MaxPower Corp GE VH User Manual

GE Digital Energy Power Quality
Technical data sheet
Digital Energy™ Uninterruptible Power Supply
VH700 - 1000 - 1500 – 2000 UL
A product by:
General Electric Company CH – 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44
www.gepowerquality.com
General data
backup
Topology
Nominal output rating
Overall efficiency at nominal load
Heat dissipation at inverter nominal load,
PF=0.9. and charged battery
Cooling air (77-86ºF)
Audible noise level at one meter
Operating temperature range
Storage temperature range
Relative humidity Max.
Protection degree
Safety
EMC
Surge capacity
Electrostatic discharge immunity
Transport
Colour
Outlet connectors
Inlet connectors
Cooling
VFI, on line double conversion
VA/W 700/630 1000/900 1500/1350 1920/1740
% >87
W 86 123 184 237
CFM 15 21 32 41
dB(A) < 45 dB(A), load and temperature dependent
32 to 104ºF (0 to +40ºC) 59-77 ºF recommended for batteries)
-4 to 122ºF (-20ºC to +50ºC)
20-95% (non-condensing)
Steel-plastic / IP20
UL 1778, 4th Edition
FCC Part-15, Class B
EN61000-4-5: 6kV line-line / 6kV line-earth
EN 61000-4-2, 4kV contact / 15kV air discharge
On pallet / Tower and rack mountable
RAL 9005 (black)
NEMA 5-20R ( additional L5-20R in 2000 VA )
IEC-C14 in 700-1000VA and C20 in 1500-2000VA
Forced air
Input converter (rectifier + power factor correction)
Nominal AC input voltage
Input frequency range
Power factor
THDi
Nominal input current (no charging, Uin = nominal)
Inrush current
DC output voltage
120V
45 - 66 Hz
> 0.99
< 6%
Adc 6.6 9.1 13.9 16
None
2 x 210V
Battery charger
Battery charging characteristic
AC input voltage range
DC output voltage
Output current limitation
Recharge time
Constant current charging until boost voltage, then float voltage charging
60 to 140V
Vdc 40.5 81
Adc 1.5
3 hours for 90% capacity, standard battery
Battery data
Battery type
Float voltage at 25°C
Number & rating of 12V batteries (standard version)
Standard backup time at nominal resistive load
End of discharging voltage (Vdc/cell)
Standard backup extensions (Table.1 for time)
Modifications reserved Page 2/5 TDS_VHE_XXX_0K7_2K0_XGB.doc Technical Data Sheets VH700-2000VA UL
Sealed lead acid, VRLA
Vdc 40.5 81
3*7Ah 3*9Ah 6*7Ah 6*9Ah
min 8 8 7.2 8
Vdc 1.66
NO YES YES YES
Output converter (inverter)
Static
switch
-
15%
to
+10% of selected output voltage
(optional)
Four change
-
over contacts signalling following alar
ms:
- Remote
Power Off
Input voltage range
Nominal output power at PF=0.9
Nominal output power with resistive load
Nominal AC output voltage
Output voltage waveform
Output voltage tolerance:
- static resistive load
- dynamic mean deviation over half cycle
(load step 0-100-0%)
- with measured non-linear load 2.5:1
- recovery time to +/-1%
Overload capability (battery operation)
Short circuit current capability (app. 200ms)
Output frequency
Output frequency tolerance
Frequency tracking range
Max. phase shift difference input-output
Harmonic distortion with linear load
Harmonic distortion with non-linear load
Power factor range
Crest factor handling capability of non-linear load
Output power derating altitude
Protection
Inverter bridge
Vdc 200-220
VA 700 1000 1500 1920
W 630 900 1350 1740
Vac 120
sine wave
< 1%
< 2%
< 2%
2ms
110% during 4 minutes, 150% during 2 seconds
2.1 times nominal current during app. 200 ms
50/60 Hz auto selectable ( Default 60 Hz during cold start )
± 0.05% nominal, unless synchronized with mains
± 10% default ( ± 2% selectable )
< 1º typical ( max. 7º during tracking frequency range )
< 1%
< 6%
0.7 to 1 (Lag & Lead)
Up to 3:1
Up to 1000m no derating
Above 1000m 12.5% per 1000m, max. 4000m
Automatic transfer to bypass (if available)
In case of:
- internal circuit failure
- over temperature
- overload / short circuit
Output protected against connection to the mains
PWM and IGBT technology
Bypass
Primary Element Bypass voltage limits
Frequency tracking range
Slew rate
Overload capability on bypass
± 10% default (± 2% selectable) of selected output frequency
2 Hz/sec
120% ≥ 3min. 150% ≥ 1 min
Interfacing
Potential free contacts
Input terminals for
Note: all indicated values are typical. Variations may be found from one unit to another.
