Maytag CWG3100AAS, 9112XUB Installation Guide

INSTALLER" LEAVE THESE INS TRUG TIONS WITH THE APPLIANCE
INSTALLATION MANUAL
Gas 24-inch Built-ln Ovens
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
THE MANUAL IS INTENDED TO ASSIST IN THE INITIALINSTALLATION AND ADJUSTMENTS OF THE RANGE
Clearance Dimensions
For complete information in regard to the installation of
wall ovens and clearances to combustible wall above the
Only qualified personnel should install or service this range.
Read "Safety Instructions" in the
Improper installation, adjustment,
alteration, service, maintenance or use of range can result in serious
injury or property damage.
cooking top see the installation drawings.
A WIRING DIAGRAM IS ENCLOSED IN THE ENVELOPE WITH THIS BOOKLET; ALSO THERE IS A DIAGRAM GLUED TO THE UNIT, BEHIND CONTROL
PANEL.
CAUTION: SOME CABINETS AND BUILDING
MATERIALS ARE NOT DESIGNED TO WITH- STAND THE HEAT PRODUCED BY THE
NORMAL SAFE OPERATION OF A LISTED APPLIANCE. DIS- COLOATION OR DAMAGE,
SUCH AS DELAMINATION, MAY OCCUR.
Your range may not be equipped with some of the features referred to in this
manual.
8101 P590-60
(o8-o5-o1)
Installation Drawings
PROVIDE SLOT
120 VOLT GROUNDED
ELECTRICAL OUTLET
IN THIS AREA
FRONT OF CABI
OVEN SUPPLIED WITH
112" NPT FEMALE INLET
ON REGULATOR.
62"
WITH A 3
PRONG CORD
I I
I I
I I
I
I
I I I I
11
MIN
4" RECOMMENDED AREA FOR ELECTRICAL
CONNECTION
45-318"
I!
IDE HOLE IN THIS GENERAL AREA FOR CONNECTING TO
112" DIAMETER PIPE
FITTING
46-5/16"
COMPLETE FLOC
IS RECOMMENDED
TO PREVENT
14" MIN.
HEIGHT
UNUSUAL DRAFTS.
URE OVEN TO CABINET THROUGH
HOLES PROVIDED IN TRIM. FOUR
SCREWS SHIPPED WITH UNIT.
FIGURE I
24" GAS WALL OVENS
UPPER OVEN LOWER OVEN OR BROILER OVEN FRAME SIZE CUTOUT DIMENSIONS
MODEL WIDTH HEIGHT DEPTH WIDTH HEIGHT DEPTH WIDTH HEIGHT WIDTH HEIGHT "A" DEPTH
DOUBL_
OVEN 18" 14" !9" 18" 12" 19" 23 7/8" 46 5/16" 22" 45 318" 24"
3VEN WIT}[
_I{on,ER 18" 14" 19" 18" 6.25" 19" 23 718" 39 114" 22" 38" 24"
-2-
"A" "B"
Installation
Check the oven model number plate to see if the oven is approved for installation in mobile homes and/or
recreational vehicles. If approved the following items are applicable. NOTE: Oven model number plate is located
under broiler bottom.
Mobile Homes
The installation of an oven designed for mobile home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24 HUD, (Part 280) or,
when such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A, or with local codes.
In Canada the range must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical Code Part 1 and Section Z240.4.1 - Installation
Requirements for Gas Burning Appliances in Mobile Homes (CSA Standard CAN/CSA - Z240MH).
Recreational Vehicles
The installation of an oven designed for recreational vehicles must conform with state or other codes or, in the absence of such codes, with the Standard for
Recreational Vehicles, ANSI A119.2-latest edition. In Canada the oven must be installed in accordance with CAN/CSA - Z240.6.2 - Electrical Requirements for R.V.'s
(CSA Standard CAN/CSA - Z240 RV Series) and Section Z240.4.2 - Installation Requirements for Propane
Appliances and Equipment in R.V.'s (CSA Standard
CAN/CSA - Z240 RV Series).
Locating The Unit
The installation diagram gives the minimum dimensions of the cabinet cut-out for the oven. The dimensions given
are for the oven bottom to be a minimum of 14" inches above the floor. The recess in which the oven is to be
installed should have a solid floor and be so constructed as to provide a complete enclosure around the recessed
portion of the oven to prevent drafts which may result in inconsistent and unsatisfactory burner and baking
performance, it should be perfectly level to provide a solid, level foundation for the oven unit. The openings in
the enclosure for gas and electric service should be sealed before the oven is installed.
For SAFETY CONSIDERATIONS fasten the oven to the cabinet with the four (4) screws (shipped with the unit)
through the holes in the trim behind the oven and broiler doors. The unit should be leveled properly before being
secured to the cabinet.
Electric Supply
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70.
In Canada the oven must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical
Code Part 1. ELECTRICAL SUPPLY CONNECTION:
The oven requires 120 volts, 60 cycle alternating current
from an outlet capable of supplying 15 amperes.
User may experience occasional circuit tripping if Ground Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
, WARNING
Electrical Grounding Instructions
This appliance is equipped with a (three-prong) grounding plug for your protection against shock
hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove
the grounding prong from this plug.
I WARNING
DISCONNECT ELECTRICAL SUPPLY
BEFORE SERVICING THE APPLIANCE.
-3-