Maxtor ES1.0 APPLICATION NOTE

MATROX PULSAR
1
CAMERA INTERFACE APPLICATION NOTE
REDLAKE MASD (KODAK) ES1.0 JUNE 19, 2001
Basics about the
Mode of operations as per Matrox Imaging (in
parentheses as per
camera manufacturer)
Basics about the
interface modes
Camera Descriptions
§ 1008 × 1018 × 8/10-bit @ 15/30 fps.
§ Single or dual channel RS-422 digital video output.
§ Progressive scan.
§ Internal or external sync.
§ Internal or external exposure control.
§ 20 MHz pixel clock rate.
Interface Modes
§ Pseudo-continuous
§ Asynchronous reset (Trigger, Control)
Camera Interface Briefs
Mode 1: Pseudo-continuous
§ 1008 × 1018 × 8-bit @ 15 fps.
§ Dual channel RS-422 digital video.
§ Progressive scan.
§ Matrox Pulsar receiving HSYNC (LINE ENABLE), VSYNC (FRAME
ENABLE), PIXEL CLOCK (PIX DATA @ 20 MHz) and video from camera.
§ DCF used: ES10D.DCF
VIDEO LINE EN. FRAME EN. PIX DATA
Mode 2: Asynchronous Reset (Trigger, Control)
§ 1008 × 1018 × 8-bit.
§ Dual channel RS-422 digital video.
§ Progressive scan.
§ Matrox Pulsar receiving TTL external trigger signal.
§ Matrox Pulsar sending EXPOSURE1 (EXPOSE) signal to camera to
initiate and control exposure time.
§ Matrox Pulsar receiving HSYNC (LINE ENABLE), VSYNC (FRAME ENABLE), PIXEL CLOCK (PIX DATA @ 20 MHz) and video signals from camera.
Continued…
*Matrox Pulsar RS-422 digital data input board
PUL-CID-038
MATROX PULSAR
2
CAMERA INTERFACE APPLICATION NOTE
REDLAKE MASD (KODAK) ES1.0 JUNE 19, 2001
Basics about the
interface modes
Camera Interface Briefs (Cont.)
Mode 2: Asynchronous Reset (Trigger, Control)
§ DCF used: ES10DA.DCF (Trigger)
§ DCF used: ES10DAE.DCF (Control)
VIDEO LINE EN. FRAME EN. PIX DATA EXPOSE
Specifics about
the interface modes
TTL EXTERNAL TRIGGER
*Matrox Pulsar RS-422 digital data input board
Camera Interface Details
Mode 1: Pseudo-continuous
§ Frame Rate: Matrox Pulsar receives the continuous video from the camera at 15 frames per second.
§ Exposure time: Exposure time is controlled by the Remote Panel software. Refer to the camera manual for more information.
§ Remote Panel software settings: Settings for this mode are as follows:
DEF GAB BKB BKE MDE EXE STP TRM TRS TRE RDM TPD TPW DGN
on -22 0 0 CS 15.096 P P AIA 1 2* 255 5 2
* Single channel = 1, dual channel = 2
Mode 2: Asynchronous Reset (Trigger)
§ Frame rate: The frame rate is determined by the frequency of the external trigger signal.
§ Exposure time: Exposure time is controlled by the Remote Panel software. Refer to the camera manual for more information.
§ Remote Panel software settings: Settings for this mode are as follows:
DEF GAB BKB BKE MDE EXE STP TRM TRS TRE RDM TPD TPW DGN
on -22 0 0 * 15.096 P P AIA 1 ** 255 5 2
* Trigger mode = TR, Control mode = CD **Single channel = 1, dual channel = 2
Mode 2: Asynchronous Reset (Control)
§ Frame rate: The frame rate is determined by the frequency of the external trigger signal.
§ Exposure time: The width (rising to falling edge) of the EXPOSURE1 (EXPOSE) signal initiates and controls the exposure. The exposure time can be modified in the DCF using Matrox Intellicam or with the MIL MdigControl() function. Default exposure for this DCF is 1 second. Consult the manual for more information.
§ Remote Panel software settings: Settings for this mode are as follows:
DEF GAB BKB BKE MDE EXE STP TRM TRS TRE RDM TPD TPW DGN
on -22 0 0 * 15.096 P P AIA 1 ** 255 5 2
* Trigger mode = TR, Control mode = CD **Single channel = 1, dual channel = 2
PUL-CID-038
MATROX PULSAR
3
CAMERA INTERFACE APPLICATION NOTE
REDLAKE MASD (KODAK) ES1.0 JUNE 19, 2001
Cabling details for this
interface mode
Pin name Pin no.
* Connection not necessary for this mode however allows this cable to be used for both modes.
Cabling Requirements
Mode 1: Pseudo-continuous
§ Cable: DBHD68-TO-OPEN (open ended) cable required for video, synchronization and control signals.
§ Connection: Connections between the 68-pin connector of the camera
and the 68-pin connectors of the Matrox Pulsar are as follows:
PULSAR/DIG/MOD (68-pin connector)
DATA7+ 10 MSB+ 02 DATA7- 44 MSB- 36 DATA6+ 11 MSB-1+ 03 DATA6- 45 MSB-1- 37 DATA5+ 13 MSB-2+ 04 DATA5- 47 MSB-2- 38 DATA4+ 14 MSB-3+ 05 DATA4- 48 MSB-3- 39 DATA3+ 15 MSB-4+ 06 DATA3- 49 MSB-4- 40 DATA2+ 16 MSB-5+ 07 DATA2- 50 MSB-5- 41 DATA1+ 19 MSB-6+ 08 DATA1- 53 MSB-6- 42 DATA0+ 20 MSB-7+ 09 DATA0- 54 MSB-7- 43 CLKIN+ 29 PIX DATA STRB+ 29 CLKIN- 63 PIX DATA STRB- 63 HSYNC+ 26 LINE ENA+ 26 HSYNC- 60 LINE ENA- 60 VSYNC+ 25 FRME ENA+ 25 VSYNC- 59 FRME ENA- 59 EXPOSURE1+ 30* EXPOSURE1- 64* EXPOSE- 64* TTL_USR0 31 C0 31 TTL_USR1 32 MC1 32 TTL_USR2 33 MC2 33 GROUND 01 -- GROUND 01 GROUND 12 -- GROUND 12 GROUND 34 -- GROUND 34 GROUND 35 -- GROUND 35 GROUND 46 -- GROUND 46 GROUND 68 -- GROUND 68
Continued…
REDLAKE MASD ES 1.0 (68-pin connector)
Pin name Pin no.
EXPOSE+ 30*
PUL-CID-038
MATROX PULSAR
CAMERA INTERFACE APPLICATION NOTE
REDLAKE MASD (KODAK) ES1.0 JUNE 19, 2001
Cabling details for this
interface mode
Cabling Requirements (Continued)
Mode 2: Asynchronous Reset (Trigger, Control, Double)
§ Cable: IMG-7W2-TO-5BNC and DBHD100-TO-OPEN (open ended) cables required for video, synchronization and control signals.
§ External Trigger: TTL external trigger source should be connected to the TTL trigger input of IMG-7W2-TO-5BNC cable.
§ Connection: All connections are as in Mode 1: Pseudo-continuous.
The DCF(s) mentioned in this application note can be found on the MIL or our FTP site (ftp.matrox.com). The information furnished by Matrox
Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
Corporate headquarters:
Canada and U.S.A. Matrox Electronic Systems Ltd.
1055 St. Regis Blvd. Dorval, Quebec H9P 2T4 Canada Tel: (514) 685-2630 Fax: (514) 822-6273
PUL-CID-038
Loading...