Maytag CWG3100AAE, CWG3100AAB Installation Guide

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE
INSTALLATION MANUAL
Gas 24-inch Built-In Ovens
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE.
Clearance Dimensions
For complete information in regard to the installation of
wall ovens and clearances to combustible wall above the
Only qualified personnel should install or service this range.
Read "Safety Instructions" in the Use & Care book before using range.
cooking top see the installation drawings.
A WIRING DIAGRAM IS ENCLOSED IN THE
ENVELOPE WITH THIS BOOKLET; ALSO THERE IS A DIAGRAM GLUED TO THE UNIT, BEHIND CONTROL
PANEL.
Improper installation, adjustment,
alteration, service, maintenance or
use of range can result in serious injury or property damage.
CAUTION: SOME CABINETS AND BUILDING
MATERIALS ARE NOT DESIGNED TO WITH- STAND THE HEAT PRODUCED BY THE NORMAL SAFE OPERATION OF A LISTED
APPLIANCE. DIS- COLOATION OR DAMAGE,
SUCH AS DELAMINATION, MAY OCCUR.
8101 P531-60
(01-03-00)
Installation Drawings
FRONT OF CABIN
OVEN SUPPLIED WITH
I12" NPT FEMALE INLET
ON REGULATOR,
62 "
WITH A 3
PRONG CORD
PROVIDE SLOT
120 VOLT GROUNDED
ELECTRICAL OUTLET
IN THIS AREA
4" RECOMMENDED AREA FOR ELECTRICAL
CONNECTION
46-5 16"
2-1 1/16" _ 24"
22-5/8" _ MIN
COMPLETE FLO01
IS RECOMMENDED
UNUSUAL DRAFTS.
OVEN TO CABINET THROUGH
HOLES PROVIDED IN TRIM, FOUR
SCREWS SHIPPED WITH UNIT.
II
TO PREVENT
ii
ROVIDE HOLE IN
THIS GENERAL AREA
FOR CONNECTING TO
I/2" DIAMETER PIPE
FITTING
22-3/8"
14" MIN,
HEIGHT
FIGURE 1
24" GAS WALL OVENS
UPPER OVEN LOWER OVEN OR BROILER
WIDTH HEIGHT DEPTH WIDTH HEIGHT DEPTH
18" 14" 19" 18" 12" 19" 18" 14" 19" 18" 6,25" 19"
-2-
OVEN FRAME SIZE
WIDTH HEIGHT 23 7/8" 46 5/16"
23 7/8" 39 1/4"
CUTOUT DIMENSIONS
WIDTH HEIGHT "A" DEPTH
22" 45 3/8" 24" 22" 38" 24"
Installation
Check the oven model number plate to see if the oven is approved for installation in mobile homes and/or
recreational vehicles. If approved the following items are applicable. NOTE: Oven model number plate is located
under broiler bottom.
Mobile Homes
The installation of an oven designed for mobile home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24 HUD, (Part 280) or,
when such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A, or with local codes.
In Canada the range must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical Code Part 1 and Section Z240.4.1 - Installation
Requirements for Gas Burning Appliances in Mobile Homes (CSA Standard CAN/CSA - Z240MH).
Recreational Vehicles
The installation of an oven designed for recreational vehicles must conform with state or other codes or, in the absence of such codes, with the Standard for
Recreational Vehicles, ANSI A119.2-latest edition. In Canada the oven must be installed in accordance with CAN/CSA - Z240.6.2 - Electrical Requirements for R.V.'s
(CSA Standard CAN/CSA - Z240 RV Series) and Section Z240.4.2 - Installation Requirements for Propane
Appliances and Equipment in R.V.'s (CSA Standard
CAN/CSA - Z240 RV Series).
Locating The Unit
The installation diagram gives the minimum dimensions of the cabinet cut-out for the oven. The dimensions given
are for the oven bottom to be a minimum of 14" inches above the floor. The recess in which the oven is to be
installed should have a solid floor and be so constructed as to provide a complete enclosure around the recessed
portion of the oven to prevent drafts which may result in inconsistent and unsatisfactory burner and baking
performance, it should be perfectly level to provide a solid, level foundation for the oven unit. The openings in
the enclosure for gas and electric service should be sealed before the oven is installed.
