Maxspect R6-060, R6-120, R6-090 Owner's Manual

Bedienungsanleitung
Mode d’emploi
Manuali dei Prodotti
Manual do Proprietário
Instrukcja Obsługi
用户手册
使用說明書
1
Dear Customer,
Thank you for purchasing this product.
For optimum performance and safety, please read these instructions carefully.
User Memo:
Date of purchase:
Dealer name:
Dealer address:
Dealer website:
Dealer email:
Dealer phone no.:
Please visit us on facebook or twitter!
https://www.facebook.com/Maxspect
http://twitter.com/maxspectled
English
2
Package Content
Please check the content in the package.
R6-060
R6-090
R6-120
Power Supply Unit
Stands
Screws
English
3
Precautions
Before using the Maxspect Recurve LED Lighting System
1. Remove any plastic bags and packaging material protecting the fixture.
2. Never look directly at the LED bulbs when you switch on the system. Incorrect use of this
apparatus will increase eye hazard.
On Safety
1. Power Source – Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
2. Power Cord Protection – The power supply cords should be routed so that they are
not likely to be walked on or pinched by items placed upon or against them. Never take hold of the plug or cord if your hand is wet, and always grasp the plug body when connecting or disconnecting it.
3. Installation – Install indoor only, and use the attachments, mounting frames, hanging
kit and accessories provided and specified by the manufacturer.
On Operation
1. Operation – Always follow the operation instructions set forth in this manual when using
this Maxspect™ Recurve LED Lighting System.
2. Heat – The apparatus should be situated away from heat sources such as radiators, and
do not expose to excessive heat such as sunshine, fire or the like.
3. Moisture – To reduce the risk of fire or electric shock, do not expose this apparatus to
rain, moisture, dripping or splashing.
4. Ventilation – The apparatus should be situated so that its location or position does not
interfere with its proper ventilation.
5. Magnetism – The apparatus should be situated away from equipment or devices that
generate strong magnetism.
6. Cleaning – Clean only with dry cloth.
Before using this Maxspect™ Recurve LED Lighting System please read
these operating instructions carefully. Take special care to follow the safety
suggestions listed below.
Afterwards keep this manual handy for future reference.
English
4
Installation
Mounting the Recurve LED Lighting System
Before connecting the Recurve to the power supply, first mount the system by using the provided stand.
1. Tank-top mounting.
2. Pendant Mounting (hanging Kits sold separately).
English
5
Built-in Controller
The Recurve can be controlled directly with the built-in controller. The built-in controller integrated in the Recurve features an OLED monitor and a control dial, from which user can setup all the functions for the fixture.
Standard or Master/Slave Mode
Supporse there are 2 or more units of Recurve fixtures, user can connect them together through the Master/Slave mode to control them simultanousely - all Slave fixtures will follow the settings programmed on the Master fixture, saving time and effort on setting up multiple fixtures.
Control with iOS or Android Devices (Optional)
The Recurve can also be wirelessly connected to an ICV6 controller (sold separately), which allows the Recuve fixtures to be controlled by iOS or Android devices through the Syna-G System.
Operating Instructions
English
6
Basic Operations
Follow the instructions below to operate and program the Recurve LED fixture.
The Recurve turns on automatically when power is connected, and turns off when power is cut.
When power is resumed, the Recurve will restore to the previous saved setting automatically, whether it was last set at Manual or Automatic Mode, and the intensity level of all the LED channels.
The fan on the Recurve fixture is temperature controlled.
The Recurve has a built-in temperature control system. The fan will be automatically engaged when the temperature is above 45°C/113°F, and disengage when it is below 40°C/104°F.
If the fan fails, the system may overheat and the system will enter fail-safe mode when the temperature is above 70°C/158°F, turning off all channels. The system will exit fail-safe mode and resume normal operation when the temperature drops below 60°C/140°F.
Switching between Auto and Manual Mode
The Recurve has two modes of operations: Auto and Manual Mode. User can switch between the two modes with the control dial on the fixture.
