Maxwell MASF048N1H User Manual

Page 1
Maxwell
Maxwell
USER’S MANUAL
AIR CURTAIN
MASF036-N1
MASF048-N1 MASF060-N1
THANKS FOR PURCHASING AIR CURTAIN, PLEASE READ IT CAREFULLY BEFORE USING
THANKS FOR PURCHASING AIR CURTAIN, PLEASE READ IT CAREFULLY BEFORE USING
Page 2
1IDENTIFICATION & INSTALLATION DIMENSIONS
MODEL A B C D E F G H I
MASF036-N1
MASF048-N1
MASF060-N1
35.4 27.4 --- --- 1.8 3.9 8.5 9.1 4.8
47.2 39 11.6 ---
59 50.6 19.8 ---
2INSTALLATION CAUTION
Must follow the following asking when installing air curtain
2.1 Please install the unit in a sturdy place to avoid the shaking and ensure its security (because it maybe cause the wall becoming flexible or shaking and noise.
2.3 Don’t install the unit too low, no less than 2.3 meter from the ground.
2.4 When the entrance is wider than the unit, it is recommended to install two or more units in parallel. In this case, provide 20-40mm gaps between the units.
2.2 Please install the unit inside the room.
Page 3
2.5 Don’t allow gaps between the unit and the wall. When hanging it from the ceiling, using the enclosed ceiling braskets.
3INSTALLATION
A Installing on the concrete wall:
2.6 Don’t install the unit in a place where it is splashed by water, exposed to excessive steam, explosive gas or corrosive gas.
3.1.1 Removed the mounting plate Unclamping the fixed screws on the back of
main body to removed the mounting plate.
3.1.3 When the cement has freeze, fit the
mounting plate (use the washer and nut according to the following)
3.1.2 Fix the bolts in the proper position (Decide the position with the mounting plate and pour cement into the bolt holes.)
3.1.4 Install the main body Set the main body onto the upper end of the
mounting plate and clamp it as shown.
BInstalling on the wooden wall
3.2.1 Fix the mounting plate in the proper positions with tapping screw.
3.2.2 Same as the step 3 of A
Page 4
CHanging from the ceiling
3.3.1 Remove the mounting plate from main body
(Same as step3.1.1)
3.3.3 Set the mounting plate on the ceiling brackets and ensure safe & fixing (use the bolts attached to the ceiling brackets as Fig. Using the ceiling brackets to hang from the ceiling, the position of mounting plate can be adjusted in the limit of 100mm.
3.3.2 Fixing ceiling brackets as Fig.
3.3.4 Do the same as step A to install the main body.
DFor above ceiling
3.4.1 Fix the air curtain as in the procedure for installing on the concrete wall.
3.4.2 Then pipe as
4TECHNICAL PARAMETER
MODEL
MASF036-N1 110 60 230 200 52.5 42.7 647 530 52 49 28.7
MASF048-N1 290 260 883 707 53 50 34.2
MASF060-N1 380 350 1120 883 55 52 44
Volt.
(V~)
Freq (Hz)
Max input
power
(W)
H L H L H L H L
Max air
speed
(ft/s)
Air volume
(cfm)
below
Fig. Instructs.
Noise
(dB)
Net
weight
(LBS)
Page 5
5ELECTRIC WORK
YELLOW
C
Lo
K
OFF
Hi
BLACK
BLUE
WHITE
GREY
BLUE
ORANGE
(YELLOW)
THERMAL CUT-OUT
RED
BLACK
BLUE
YELLOW
ORANGE
(YELLOW)
THERMAL CUT-OUT
C C
RED
L
N
BROWN
GREEN
DOUBLE SPEED SWITCH WIRING DIACRAM
BLACK
YELLOW
ORANGE
(YELLOW)
RED
BLUE
THERMAL CUT-OUT
Optional door switch & weather proof cover Save energy & eliminate unnecessary air circulation
COM – common NO – normally open NC – normally close
6OPERATION
6.1 Turn on the power switch
6.2 Select the best speedHigh[H]、Low[L]
6.3 According to the installation place to adjust the wind direction parts to obtain the best effect.
7CAUTIONS
a)、Use the unit at the rated voltage and frequency indicated on the nameplate. b)、Disconnect power source before unit operation. c)、Routing maintenance must be done every year. d)、Never use petrol,benzese,thinner or any other such chemical for clearing the unit. e)、Don’t allow water or anything enter the motor. f) 、When power supply comes from socket, the plug must accord with IEC335-1.When the power cord is connected with charging line directly, all polarity switches that the contact gap is 3mm at least must be installed in the charging line.
Page 6
Maxwell
Maxwell
Made by
Rockwell
2190 NW 89 Place, Doral, FL 33172 USA
Tel: (305)594-4972 Fax (305) 675-2212
www.rockwellus.com sales@rockwellus.com