Maxview MHA12CD/S, MHA23CD/S Instruction Manual

MHA23CD/S
1 x Group C/D
680-860
23dB
3dB
108dBµV 103dBµV 102dBµV
10dB 10dB
1
Available
‘F’ connector
Yes
MHA12CD/S
1 x Group C/D
680-860
12dB
2.7dB
112dBµV 107dBµV 106dBµV
10dB 10dB
1
No
‘F’ connector
Yes
Model
Inputs Bandwidth (MHz) Gain Noise Figure Max O/P -46dB Cross Mod 2 TV Channels 4 TV Channels 5 TV Channels Input RLR (75ohm) Output RLR (75ohm) No. of Outputs 12V Power Requirement Through Line Powering R.F. Connector Type Fully Screened
Introduction
The Maxview medium and high gain group C/D ‘Precision’ masthead amplifiers feature low noise figures and are designed to improve signal performance in weak UHF TV group C/D signal areas. The input filtering provides good rejection of out of group TV signals. They are suitable for mast fixing with the releasable cable tie provided or for wall fixing using the drill out tabs. The ‘Precision’ masthead amplifiers are fully screened and suitable for use in either professional MATV or domestic systems. The amplifiers are designed for indoor or outdoor use, and for mounting close to the antenna, requiring +12V d.c. line powering from either the MHP1, MHP2 or MHPL1 power supply units.
The medium gain MHA12CD/S provides excellent performance in smaller systems utilising relatively short cable runs (approx. <15m). The high gain MHA23CD/S Group C/D amplifier is ideally suited for either small or larger systems where longer cable runs may be employed. The MHA23CD/S caters for extremely weak signals and/or long cable run installations and is provided with a cascade line power option.
Maxview reserve the right to alter their designs or specifications without prior notice.
The figures quoted are typical and are subject to normal production tolerances.
Performance Specifications
Typical Applications
User Instructions - Fully Screened Medium and High
Gain Group C/D ‘Precision’ Masthead Amplifier Range
MHA12CD/S MHA23CD/S
GROUP C/D UHF AERIAL
MHA12CD/S
AE
MHP PSU
+12V d.c. LINE POWER
AMPLIFIED GROUPC/D
UHF TV SIGNALS
TV
TV
PLATE
230V MAINS INPUT
Single UHF Amplifier Application For Weak Group CD Signal Areas
GROUP C/D UHF AERIAL
MHA12CD/S
AE
MHP PSU
+12V d.c. LINE POWER
LINE POWER
AMPLIFIED GROUPC/D
UHF TV SIGNALS
TV
TV
PLATE
230V MAINS INPUT
Single UHF Amplifier Application For Very Weak Group CD Signal Areas
MHA23CD/S
9111099 Iss 3
1. Installation Recommendations
1.1 For optimum performance and to provide the best interference free reception we recommend that these guidelines are followed when installing your masthead amplifier.
Mount the masthead/aerial combination as high as possible with a clear line of sight towards the transmitter.
Always use a good quality screened coaxial cable, such as cable conforming to BS5425:Part 1:1986 for the installation.
Fit the masthead amplifier no closer than 50cm and no more than 1m from the associated aerial. Ensure that the distance between
two UHF TV aerials on a mast is at least 60cm-65cm.
In order to minimise potential pick up, install the masthead/aerial combination and coaxial downlead away from overhead signal,
telephone and power cables.
2. Mounting Details
2.1 Undo the snap lock latches either side of the masthead outer housing and hinge the lid open.
2.2 Remove the inner diecast housing.
2.3 If fixing to a mast use the releasable cable tie provided. If fixing to a flat surface, locate drill-out tabs and remove the required tabs
on the inside wall of the outer housing and screw through these specially prepared areas.
2.4 Route the cables to the masthead housing. We recommend DS81, DS100 good quality screened coaxial cable with mating ‘F’ connector to suit. Prepare the cable and attach ‘F’ connectors (integral ‘O’ ring recommended) to the end of the cables. Screw the cables securely to the correct input and output connections on the bottom of the inner diecast housing.
2.5 Replace the inner diecast housing into the outer housing ensuring the cables are positioned in the cable guides. Close the plastic lid and seal by fastening the snap lock latches. Fix the cable to the mast by using tape to hold all cables securely in position.
3. Cascade Line Powering
3.1 This is provided as standard on the group C/D UHF antenna input of the MHA23CD/S to cater for extremely weak UHF TV signals and/or long cable run installations. When cascading amplifiers we recommend that the masthead amplifiers be cascaded either with a screened masthead amplifier or a screened signal booster (located indoors). Ensure that there is a minimum of approx. 10-15m of cable between amplifiers connected in cascade.
3.2 If through line powering is required, peel back, but do not remove, the silver EMC tape on the left hand side of the inner diecast housing. Insert the line power link (PL1) through the guide slot and into (SK1) and make sure it is pushed fully home. Re-seal the tape across the hole. If the line power link needs to be removed, use long nose pliers to carefully remove it from the guide slot.
4. Power supply
4.1 The MHP1 (single output) and MHP2 (twin output) plug-in power supply units or the fully screened MHPL1 single output power supply unit can be used with a single amplifier or multiple amplifier installations where up to 2 amplifiers may be required. The MHP2 incorporates signal splitting to provide an additional wideband TV output. Connect the +12V line power output of the MHP unit to the TV/MHP terminal on the masthead amplifier.
4.2 Ensure that all installation work is completed before plugging in and switching on the associated power supply unit.
Many other installation possibilities exist for masthead amplifiers. Should you have any questions or require any assistance with system planning please contact the Maxview Customer Helpline on 01553 811000.
9
111099 Iss 3
Snap lock latches
Cable guides
Fully screened diecast inner housing
Fully weatherproof outer housing
Type ‘F’ RF connectors
Drill-out tabs (wall mounting only)
Line power guide slot
EMC tape
Model used for
illustration purposes only
Line power link
(PL1)
MAXVIEW LTD.COMMON LANE .SETCHEY.KING’S LYNN.NORFOLK.PE33 0AT.ENGLAND
CUSTOMER HELPLINE (01553) 811000 FAX (01553) 813301 e-mail: cust_serv@maxview.ltd.uk website: www.maxview.ltd.uk