3s
Press and hold the control dial for 3 seconds to switch to
another mode.
Operating Instructions
English
7
Manual Mode
Press the control dial to enter the setting. Press the control dial again to switch between the channels. Rotate the control dial to set the brightness for each LED
channel.
Press and hold the control dial for 3s to save the setting and
exit the page.
Automatic Mode
Press the control dial to enter the setting.
Rotate the control dial to switch between the settings. Press and hold the control dial for 3s to save the setting and
exit the page.
Within Automatic Mode, there are 3 settings for user to select:
System Clock: A clock set to be matched with users’ local time. Program: Program the photoperiod to set specific brightness for each LED channel during
different time of the day. Preset: 4 preset settings are available for user to choose from. (Refer to p.16) P1: SPS dominated tank. P2: SPS/LPS mixed tank. P3: Soft Coral/LPS mixed tank. P4: SPS dominated tank with a different dawn/dusk time with moon light.
Setting the clock
Press the control dial to enter the setting page and then
select “System Clock”.
Press the control dial to switch between hour and minute. Rotate the control dial to set the time. Press and hold the control dial for 3s to save the setting and
exit the page.
Operating Instructions
English
8
Understanding Time Points
There are a total of 24 Time Points. You can program different luminous output intensity at each Time Point to control the photoperiod and brightness of the system.
Take Preset P1 as an example, it is a setting for SPS dominated tank. The photoperiod starts at 08:00 where the system increases light gradually, peaks at 10:00 and lasts 10hrs to 20:00 before the system gradually decreases light until it is turned off at 22:00, with moon light turns on.
TP01
TP02
TP03
TP04
TP05
TP06
TP07
TP08
08:00
09:00
10:00
20:00
20:30
21:00
21:30
22:00
Channel A
0%
40%
90%
90%
70%
50%
25%
0%
Channel B
0%
20%
70%
70%
30%
15%
10%
0%
Channel C
0%
20%
90%
90%
30%
15%
10%
0%
Channel D
0%
20%
70%
70%
30%
15%
10%
0%
Channel E
0%
20%
90%
90%
30%
15%
10%
0%
Channel F
1%
40%
90%
90%
70%
50%
25%
1%
The following diagram illustrates how the 6 LED channels would behave once the above Time Points have been programmed.
Channel A
Channel C
Channel E
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Channel A Channel B Channel C Channel D Channel E Channel F
Operating Instructions
English
9
Operating Instructions
Programming Photoperiod
Modify
Press the control dial to switch between the parameters. Rotate the control dial to set the parameter. Press and hold the control dial for 3s to turn to the next
page.
Apply
Rotate the control dial to select “Apply”. Press the control dial to save the setting. Press and hold the control dial for 3s to return to the main
menu.
Preview
Rotate the control dial to select “Preview”. Press the control dial to runs the program in preview mode,
where the entire photoperiod is demonstrated in 3 minutes.
Press and hold the control dial for 3s to return to the main
menu.
Rotate the control dial to select “Modify”. Press the control dial to readjust the parameters, see
Modify above.
English
Time point #
Time
LED Channel
Intensity
10
Operating Instructions
Selecting Preset
Rotate the control dial to switch between the presets. Press the control dial to turn to the next page.
Apply
Rotate the control dial to select “Apply”. Press the control dial to save the setting.
Preview
Rotate the control dial to select “Preview”. Press the control dial to runs the program in preview mode,
where the entire preset is demonstrated in 3 minutes.
Press and hold the control dial for 3s to return to the main
menu.
Rotate the control dial to select “Exit”. Press the control dial to go back to the main menu.
English
11
Maintenance Instructions
System Setup
System Setup features a set of functions allowing user to do perform maintenance on the fixture.
To enter the System Setup page, first turn off the fixture, then press and hold the control dial while turning the fixture back on. Keep on holding the control dial until the system setup page is shown on OLED monitor.
There are 7 functions in the System Setup screen.
