Heater Sizing GuideHeater Sizing Guide
SERIES
There are many factors that go into selecting the right water heater: the number of people in the home, type of showers and tubs, water pressure and geographic region. To make the process easier, we offer the map and flow-rate table below.
2. In the corresponding column select the water heater based on how many fixtures you'll be running at the same time.
3. The temperatures shown above are based on the average coldest ground temperature in your region.
Heater Sizing Guide
Summer Winter
Inlet Water
Model Nº
Temp.
MS120C2P_U
MS150C2P_U
MS180C2P_U
MS210C2P_U
MS240C2P_U
MS270C2P_U
Shower (1.5 gpm) ― Sink Faucet (1.0 gpm) All data above are based on water leaving temperature 105º F (40º C). 1.5 gpm showerhead flow rate; 1.0 gpm sink faucet flow rate, and adequate water pressure @ 60 psi. Actual performance may be altered by variations from these parameters. For voltages less than 240 V the heating capacities will vary and it would be necessary to consider a higher capacity model.
77º F 72º F 67º F 62º F 57º F 52º F 47º F 42º F 37º F
2.7 gpm 2.4 gpm 2.2 gpm 2.1 gpm 1.8 gpm 1.5 gpm 1.3 gpm 1.2 gpm 1.1 gpm
3.5 gpm 3.2 gpm 2.6 gpm 2.5 gpm 2.3 gpm 2.0 gpm 1.7 gpm 1.5 gpm 1.3 gpm
4.0 gpm 3.6 gpm 3.2 gpm 3.0 gpm 2.7 gpm 2.5 gpm 2.3 gpm 2.1 gpm 1.8 gpm
5.0 gpm 4.5 gpm 3.8 gpm 3.5 gpm 3.2 gpm 2.7 gpm 2.4gpm 2.2 gpm 2.1 gpm
5.6 gpm 4.8 gpm 4.2 gpm 3.5 gpm 3.3 gpm 2.8 gpm 2.6gpm 2.4 gpm 2.2 gpm
6.4 gpm 5.3 gpm 4.7 gpm 4.0 gpm 3.6 gpm 3.3 gpm 3.0gpm 2.7 gpm 2.5 gpm
Shower Sink Faucet