Maytag 23-11-2242N-005 Instruction Manual

MA AG
Dehumidifier
For Future Reference
Write down the model and serial numbers The model and serial numbers can be
found back of the unit. Use these numbers in any correspondence or service calls
concerning your dehumidifier.
Model No., Modelo No., N° de modele
Serial No., NOmero de serie, N° de s_rie
Date of Purchase, Fecha de la compra, Date d'achat
866-MAYTAG-1
customerservice@maytagair.com
Important Safety Instructions & Installation oooooooooooooo
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
What You Need To Know About Safety Instructions
Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible
conditions and situations that may occur. Common sense, caution and care must be exercised when
operating or cleaning tools and equipment. Always contact your dealer, distributor, service agent or
manufacturer about problems or conditions you do not understand.
_h_This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Electrical Shock Hazard
1. Plug unit only into grounded electrical outlet.
2. Do not use an extension cord or plug adaptor with this unit.
3. Do not operate unit with filter removed.
Failure to follow the above precautions could result in electrical shock, fire, personal injury or death.
If the dehumidifier has a serial plate rating of 115 volts and up to and including 7.5 amps the unit may be on a fuse or circuit breaker with other devices. However, the
maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse or circuit
breaker.
Notice
Do not operate this dehumidifier without proper time delay circuit protection. Refer to serial plate for proper power supply requirements.
RECOMMENDEDCIRCUITWIRESIZES
PROTECTORSIZE WIREGAUGE
15 AMP #14 MINIMUM
(As installed perbuilding code)
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
C UT,O.I
CAUTION indicates an potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
I CAUTION I
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard or explosion.
Power Supply:
Outlet Requirement: Grounding Type:
Minimum Wire Size:
Circuit Protector:
115V, 60HZ
AC Only 1-Phase 3-Prong
125 V, 15 Amp
#14 (A.W.G.) 3-Wire
Use Copper Wire Only
15 Amp Time Delay Fuse
or Circuit Breaker
Important Grounding Requirements
Your Dehumidifier will operate on any 115 volt, 3-pronged (grounded), 60 Hz circuit. A separate line is not required,
but it is advisable not to overload the circuit with heavy duty appliances such as washing machines, etc. For your
safety, this dehumidifier is equipped with a 3-pronged, grounding plug and must be plugged into a properly
grounded outlet. If your outlet is not of the proper type, it is your responsibility to have the outlet and wiring
changed to the correct type. DO NOT cut off the third (grounding) prong. DO NOT USEAN ADAPTER.
Installation
Close Windows and Doors
To assure efficient dehumidification, close all windows and doors in the area where the dehumidifier isto operate.
Plug In
Once you have assembled your dehumidifier and installed it in an appropriate location, plug the cord into a properly
grounded outlet as indicated in the electrical requirement,
Operation & Maintenance °oooooo°oo°oo°oooooooo°°oo°oo°oooooooo
Automatic Humidity Control
The humidistat control automatically turns your
dehumidifier on or off to maintain the humidity level you select. Allow dehumidifier to reach room temperature,
then turn control knob to number 5 (normal average
setting). The fan and compressor will run together, dehumidifying the room. If unit does not turn on at this
setting, this generally means that the relative humidity is already low and dehumidification may not be needed at
this time.
After operating several days at this setting with doors and windows closed, you may readjust this control to a slightly
higher number for lower humidity (drier air) or to a slightly lower number for higher humidity (moist air).
If knob is turned to "Continuous Run" then the compressor will continuously run regardless of actual room humidity. If not properly monitored, this setting could cause excess energy usage.
Humidistat r ....
Humidistat/Power Control
To empty the Container:
1. Unplug unit before removing container. Wait 3 minutes for any remaining water to drain into the
condensate container.
2. Tilt the container forward then lift carefully by the handle.
3. Empty and gently re-insert the container.
Important: This water is not suitable for drinking.
...................... - ..............
_te Condensate
Container Drain
Note: A piece of tape is
attached to the container to ensure safe
shipping. This piece of tape may be removed.
Overflow Indicator
An automatic overflow switch and indicator light are provided to turn the dehumidifier off before the container
overflows. When the indicator light on the control panel glows, the water container must be emptied.
+ ++++
lira lY+e
Overflow
Indicator
Filter Cleaning
1. Unplug unit.
2. Use a vacuum cleaner attachment or brush to clean the front grille.
3. Remove the filter.
4. To clean the filter, wash in warm, soapy water, rinse and shake dry. Cleaning is recommended monthly, or
as conditions require.
Filter
Maintenance oooooooooooooooooooooooooooooooooooooooooooooooooo
Permanant Drain Installation (optional):
The condesate water can be removed directly from the
unit to a drain through a garden hose with the included adapter.
