INSTALLATION
INSTRUCTIONS
Built-In 30″ Electric
Combination Wall Ovens
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
COMBINATION
30″ WALL OVEN DESCRIPTION
11-1/4″ Dia. Conduit Access Hole*
25/8″ Plywood Floor (Must Support 250 lbs.)
DIMENSIONS
in cm
A 30 MIN 76.20 MIN
B 24 MIN 60.96 MIN
C47+
D 24 MIN 60.96
E 28-1/2 +
F 47-5/8 120.97
G 29-3/4 75.57
H 24-7/16 62.07
I 4 to 20 10.2 to 50.8
* Hole must be cut as close to corner of cabinet as possible.
Z Do not block air intake slots along bottom of oven.
1/16 119.38 + .16
1/16 72.39 + .16
NOTES
INSTALLATION
1. Cut hole in cabinet to mount oven. Cutout in
cabinet should be level and straight.
NOTE: There are no provisions to level the unit
after it is installed. An oven that is not level could
cause poor baking results.
2. Install plywood floor as shown above.
3. Install top mounting bracket -- also refer to
template.(figure 3)
Top bracket mounting installation
instructions:
a. Before installing unit into the cabinet, open
microwave door, remove the two upper screws in
the trim kit holding the top mounting bracket (see
figure 1 next page) and set the bracket and
screws to the side.
b. Using scissors cut along the cut line on the
template (provided).
c. Find the center of the cabinet cutout.
d. Align the template ”center of opening” to the
center of the cabinet cutout making sure the top
of the cabinet cutout corresponds with the
template ”top of opening” indicator line. Tape may
be used to hold the template temporarily in place.
e. Locate and mark screw holes (A) at both
ends, 2 each side, of template.
f. Remove template and set it to the side.
g. Drill pilot holes into cabinet using 7/64” or
#35 drill bit.
h. Install top mount bracket (from step 3a) to
cabinet with the provided wood screws. (1/2” X 4)
WALLOVEN CUTOUT
CAUTION
For European style cabinets (flush front) the required
clearance for operation of the oven door is minimum
spacing of 7/8″ between the cutout and the door, hinge
or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due
to their construction, to allow this installation.
Top bracket mounting installation instructions:
(continued)
i. Install and push unit in until trim frame engages with top
mount bracket.
j. Drive two screws that were removed in step (a) Do not
over tighten the screws.
4. Attach unit to the cabinet with 4 No. 8, flat head screws
supplied inside of envelope containing these instructions.
Pre--drill holes in cabinet for attachment screws using 1/8,
drill. Oven mounting holes are provided in side trim.
5. See instructions ”Electrical Connections” for electrical
hook--up.
6. See figure 2 next page for lower trim installation.
7. See User’s Manual for operating instructions.
8101P744-60
(11-06-00)
FIGURE 1
FIGURE 2
ELECTRICAL CONNECTIONS
Unit to be properly circuit protected and wired according to
local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
each unit for power requirements.
The neutral of the lower unit is grounded to the frame
through the green or solid grounding wire. (The green
and the white wires are twisted together at the
termination of the conduit.) If used on new branch--circuit
installations (1996 NEC), mobile homes, recreational
vehicles, or in an area where local codes prohibit
grounding through the neutral conductor, untwist or
disconnect the green wire and connect the green wire to
ground in accordance with local code. Connect the white
neutral to the service neutral. Connect all wires to the
branch circuit with approved connectors. Use copper or
aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit
on the circuit.
Remove lower screws from hinge receptacle plates. Align
lower trim and reinstall screws.
NOTE: Lower trim overlaps front edge of cabinet by 9/16″.
Improper installation of the grounding
circuit can result in a risk of electric
shock.
Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, or
if doubt exists as whether the appliance is properly
grounded.
SERVICE
Interrupt the source of electricity to the unit when
attempting to repair or service the oven. Failure to do
this could result in a dangerous or even fatal shock.
FIGURE 3 Sample Template -- not to scale
RECOMMENDED MINIMUM
K.W.RATING CIRCUIT PROTECTION WIRE SIZE
ON SERIAL PLATE IN AMPRES (AWG)
0 -- 4.8 20 12
4.9 -- 6.9 30 10
7.0 -- 9.9 40 8
10.0 -- 11.9 50 8
12.0 -- 14.9 60 6
IMPORTANT -- SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE