**ERROR - Error Readout Routine
** VENDMECH - Vend Mechanism Error
COLJAM# - Column Jam
**CONTROL - Control System Error
DOORSWIT - Door Switch
RAM ERR - Board Check Sum
AC LOW - Voltage Low
SCALEER - Scale Factor
BILLCOMM - Validator Communication
BILL FULL - Stacker Full
BILL MOT - Defective Motor
BILL JAM - Bill Jam
BILL ROM - Check Sum
BILL OPEN - Open Stacker
BILL SENS - Validator Sensor
**CARD RDR - Card Reader Error
CARDCOMM - No Reader Communication
CARD# - Failed Reader
**ONLINE - Online Module Error
ONLINE - No Communication
ONL COMM - Network Not Responding
ONL INTL - Internal Online Problem
**RVEND - Remote Vend Mechanism Error
RV COMM# - No Communication
RVEND# # - Indicates Error Code
**SEL/DISP - Selection / Display Device Error
S/D COMM - No Communication
**REFRIG - Refrigeration Error
TEMPSENS - Temp Sensor Bad
TOO COLD - 30 Below Lower Limit
TOO HOT - 30 Above Lower Limit
** Prompts listed with asterisks are the only programs accessible coming from the factory. If other programs are desired,
they need to be turned on in the machine configuration code programs. Note: To enter “AUTO”, at the “PASS” prompt,
enter the correct password to enter Auto Test.
CONFIG: Machine Configuration
CON 1 Single Price / Multi Price
CON 2 Optional Features
CON 3 POS Message
CON 4 Auto View SALES and CASH
CON 5 Door Switch Reset
CON 6 Reserved
CON 7 Save Credit
CON 8 Force Vend
CON 9 Multi Vend
CON 10 Bill Escrow
**COINPAYO - Coin Payout Mode
**TUBEFILL - Tube Fill Mode
**TESTMODE - Test Routine
The most important facets of proper care and
maintenance of your machine are the electrical
power supplied to it, leveling, and cleanliness of the
machine.
POWER
The machine must be connected to a dedicated 120
VAC, 15 Amp circuit (U.S. and Canada).
CAUTION:
REMOVE POWER TO THE AC DISTRIBUTION
BOX WHEN ANY ELECTRICAL COMPONENTS
ARE CONNECTED / DISCONNECTED FOR
TESTING OR REPLACEMENT.
CLEANING
DO NOT USE A WATER JET OR NOZZLE TO
CLEAN THE VENDER
GLASS DOOR
The display glass should be cleaned inside and
out with paper towels and glass or non-abrasive
all-purpose cleaner. The gasket around the
product door should be wiped down using warm
water, any mild general purpose, non-abrasive
cleaner and a soft towel. Never lubricate the
gasket and always check for cracking or
deformities which may cause leaks. Replace if
necessary.
TRAYS / TRAY INSERTS
The trays and tray inserts should be cleaned
periodically using warm water and a mild
general purpose, non-abrasive cleaner. Care
should be taken to ensure water does not enter
the solenoids. DO NOT USE SOLVENTS OR
ABRASIVE MATERIALS TO CLEAN ANY
PORTION OF THE TRAY.
SLIDE/PUSHER ASSEMBLY
The slide/pusher assembly should be cleaned
periodically using warm water and any mild
general-purpose non-abrasive cleaner. After
drying, the slide assembly needs to have a coat
of Armorall applied. Care should be taken to
ensure liquid does not enter solenoids. DO NOT
USE SOLVENTS OR ABRASIVE MATERIALS
TO CLEAN ANY PORTION OF THE TRAY.
CABINET
Wash the cabinet with a good detergent or soap
mixed in warm water. Wax the vender often with
a good grade of automobile wax. Any corrosion
inside the vender should be removed with fine
steel wool and the area should be painted with
white paint.
Repair any scratches on painted surfaces to
prevent corrosion.
DRAIN PAN
Check the drain pan periodically for dirt, debris,
and proper alignment. Clean as needed.
Ensure nothing obstructs the drain tube and
drain hose.
WARNING
THE COMPRESSOR ELECTRICAL CIRCUIT IS
ALWAYS LIVE WHEN THE PLUG IS CONNECTED
TO AN ELECTRICAL OUTLET.
REFRIGERATION CONDENSER
Clean the condenser periodically of dirt or lint
build-up. Remove the build up with a brush or
vacuum, or blow the dirt out of the condenser
with compressed air and approved safety
nozzle. Ensure nothing obstructs air intake at
the bottom of the main door. Ensure nothing
obstructs air exhaust at the rear of the cabinet.
COIN ACCEPTOR
Follow the Coin Acceptor Manufacturer’s
instructions.
LUBRICATING THE VENDER
The vender refrigeration system does not
require any field lubrication. The hermetic
refrigeration system and fan motors are
manufactured with lifetime lubrication.
