Maxwell MS-C2PSU, MS80C2PU, MS100C2PU, MS120C2PU, MS150C2PU Installation Manual

...
Tankless Electric Water Heater
MS-C2PSU Series
Installation and Instructions Manual
Keep this Instructions Manual in a safe place once your unit is installed.
You may need to refer to it for general instructions or future maintenance.
Thank you for purchasing a quality Maxwell tank-less electric water heater. To enjoy your new shower at its best, please take time to read this manual thoroughly and having done so keep it handy for future reference.
CONTENTS
Important Safety Instructions -------------------------------------------------------------------------------- page 2
Electrical Diagram------------------------------------------------------------------------------------------------ page 3
Technical Data and Product Structure----------------------------------------------------------------------page 4
Installation Guideline---------------------------------------------------------------------------------------------page 6
Operation Instructions ------------------------------------------------------------------------------------------page 10
Trouble-shooting---------------------------------------------------------------------------------------------------page 11
Normal Maintenance----------------------------------------------------------------------------------------------page 11
Accessories--------------------------------------------------------------------------------------------------------page 12
MODEL NUMBER
M
S
1 2
0
C
2
W P
U
NOMENCLATURE
Test Calification
U : UL/ETL C : CSA
Casing Type & Color
B: Injection Molding – Black D: Injection Molding – Silver w/Dots S: Injection Molding – Silver W:Injection Molding – White M:Metal Casing – Silver
Minor Design Change
P : Plate Heater Exchanger T : Tubular Stainless
Steel Heat Exchanger
This Klimaire nomenclature supercedes all previously issued (06/07/2011)
Power Supply Code (V/ph)
1 – 120 / 1 2 – 240 / 1 5 – 240 / 3
Temperature Control
C : Automatic Constant P : Power Level
Capacity (kW)
035 – 3.5 045 – 4.5 055 – 5.5 075 – 7.5 080 – 8.0
Heater Type
S : Tankless H : Holding Tank
Brand: M: Maxwell
100 – 10.0 120 – 12.0 150 – 15.0 180 – 18.0 210 – 21.0
11
Installation of this product is restricted to indoor locations by licensed plumbing or electrical contractors only. By installing this product you acknowledge the terms of manufacturer's warranty and your authorized dealers return policy. Water heaters that have been installed cannot be returned. If you plan to install your water heater on a second floor/above ground or in a heated attic space you must follow all code requirements for installation in your area. It is highly recommended to install a drip pan connected to a safe drain as per code requirements, below the water heater to avoid property damage in case of eventual leaks, and / or install an active water leak detector and shut off valve to turn off your water supply in the event that a leak is ever detected.
Important Safety Instructions
1. The installation must be in compliance with the National Electrical Code, your local electrical and
plumbing codes.
2. This appliance must be GROUNDED.
3. All wiring and installation jobs must be supervised by a qualified electrician.
4. CAUTION: This product has more than one power-supply connection point. Disconnect all power supplies
before servicing.
5. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
6. This appliance MUST be permanently connected to a fixed circuit breaker and it must be installed vertically. DO
NOT install this appliance near flammable substances or near a strong magnetic field place.
7. It is forbidden to switch on this appliance if you think it may be frozen, as this could result in serious damage to
the unit. Wait until you are sure that it has completely thawed out before switching it on.
8. Please check the hot water temperature with your hand to make sure it is at a comfortable temperature before
taking a shower to avoid getting scalded.
9. Before connecting pipes to the water heater hoses, it is extremely important to FLUSH the pipes to wash away all
plumbing paste or residue in the pipes.
10. The heating chamber is treated with composite nano-insulation material; it is natural there might be a bit of smell
or green blue smoke when the unit is used for the first time.
11. If there is damage to the wire, you must contact a qua lified electrician to replace it with an approved wire.
12.
CAUTION: FOR HOUSEHOLD AND INDOOR USE ONLY
13. Combustible materials should be kept at least 2 ft away from your water heater and output water pipe.
14. AFTER TIGHTENING BOTH FITTINGS AT THE WATER HEATER OPEN SEVERAL HOT WATER FAUCETS AND ALLOW WATER TO RUN THROUGH THE WATER HEATER FOR AT LEAST 3 MINUTES. THIS PROCESS PURGES ALL AIR FROM THE WATER LINES AND HEATER. HIS PROCESS MUST BE PERFORMED PRIOR TO TURNING ON THE POWER OF THE WATER HEATER. FAILURE TO FOLLOW THIS STEP CAN CAUSE PERMANENT DAMAGE TO THE HEATING ELEMENT.
2
Product Features
The Maxwell tank-less electric water heaters are made with multi-safety devices patented technology Additionally, the unit has the following features.
1. Tank-less, instantaneous heating on demand. No pr e-heating. No stand-by heating loss energy-saving.
2. Micro-computer control, adopting patented heating technology. Water is completely separated from electricity by multi-layers of composite nano insulation material.
3. Over-heating thermal cut-off. When the outlet water temperature reaches over 140/60ºC, the electricity will be cut off automatically to avoid getting scalded and the screen beeps and displays E1.
4. Creepage protection. If the unit detects electricity leakage, the electricity will be cut off within mil seconds by the creepage protector and the screen displays E2.
5. Malfunction sensor- when the temperature sensor malfunctions, the heater stops working and displays E3
6. Conversion between Fahrenheit degrees and Celsius degrees.
7. This product does not require venting.
AC 240V/60Hz
3
Technical Data
Model MS80C2P_U MS100C2P_U MS120C2P_U MS150C2P_U MS180C2P_U MS210C2P_U
Phase
Voltage/Freq V
Wattage kW
Max. amp.load A
Min. required circuit breaker*
A
Min. wire size AWG cooper
Min. water flow to activate
GPM / L/min.
Working pressure PSI/bar
Weight
Product Dimensions
Water connections NPT
Note: *suitable recognized strain relief means shall be provided when the product installed.
kg
mm
lb
in
1 1 1 1 1 1
240 V/60Hz 240 V/60Hz 240 V/60Hz 240 V/60Hz 240 V/60Hz 240 V/60Hz
8kw 10kw 12kw 15kw 18kw 21kw
34 42 50 63 75 88
45 60 60 2 X 40 2 X 50 2 X 60
8 6 6 2 X 8 2 X 8 2 X 8
0.53 / 2 0.53 / 2 0.53 / 2 0.85 / 3.2 0.85 / 3.2 0.85 / 3.2
Max.150/10
7.7 7.7 7.7 12.1 12.1 12.1
3.5 3.5 3.5 5.5 5.5 5.5
385x260x93
15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7"
385x260x93 385x260x93 385x260x93 385x260x93 385x260x93
1/2” 3/4” 3/4” 3/4” 1/2” 1/2”
(MS150, MS180, MS210)
11.02"
16.14"
WIRE CONNECTIONS TO BREAKERS (MS150, MS180, MS210)
L1 L2 L1 L2
DOUBLE POLE BREAKER
40 Amp MS150 50 Amp MS180 60 Amp MS210
DOUBLE POLE BREAKER
40 Amp MS150 50 Amp MS180 60 Amp MS210
E / G
EARTH/
GROUND
4