Maytag CWE9030BCB, CWE9030BCE Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
CWE9030BCB and CWE9030BCE
33"
30 1/8"
24"
• Dimensions (Actual Size) •
Minimum cabinet width:
Cutout width:
Cutout height:
Recommended cutout location from floor :
33" 30 1/8" 28 1/8" 34" 24"
Distance from face of cabinet to
outer edge of open door(s):
20 1/2"
Distance from face of cabinet to
front of closed door handle:
Overall unit width:
Overall unit height:
Penetration into cabinet:
4 3/4" 30 1/2" 28" 24"
Distance from opening floor
to centerline of electrical:
24 11/16"
Distance (left) from opening centerline
to centerline of electrical:
2 1/4"
Oven overlap distances when using
cutout dimensions listed above:
Top overlap:
Bottom overlap:
Right side overlap:
see below 0" 3/16"
Left side overlap: 3/16"
• Additional Information •
• Approved for undercounter installation.
• The unit does NOT overlap the top of the opening.
There is a trim piece that covers the top edge of the cutout a very small amount (less than 1/16").
• Maximum cutout width: 30 1/4"
• IMPORTANT: nylon grip nuts that hold crate bottom
must be removed before installation.
• A three-wire, single phase, A.C. 120/208-240 volt,
60Hz cycle electrical system protected by a 30 amp fuse or comparable circuit breaker must be provided . 7/8" O.D. flexible cable 4 feet long is furnished by manufacturer. Mount junction box in area under plywood floor if adequate lower cabinet space is available. Locate 1 1/4" conduit access hole in the back right hand side of the plywood floor.
Cabinet Opening
(not to scale)
2 1/4"
C
L
24 11/16"
Provide for 120/240, 120/208-volt electrical connection in this area.
28 1/8"
34"
Overall Dimensions
(not to scale)
28"
SEE PAGE 2 FOR UNDERCOUNTER INSTALLATION
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
203
24"
30 1/2"
4 3/4"
BN370 • A203B149 • 31469 • 003006 • 112349 • 70812
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
•A complete floor is recommended to prevent unusual drafts and
capable of supporting 160 lbs.
• Minimum distance from bottom of opening to any object protruding
from cabinet face (i.e. cabinet door) directly below: 1" (because it is an air flow area)
• If you are stacking two units: Maximum distance from floor to bottom
of lower oven opening is 7 1/2". Minimum distance from top of lower oven opening to bottom of upper oven opening is 3/4".
• House wire to enter junction box at left side. Range wires to enter
right side of junction box.
• IMPORTANT : CANADA INSTALLATIONS ONLY - Breaker box
provided with oven must be located in an adjacent accessible location on either side of oven (undercounter) or below (wall mount).
• CWE9030BCB : Black.
• CWE9030BCE : Monochromatic White.
• See below for undercounter installation.
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
CWE9030BCB and CWE9030BCE
• Minimum distance from the top of the counter top to the bottom of the oven opening when installing a Maytag Gas cooktop above: 32". Recommended oven opening cutout: 30 1/8" wide by 28 1/8" high. Gas and electrical connections for the cooktop must be located in an adjacent accessible location. For cooktop dimensions please request the proper data sheet.
• Minimum distance from the top of the counter top to the bottom of the oven opening when installing a Maytag electric cooktop above: 29 11/16". Recommended oven opening cutout: 30 1/8" wide by 28 1/8" high. Electrical connections for the cooktop must be located in an adjacent accessible location. For cooktop dimensions please request the proper data sheet.
• When installing 2 units side-by-side, the openings must be separated a minimum of 6". Each unit must have its own electrical box located on the wall of the opening.
25" normal counter top depth
Minimum distance from the top of the counter top when installing a Maytag Gas cooktop above: 32". Gas and electrical connections for the cooktop must be located in an adjacent accessible location. For cooktop dimensions please request the proper data sheet.
Minimum distance from the top of the counter top when installing a Maytag electric cooktop above: 29 11/16". For cooktop dimensions please request the proper data sheet.
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
28 1/8"
30 1/8" minimum
30 1/4" maximum
Recommended cutout:
30 1/8" wide by 28 1/8" high
2 1/4"
C
L
120/240v, 120/208v electrical connection in this area
Cabinet (under counter) Opening
24"
36" countertop height reccomended
BN370 • A203B149 • 31469 • 003006 • 112349 • 70812
(not to scale)
1 1/2" countertop
Distance from top of slat to centerline of electrical: 24 11/16"
Use of 3 1/2" slats on each side recommended
149
Loading...