EPROM REPLACEMENT
Software changes / upgrades are accomplished by
changing the EPROM on the Control Board.
To change EPROM:
Remove power to the AC Distribution Box.
Remove existing EPROM.
Replace the EPROM. (The EPROM’s legs bend
easily. Remove and replace very carefully.)
Note the alignment notch at one end of the EPROM
and on the control board. The notches must be
matched or problems will occur. Appy power to the
AC distribution box. Display will scroll
“*/SOFTWARE/REV###.##/ICE COLD COCACOLA/##.##”. (SEE PAGE 81 FOR EPROM
LOCATIONS)
Page 30
MAJOR COMPONENT DESCRIPTION
30
of 90
MAJOR COMPONENT DESCRIPTION
AC DISTRIBUTION BOX
110 VAC
15 Amp Outlet (110 VAC) Provides power to
refrigeration unit.
Transformer (T1) Provides 24 Volt
and 12 Volt (center
tap) power to the
Controller Board.
Fuse (Top) 10 Amp, 32 Volt,
SloBlo; protects 24
Volt input to
Controller Board
from secondary of
T1.
Fuse (Bottom) 2 Amp, SloBlo;
protects 12 Volt
input to Controller
Board from
secondary, center
tap of T1.
Varistor Across incoming
AC power to
remove large power
spikes.
Choke (Domestic) Foster
A-16015-01
5mH 6A.
Choke (Export) Foster
A-160405
5mH 6A (220Volts)
REFRIGERATION UNIT
110 VAC
Compressor Aspera, 1/2 HP, 115 VAC,
60 Hz, 1 Phase
T6213Z
Unit uses 13 oz. of 134A
refrigerant
1A-1 800,102,29x.x1 800,102,40x.x1 Glass Door, 2 Pane (001-8250 and higher)
1A-2 800,101,87x.x1 NA Glass Door, 2 Pane (prior to 001-8250)
1B-1 800,102,36x.x1 800,102,38x.x1 Glass Door, Special 3 Pane (001–8250 and higher)
1B-2 800,102,02x.x1 NA Glass Door, Special 3 Pane (prior to 001–8250)
1C–1 626,055,30x.x3 800,102,33X.X1 Glass Door, Special Film 2 Pane Special (001–8250 and higher)
1C–2 800,102,12x.x1 NA Glass Door, Special Film 2 Pane Special (prior to 001–8250)
2 801,814,58x.x1 TBD Gasket, Glass Door
3A 801,306,49x.x1 SAME Top Hinge, Glass Door – Horizontal Mounting (001-8250 and
higher)
3B 801,306,48x.x1 NA Top Hinge, Glass Door - Horizontal Mounting (001-8152 to 001-
8250)
3C 801,305,70x.x1 NA Top Hinge, Glass Door (prior to 001-8152)
3D 800,303,56x.x1 SAME Top Hinge Screws ¼ - 20 (001-8152 and higher)
3E 800,303,41x.x1 NA Top Pivot Pin, Glass Door (prior to 001-8152)
3F 801,814,52x.x1 SAME Plastic Shoulder Bushing (Pike Glass Door)
4A 801,305,65x.x1 SAME Leg, Cabinet Base
4B-1 900,502,49x.x1 SAME
4B-2 800,503,38x.x1 SAME Leveling Leg Japan (not shown)
4C 805,410,96x.x1 SAME Skid Board (not shown)
5 W334 SAME Top Hinge, Service Door
6A 432,052,50x.x4 SAME Nut Retainer Housing Assembly
6B 432,050,73x.x3 SAME Nut Retainer Housing
6C 801,303,85x.x1 SAME Cage Nut
6D 900,801,06x.x1 SAME Square Nut, ½-13
6E 900,301,97x.x1 SAME Screw, Phil Pan #8-32x1/4
6F 900,302,01x.x1 SAME Screw, Hex ¼-20x5/8
7 626,030,19x.x3 SAME Storage Shelf Panel
8 804,400,51x.x1 SAME Ballast Assembly (SP-3)
9A 801,401,88x.x1 SAME Loading Platform (not shown)
9B 626,050,21x.x3 SAME Support Bracket, Loading Rack
9C 626,050,37x.x3 SAME Latch, Loading Rack (not shown)
10A 626,020,26x.x3 636,020,07x.x3 Bottom Skirt
10B 800,303,38x.x1 SAME Screw, Truss AB #8 - 18 x 1/2
11 801,813,13x.x1 SAME Condenser Intake Guard
12 800,303,37x.x1 SAME Screw, Phil Pan ¼-20x3/4L (prior to 001-8152)
13 900,800,67x.x1 SAME Keps Nut ¼-20
14 627,020,60x.x4 SAME Lag Bracket Kit (see Tech Bulletin 344)
15A 626,060,00x.x3 636,060,20x.x3
15B 626,060,30x.x3 TBD
16A 626,020,39x.x4 SAME Harvest Unit Installation Hardware Kit
16B 626,030,28x.x3 SAME Harvest Bracket
17 W766 SAME Carriage Bolt, ¼-20
18 626,020,42x.x3 SAME Right Security Angle
19A 800,503,33x.x1 SAME Bottom Service Door Hinge (001-8191 and higher)
19B 800,801,28x.x1 SAME Nut, Jam (001-8191 and higher)
19C 800,902,68x.x1 SAME Sleeve, Anti-Vandal (001-8191 and higher)
20A 626,052,70x.x4 SAME Kit, Vandal Plate, Vac Form (Service Part) (prior to 001-8152)
20B 805,701,91x.x1 SAME Vandal Plate Injection Molded (001-8152 and higher)
21 626,040,08x.x3 SAME Ingress Guard
22 804,100,77x.x1 SAME Power Interrupt Switch - Cabinet
TBD – To Be Determined Part numbers subject to change with out notice.
1A
1B 626,060,30x.x3 TBD Cabinet Assembly Export
1C 637,050,50x.x3 TBD Cabinet Assembly Export Japan
2A 626,070,25x.x3 SAME Tray Support, Left Side (not shown) – Domestic
2B 626,070,62x.x3 SAME Tray Support, Left Side – Export
3A 626,070,08x.x3 NA Tray Support, Right Side – Domestic (prior to 001-8152)
3B 626,070,63x.x3 NA Tray Support, Right Side – Export (prior to 001-8152)
3C 626,070,67x.x3 SAME Tray Support, Right Side – Domestic (001-8152 and higher)
3D 626,070,71x.x3 SAME Tray Support, Right Side – Export (001-8152 and higher)
4A 626,070,19x.x3 SAME Tray Support, Rear – Domestic
4B 626,070,64x.x3 SAME Tray Support, Rear – Export
5A 626,020,05x.x3 636,020,05x.x3 Security Angle, Top
5B 626,020,12x.x3 SAME Security Angle, Left
5C 626,020,42x.x3 SAME Security Angle, Right
6 626,070,51x.x3 SAME Door Switch Bracket
7 804,100,77x.x1 SAME Door Switch
8 801,812,41x.x1 SAME *Discharge Door Frame Assy (Does not include Discharge
8A 801,812,90x.x1 SAME Discharge Door
8B - 1 801,817,51x.x1 SAME Discharge Frame – refrigerated side (001-8152 and higher)
8B - 2 801,812,91x.x1 NA Discharge Frame – refrigerated side (prior to 001-8152)
8C 801,812,92x.x1 SAME Discharge Frame Back
8D 801,401,92x.x1 SAME Discharge Door Rod
8E 901,701,15x.x1 SAME Discharge Door Spring
8F 801,814,29x.x1 NA Rivet, Plastic Snap 1/8” (prior to 001-8152)
8G 801,814,30x.x1 NA Cap, Plastic Snap 1/8” (prior to 001-8152)
9 804,915,76x.x1 SAME KO Machine Options Harness
10 801,305,71x.x1 SAME KO Mounting Plate
11 804,915,64x.x1 SAME Discharge Door Switch Harness
12 626,020,28x.x3 SAME Service Door Strike Plate
13 801,306,02x.x1 SAME Sensor Guard Plate
14 800,303,21x.x1 SAME Screw, 8-18x1/2
15 801,814,48x.x1 SAME Right Side Tray Support Spacer
16 801,306,14x.x1 NA Conveyor Guide, Right Side (001-8152 and higher)
17 626,050,33x.x3 636,050,01x.x3 Conveyor Product Deflector Ramp
18 801,306,14x.x1 SAME Right Side Conveyor Guide (001-8152 and higher)
*NOTE: 8063 production run needs a special discharge door frame assembly or the opening will need
modification.
Part numbers subject to change with out notice.
