Maytag 9845VVV, CWE6830ACE, CWE7800ACB, CWE7800ACE, CWE7830ACB Installation Instructions

...
p.-
INSTALLATION
INSTRUCTIONS
PART NO. 210968A
CLEARINGHOUSE
ElECti 1996
1 1/4" Dia Conduit Access Hole*
5/8" PlywOod Floor (Must Support 142 Ibs) _/1
DIMENSIONS
B 2_ 60.96 MIN
C 27 _/16 69.69 ± .16
D 23 1/2 MIN 59.69MIN E _ 64.77 ± .16 F _ 70.49
G _ 67.95 H _ 62.07
10.2 tO83.8
Electric Wall Ovens
Built-In 27" 1
SINGLE WALL OVEN
5/8" Plywood Floor (Must Support 250 Ibs) L- -
- I
A 27MIN 68.56 MIN
s _ 60.96MIN
C 49_16 126.05 ± .16
D 23 1/2 MIN 59.69 MIN E 25 1/2¢1/16 64.77 ± .16
F 4915116 126.84 DOUBLE WALL OVEN G _ 67.95
H _ _.o7 A
i in cm
5i8" Plywood Floor (Must Support 142 Ibs)
1 1/4" Dia Conduit Access Hole*
27 7/16±1/16 69,69±,16
23 1/2 MIN 59.69 MIN
25 1/2±1/16 64.77±.16
D,MENSK_NS I"" B _A
10.2 to 30.5 /
-- __ _ 63.50
24 MIN 60.96 MIN C
_MIN D_IMENslONS
NOTE: Hole mustbe cut as closeto Z
comer ofcabinetas possible.
Electrical Connections
Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz, See serial plate on
front of unit for power requirements,
1. Cut hole in cabinet to mount oven, Cutout in cabinet Theneutralofthis unit isgrounded tothe frame through the should be level and straight, green or solid grounding wire, (The green and the white
wires are twisted together at the termination ofthe conduit,)
Note: There are no provisionsto level the unit after it is If local conditions do not permit grounding of the neutral,
installed. An oven that is not level could cause untwistthe green wire and connect the green wire toground poor baking results, in accordance with local codes. Connect the white neutral
to the service neutral.
2. Installplywood floor as shown.
The chart below recommends the minimumcircuitprotection
3. Attach unit to the cabinet with four No. 8 x 1,_,,screws and wire size if the appliance isthe only unit on the circuit.
supplied with unit inside of envelope containing these instructions. Pre-drill holes in cabinet for attachment
screws using 1/8" drill. Oven mounting holes are provided in side trim. RECOmENDEDMINIMUM
I_W.RATING CIRCUITPROTECTIONWIRES_
4. See instructionsat rightfor electrical hook-up. ONSERIALPLATE INAMPF_S (AWG) 0- 4,8 20 12
5. See Use and Care Manual for operating instructions, 4.9 - 6.9 30 10
7.0- 9.9 40 8
10.0 - 11.9 50 8
12.0 - 14.9 60 6
Instal;ing Bottom Trim Piece
Interrupt the source of electricity to the unit when attempting
to repair or service the oven, Failure to do this could result
_.m--
in a dangerous or even fatal shock.
Service
partNo.210968A
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE 2/96