1. Firmware
2. Restore
3. Reset
4. Test Mode
5. Model Number
6. Standard or Master/Slave mode
7. Exit
1. Firmware
This function allows the user to update the firmware.
Rotate the control dial to select “Firmware”. Press the control dial to begin the firmware update.
When there is no SD card or invalid firmware in the SD card,
“NO SD Card” or “Wrong File” will be shown.
Otherwise the firmware update progress will be shown.
Once the firmware has been updated successfully, the
fixture will restart automatically and the new firmware version number will be shown.
English
12
Maintenance Instructions
2. Restore
This function allows the user to restore the firmware to its original factory version. After finish restoring the firmware, the fixture will restart automatically and the firmware version number will be shown.
Rotate the control dial to select “Restore”. Press the control dial to restore the firmware.
3. Reset
This function allows the user to reset the fixture back to its factory settings. After finish resetting the fixture, itll restart automatically.
Rotate the control dial to select “Reset”. Press the control dial to factory reset the fixture.
4. Test Mode
This function allows the user to put the fixture in the test mode, which would help our customer service representative to diagnose the fixture. This should only be done by the
users when told by authorized dealer or customer representative to perform certain test on the fixture.
5. Model Number
This function will display the model number of the fixture, which also double serves as the ID name when the Recurve is connected to an iOS or Android device through the Syna-G system.
Under normal circumstances this value should not be changed.
English
13
Maintenance Instructions
6. Standard or Master/Slave Mode
This function allows the user to choose between the Standard stand-alone operation mode, or Master/Slave mode where multiple units of Recurve fixtures can be connected together.
Once connected, all Slave fixtures will follow the settings programmed on the Master fixture, saving time and effort on setting up multiple fixtures.
The default value is Standard meaning the fixture is running in stand-alone operation mode.
When a Recurve is set as Master Unit, it will need to assign a channel from 01 to 10. All connecting Slave Units must be also assigned to the same channel.
In case where multiple groups of Master/Slave coexist in a proximity, each Master Unit must assign a different channel to avoid interference with another group.
Rotate the control dial to select “Standard”. Press the control dial to enter the setting page.
Rotate the control dial to assign it as a “Master” or “Slave”
unit.
After selecting Master/Slave unit, press the control dial to
assign a channel.
Press and hold the control dial for 3s to save the setting.
7. Exit
Press “Exit” to restart the fixture.
English
14
Important Information
Maintenance of the fixture
User must periodically perform maintenance on the fixture, including but not limited to the following steps:
Using a damp cloth to clean the acrylic lens to make sure it’s not covered by salt creep
or other dirt and debris. Uncleaned lens will severely affect the luminous output of the fixture, so for best performance you should clean the lens once a week.
Clean the dust and debris trapped in the fan units. Regularly and properly cleaned fans
will last much longer than those that aren’t. Fan units are wear-and-tear parts and must be replaced every 24-36 months depends on the frequency of maintenance performed on them.
Clean / remove any salt creep or dirt and debris that had been builtup or collected on
the aluminum body of the fixture, as they may affect the dissipation of heat from the fixture.
Note: Failure to perform the above mentioned maintenance on the fixture may cause unnecessary damage to your fixture and may void your warranty!
Tutorial Video
For additional information regarding installation or operation of our products, please visit our Official YouTube Channel using the following QR Code.
Specifications
For latest specifications on LED layout, types and color spectrum, please visit our website at: www.maxspect.com
English
15
Limited Warranty
Maxspect (HongKong) Limited warrants all MaxspectRecurve LED Lighting System products against defects in workmanship for a period of 12-months from the date of purchase. If a defect exists during the warranty period, Maxspect (HongKong) Limited at its option will either repair (using new or remanufactured parts) or replace (with a new or remanufactured unit) the product at no charge.