636,060,20x.x3 Cabinet Assembly Domestic
Frame Back)
Page 65
PARTS
65
of 90
SERVICE DOOR FRONT
Page 66
PARTS
66
of 90
DN5000 & DN3000 SERVICE DOOR (FRONT)
CGF (Coke
Glass Front)
ITEM PART NUMBER PART NUMBER PART DESCRIPTION
1A 626,054,10x.x3 626,054,30x.x3 Service Door Assembly Domestic (IR)
1B 626,054,40x.x3 626,055,70x.x3 Service Door Assembly Export (IR)
1C 637,051,40x.x3 TBD Service Door Assembly Japan (IR)
2 626,050,10x.x3 626,053,10x.x3 Door Frame Assembly
3A 805,025,32x.x1 SAME Advertise Window
6 801,810,69x.x1 SAME POS Lens, Coin Insert Panel
7A 626,050,36x.x3 SAME Backup Plate Flat Keypad, Coin Insert Panel
7B 624,050,48x.x3 SAME Backup Plate, Coin Insert Panel
8A 803,863,03x.x1 SAME Keypad Overlay – Flat Keypad
8B W453-2 SAME Keypad, Button Array – Rubber
8C 626,031,80x.x4 SAME Keypad Guard Kit (use with Button Array Keypad –Rubber)
9 804,918,26x.x1 SAME Membrane, Button Array
10A 626,050,03x.x3 SAME Membrane, Plate Back
10B 626,050,36x.x3 SAME Keypad Plate Flat (use with keypad overlay)
10C 626,010,60x.x4 SAME Flat Keypad Kit
11 805,701,24x.x1 SAME T-Handle Shim
12A 801,519,13x.x1 SAME T-Handle Assembly
12B 801,518,14x.x1 SAME T-Handle
12C 801,518,18x.x1 SAME T-Handle Flange
12D 801,519,14x.x1 SAME T-Handle Stud
12E 801,507,34x.x1 SAME External Retaining Ring
12F 901,503,06x.x1 SAME Flat Washer
12G 901,503,09x.x1 SAME Cross Pin
12H 901,503,05x.x1 SAME Spring
12I 901,508,18x.x1 SAME Spring
12J 626,050,32x.x3 SAME T-Handle Bracket
13 626,051,20x.x3 SAME Bottom Panel Service Door
14 803,858,37x.x1 803,866,41x.x1 Port Panel Decal
15 801,812,38x.x1 801,815,75x.x1 Port Bezel
17 626,050,01x.x3 SAME Coin Mech Panel
18 902,001,02x.x1 SAME Validator Gasket
19A 626,050,57x.x3 626,070,77x.x3 Trim, Top
19B Top Trim Locking Bar (no longer used)
20 626,070,74x.x3 626,070,75x.x3 Horizontal Trim
21 626,070,78x.x3 626,070,79x.x3 Vertical Trim
22A 803,863,46x.x1 803,868,20x.x1 Transaction Panel Label – English Domestic
22B 803,863,47x.x1 TBD Transaction Panel Label – French
22C 803,863,43x.x1 TBD Transaction Panel Label – English Export
22D 803,863,44x.x1 TBD Transaction Panel Label – French Canadian
22E 803,863,42x.x1 TBD Transaction Panel Label - Spanish
23 800,801,15x.x1 SAME Wiring Nut 8-32 (remote access panel)
24 804,916,26x.x1 SAME Flat Cable Mount (keypad harness)
25 803,862,78x.x1 SAME Validator Filler Label (not shown)
26 626,054,70x.x4 626,054,80x.x4 Kit, T-Handle Lock Cover
9 901,701,07x.x1 Coin Return Spring
10 801,903,76x.x1 Red Display Filter
11 901,001,46x.x1 Stand Off, .192x312x312
12A 804,919,93x.x1 Display Domestic - IR (203-8211 and higher)
12B 804,914,86x.x1 Display Assembly (prior to 203-8211)
12C 804,920,05x.x1 Display Eprom (804,919,93x.x1 display board, 203-8211 and higher)
12D 804,914,97x.x1 Display Eprom (804,914,86x.x1 display board, prior to 203-8211)
13 801,806,58x.x1 Coin Hopper and Chute
14 801,806,59x.x1 Coin Chute Front
15 801,810,14x.x1 Change Cup
16 626,050,08x.x3 Cash Box Shelf
17 432,051,80x.x3 W/A Cash Box
18A 801,815,30x.x1 Injection Molded Discharge Port Assembly
18B 801,814,66x.x1 Discharge Port
19 626,050,23x.x3 Harvest Mounting Bracket
20A 624,050,93x.x3 Bill Validator Filler Plate
20B 637,051,00x.x3 Japanese Yen Validator Bracket Assembly
21 803,600,92x.x1 Discharge Port Pad
22 801,813,07x.x1 Backer Bezel Panel
23 626,050,25x.x3 Port Mounting Bracket
24 626,020,35x.x3 Vandal Plate, Port – Vacum Formed
25A 626,052,70x.x4 Vandal Plate, Vacuum Formed Port Kit (Prior to 318-8166)
25B 805,701,91x.x1 Vandal Plate, Injection Molded Port (318-8166 and higher)
25C 626,053,20x.x4 Injection Molded Port Assembly Kit
25D 805,702,07x.x1 Vandal Plate, Injection Molded – Extended (318-8166 and higher)
1 626,071,30x.x3 636,070,20x.x3 Tray Assembly
2 626,070,09x.x3 635,070,01x.x3 Tray Chassis
3 801,903,83x.x1 SAME Gate Assembly with Kicker
4 804,300,16x.x1 SAME Solenoid
