MaxStream 9XTend-NEMA Quick Start Manual

Quick Start Guide
9XTend-NEMA™ Weatherproof RS-232/485 RF Modem
Introduction
Range Test Setup
Range Test Procedure
Optional Configurations
www.maxstream.net © 2005 MaxStream, Inc. All rights reserved.
WARNING: When operating with 1 Watt power output, transmitting in close proximity of other RF modems can damage modem front-ends. Observe a minimum separation distance of 2' (0.6 m) between modems.
Refer to the 9XTend-PKG-R RS-232/485 product manual for information regarding operation of the 9XTend-NEMA RF Modem.
MD0025
Introduction
This guide provides step-by-step instruction on how to setup a wireless link and test the modem's ability to transport data over varying ranges and conditions.
Range Test Setup
Requirements for Range Test
1 XTend-NEMA Weatherproof RS-232/485 RF Modem 1 XTend-PKG-R RS-232/485 RF Modem (or a second XTend-NEMA) 1 PC (Windows 98 SE, 2000 or XP) loaded with X-CTU Software Accessories (CAT5 cable with DB-9/PWR adapter board, loopback adapter, 2 RPSMA
antennas (one is inside the NEMA enclosure), 2 power supplies)
Install X-CTU Software
Double-click "setup_X-CTU.exe" file and follow prompts of the installation screens. This file is located on the MaxStream CD and under the 'Software' section of the following web page: www.maxstream.net/helpdesk/download.php
The X-CTU software interface is divided into the following four tabs:
• PC Settings - Setup PC com ports to interface with the RF modem
• Range Test - Test RF modem's range under varying conditions
• Terminal - Read/Set RF modem parameters and monitor data communications
• Modem Configuration - Read/Set RF modem parameters
Hardware Setup
The XTend-NEMA RF Modem (remote) will be referred to as “NEMA”. The XTend-PKG-R RF Modem (base) will be referred to as “PKG-R”.
1. Verify DIP Switches of NEMA & PKG-R are set to their default positions (RS-232, Point-to-point Mode: Switches 1 and 5
1 2 3 4 5 6
O N
are ON (up) and the remaining 4 switches are OFF (down)).
[Refer to back page for important information regarding the DIP switch.]
2. Connect the female DB-9 connector of the PKG-R to the male DB-9 connector of the host PC using an RS-232 cable [Figure 1].
3. Attach the serial loopback adapter to the female DB-9 connector of NEMA. The serial loopback adapter configures the NEMA to function as a repeater by looping data back into the modem for retransmission. [Figure 1]
4. Attach RPSMA antenna to PKG-R. (NEMA antenna is inside the enclosure.)
5. Power NEMA through the DB-9/PWR adapter
NEMA
DB-9/PWR
RJ-45
DB-9
PWR
board and the PKG-R through its power connector using the included power supplies.
Figure 1. Hardware Setup
Adapter Board (top view)
Power Supply
Loopback Adapter
Host PC
RS-232 cable
PKG-R
RPSMA antennas
NEMA
CAT5 cable
Loopback
adapter