THE WARRANTY WILL NOT APPLY TO THE PRODUCT IF IT HAS BEEN DAMAGED BY MISUSE, ALTERATION, ACCIDENT, IMPROPER HANDLING OR OPERATION, OR IF UNAUTHORIZED REPAIRS ARE ATTEMPTED OR MADE. SOME EXAMPLES OF DAMAGES NOT COVERED BY WARRANTY INCLUDE, BUT ARE NOT LIMITED TO, USING AFTER-MARKET LED BULBS AND MODIFICATION OF THE CIRCUITRY, WHICH ARE PRESUMED TO BE DAMAGES RESULTING FROM MISUSE OR ABUSE.
DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES:
You and any other user of Maxspect (HongKong) Limited products shall not be entitled to any consequential or incidental damages, including without limitation, loss of use of the unit, inconvenience, damage to personal property, phone calls, lost income or earnings. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
MAXSPECT LTD. MAKES NO WARRANTY OR REPRESENTATION, EITHER EXPRESS OR
IMPLIED, WITH RESPECT TO THE PRODUCT'S QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. AS A RESULT, THIS PRODUCT, IS SOLD "AS IS," AND YOU THE PURCHASER ASSUME THE ENTIRE RISK AS TO ITS QUALITY AND PERFORMANCE.
IN NO EVENT WILL MAXSPECT LTD BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY DEFECT IN THE PRODUCT OR ITS DOCUMENTATION.
The warranty, disclaimer, and remedies set forth above are exclusive and replace all others, oral or written, expressed or implied. At no time will any Maxspect (HongKong) Limited dealers, agents, or employees be authorized to make any modifications, extension, or addition to this warranty.
Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you.
English
16
Preset
Preset 1 Preset 2
Preset 3 Preset 4
Channel A
0%
20%
40%
60%
80%
100%
8:00
10:00
12:00
14:00
16:00
18:00
20:00
21:00
22:00
Channel A Channel B Channel C
Channel D Channel E Channel F
Channel A
0%
20%
40%
60%
80%
100%
10:00
12:00
14:00
16:00
18:00
20:00
21:00
22:00
Channel A Channel B Channel C
Channel D Channel E Channel F
Channel A
0%
20%
40%
60%
80%
100%
10:00
12:00
14:00
16:00
18:00
20:00
21:00
22:00
Channel A Channel B Channel C
Channel D Channel E Channel F
Channel A
0%
20%
40%
60%
80%
100%
11:00
13:00
15:00
17:00
19:00
21:00
23:00
0:00
1:00
Channel A Channel B Channel C
Channel D Channel E Channel F
English
17
Sehr geehrter Kunde,
vielen Dank für den Kauf dieses Produkts.
Für eine optimale Leistung und Sicherheit, lesen Sie bitte diese Anleitung sorgfältig.
Nutzer-Memo:
Kaufdatum
Händler:
Händleradresse:
Händlerwebsite:
Händler-E-Mail:
Händlertelefon
Bitte besuchen Sie uns auf Facebook oder Twitter!
https://www.facebook.com/Maxspect
http://twitter.com/maxspectled
Deutsch
18
Packungsinhalt
Bitte überprüfen Sie den Lieferumfang auf Vollständigkeit.
R6-060
R6-090
R6-120
Netzteil
Aufsetzsystem
Handschrauben
Deutsch
19
Sicherheitshinweise
Vor der Benutzung des Maxspect Recurve LED-Beleuchtungssystems
3. Falls vorhanden, entfernen Sie vor der Benutzung alle Schutzfolien.
4. Schauen Sie nie direkt in die LED-Leuchten wenn Sie das System einschalten. Die
unsachgemäße Nutzung dieses Geräts kann eine Gefahr für die Augen bedeuten.
Zur Sicherheit
1. Stromquelle – Setzen Sie die sicherheitsrelevanten Merkmale eines gepolten oder eines
geerdeten Steckers nicht außer Kraft. Ein geerdeter Stecker verfügt über zwei Stifte und über einen dritten Erdungsstift. Der Erdungsstift ist zu Ihrer Sicherheit vorhanden. Sollte der Stecker nicht in Ihre Steckdose passen, kontaktieren Sie einen Elektriker, um die veraltete Dose austauschen zu lassen.