5 801,519,29x.x1 SAME Plunger and Spring Assembly
6A 801,903,82x.x1 SAME Slide with Product Pusher Assembly
6B 801,812,79x.x1 SAME Product Pusher Slide, Bottom
6C 901,701,08x.x1 SAME Product Pusher Spring (not shown)
7 801,401,98x.x1 801,402,21x.x1 Wire Tray, Rigid
8 W485-1 SAME Label, Position Selection Sheet
9 622,070,04x.x3 SAME Side Shelf Stiffener (not shown)
10 W789 SAME Cotter Pin (not shown)
11 W218 SAME Solenoid Retainer Washer (not shown)
12 W398 SAME Retainer Washer (not shown)
13A D334 SAME
13B 800,101,94x.x1 SAME
14 901,901,00x.x1 SAME
15 See List SAME Spacers
15A 801,812,69x.x1 SAME Spacer – A
15B 801,812,81x.x1 SAME Spacer – B
17A 801,812,83x.x1 SAME Can Rotator, Gray – Snap in Rotator
17B 801,812,99x.x1 SAME Product Rotator, White - Snap In Rotator
18A 801,903,84x.x1 SAME Stabilizer, Columns 1 & 9 or 1 & 6
18B 801,903,85x.x1 SAME Stabilizer, Columns 2 through 8 or 2 through 5
19 900,301,56x.x1 SAME Screw, 8-32x3/8 Phil Pan (for old style rotator)
20 800,101,94x.x1 SAME ¼” Drive Socket 1/8” 6 point
1A - 1 626,031,90x.x3 *AC Distribution Box Assembly T8 Electronic Domestic (049-8234 and higher)
1A - 2 626,030,40x.x3 AC Distribution Box Assembly Domestic
1A - 3 637,050,10x.x3 AC Distribution Box Assembly Japan
1B 626,030,70x.x3 AC Distribution Box Assembly Export
1C 626,031,30x.x3 AC Distribution Box Assembly Korea
10A 804,920,56x.x1 *AC Distribution Harness Domestic T8 Electronic (049-8234 and higher)
10B 804,913,71x.x1 *AC Power In Harness, not shown - goes to item 6 (prior to 049-8234)
11A 804,920,58x.x.1 *Power Distribution Harness Domestic T8 Electronic (049-8234 and higher)
11B 804,915,87x.x1 *Power Distribution Harness, not shown – goes to item 5 (prior to 049-8234)
12 804,915,15x.x1 Rocker Switch Panel Mount
13 804,200,26x.x1 Relay
14 803,860,85x.x1 Main Power Label
15 804,920,41x.x1 Choke
16 903,825,86x.x1 Label, Warning High Voltage
17 804,913,77x.x1 Cord, Main Power
18 804,800,87x.x1 Circuit Breaker 30A Japan
19 804,916,93x.x1 Switch 3 Position Rotary (Exports only)
*Includes 115 to 162 – 8233
Part numbers subject to change with out notice.
Page 73
PARTS
73
of 90
ELEVATOR
8
7
9
Page 74
PARTS
74
of 90
DN5000 & DN3000 ELEVATOR
ITEM PART NUMBER PART DESCRIPTION
1 805,202,37x.x1 Elevator with Motor Assembly
2A 804,100,99x.x1 Lower Motor Limit Switch
2B 801,306,03x.x1 Bracket, Home Position Aluminum
2 804,915,81x.x1 SAME Conveyor Assembly Wiring (not shown)
3 804,915,75x.x1 SAME Power Cord (not shown)
4 801,813,08x.x1 SAME Product Slide, Conveyor
5 801,812,65x.x1 SAME Tip Arm Base
6 801,401,94x.x1 SAME Tip Arm
7 626,050,33x.x3 SAME Product Deflector Ramp
8 626,070,31x.x3 SAME Coke Conveyor Deflector
11 626,070,21x.x3 636,070,10x.x3 Coke Conveyor Front Plate
626,070,72x.x3 636,070,90x.x3 Dasani Conveyor front Plate
12 804,501,16x.x1 SAME Conveyor Motor
13 800,503,09x.x1 SAME Conveyor Spacer
14 801,812,42x.x1 801,817,56X.X1 Conveyor Bed
15 801,812,85x.x1 SAME Conveyor Drive Pulley Assembly
16 801,812,84x.x1 SAME Conveyor Idler Pulley Assembly
17 804,915,81x.x1 SAME KO Conveyor Harness
18 801,812,35x.x1 801,817,57x.x1
19A 800,902,62x.x1 SAME Shoulder Phil Head with Locking Patch (001-8100 and higher)
19B 800,303,36x.x1 SAME Screw, Phil Pan 10-32X3/8 – conveyor to pillow block (prior to
19C 800,303,42x.x1 SAME Upgrade Kit Screws (prior to 001-8100)
19D 900,700,02x.x1 SAME Washer (used with 800,303,42x.x1)
19E 626,010,00x.x4 SAME Conveyor Mounting Screw (prior to 001-8100)
20 800,303,42x.x1 SAME Screw, Phil pan w/ Nylock #8-32x3/8
21 801,813,44x.x1 SAME Coke Conveyor Motor Cover
801,815,59x.x1 SAME Dasani Conveyor Motor Cover
22 801,814,48x.x1 SAME Tray Support Spacer
23 803,859,73x.x1 803,869,39x.x1 Coke Conveyor Decal
803,866,42x.x1 TBD Dasani Conveyor Decal
Note: Conveyor Motor gets 24VDC
Elevator Motor gets 24VDC
Elevator encoder gets 5VDC
Part numbers subject to change with out notice.