For SAFETY CONSIDERATIONS fasten the oven to the cabinet with the four (4) screws (shipped with the unit)
through the holes in the trim behind the oven and broiler doors. The unit should be leveled properly before being
secured to the cabinet.
Electric Supply
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70.
In Canada the oven must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical
Code Part 1. ELECTRICAL SUPPLY CONNECTION:
The oven requires 120 volts, 60 cycle alternating current
from an outlet capable of supplying 15 amperes.
User may experience occasional circuit tripping if Ground Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
, WARNING
Electrical Grounding Instructions
This appliance is equipped with a (three-prong) grounding plug for your protection against shock
hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove
the grounding prong from this plug.
I WARNING
DISCONNECT ELECTRICAL SUPPLY
BEFORE SERVICING THE APPLIANCE.
-3-
Connecting The Oven
Gas Supply
Installation of this oven must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1-1atest edition. In Canada the oven must be installed in accordance with
the current CGA Standard CAN/CGA-B149 - Installation Codes for Gas Burning Appliances and Equipment and/or
local codes.
In The Commonwealth Of Massachusetts
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of
Massachusetts. A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance. A flexible gas connector, when used must not exceed a
length of three (3) feet / 36 inches.
b.
The house piping and/or oven connector used to connect the oven to the main gas supply must be
clean, free of metal shavings, rust, dirt and liquids (oil or water). Dirt, etc. in the supply lines can work its way
into the range manifold and in turn cause failure of the gas valves or controls and clog burners.
CAUTION: DO NOT LIFT OR MOVE THE WALL OVEN BY THE DOOR HANDLES.
c. Turn off all pilots and main gas valve of other gas
appliances.
d. Turn off main gas valve at meter. e. Before connecting the unit, apply pipe thread
compound approved for LPG to all threads.
f. Connect unit to gas supply. Use a backup wrench
when pulling on end of regulator.
GAS SUPPLY CONNECTION: A QUALIFIED SERVICEMAN OR GAS APPLIANCE
INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be
conducted by the installer according to the instructions given below in section h.
NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL GAS SERVICE REGULATOR. INLET
PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER
COLUMN (0.5 POUNDS PER SQUARE INCH (P.S.I.) LIQUIFtED PETROLEUM (LP.)/PROPANE GAS
SUPPLY LINE MUST HAVE ALP. GAS PRESSURE REGULATOR. INLET PRESSURES IN EXCESS OF 0.5
P.S.I. CAN DAMAGE THE APPLIANCE PRESSURE REGULATOR AND OTHER GAS COMPONENTS IN
THIS APPLIANCE AND CAN RESULT IN A GAS LEAK.
A GAS CUTOFF VALVE SHOULD BE PUT IN AN
a.
ACCESSIBLE LOCATION IN THE SUPPLY LINE AHEAD OF THE UNIT, FOR TURNING ON AND
TURNING OFF GAS SUPPLY. tf the unit is to be connected to house piping with flexible or semi-rigid
metal connectors for gas appliances, CONNECTOR
NUTS MUST NOT BE CONNECTED DIRECTLY TO PIPE THREADS. THE CONNECTOR MUST BE
INSTALLED WITH ADAPTORS PROVIDED, WITH
THE CONNECTOR.
CAUTION: MAKE SURE THE CONNECTION DOES
NOT SHIFT THE REGULATOR PIPE OUT OF POSITION.
Turn on main gas valve at meter, and relight pilots at
g.
other gas appliances.
h.
Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the supply
line shut-off valve and the range. Include gas fittings and joints in the range if connections were disturbed
during installation. Check for leaks! Bubbles appearing around fittings and connections will indicate a leak. If a
leak appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas shut
off valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when
cold.
BEFORE LIGHTING ANY BURNER, SEE THAT ALL PACKING MATERIALS HAVE BEEN REMOVED
FROM THE UNITS.