2. Netzkabel – Die Netzkabel sollten so verlegt werden, dass man nicht darüber steigen
muss und sie auch nicht von Gegenständen beschädigt werden können, die unter oder neben den Kabeln liegen. Fassen Sie den Stecker oder das Kabel nie mit nassen Händen an und greifen Sie den Stecker beim Einstecken oder Abziehen immer direkt an.
3. Installation – Nur im Innenbereich benutzen und verwenden Sie nur die vom Hersteller
mitgelieferten Zubehörteile, Befestigungsrahmen und Aufhängsysteme.
Zum Betrieb
1. Bedienung – Befolgen Sie immer die Bedienhinweise dieses Handbuchs, wenn Sie das
Recurve LED-Beleuchtungssystem nutzen.
2. Hitze – Das Gerät sollte fern von Wärmequellen, wie zum Beispiel Heizkörpern,
aufgestellt werden und darf keiner großen Hitze, wie etwa Sonneneinstrahlung oder Feuer, ausgesetzt werden.
3. Feuchtigkeit – Zur Verringerung der Stromschlaggefahr darf das Gerät nicht mit Regen,
Feuchtigkeit, Tropf- und Spritzwasser in Kontakt kommen.
4. Belüftung – Das Gerät sollte so aufgestellt werden, dass Standort und Position die
Belüftung des Geräts nicht beeinträchtigen.
5. Magnetismus – Das Gerät sollte fern von Anlagen oder Geräten aufgestellt werden, die
starken Magnetismus erzeugen.
6. Reinigung – Reinigen Sie das Gerät nur mit einem trockenen Tuch.
Vor der ersten Inbetriebnahme des Maxspect™ LED-Beleuchtungssystems Recurve sollten Sie diese Bedienungsanleitung sorgfältig lesen. Bitte
beachten Sie die folgenden Sicherheitshinweise mit großer Sorgfalt. Bewahren Sie diese Anleitung auch zum späteren Nachschlagen auf.
Deutsch
20
Installation
Montieren des Recurve LED-Beleuchtungssystems
Bevor Sie die LED-Module mit dem Steuergerät verbinden, montieren Sie zunächst das System mit Hilfe des Aufsetzsystems.
1. Aquariumaustellung
2. Deckenbefestigung (Seilset optional erhältlich)
Deutsch
21
Eingebauter Controller
Die Recurve kann mit dem integrierten Controller gesteuert werden. Sie hat einen OLED-Display und ein Einstellrad mit denen der Benutzer alle Funktionen der Recurve sofort einstellen kann.
Standard- oder Master / Slave-Modus
Ab 2 oder mehr Recurve Einheiten, kann der Benutzer die Leuchten über den Master / Slave-Modus miteinander verbinden und gleichzeitig programmieren. Alle Slave-Einheiten übernehmen dann die Einstellungen von der Master-Recurve und der Benutzer spart somit Zeit und Mühe bei Verwendung von mehreren Einheiten.
Steuerung mit iOS- oder Android-Geräten (optional)
The Recurve can also be wirelessly connected to an ICV6 controller (sold separately), which allows the Recuve fixtures to be controlled by iOS or Android devices through the Syna-G System.
Bedienungsanleitung
Deutsch
22
Benutzung
Befolgen Sie die nachstehenden Anweisungen um die Maxspect Recurve in Betrieb zu nehmen.
Sobald Die Recurve an das Stromnetz angeschlossen wird schaltet sie sich automatisch ein, und schaltet sich aus, wenn sie vom Stromnetz getrennt wird
Wenn die Stromversorgung wieder eingeschaltet wird, kehrt die Recurve auf die früheren automatisch gespeicherten Einstellungen wieder zurück.
Der Lüfter der Recurve-Leuchte ist temperaturgesteuert.
Die Recurve hat ein integriertes Temperaturregelsystem. Der Lüfter schaltet sich automatisch ein wenn die Temperatur über 45°C liegt und schaltet sich aus wenn die Temperatur unter 40°C fällt.