A6A 804,700,79x.x1 NA *Lamp, 30 inch F021/865/XP/ECO - T8 (049-8234 and higher)
NA 804,700,82X.X1 Lamp, 18 inch F013/865/XP/ECO - T8
A6B 804,700,69x.x1 NA
NA 804,700,89x.x1
A7 904,800,41x.x1 NA Starter FS-25
A8 804,101,07x.x1 SAME Switch, PI
A9 626,070,61x.x1 NA Lamp Channel Starter Bracket
A10A 801,904,35x.x1 801,904,37x.x1 *Lamp Cover, Instant Start T8 (049-8234 and higher)
A10B 801,904,06x.x1 NA *Lamp Cover (prior to 049-8234)
A11 801,904,06x.x1 SAME End Caps, Lamp Sleeve
B1A 626,055,20x.x3 SAME *Sub Assembly Service Door Lamp T8 Domestic (049-8234
B1B 626,050,80x.x3 SAME *Sub Assembly Service Door Lamp, Domestic (prior to 049B1C 626,031,10x.x3 SAME
B1D 637,051,50x.x3 SAME Sub Assembly Service Door Lamp T8 Japan
B2A 804,700,81x.x1 SAME *Lamp, U shaped FB016/865/XP, T8 (049-8234 and higher)
B2B 804,700,35x.x1 SAME *Lamp, F13T8CW (prior to 049-8234)
B3A 626,050,51x.x3 SAME *Service Door Lamp Bracket T8 (049-8234 and higher)
B3A 804,920,54x.x1 SAME *Door Lighting Harness T8 Electronic, not shown (049-8234
B3B 626,050,22x.x3 SAME *Service Door Lamp Bracket (prior to 049-8234)
B4B 804,915,65x.x1 SAME *KO Door Lighting Harness, not shown (prior to 049-8234)
B5 805,507,27x.x1 SAME Converter, ADU018 CLX MDB-UCCS Box Japan
C1 803,870,05x.x1 SAME *Label, T8 Lamp Replacement (049-8234 and higher)
* Includes 115 to 162 - 8233
Part numbers subject to change with out notice.
23 626,040,04x.x3 Evaporator Fan Shroud
24A 804,501,09x.x1 Evaporator Fan Motor Assembly, Domestic/Japan
24B 804,501,11x.x1 Evaporator Fan 8” 9W, 220-230 / 50, Export
25A 801,812,63x.x1 Side Gasket, Drain Pan
25B 801,812,64x.x1 Front Gasket, Drain Pan
1A 626,056,30x.x4 TBD KO Board Universal Assembly (T8) 077-8272 & up
1B 626,030,21x.x3 SAME KO Board Mounting Plate
1C 626,050,48x.x3 SAME KO Board Cover 077-8272 & up
627,050,31x.x3 SAME KO Board Cover prior to 077-8272
2C - 1 626,030,36x.x3 SAME Machine Board Cover, ESD (099-8212 and higher)
2C - 2 801,904,16x.x1 SAME Machine Board Cover, Plastic (prior to 099-8212)
2D - 1 626,030,37x.x3 SAME Machine Controller Mounting Plate (099-8212 and higher)
2D - 2 622,050,32x.x3 SAME Machine Controller Mounting Plate (prior to 099-8212)
2E 801,903,87x.x1 SAME Control Board Stand Offs, Richo
3A 804,919,93x.x1 SAME Display Assembly, ASD (203-8211 and higher)
3B 804,914,86x.x1 SAME Display Assembly (prior to 203-8211)
4 804,100,77x.x1 SAME Door Switch
5 804,100,99x.x1 SAME Lower Motor Limit Switch
6 804,101,04x.x1 SAME KO Limit Switch Magnet
7 804,101,05x.x1 SAME Unencapsulated Magnet
8 804,915,84x.x1 SAME 24 VDC Snap In Mount Counter
9A 626,020,44x.x4 SAME Override Switch Kit
9B 801,510,10x.x1 SAME Override Switch
10 804,914,99x.x1 SAME EPROM, KO Board
11 804,914,16x.x1 SAME EPROM, Machine Board
12A 804,920,05x.x1 SAME EPROM, Display (203-8211 and higher)
12B 804,914,97x.x1 SAME EPROM, Display (prior to 203-8211)
13 626,050,52x.x4 SAME MDB Electronic Interface Kit Japan
14A 637,050,60x.x3 SAME Stabilizer Enclosure Box Assembly Japan
14B 804,400,76x.x4 SAME Voltage Stabilizer Kit (105V) Japan
14C 804,400,73x.x1 SAME Voltage Stabilizer Transformer (105V) Japan
14D 637,050,70x.x3 SAME Stabilizer Enclosure Door Assembly Japan
Part numbers subject to change with out notice.
