![](/html/bc/bc34/bc3429cd4babc380e5feda5a227a10868d84799afc0d450ad3a5d4aa9bfea4bd/bg1.png)
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-77CE March 13, 1996
Camera
Interface
Overview
Camera
Interface
Details
• 739 x 570 x 8-bit (CCIR) @ 25fps
• Interlaced
• Internal or external sync
• 14.1875MHz pixel clock rate
• 3 modes: continuous mode (internal sync), continuous mode (external sync), restart reset
mode
1. Continuous mode (internal sync)
• 739 x 570 x 8-bit (CCIR) @ 25fps
• Interlaced
• Continuous video
• Internal (composite) sync
• DCF used: 77CE.DCF
SONY
XC-77CE
Video
Matrox Pulsar
(with PLS-TTL-CABLE)
2. Continuous mode (external sync)
SONY
• 739 x 570 x 8-bit (CCIR) @ 25fps
• Interlaced
• Continuous video
• Matrox Pulsar sending TTL hsync (HD IN) and vsync (VD IN) signals to camera
• DCF used: 77CEM.DCF
XC-77CE
Video
HD IN
VD IN
Matrox Pulsar
(with PLS-TTL-CABLE)
Cabling
Requirements
3. Restart reset mode
SONY
XC-77CE
• 739 x 570 x 8-bit (CCIR) @ 25fps
• Interlaced
• Matrox Pulsar receiving TTL external trigger
• Matrox Pulsar sending TTL hsync (HD IN) and vsync (VD IN becomes RR trigger)
Video
HD IN
VD IN
TTL external trigger
Matrox Pulsar
(with PLS-TTL-CABLE)
signals to camera
• DCF used: 77CEMT.DCF
1. Continuous mode (internal sync)
• IMG-7W2-TO-1BNC and Sony JB-77 junction box required
• Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
![](/html/bc/bc34/bc3429cd4babc380e5feda5a227a10868d84799afc0d450ad3a5d4aa9bfea4bd/bg2.png)
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-77CE March 13, 1996
Cabling
Requirements
Continued
2. Continuous mode (external sync)
• IMG-7W2-TO-1BNC, PLS-TTL-CABLE and Sony JB-77 junction box required
• Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
• The connections between the DB-37 connector of the PLS-TTL-CABLE and the Sony JB-
77 junction box are as follows:
PLS-TTL-CABLE JB-77 Junction Box
(DB-37 connector) (BNC connectors)
Pin name Pin no. BNC name
TTL_HSYNC 26 → HD IN
TTL_VSYNC 11 → VD IN
GROUND 6 & 7 HD IN (GND)
GROUND 6 & 7 VD IN (GND)
3. Restart reset mode
• IMG-7W2-TO-5BNC, PLS-TTL-CABLE and Sony JB-77 junction box required
• Video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
• The connections between the DB-37 connector of the PLS-TTL-CABLE and the Sony JB-
77 junction box are as in continuous mode (external sync) (i.e., VD IN becomes restart
reset)
• TTL external trigger source should be connected to the TTL Trigger Input of the IMG-
7W2-TO-5BNC cable
Special
Considerations
NOTE: all connections in this application note assume the use of the Sony JB-77 junction
box. These connections can also be made directly with the 12-pin connector on the
camera; consult the Sony XC-77CE documentation for a pinout description of this
connector. Contact your local sales representative or Matrox Sales Office, or
contact Matrox Imaging Applications at (514) 822-6061 for assistance.
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp.matrox.com). The information furnished by
Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual.
Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
CorporateCorporate
Headquarters:Headquarters:
Canada and U.S.A.Canada and U.S.A.
Matrox ElectronicMatrox Electronic
Systems Ltd.Systems Ltd.
1055 St.Regis Blvd.
Dorval, Quebec, Canada
H9P 2T4
Tel: (514) 685-7230
Fax: (514) 822-6273
PUL-CID-001 2
Sales Offices:Sales Offices:
U.K.U.K.
Matrox (UK) Ltd.Matrox (UK) Ltd.
Sefton Park, Stoke Poges
Buckinghamshire
U.K. SL2 4JS
Tel: +44 (0) 1753 665500
Fax: +44 (0) 1753
665599
FranceFrance
Matrox France SARLMatrox France SARL
2, rue de la Couture,
Silic 225
94528 Rungis Cedex
Tel: (0) 1 45-60-62-00
Fax: (0) 1 45-60-62-05
GermanyGermany
Matrox GmbHMatrox GmbH
Inselkammerstr.8
D-82008
Unterhaching
Germany
Tel: 089/614 4740
Fax: 089/614 9743
Asia PacificAsia Pacific
Matrox Asia LiaisonMatrox Asia Liaison
OfficeOffice
Rm. 1901, 19/F, Workington
Tower,
78 Bonham Strand E.,
Sheung Wan, Hong Kong.
Tel: 852.2877.5387
Fax: 852.2537.9530