-4-
Unit Adjustments
Wall Oven Adjustment
ELECTRIC IGNITION - BAKE BURNER WITH ELECTRIC GLOW BAR
a. The bake burner is equipped with an electric control
system as well as an electric oven burner ignitor (figure 2). This control system requires NO
adjustment. To operate, turn thermostat knob to any temperature setting or to broil. Current will flow to the
ignitor. It will "glow" similar to a light bulb. (This glow may be reflected into the oven through the openings in
the oven bottom). When the ignitor has reached a temperature sufficient to ignite gas, the electrically
controlled oven valve will open and flame will appear at the oven burner. There is a time lapse from 30 to 45
seconds after the thermostat is turned ON before flame appears at the oven burner. When the oven has
reached the dial setting, the glowing ignitor will go OFF. The burner flame will go "out" in 20 to 30
seconds after the ignitor goes "OFF". To maintain any given oven temperature this cycle will continue as long as the dial is at the given temperature. Figure 3 is an
illustration of a typical range.
FIGURE 2
b. In case servicing should become necessary, a manual
gas valve to shut off the gas to the oven burner is supplied between the gas regulator and the oven
burner valve, tt is located at the front of the oven bottom or on right rear of gas regulator. See figure 3.
c. The oven CANNOT be used during periods of
power outage. In case of power failure, turn the thermostat to the OFF position.
GAS SUPPLY PIPING
(NOT SUPPLIED BY
MANUFACTURER)
MANIFOLD-
PRESSURE TAP
SER PLATE
PRESSURE
REGUALTOR
ICAL
DISCONNECT
NUAL OVEN VALVE-
(SHOULD SERVICE EVER BECOME NECESSARY)
WHEN THE INSTALLER HAS COMPLETED INSTALLATION OF APPLIANCE, LEAVE THE APPLIANCE MANUAL SHUT-OFF VALVE IN THE "ON" POSITION.
FIGURE 3
-5-
AIR SHUTTER - OVEN BURNER
a. The approximate length of the flame of oven burner is
a 1/2 inch distinct blue flame, figure 4.
lift or blow off the burner when cold. (See #2 on
figure 5.)
b. Oven burner flame can be checked as follows, without
burner baffle in place:
1. Yellow flame on burner - open burner air shutter to the widest opening that will not cause the flame to
BURNER BAFFLE
1/2" FLAME
FIGURE 4
.
Distinct blue flame but lifting - close burner air shutter to the point where it will not cause the flame
to lift or blow off the burner when cold. (See #2 on
figure 5.)
LOCK SCREW
3
AIR SHUTTER 2
ORIFICE HO
FIGURE 5
-6-
Gas Conversion
General
All ovens are equipped with double coaxial (universal)
orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it
was adjusted for at the factory. To convert the unit to
either Natural gas or LP gas will require adjustment of the orifice hood and air shutter on the burner and adjustment of the appliance pressure regulator converter cap.
Inlet pressure to the appliance pressure regulator should be as follows for both operation and checking of appliance pressure regulator setting:
INLET PRESSURE IN NATURAL LP INCHES OF WATER COLUMN GAS GAS
Minimum 5 11 Maximum 14 14
off with nut). "IMPORTANT" remove plastic dust cover from cap nut and reinstall on opposite side of cap nut.
Reinstall cap nut to appliance pressure regulator and
replace dust cover. "CAUTION" be sure marking for the type of gas to which appliance pressure regulator has just been converted is visible in top of cap nut before
replacing plastic dust cover. (See figure 7.)
.
Remove cap and forcibly snap out plastic plunger from
bottom of cap. Turn plunger over and forcibly snap
back in original location (figure 8).
NOTE: PLUNGER MUST SNAP INTO POSITION; THE
GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE ON LOWER SIDE OF PLUNGER.
The unitappliance pressure regulator must be set to
match the type gas supply used. If converting from natural gas to LP gas, the appliance pressure regulator must be converted to regulate LP gas. If converting from LP gas to natural gas, the appliance pressure regulator must be converted to regulate natural gas.