PART NUMBER
REMANUFACTURED
PART DESCRIPTION
Page 83
PARTS
83
of 90
HARNESSES
ITEM PART
NUMBER
1 804,913,74x.x1 Tray Harness 8 Column Solenoids to J3, J4, J5, J6, J7 on Machine
804,920,34x.x1 Tray Harness 6 Column Solenoids to J3, J4, J5, J6, J7 on Machine
(prior to 049-8234)
3 804,915,81x.x1 Conveyor Harness Elevator E-Chain harness
4 804,915,69x.x1 Relay Control Harness Lights, Fan, Compressor to P5 on Machine
5 804,919,66x.x1 Encapsulated Temperature Sensor
(factory installed beginning 001-8152)
6 804,915,64x.x1 Discharge Door Switch Harness Discharge door to J10 on Machine board
7 804,915,76x.x1 Machine Options Harness Counter / Override / Door Switch to P7 on KO
8 804,915,62x.x1 Board to Board Communication
Harness
9A 804,920,63x.x1 *Main Power Harness T8 Electronic
(049-8234 and higher)
9B 804,915,59x.x1 *Main Power Harness
(prior to 049-8234)
9C - 1 804,913,77x.x1 Main Power Cord
9C - 2 804,920,70x.x1 Power Adapter Japan
10 804,915,72x.x1 Override Switch Harness Service Option to KO machine option harness
11A 804,920,53x.x1 *Cabinet Lighting Harness T8
Electronic (049-8234)
11B 804,915,67x.x1 *Cabinet Lighting Harness
(prior to 049-8234)
12 804,915,89x.x1 DC Door Bundle Assy. Display, MDB peripheral, DEX to P9, P3, and
13 804,915,91x.x1 DC Main Bundle Assy. Conveyor, Elevator, Kill / Limit Switch, to J2, J8,
14A 804,916,24x.x1 Secondary KO DEX Harness KO board to port
14B 800,801,29x.x1 Nut, DEX harness Nut to secure DEX harness in port.
15A 626,020,44x.x4 Override Switch Kit
15B 801,510,10x.x1 Override Switch / Lockout
15C 804,915,72x.x1 CGFV Override Harness
15D 901,512,11x.x1 Key
16 804,914,74x.x1 Internal / External KO DEX Harness
* Include 115 to 162 - 8233
Part numbers subject to change with out notice.
PART DESCRIPTION FROM / TO
Board
Board
From service door light to DC door bundle
assembly
From service door light to DC door bundle
assembly
board
From Machine Board to Evaporator
Board
J1 on Machine Board to J14 on KO board
9 pin plug on AC box to lights, temperature
control, and P5 on machine board
9 pin plug on AC box to lights, temperature
control, and P5 on machine board
Cabinet light to DC door bundle assy.
P1 on KO board
and J9 on Machine Board
Page 84
PARTS
84
of 90
LABELS / DECALS / MISC.