- bypass active
- mains failure
- battery low
- general alarm (programmable)
- Battery extension pack DC connector
Modifications reserved Page 3/5 TDS_VHE_XXX_0K7_2K0_XGB.doc Technical Data Sheets VH700-2000VA UL
Controls, s i gnals and a l arms
Front panel details
Rear panel details
On / Off Push – buttons UPS ON/standby LED On Bypass LED On Battery LED Alarm LED (red) Runtime LED bar Load level LED bar
Front panel
Input thermal circuit breaker Input / Output sockets DC connector for batteries Remote External Power Off Contacts (REPO) USB interface card USB/RS232/Relay Card * SNMP Card*
*option
Rear panel
2000VA
1500VA
1000VA
700VA
Optional f e a t ures
SNMP interface card
An SNMP interface adapter can be placed in the SNMP slot in the rear panel of the UPS, which allows the data interface to be connected directly to an Ethernet or Web.
USB/RS232/Relay Card
The card is provided with an USB connector, a 9-pole sub-D connector and four potential free changeover contacts, representing: mains failure, general alarm, battery low and bypass active.
Battery modules – extended runtime
Additional battery modules (up to 3) may be connected in parallel to in order to achieve a longer runtime. Every battery module is equipped with its DC cabling and it makes connection between modules very easy and simple.
Increasing of total battery capacity will correspond to a longer recharging time.
Modifications reserved Page 4/5 TDS_VHE_XXX_0K7_2K0_XGB.doc Technical Data Sheets VH700-2000VA UL
Table.1
APPLIANCE OUTLETS
ON
BATTERY
CHARGER
OPTIONAL
EXTENSION
BATTERY
BOOSTER
BATTERY
CONVERTER
CONVERTER
AUTOMATIC
FILTER
INPUT:
MAINS
OUTPUT:
FRONT PANEL
Model
VH700
Di mensions a n d batter y r u n times
UPS
Backup
time
(min.)
Total
capacity
(Ah)
8 7 ---
Nr. of extra
battery
cabinets
Battery cabinet
Dimensions
( HxWxD )
---
8 9 ---
VH1000
26 23 1 48 37 2
3.4x17.2x18.5 inch 87x438x470 mm
66 51 3 7 7 ---
VH1500
VH2000
35 21 1 63 35 2 88 49 3 8 9 --­26 23 1 50 37 2
3.4x17.2x21.3 inch 87x438x540 mm
101 lbs
74 51 3
UP S bloc k di agram, p r o t e ctions an d c able se c t i o ns
MAINS POWER WITH DISTURBANCES
FROM
RFI
FILTER
BATTERY
Recommended external fusing of input wiring
UPS
Mains / Bypass input CABLE SECTIONS
Model
VH 700
15A Class “B“ MCB VH 1000 15A Class “B“ MCB VH 1500 VH 2000
20A Class “B“ MCB 2.5
20A Class “B“ MCB
BYPASS
INPUT
MICRO-PROCESSOR CONTROL
OUTPUT
UPS cabinet
Weight
60 lbs
27kg
Shipping
weight
68 lbs
31kg
Dimensions
( HxWxD )
3.4x17.2x18.5 inch 87x438x470 mm
35 lbs/16 kg 49 lbs/22kg
37 lbs/17kg 53 lbs/23kg
64 lbs/29kg 73 lbs/33kg
46kg
110 lbs
50kg
3.4x17.2x21.3 inch 87x438x540 mm
71 lbs/32kg 79 lbs/36kg
PERFECT UPS POWER
RFI
BYPASS
OFF
Cable sections input and output recommended
by NEC standards
Alternatively, local standards to be respected
mm2 AWG
1.8 16
1.8 16
2.5 14
Weight
USB
RJ11
(optional)
USB
RS232
Relay
14
Shipping
weight
Modifications reserved Page 5/5 TDS_VHE_XXX_0K7_2K0_XGB.doc Technical Data Sheets VH700-2000VA UL