30-314”
recessed
height
from
underside
of cooktop
to support
slats
28-5132” oven
recessed widt
Your safety and the safety of others is very
important.
We have provided many important safety messages in this
manual and on your appliance. Always read and obey all
safety messages.
q
!
This is the safety alert symbol.
This symbol alerts you to hazards that can kill or
hurt you and others. All safely messages will be
preceded by the safety alert symbol and the word “DANGER”
or “WARNING”. These words mean:
You ~JHJ be killed or
seriously injured if you
don’t follow instructions.
You can be killed or
seriously injured if you
don’t follow instructions.
All safety messages will identify the hazard, tell you how to
reduce the chance of injury, and tell you what can happen if
the instructions are not followed.
/ L
Important: Observe all governing codes and
ordinances. Failure to meet codes and ordinances
could lead to fire or electrical shock.
Proper installation is your responsibility. Have a qualified
technician install this range.
Range location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Recessed installation area must provide complete
depth
enclosure around the recessed portion of the range.
Electrical ground is required. See “Electrical requirements.”
IMPORTANT: Some cabinet and building materials are not
designed to withstand the heat produced by the oven for
baking and self-cleaning. Check.with your builder or cabinet
supplier to make sure that the materials used will not
discolor, delaminate or sustain other damage.
Range support surface MUST be solid, level and flush with
bottom of cabinet cutout.
Countertop preparation:
If countertop thickness is
Front edges: You may need to
more than l-1/2” inches
shave or cut the trim of formed
thick: Countertop must be
or metal front-edged
notched as shown to avoid
countertops to clear the 30”
damaging the oven control
width of cooktop.
panel.
w * in;;;,
30-l 18”
\
If countertop extends more
l-1/8” beyond cabinet front:
Notch countertop as shown
to clear oven control panel.
notch width
both sides
cabinet
wall
\
floor
\
13” max. upper
**F r Minimum
1 cl arances to the
top of cooktop see
Note.
--------
Side view of
cabinet cutout
**Note: 24” min. when bottom of wood or
metal cabinet is protected by not less than
l/4” flame retardant millboard covered
with not less than No. 28 MSG sheet steel,
0.015” stainless steel, 0.024” aluminum or
0.020” copper.
30” min. clearance between the top of the
cooking platform and the bottom of an
unprotected wood or metal cabinet.
Copies of the standards listed may be obtained
l
National Fire Protection Association
Batterymarch Park
from:
Top view of
i -I rz-
max.
countertop
thickness
/9 ~~~~~~xE~evel
frond to back and with
each other.
Top of countertop
Note: countertop
must be level
across front and
front to back.
Locate electrical
Do not seal range to side cabinets.
When installing a cooktop under existing cabinets and the
installation does not meet the minimum cabinet clearances.
Install a range hood above the cooktop to avoid burn
hazards.
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 - latest edition*, and all local codes and ordinances.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety Standards,
Title 24 CFR, Pat-t 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD, Part
280); or when such standard is not applicable, the Standard
for Manufactured Homes Installations (Manufactured Home
Sites, Communities and Setups), ANSI A225.1/NFPA 501A,
or with local codes.*
When this range is installed in mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
Four-wire power supply cable must be used in a mobile
home installation. The appliance wiring will need to be
revised. See four-wire electrical connection, Page 3.
Tools needed:
4
112” dia.
b
router bit
Parts supplied:
-@I3
8
=I=
r
2 screws
2 door removal pins
Ouincy, Massachusetts 02269
Page 1
Front view of
cabinet cutout