Würde der Lüfter ausfallen, könnte die Leuchte überhitzen. Doch dank seinem Schutzsystem, wird die Recurve automatisch ausgeschaltet, wenn die Temperatur über 70°C liegt. Sobald die Temperatur unter 60°C absinkt, schaltet sich die Leuchte wieder ein und setzt den normalen Betrieb weiter.
Umschalten zwischen Auto und Manuell-Modus.
Die Recurve verfügt über 2 Betriebsarten: Auto und Manuell-Modus. Der Benutzer kann zwischen den beiden Modi mit dem Einstellrad auswählen.
3s
Den Drehregler 3 Sekunden lang gedrückt halten um von
einem Modus zum anderen zu wechseln.
Bedienungsanleitung
Deutsch
23
Manueller Modus
Drücken Sie den Drehregler um zur Einstellung zu gelangen Drücken Sie erneut den Drehregler, um zwischen den
Kanälen zu wählen.
Drehen Sie den Drehregler um die Helligkeit für jeden
LED-Kanal einzustellen.
Den Drehregler 3 Sek. lang gedrückt halten um die
Einstellung speichern und zu verlassen.
Automatischer Modus
Drücken Sie den Drehregler um zur Einstellung zu gelangen
Mit dem Drehregler zwischen den Einstellungen wechseln. Den Drehregler 3 Sek. lang gedrückt halten um die
Einstellung speichern und zu verlassen.
Innerhalb des automatischen Modus gibt es 3 Einstellungen für den Benutzer:
System Clock: für die Einstellung auf die Ortszeit des Benutzers. Program: Zum Programmieren der Photoperiode und Einstellung der Helligkeit von
jedem LED-Kanal für die verschiedenen Stunden des Tages.
Preset: 4 Voreinstellungen stehen für den Benutzer zur Auswahl. (Siehe Seite 32)
P1: Für Aquarien mit überwiegend SPS-Korallen. P2: Für Aquarien mit SPS und LPS. P3: Für Aquarien mit Weich- und LP- Korallen P4: Für Aquarium mit SPS-Korallen und einer anderen Morgen- und
Abenddämmerungszeit und mit Mondlicht.
Einstellung der Uhrzeit
Das Einstellrad drücken um die Einstellungsseite aufzurufen
und dann "System Clock" auszuwählen.
Das Einstellrad drücken um zwischen Stunde und Minute zu
wechseln.
Drehen Sie das Einstellrad um die Zeit einzustellen. Den Drehregler 3 Sek. lang gedrückt halten um die
Einstellung speichern und zu verlassen.
Bedienungsanleitung
Bedienungsanleitung
Deutsch
24
Zeitpunkte verstehen
Es gibt insgesamt 24 Zeitpunkte. Sie können zu jedem Zeitpunkt eine unterschiedliche Lichtausgangsintensität programmieren, um die Photoperiode und die Helligkeit des Systems zu steuern.
Nehmen wir Preset P1 als Beispiel, es ist eine Einstellung für Aquarien mit überwiegend SPS-Korallen. Die Beleuchtungsperiode beginnt um 8:00 Uhr und die Lichtintensität nimmt stufenweise zu, mit einem Pick um 10.00 Uhr der bis 20.00 Uhr dauert. Danach nimmt die Lichtintensität stufenweise bis um 22:00 Uhr ab und das Mondlicht schaltet sich ein.
TP01
TP02
TP03
TP04
TP05
TP06
TP07
TP08
08:00
09:00
10:00
20:00
20:30
21:00
21:30
22:00
Kanal A
0%
40%
90%
90%
70%
50%
25%
0%
Kanal B
0%
20%
70%
70%
30%
15%
10%
0%
Kanal C
0%
20%
90%
90%
30%
15%
10%
0%
Kanal D
0%
20%
70%
70%
30%
15%
10%
0%
Kanal E
0%
20%
90%
90%
30%
15%
10%
0%
Kanal F
1%
40%
90%
90%
70%
50%
25%
1%
Das folgende Diagramm zeigt, wie sich die 6 LED-Kanäle verhalten, sobald die Zeitpunkte von oben programmiert sind.