CGF (Coke
Glass Front)
ITEM PART NUMBER PART NUMBER
1 803,859,74x.x1 Bottom Glass Door Decal
2 803,859,72x.x1 803,866,39x.x1 Top Glass Decal
3 803,859,71x.x1 803,866,43x.x1 Cabinet, Side Decal
4 803,857,26x.x1 Selection Label
5 803,856,15x.x1 Asset / Property Tag Coca-Cola Company
6 803,868,29x.x1 Warning: DO NOT TILT Label, Tri Lingual
7 803,859,73x.x1 803,866,42x.x1 Conveyor Decal
8 803,853,21x.x1 AC Distribution Box Fuse Label (2 Amp – 10 Amp)
9 803,853,22x.x1 AC Distribution Box Power Disconnect Label
10 803,860,61x.x1 Quick Reference Program Label
11 803,853,25x.x1 Validator / Changer Label
12 803,858,37x.x1 803,866,41x.x1 Port Panel Decal
13 803,870,05x.x1 T8 Lamp Replacement Label (049-8234 and higher)
14 803,857,26x.x1 Selection Label Sheet (white with black letters – column #’s)
15 803,903,03x.x1 Manual, Technical
16 803,902,99x.x1 Quick Reference Laminated Card
17 803,903,02x.x1 Price Setting Programming Reference Guide
18 W485-2 thru 13 Price Sheets
19 803,903,04x.x1 Literature Package (includes items #5, 10, 15, 16, 17, and 18)
20 803,861,31x.x1 Package Setup Label
A9 900,301,56x.x1
A10 900,201,31x.x1
A11 900,301,97x.x1
A12 900,301,85x.x1
A13 900,300,16x.x1
A14 900,301,81x.x1
A15 900,201,14x.x1
A16 900,301.65x.x1
A17 900,302,01x.x1
A18 900,301,69x.x1
A19 900,901,51x.x1
A20 900,201,22x.x1
A21 900,301,98x.x1
A22 900,301,84x.x1
A23 900,500,26x.x1
A24 900,201,13x.x1 Screw, Hex Head
A25 900,301,73x.x1
A26 800,303,15x.x1
A27 800,303,18x.x1 Screw, Truss Type 23 #8-32x1/2
A28 900,301,94x.x1
A29 900,201,44x.x1
A30 900,301,99x.x1 Screw, Plastic 8-hi/low x 1-1/4
A31 900,301,55x.x1 Screw, Phil Pan Swage Form #8-32x1/2 Screw
A32 900,303,08x.x1
A34 800,303,22x.x1 Screw, Phil Pan #6-20x3/8
A35 900,302,02x.x1 Screw, Self Tapping #8-18x3/4
A36 900,201,86x.x1
A37 900,301,91x.x1
A38 900,201,87x.x1 Screw, Phil Truss #10-32x3/8
A39 W796
A40 W948
A41 800,303,21x.x1 Screw, Phil Pan Sems #8-18x1/2
A42 800,303,34x.x1 Screw, Phil Pan 8-Hilox 1/2
A43 D334 Screw, Hex Washer 4-24x3/4
A44 W851 Screw, Pan Head
A45 900,301,70x.x1 Screw, Phil Pan #6-32x3/8
A46 800,902,62x.x1 Screw, Shoulder
B1 900,800,65x.x1 Hex Nut, #10-32
B2 900,800,67x.x1 Hex Nut, 1/4-20
B3 900,800,50x.x1 Hex Nut, #8-32
B4 900,800,69x.x1 Hex Nut, Top Door Hinge, 3/8-16
B5 900,800,85x.x1 Speed Nut
Part numbers subject to change with out notice.
Screw, Phil Pan Swage Form #6-32x3/8″
Screw, Phil Pan Swage Form w/ Washer #8-32x1/2″
Screw, Phil Pan Swage Form #10-32x5/16″
Screw, Phil Pan without Washer, #8-18x1/2″
Screw, Phil Pan Swage Form #8-32x1/4″
Screw, Vend Motor, #4-24x3/4″ Single Switch
Screw, Vend Motor, #4-24x1-16 ″ Double Switch
Screw, Vend Motor #4-24x1-1/2″ Triple Switch
Screw, Phil Pan Cutting #8-32x3/8 ″
Screw, Machine, #6-32x1-1/4 ″
Screw, Phil Pan Sems #8-32x1/4″
Screw, Phil Pan Thread Form #8-32x5/8″
Screw, Phil Head Truss #6x3/8″
Screw, Phil Pan Form #10-32x1-1/4″
Screw, Machine Truss, #10-32x1/2″
Screw, Phil Pan Sems with Washer, #8-18x1/2″
Screw, Self Tapping, 1/4″-20x5/8″
Screw, Hex Head Swage Form #8-36x3/8″
Screw, Phil Pan Tapping #10-23x5/8″
Screw, Machine Phil Pan #8-32x3/4″
Screw, Phil Pan Shoulder #8-18x1/2″
Screw, Phil Pan #8-18x1/2″
Shoulder Screw, 1/2″ Long
Screw, Tap ½-20x1″ Type F
Screw, Phil Pan #8-18x3/4″
Screw, Phil Flat 23B #10-32x1/2″
Screw, Machine Brass #6-32x1/4″
Screw, Hex Washer Type 1 #8-32x3/8″
Screw, Phil Pan Head #6-32x1/4″
Screw, Hex Wash #8-18x1/2″
Screw, Taper Tite #8-18x3/8″
Screw, Hex Head #10-16x50″
Pop Rivet, Aluminum 1/4″
Drive Rivet, #38-108-06-13 1/4″
Pop Rivet, Black 1/8″
Pop Rivet, Steel (zinc plated) 1/8″
Pop Rivet, Aluminum 1/8″
Pop Rivet, Steel (zinc plated) 3/16″
Pop Rivet, Aluminum Black 1/8″
Pop Rivet, Aluminum White 1/8″
Page 90
PARTS
90
of 90
WASHERS , BOLTS, AND MISC. HARDWARE (continued)
ITEM PART NUMBER PART DESCRIPTION
H1 900,902,13x.x1 Christmas Tree Clip #354280307-00
H2 900,901,89x.x1 Tinnerman Clip, Fan Shroud (C5207-014-3B)