1. Unplug unit before beginning work.
2. Use a screwdriver to remove the knock-out at the back of the unit.
3. Slide the garden hose adapter (supplied) over the condensate drain through the knock-out hole.
4. The garden hose should lead to a floor drain or other appropriate drain source. The garden hose should
have no inclines or sharp bends.
Permanant drain
Service (Read carefully before calling for service)
If the Dehumidifier Fails to Start
Make sure the unit is plugged into an operating outlet.
If the indicator light (most models) is on, empty the full water container. The indicator light should now go OFF,
and the dehumidifier will begin to operate. If the dehumidifier does not begin to operate make sure the
float is attached to the water container.
Unit Runs, But Very Little Water is Collected
The amount of water removed from the airdepends on the relative humidity of the air and the capacity of the
dehumidifier purchased. When the air feels damp (high relative humidity), more moisture will be removed and
the container will fill up more rapidly. As the unit continues to remove moisture and reduce the humidity
in the area, less water will be collected in the container.
Room humidity is low (below 40%).
Sounds
It is reassuring to know that your dehumidifier is functioning properly. These are some normal sounds which
should not be a cause for concern:
Air rushing over air drying coils.
Hissing or thumping - refrigerant is flowing throughout the sealed system and may generate a "boiling" sound
right after the compressor stops.
Compressor may "thump" as it cycles on and off.
Water dripping from coils onto the drain plate.
The humidistat control, compressor and fan "tick" as they turn on and off. Metal makes a similar sound when
expanding or contracting.
Condensate
Drain
Hose Adapter
Garden Hose
Service & Warranty
@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
How to Obtain Warranty Service or Parts
Service for your dehumidifier will be provided by CareCo, a division of the manufacturer with authorized independent
CareCo servicers nationwide.
Note: Before calling for service, carefully read the Installation and Operating Instructions booklet. Then if you need service:
1. Call a CareCo authorized servicer and advise them of model number, serial number, date of purchase and
nature of complaint. Service will be provided during normal working hours. Contact your dealer for the name
of an authorized servicer if unknown to you.
2. If your dealer is unable to give you the name of a servicer or if you need other assistance, call the following toll-free
number for the name of an authorized servicer or
authorized parts distributor:
1-866-M AYTAG 1
or you may write: CareCo, Service Department 415 W. Wabash Ave., RO. Box 200
Effingham, IL 62401
Proof of Purchase Date It is the responsibility of the consumer to establish the
original purchase date for warranty purposes. We recommend that a bill of sale, cancelled check, or some
other appropriate payment record be kept for that purpose. For Models Installed Outside North America
For dehumidifiers purchased for use outside North America, the manufacturer does not extend any warranty
either expressed or implied. Consult your local dealer for any warranty terms extended by the importer in your
country.
Room dehumidifier Warranty
(Within the 48 contiguous United States, state of Hawaii, the District of Columbia, Puerto Rico and Canada)
Full (Five Year) Parts and Labor Warranty During the five years after the date of original purchase,
CareCo will, through its authorized servicers and free of charge to the owner or any subsequent user, repair or
replace any parts which are defective in material or workmanship due to normal use when the unit is delivered
by the owner to and picked up from one of our authorized servicers. If requested, in-home service, pick-up, redelivery
and reinstallation will be provided, but are the owner's responsibility.
Note: In the event of any required parts replacement within the
period of this warranty, CareCo replacement parts shall be used and
will be warranted only for the period remaining on the original
warranty.
Exceptions The above warranty does not cover failure to function
caused by damage to the unit while in your possession (other than damage caused by defect or malfunction), or by
its improper installation, or by unreasonable use of the unit, including without limitation, failure to provide reasonable
and necessary maintenance or to follow the written Installation and Operating Instructions. If the unit is put to
commercial, business, rental, or other use or application other than for consumer use, we make no warranties,
express or implied, including but not limited to, any implied warranty of merchantability or fitness for particular use or
purpose. THE REMEDIES PROVIDED FOR IN THE ABOVE EXPRESS
WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES THEREFOR, NO OTHER EXPRESS WARRANTIES ARE MADE. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED
TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE, ARE LIMITED
IN DURATION TO FIVE YEARS FROM THE DATE OF ORIGINAL PURCHASE. IN NO EVENT SHALL CARECO BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. NO WARRANTIES, EXPRESS OR IMPLIED, ARE
MADE TO ANY BUYER UPON RESALE.
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty
gives you specific legal rights, and you may also have other rights which may vary from state to state.
No warranties are made for units sold outside of the above stated areas. Your distributor or final seller may provide a
warranty on units sold outside of these areas.
4
Loading...
+ 11 hidden pages