TO CONVERT THE APPLIANCE PRESSURE REGULATOR FROM ONE GAS TO ANOTHER, DO
EITHER (1), (2) OR (3) BELOW: YOUR UNIT WILL BE EQUIPPED WITH ONE OF THE THREE APPLIANCE
PRESSURE REGULATOR TYPES SHOWN BELOW.
1. Remove the cap, push down and turn counter-clockwise. Turn the cap over and reinstall
(figure 6). NOTE: THE GAS TYPE YOU ARE CONVERTING TO
MUST BE VISIBLE ON THE TOP OF THE INSTALLED
APPLIANCE PRESSURE REGULATOR CAP.
2. Remove plastic dust cover from cap nut on top of appliance pressure regulator. Remove cap nut from
appliance pressure regulator (plastic dust cover comes
Checking Manifold Gas Pressure
BUILT-IN OVENS:
On built-in ovens, remove 1/8 inch pipe plug from front or side of gas pressure regulator, install 1/8" "B" valve, 1/8
inch piece of pipe, connect manometer, make sure main burner is on to obtain accurate pressure check.
Be sure the gas supply (house piping) pressure is at least one inch (1 ") above specified range manifold pressure. The gas supply pressure should never be over fourteen inches (14") water column.
Checking Pressure Of House Piping System
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 Ibs./sq. in. (13.8 in. W.C.). The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 Ibs./sq. in. (13.8 in. W.C.).
LPG C
FIGURE 6
OO_ f_( _ONAT
L.P. POSITION
,/
ART _ A219-740
OVEN MANIFOLD GAS _ FOR SOME OVEN PRESSURETAP MODELS
j_
FIGURE 7 FIGURE 8
-7-
Orifice Conversion
1. FROM NATURAL GAS TO LP/PROPANE GAS:
a.
Change the appliance pressure regulator from natural to LP setting. (See figure 6, 7 or 8).
b.
Screw the burner orifice hoods down tight against the pins. (See figure 9B). Use care to not over
tighten. Over tightening can damage the coaxial pin inside the orifice hood.
NOTE: On units using Eaton Oven Safety Valve, screw the valve orifice hood down tight against
the valve body. (See figure 9D). It is important that the hood be turned down as far as it can go to insure that complete conversion has occurred.
C.
Adjust burner air shutter to the widest opening
that will not cause the flame to lift or blow off the burner when cold.
NOTE: Correctly adjusted sealed burners, can have flames that will lift or blow without a pot over
the burner. These should be adjusted with a pot in place.
2, FROM LP/PROPANE GAS TO NATURAL GAS:
a.
Change the appliance pressure regulator from LP to natural setting. (See figure 6, 7 or 8).
b.
Screw the burner orifice hoods away from the pins. (See figure 9A). Approximately 1 1/2 to 2 turns.
NOTE: On units using Eaton Oven Safety Valve, screw the burner orifice hoods away from pin (see
figure 9C). Approximately 1 1/2 to 2 turns. Adjust burner air shutter to the widest opening
that will not cause the flame to lift or blow off the burner when cold.
NOTE: Correctly adjusted sealed burners, the
flame will lift or blow without a pot over the burner.
These should be adjusted with a pot in place.
SERVICE - PARTS INFORMATION
WHEN YOUR RANGE REQUIRES SERVICE OR REPLACEMENT PARTS, CONTACT YOUR DEALER OR
AUTHORIZED SERVICE AGENCY. PLEASE GIVE THE
COMPLETE MODEL AND SERIAL NUMBERS OF THE RANGE WHICH IS LOCATED ON THE RANGE MODEL
NUMBER PLATE.
FOR ALL TOP BURNER AND
OVEN SAFETY VALVE CONVERSION
(EXCEPT EATON VALVE)
FIGURE 9A FIGURE 9B
NATURAL GAS LP GAS
SETTING SETTING
FOR EATON
OVEN SAFETY VALVE CONVERSION
FECE HOOD
ART I_ 9219-983-0
FIGURE 9C FIGURE 9D
NATURAL GAS LP GAS
SETTING SETTING
-8-
Loading...