Maxtor XC77CE User Manual

Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-77CE March 13, 1996
Camera Interface Overview
Camera Interface Details
739 x 570 x 8-bit (CCIR) @ 25fps
Interlaced
14.1875MHz pixel clock rate
3 modes: continuous mode (internal sync), continuous mode (external sync), restart reset
mode
1. Continuous mode (internal sync)
739 x 570 x 8-bit (CCIR) @ 25fps
Interlaced
Continuous video
Internal (composite) sync
DCF used: 77CE.DCF
SONY
XC-77CE
Video
Matrox Pulsar
(with PLS-TTL-CABLE)
2. Continuous mode (external sync)
SONY
739 x 570 x 8-bit (CCIR) @ 25fps
Interlaced
Continuous video
Matrox Pulsar sending TTL hsync (HD IN) and vsync (VD IN) signals to camera
DCF used: 77CEM.DCF
XC-77CE
Video HD IN VD IN
Matrox Pulsar
(with PLS-TTL-CABLE)
Cabling Requirements
3. Restart reset mode
SONY
XC-77CE
739 x 570 x 8-bit (CCIR) @ 25fps
Interlaced
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sending TTL hsync (HD IN) and vsync (VD IN becomes RR trigger)
Video HD IN
VD IN
TTL external trigger
Matrox Pulsar
(with PLS-TTL-CABLE)
signals to camera
DCF used: 77CEMT.DCF
1. Continuous mode (internal sync)
IMG-7W2-TO-1BNC and Sony JB-77 junction box required
Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Sony XC-77CE March 13, 1996
Cabling Requirements Continued
2. Continuous mode (external sync)
IMG-7W2-TO-1BNC, PLS-TTL-CABLE and Sony JB-77 junction box required
Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
The connections between the DB-37 connector of the PLS-TTL-CABLE and the Sony JB-
77 junction box are as follows:
PLS-TTL-CABLE JB-77 Junction Box (DB-37 connector) (BNC connectors)
Pin name Pin no. BNC name
TTL_HSYNC 26 HD IN TTL_VSYNC 11 VD IN GROUND 6 & 7 HD IN (GND) GROUND 6 & 7 VD IN (GND)
3. Restart reset mode
IMG-7W2-TO-5BNC, PLS-TTL-CABLE and Sony JB-77 junction box required
Video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT
BNC connector of Sony JB-77 junction box
The connections between the DB-37 connector of the PLS-TTL-CABLE and the Sony JB-
77 junction box are as in continuous mode (external sync) (i.e., VD IN becomes restart reset)
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-
7W2-TO-5BNC cable
Special Considerations
NOTE: all connections in this application note assume the use of the Sony JB-77 junction
box. These connections can also be made directly with the 12-pin connector on the camera; consult the Sony XC-77CE documentation for a pinout description of this connector. Contact your local sales representative or Matrox Sales Office, or contact Matrox Imaging Applications at (514) 822-6061 for assistance.
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp.matrox.com). The information furnished by Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
CorporateCorporate Headquarters:Headquarters: Canada and U.S.A.Canada and U.S.A. Matrox ElectronicMatrox Electronic Systems Ltd.Systems Ltd.
1055 St.Regis Blvd. Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273
PUL-CID-001 2
Sales Offices:Sales Offices: U.K.U.K.
Matrox (UK) Ltd.Matrox (UK) Ltd.
Sefton Park, Stoke Poges Buckinghamshire U.K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599
FranceFrance Matrox France SARLMatrox France SARL
2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05
GermanyGermany Matrox GmbHMatrox GmbH
Inselkammerstr.8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743
Asia PacificAsia Pacific Matrox Asia LiaisonMatrox Asia Liaison OfficeOffice
Rm. 1901, 19/F, Workington Tower, 78 Bonham Strand E., Sheung Wan, Hong Kong. Tel: 852.2877.5387 Fax: 852.2537.9530
Loading...