Kanal A
Kanal C
Kanal E
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Kanal A Kanal B Kanal C Kanal D Kanal E Kanal F
Bedienungsanleitung
Deutsch
25
Bedienungsanleitung
Photoperiode Programmierung
Änderung
Das Einstellrad drücken um zwischen den Einstellungen zu
wechseln.
Drehen Sie das Einstellrad um die Einstellungen festzulegen. Das Einstellrad 3s lang gedrückt halten um zur nächsten
Seite zu gelangen.
Bestätigen
Drehen Sie das Einstellrad um "Apply" auszuwählen. Drücken Sie das Einstellrad, um die Einstellung zu speichern. Das Einstellrad 3s lang gedrückt halten um zum Hauptmenü
zurückzukehren.
Vorschau
Drehen Sie das Einstellrad um "Preview" auszuwählen. Drücken Sie das Einstellrad um das Programm im
Vorschaumodus auszuführen. Die gesamte Photoperiode wird in 3 Minuten dargestellt.
Das Einstellrad 3s lang gedrückt halten um zum Hauptmenü
zurückzukehren.
Drehen Sie das Einstellrad, um "Modify" auszuwählen. Erneut drücken um die Einstellungen abändern. Siehe
"Ändern" oben.
Zeitpunkt #
Uhrzeit
LED-Kanal
Intensität
Deutsch
26
Bedienungsanleitung
Voreinstellungen auswählen
Drehen Sie das Einstellrad um zwischen den
Voreinstellungen auszuwählen.
Drücken Sie das Einstellrad um zur nächsten Seite zu
wechseln.
Bestätigen
Drehen Sie das Einstellrad um "Apply" auszuwählen. Drücken Sie das Einstellrad, um die Einstellung zu speichern.
Vorschau
Drehen Sie das Einstellrad um "Preview" auszuwählen. Drücken Sie das Einstellrad um das Programm im
Vorschaumodus auszuführen. Das gesamte Presetprogramm wird in 3 Minuten dargestellt.
Das Einstellrad 3s lang gedrückt halten um zum Hauptmenü
zurückzukehren.
Drehen Sie das Einstellrad um "Exit" auszuwählen. Drücken Sie das Einstellrad um zum Hauptmenü
zurückzukehren.
Deutsch
27
Wartungshinweise
Systemeinrichtung
Das Systemeinrichtungsmenu verfügt über eine Reihe von Funktionen, die es dem Benutzer ermöglichen, die Wartung des Gerätes durchzuführen.
Um das Systemeinrichtungsmenu aufzurufen, schalten Sie zuerst die Leuchte aus und drücken Sie dann auf das Einstellrad, während Sie das Gerät wieder einschalten. Halten Sie das Einstellrad so lange gedrückt, bis das Systemeinrichtungsmenu auf dem OLED-Monitor angezeigt wird.
Es gibt 7 Funktionen im Systemeinrichtungsmenu.
1. Firmware
2. Wiederherstellen
3. Rücksetzen
4. Testmodus
5. Modellnummer
6. Standard- oder Master / Slave-Modus
7. Verlassen
1. Firmware
Mit dieser Funktion kann der Benutzer die Firmware aktualisieren.
Drehen Sie das Einstellrad um “Firmware” auszuwählen. Drücken Sie auf das Einstellrad, um die
Firmware-Aktualisierung zu beginnen.
Wenn keine SD-Karte erkannt wird oder eine ungültige
Firmware in der SD-Karte ist, wird “NO SD-Karte” oder “Wrong File” angezeigt.
Andernfalls wird das Firmware-Update-Fortschritt angezeigt.
Sobald die Firmware-Aktualisierung erfolgreich war, wird das
Gerät automatisch neu gestartet und die neue Firmware-Versionsnummer wird angezeigt.
Deutsch
Loading...
+ 103 hidden pages