SAFETY INSTRUCTIONS
Read carefully these instructions before connecting the unit.
The operating voltage is indicated on the nameplate of the housing.
To prevent fire, short circuit, shock hazard:
Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
Refer to qualified technician before it's further operation.
To avoid any risk of overheating:
Install the unit in a well aery location and keep a minimum distance of 10 cm around
the apparatus for sufficient ventilation.
Do not place any items such as newspapers, table-cloths, curtains ... on the unit that
might cover the ventilation holes.
The unit must not be exposed to any source of heat (sun, heater,...).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place.
Pull out power plug to make the different connections of cables.
To avoid electrical shock, do not open the housing.
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualified personnel.
10/10
Model : 18050
220V / 24V PSU
1 input, 2 outputs
SAFETY INSTRUCTIONS
Read carefully these instructions before connecting the unit.
The operating voltage is indicated on the nameplate of the housing.
To prevent fire, short circuit, shock hazard:
Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
Refer to qualified technician before it's further operation.
To avoid any risk of overheating:
Install the unit in a well aery location and keep a minimum distance of 10 cm around
the apparatus for sufficient ventilation.
Do not place any items such as newspapers, table-cloths, curtains ... on the unit that
might cover the ventilation holes.
The unit must not be exposed to any source of heat (sun, heater,...).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place.
Pull out power plug to make the different connections of cables.
To avoid electrical shock, do not open the housing.
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualified personnel.
10/10
Model : 18050
220V / 24V PSU
1 input, 2 outputs

Technical specifications
Application
Outputs :
Insertion loss :
Protection between outputs :
Secondary DC power :
Power :
Output current :
Security :
Dimensions :
Technical specifications
2 / female F-type connectors
4 - 5 dB
10 dB
24V DC stabilized
230 V~ ±10%, 50 Hz / 10 VA
typ. 85 mA
max. 100 mA
overload and short-circuit protected,
double isolated
115 x 74 x 56 mm.
Application
UHF
Amplifier
Model:
18000
25dB
UHF TV
LED
18050
UHF Amplifier
Ch. 21 - 69
35dB
24V / 35mA
TV 1
TV 2
+24 V
When connecting o ne output only, load the second output with 75 Ohms.
NOTE :
Outputs :
Insertion loss :
Protection between outputs :
Secondary DC power :
Power :
Output current :
Security :
Dimensions :
2 / female F-type connectors
4 - 5 dB
10 dB
24V DC stabilized
230 V~ ±10%, 50 Hz / 10 VA
typ. 85 mA
max. 100 mA
overload and short-circuit protected,
double isolated
115 x 74 x 56 mm.
UHF
Amplifier
Model:
18000
25dB
UHF TV
LED
18050
UHF Amplifier
Ch. 21 - 69
35dB
24V / 35mA
TV 1
TV 2
+24 V
NOTE :
When connecting o ne output only, load the second output with 75 Ohms.